首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
DE-310 is a macromolecular carrier conjugate containing an anti-tumor camptothecin derivative, DX-8951, which is conjugated to a water-soluble polymer via a peptide spacer. Assay methods have been developed for the determination of a polymer-bonded DX-8951 conjugate, DX-8951, and Glycyl-DX-8951 (G-DX-8951) in mouse plasma. Free DX-8951 and Glycyl-DX-8951 were extracted from plasma by protein precipitation and analyzed by HPLC (Method I). Conjugated DX-8951 was extracted by protein precipitation and digested by using a thermolysin. The productive compound was analyzed by HPLC (Method II). The lower limits of quantitation of DX-8951, Glycyl-DX-8951, and Conjugated DX-8951 were 0.60, and 0.77 ng/ml and 3.45 microg/ml (as DX-8951 equivalent). These two methods showed satisfactory sensitivity, precision, accuracy, recovery, and selectivity.  相似文献   

2.
Assays were developed for determination of DE-310, a carboxymethyldextran polyalcohol conjugate of the topoisomerase I inhibitor DX-8951 (exatecan) and two enzymatic products (i.e. glycyl-DX-8951 and unconjugated DX-8951) in human whole blood, erythrocytes and saliva. Sample pretreatment involved a single protein-precipitation step, followed by a thermolysin-mediated deconjugation for the parent molecule. Separation of the compounds was achieved on an Inertsil ODS-80A column (150 mm x 4.6 mm i.d.; 5 microm PS), using isocratic elution. The column effluent was monitored at excitation and emission wavelengths of 375 and 445 nm, respectively. Validation results indicated that the methods are accurate and precise at lower limits of quantitation of 0.5-6.9 ng/ml. The methods were used to study the blood distribution and salivary concentrations in patients receiving DE-310.  相似文献   

3.
A sensitive quantitation of the lactone form and the lactone plus hydroxy-acid forms of DX-8951, a camptothecin derivative, in human plasma has been investigated by high-performance liquid chromatography (HPLC). This assay method consisted of two analytical procedures. In Procedure I, the lactone form was collected by the stepwise separation on a C18 cartridge. In Procedure II, the lactone plus hydroxy-acid forms were collected using another batch of the plasma sample by co-elution of the two forms from a C18 cartridge with acidic solution. The hydroxy-acid form of DX-8951 was quantitated from the difference of the lactone plus hydroxy-acid forms and the lactone form. Thereafter, these pre-treated samples were assayed by HPLC under the same HPLC conditions with a spectrofluorometer and a reverse-phase ODS column. The mobile phase was acetonitrile/0.05 M potassium dihydrogen phosphate (pH 3) (18:82, v/v) at a flow-rate of 1.0 ml/min. For the assay of the lactone form and the lactone plus hydroxy-acid forms of DX-8951 in plasma, analytical method were validated over the range 0.2–50 ng/ml.  相似文献   

4.
Currently available radioimmunoassay methods for estradiol in serum lack sufficient sensitivity and precision to monitor estradiol levels in patients placed on third generation aromatase inhibitors. We recently validated a gas chromatography/tandem mass spectrometry assay (GC/MS/MS) for estradiol and determined estrogen levels in normal post-menopausal women and in women with breast cancer before and during administration of aromatase inhibitors. Validation of the GC/MS/MS assay in human plasma and human serum included determination of assay sensitivity (<0.63 pg/ml), precision (all CVs less than 17.8%), recovery (98-103%), and linearity of recovery (R=0.998). Levels of estradiol were lower when assayed by GC/MS/MS compared to RIA under all conditions (7.26+/-4.82 pg/ml versus 11.9+12.0 pg/ml in normal post-menopausal women; 5.88+/-3.43 pg/ml versus 13.8+/-7.5 pg/ml in breast cancer patients prior to treatment; and<0.63 pg/ml versus 5.8+/-4.1 pg/ml during aromatase inhibitor therapy). Fifty-five women treated either with atamestane/toremiphene or letrozole/placebo were monitored for estradiol levels at 4, 8 and 12 weeks of therapy. The mean levels of estradiol during aromatase inhibitor therapy was 5.8+/-4.1 pg/ml as measured by RIA and <0.63 pg/ml by GC/MS/MS. The degree of suppression with the aromatase inhibitors as detected by RIA was 58% versus >89% by GC/MS. These results suggest that most RIA methods detect cross-reacting estrogen metabolites and yield higher measured levels than GC/MS/MS. Several pharmacological and clinical considerations suggest that GC/MS/MS should become the preferred method for monitoring aromatase inhibitor therapy.  相似文献   

5.
A highly sensitive and selective method has been developed and validated to determine limaprost, a prostaglandin (PG) E(1) analogue, in human plasma by on-line two-dimensional reversed-phase liquid chromatography-tandem mass spectrometry (2D-LC/MS/MS) due to the lack of efficient methods to determine very low levels of limaprost in plasma. Limaprost and its deuterium derivatives, used as internal standard, were extracted by protein precipitation and following three-step solid phase extractions. After extraction procedure, samples were analyzed by on-line 2D-LC/MS/MS with electrospray ionization in negative mode. The 2D-LC system consists of Phenyl column at first dimension and ODS at second dimension with a trapping column placed between the separation columns. The linear dynamic range of this method was 0.1-10 pg/ml with 3 ml of plasma (r >0.9987). Acceptable precision and accuracy were obtained over the calibration curve ranges. The assay has been successfully used in analyses of human plasma samples to support clinical pharmacokinetics studies.  相似文献   

6.
An analytical method for the determination of the PGE derivative nocloprost in plasma was developed combining the features of both radioimmunoassay and GC/MS. The antibody usually employed in nocloprost radioimmunoassay was coupled to Sepharose 4B and used as a stationary phase for the extraction of the drug. After appropriate derivatisation, nocloprost was determined by GC/MS in the negative ion-chemical ionisation mode. As an internal standard deuterated nocloprost was synthesized and added to the plasma samples before extraction. The extraction recovery was 94% and the limit of detection was 5 pg/ml. Intra- and interassay precision at 100 pg/ml was calculated as 3.3 and 4.0%, respectively.  相似文献   

7.
An analytical method for the determination of the PGE derivative nocloprost in plasma was developed combining the features of both radioimmunoassay and GC/MS. The antibody usually employed in nocloprost radioimmunoassay was coupled to Sepharose 4B and used as a stationary phase for the extraction of the drug. After appropriate derivatisation, nocloprost was determined by GC/MS in the negative ion-chemical ionisation mode. As an internal standard deuterated nocloprost was synthesized and added to the plasma samples before extraction. The extraction recovery was 94% and the limiy of detection was 5 pg/ml. Intra- and interassay precision at 100 pg/ml was calculated as 3.3 and 4.0%, respectively.  相似文献   

8.
Oxytocin (OT) is a neuropeptide with an extremely low endogenous level (low pg/ml) in human plasma. It is very challenging to develop a highly sensitive assay to measure endogenous OT, including radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA). Electrospray ionization (ESI) liquid chromatography–tandem mass spectrometry (LC–MS/MS) can provide high-throughput and selective methods for quantification of peptides in biological samples. A novel and highly sensitive two-dimensional LC–MS/MS (2D-LC–MS/MS) assay combining solid-phase extraction (SPE) has been developed and validated for the determination of endogenous OT in both human and rat plasma. The lower limit of quantification (LLOQ) was 1.00 pg/ml for human and 50.0 pg/ml for rat. Human plasma diluted with water (1:6, v/v) was successfully optimized as a surrogate matrix for human to prepare standard curves without endogenous interference. The extraction efficiency and absolute recovery were above 65.8% using the HLB SPE procedure, and matrix effects were lower than 12%. The method was validated in the range of 1.00–250 pg/ml for human plasma and 50.0–10,000 pg/ml for rat plasma with precision less than 12.7% and accuracy less than 7%.  相似文献   

9.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

10.
Salmeterol is an inhaled bronchodilator drug used for treatment of asthma. Its concentrations in plasma are very low or undetectable by previously developed methods. The present paper describes a method for analysis of salmeterol in human plasma with 2.5 pg/mL lower limit of quantitation. Despite the basic character of the drug the method uses mixed mode anion-exchange solid phase extraction for sample preparation combined with a column switching approach to minimize matrix effects. Samples are separated and detected by LC/MS/MS. The method is easy to use, only requires 0.5 mL of plasma and was validated for use in bioanalytical applications. The method does not suffer from interference from co-administered fluticasone propionate.  相似文献   

11.
Sensitive assay for determining plasma tenofovir concentrations by LC/MS/MS   总被引:1,自引:0,他引:1  
An LC/MS/MS assay for the determination of tenofovir (TNF) was developed and validated for use with the EDTA anticoagulated human plasma matrix. Heparin-treated plasma and serum matrices were also validated. After addition of adefovir as an internal standard, trifluoroacetic acid was used to produce a protein-free extract. Chromatographic separation was achieved with a Polar-RP Synergi, 2.0 mm x 150 mm, reversed-phase analytical column. The mobile phase was 3% acetonitrile/1% acetic acid, aq. Detection of TNF and the internal standard was achieved by ESI MS/MS in the positive ion mode using 288/176 and 274/162 transitions, respectively. The method was linear from 10 to 750 ng/ml with a minimum quantifiable limit of 10 ng/ml when 250 microl aliquots were analyzed. The usefulness of this LC/MS/MS method to routinely monitor plasma concentrations of TNF was demonstrated along with its ability to assist in the performance of pharmacokinetic studies.  相似文献   

12.
A rapid and precise method for the identification and quantification of cysteinyl leukotrienes (leukotriene C(4), leukotriene D(4) and leukotriene E(4)), essential markers of bronchial asthma, in exhaled breath condensate was developed. The protocol consists of immunoaffinity separation and a detection step, liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). In particular, the selected reaction monitoring mode was used for its extremely high degree of selectivity and the stable-isotope-dilution assay for its high precision of quantification. The developed method was characterized with a high precision (≤ 7.7%, determined as RSD), an acceptable accuracy (90.4-93.7%, determined as recovery), a low limit of detection (≤ 2 pg/ml EBC) and a low limit of quantification (≤ 10 pg/ml EBC). It was compared to other simple, clinically appropriate combinations of pre-treatment methods (solid phase extraction and lyophilization) with LC/MS. Finally, the method (a combination of immunoaffinity separation with LC-MS) was successfully tested in a clinical study where a significant difference was found in the concentration levels of cysteinyl leukotrienes between patients with occupational bronchial asthma and healthy subjects.  相似文献   

13.
A sensitive, simple and highly selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and evaluated to determine simultaneously the concentrations of pseudoephedrine and cetirizine in human plasma. The chief benefit of the present method is the minimal sample preparation, as the procedure is only one-step protein precipitation. Two drugs were separated on a C(8) column and analyzed by LC/MS/MS using positive electrospray ionisation (ESI). The method had a chromatographic run time of 12.0 min and a linear calibration curve over the concentration range of 1.0-800 ng/ml for pseudoephedrine and 1.0-400 ng/ml for cetirizine, respectively. The lower limit of quantification of the two drugs was 1.0 ng/ml, respectively. The intra- and inter-batch precisions were less than 9.7%. The method described herein has been first used to reveal the pharmacokinetic characters in healthy Chinese volunteers treated with oral administration of different dosages of cetirizine dihydrochloride and controlled-released pseudoephedrine hydrochloride compound tablet, and approached the influence of a standard meal on the extent and rate of absorption of the combination tablet.  相似文献   

14.
The aim of the present study was to determine the extent to which plasma catecholamines are conjugated in different animals compared to man and how widespread is the presence of dihydroxyphenylalanine (DOPA) and 3-methoxy-4-hydroxyphenylalanine (3-OMD) in plasma among the different animal species. Free and conjugated norepinephrine, epinephrine, and dopamine were measured in plasma in humans and in several animal species (dog, rat, Gunn rat, cat, rabbit, guinea pig, African green monkey, young pig, calf, and one American black bear) using HPLC with electrochemical detection. The same technique was used to measure free and conjugated DOPA and 3-OMD in plasma of man, dog, rat, Gunn rat, calf, and American black bear. Human plasma contains the highest concentration of total (free and conjugated) catecholamines (46.1 pmole/ml), while low concentrations (below 15 pmole/ml) were observed in unstressed rats, calves, cats, and young pigs. In man, 95.3% of total plasma catecholamines were conjugated. The extent to which plasma catecholamines were conjugated varied greatly between animal species. The conjugated fraction expressed as percentages of the total catecholamines is lowest in the young pig (4.7%) and highest in the bear (100%). Conjugated dopamine was present in the plasma of all species, varying between 3% of the total catecholamine pool in young pig to 90% in dog. Conjugated norepinephrine was also present in plasma of all species except in unstressed rats with access to food. Conjugated epinephrine was detected only in cat and rat. Free DOPA and 3-OMD were present in plasma of all tested species with especially high levels of 3-OMD being present in dog. Conjugated DOPA and 3-OMD were not consistently found in any species. Our results indicate that man, dog, bear, and African green monkey are particularly good catecholamine conjugators and that young pig, guinea pig, rabbit, and calf are poor conjugators.  相似文献   

15.
Imidafenacin (KRP-197/ONO-8025, IM), 4-(2-methyl-1H-imidazol-1-yl)-2,2-diphenylbutanamide, is a new antimuscarinic agent currently under application for the indication of treatment of overactive bladder in Japan. We developed and validated the sensitive and selective bioanalytical methods for the extremely low levels of IM and its metabolite, M-2 (Method 1), M-4 (Method 2) and M-9 (Method 3) in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In each method, plasma sample was extracted by solid phase extraction, separated on a semi-micro high performance liquid chromatography column and detected by tandem mass spectrometer with an atmospheric pressure chemical ionization or ionspray interface. Selected reaction monitoring mode was used for quantification. Each method was found to have acceptable accuracy, precision, stability, selectivity and linearity over the concentration range of 10-500 pg/mL for IM and M-2, 10-1000 pg/mL for M-4 and 50-5000 pg/mL for M-9. Using these analytical methods, concentration profiles of IM and its metabolites in human plasma were successfully determined even in the low pg/mL levels after oral administration of IM at the therapeutic dosage of 0.1 mg.  相似文献   

16.
BAPTA free acid was identified as the main metabolic product of 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(actoxymethyl ester) (BAPTA-AM), a neuroprotective agent in cerebral ischemia, in rats. In this paper, liquid chromatography-ultraviolet (LC-UV) and mass spectrometry/mass spectrometry (LC-MS/MS) methods were employed for the determination of BAPTA free acid in rat urine and feces and rat plasma, respectively. By liquid-liquid extraction and LC-UV analysis, a limit of quantitation of 1000 ng/ml using 0.2 ml rat urine for extraction and 250 ng/ml using 1 ml rat fecal homogenate supernatant for extraction could be reached. The assay was linear in the range of 1000-50,000 ng/ml for rat urine and 250-10,000 ng/ml for rat fecal homogenate supernatant. Because the sensitivity of the LC-UV method was apparently insufficient for evaluating the pharmacokinetic profile of BAPTA in rat plasma, a LC-MS/MS method was subsequently developed for the analysis of BAPTA free acid. By protein precipitation and LC-MS/MS analysis, the limit of quantitation was 5 ng/ml using 0.1 ml rat plasma and the linear range was 5.0-500 ng/ml. Both methods were validated and can be used to support a thorough preclinical pharmacokinetic evaluation of BAPTA-AM liposome injection.  相似文献   

17.
A high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) procedure for the simultaneous determination of diazepam from avizafone, atropine and pralidoxime in human plasma is described. Sample pretreatment consisted of protein precipitation from 100microl of plasma using acetonitrile containing the internal standard (diazepam D5). Chromatographic separation was performed on a X-Terra MS C8 column (100mmx2.1mm, i.d. 3.5microm), with a quick stepwise gradient using a formate buffer (pH 3, 2mM) and acetonitrile at a flow rate of 0.2ml/min. The triple quadrupole mass spectrometer was operated in positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges of 1-500ng/ml for diazepam, 0.25-50ng/ml for atropine and 5-1000ng/ml for pralidoxime. The coefficients of variation were always <15% for both intra-day and inter-day precision for each analyte. Mean accuracies were also within +/-15%. This method has been successfully applied to a pharmacokinetic study of the three compounds after intramuscular injection of an avizafone-atropine-pralidoxime combination, in healthy subjects.  相似文献   

18.
Ticagrelor is the first direct acting reversibly binding oral platelet P2Y(12) receptor antagonist. The parent molecule and the main metabolite (AR-C124910XX) are both able to block adenosine diphosphate-induced receptor signaling with similar potency. Drug binding to plasma proteins reduces free drug available for pharmacologic activity. Therefore, assessing unbound drug is important for interpretation of pharmacokinetic/pharmacodynamic findings. This paper describes the development and validation of an equilibrium dialysis/LC-MS/MS method for measuring unbound ticagrelor and AR-C124910XX in human plasma. Plasma samples (200μl) were dialysed against phosphate buffered saline (37 °C, 24h) in 96-well dialysis plates to separate unbound analytes. Drug-protein binding alterations during dialysis were minimized by maintaining physiologic conditions (pH 7.4, 37 °C). Ticagrelor and AR-C124910XX were quantified in dialysates (unbound fraction), retentates and plasma (total concentration) using liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) methods. Calibration curves were established for the retentate and plasma (total concentration) in the ranges 5-5000 ng/ml (ticagrelor) and 2.5-2500 ng/ml (AR-C124910XX), and for the dialysate in the range 0.25-100 ng/ml (both analytes). Both ticagrelor and AR-C124910XX were highly protein bound (>99.8%), i.e. unbound fraction <0.2%. Yet, the methodology was successfully applied to determine unbound concentrations of ticagrelor and AR-C124910XX in clinical samples.  相似文献   

19.
Ultrafiltration of human plasma in combination with LC-MS/MS has been increasingly used in the quantitative analysis of the free fraction of drug candidates for PK/efficacy assessment. In addition to controlling the pre-incubation and centrifugation temperatures, some important factors that must be investigated and addressed include: (1) possible nonspecific binding, (2) possible impact of freeze/thaw cycles of plasma samples and extended storage of plasma samples at room temperature on the analyte recovery prior to ultrafiltration, and (3) identification of the appropriate assay dynamic range to avoid unnecessary dilutions. These factors were explored in the development and validation of a robust LC-MS/MS assay for the quantitative analysis of unbound vadimezan (ASA404) in human plasma. First, to mimic human physiological conditions, all plasma samples were incubated at ~37°C for a minimum of 30 min after thawing and prior to centrifugation to obtain the ultrafiltrate. Second, by passing the calibration standards and QC samples in plasma ultrafiltrate through the ultrafiltration membrane, the observed non-specific binding of the analyte due to the membrane was corrected. Third, the effects of multiple freeze/thaw cycles and/or storage at room temperature for various periods (4, 8, 16 and 24h) were evaluated to determine the impact on analyte concentrations in the ultrafiltrate from the plasma QC samples. Fourth, the appropriate dynamic range was established to accommodate the expected incurred sample free analyte concentrations. The validated assay has a dynamic range of 30.0-30,000 ng/ml for ASA404 in human plasma ultrafiltrate using a sample volume of 30 μl. Quality control pools containing the analyte were prepared at concentrations of 30.0-22,500 ng/ml to cover the assay calibration range. The intra-assay and inter-assay precision and accuracy were ≤ 15% (CV) and within ± 15% (bias) of the nominal values, respectively, for all measured QC concentrations, including the LLOQ. Freeze/thaw for up to three cycles of the plasma samples and/or the extended human plasma sample exposure to room temperature for up to 24h were confirmed to have no impact on the assay results for the free analyte. The validated method was successfully implemented to support clinical studies for the compound.  相似文献   

20.
A radioimmunoassay for estimating both unconjugated and conjugated ethinyl estradiol (EE) in serum is described, along with a report of levels of EE attained after its administration and the binding of EE in plasma, as determined by this radioimmunoassay. Mean values for concentration of free EE were 38-87 pg/ml, 1-4 hours after administration, and by 24 hours levels in most subjects were below the sensitivity level of this assay, which is less than 25 pg/ml. Conjugated EE concentration in serum was considerably higher, with mean values of 370-770 pg/ml 1-4 hours after ingestion, decreasing slowly to mean values of 285 pg/ml at 8 hours and 100 pg/ml at 24 hours postadministration. Total EE (conjugated plus unconjugated) had a mean half-life of 3.8 hours during the period 2-8 hours after administration and 10.7 hours for the period 8-24 hours postadministration. EE in plasma was shown, by equilibrium dialysis, gel filtration on Sephadex G200, and polyacrylamide gel electrophoresis, to bind only to albumin, and no specific binding of EE occurred. The apparent association constant for the binding of EE to human serum albumin was 1.7 times 10 5 liter per mol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号