首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
乳腺癌是危及女性健康的常见恶性肿瘤之一,病死率较高,且发病年龄呈年轻化趋势。目前临床对乳腺疾病的检查方法很多,既往检查主要包括钼靶、超声等,因价格便宜、操作方便,已成为常规的乳腺疾病检查方法,但两者的敏感性和特异性较低并有自身的局限性。CT软组织分辨率较高,但检查过程中的X线剂量较大,并且动态增强时间较长,故作为乳腺钼靶的补充检查手段。这些检查方法对乳腺疾病均有不同的诊断意义,在当前众多诊断乳腺疾病方法中,具有无辐射,较高软组织分辨力及可多方位多层面成像的乳腺磁共振(MRI)成像有其独到的优势,某些方面能弥补超声和钼靶检查的局限性,乳腺磁共振可提供病灶形态学和增强血流动力学表现,可用于常规检查方法不能确诊病灶的鉴别诊断。乳腺肿瘤MRI成像对临床诊断、鉴别诊断及手术方案的选择有着极其重要的作用。本文就乳腺MRI影像技术、MRI影像学表现及其临床应用予以综述,探讨MRI在乳腺肿瘤中的应用。  相似文献   

2.
Breast cancer is a globally widespread disease whose detection has already been significantly improved by the introduction of screening programs. Nevertheless, mammography suffers from low soft tissue contrast and the superposition of diagnostically relevant anatomical structures as well as from low values for sensitivity and specificity especially for dense breast tissue. In recent years, two techniques for X-ray breast imaging have been developed that bring advances for the early detection of breast cancer. Grating-based phase-contrast mammography is a new imaging technique that is able to provide three image modalities simultaneously (absorption-contrast, phase-contrast and dark-field signal). Thus, an enhanced detection and delineation of cancerous structures in the phase-contrast image and an improved visualization and characterization of microcalcifications in the dark-field image is possible. Furthermore, latest studies about this approach show that dose-compatible imaging with polychromatic X-ray sources is feasible. In order to additionally overcome the limitations of projection-based imaging, efforts were also made towards the development of breast computed tomography (BCT), which recently led to the first clinical installation of an absorption-based BCT system. Further research combining the benefits of both imaging technologies is currently in progress. This review article summarizes the latest advances in phase-contrast imaging for the female breast (projection-based and three-dimensional view) with special focus on possible clinical implementations in the future.  相似文献   

3.
We have developed a high-sensitivity near-infrared (NIR) optical imaging system for noninvasive cancer detection based on the molecular-labeled fluorescent contrast agents. Recent developments in molecular beacons offer a way to selectively tag various precancer and cancer signatures and provide high tumor-to-background contrast. Near-infrared imaging can deeply probe tissue up to a couple of centimeters; thus, it possesses the potential for noninvasive detection of breast or lymph node cancer. A phase cancellation (in- and antiphase) device is used to increase the sensitivity in detecting fluorescent photons and the accuracy of tumor localization. The optoelectronic system consists of the laser diode sources, fiber optics, interference filter (to select the fluorescent photons), and the high-sensitivity photon detector (photomultiplier tube). The source-detector pair scans the tissue surface in multiple directions, and the localization image can be obtained by angular back-projection reconstruction. Simulations and experimental data demonstrated the feasibility of detection and localization offluorescent object embedded inside the highly scattering media. Tumor-bearing mouse model with injection of fluorescent contrast agents is used to simulate the human breast tumor labeled with molecular beacons. The system can detect fluorescent contrast agents as small as one nanomole at the depth of three centimeters, with a three-millimeter localization error. This instrument has the potential for tumor diagnosis and imaging, and the accuracy of the localization suggests that this system could help guide the clinical fine-needle biopsy. Also, this portable device would be complementary to x-ray mammography and provide add-on information on early diagnosis and localization of breast tumor.  相似文献   

4.
Mammography remains the gold standard in breast cancer detection, although there remains a challenge for improvement in sensitivity of breast cancer detection and diagnosis. Although mammography is the most frequently utilized examination to screen for breast cancer, which has resulted in a reduction of breast cancer mortality, still some cancers are unable to be visualized on mammographic images. Mammography films are interpreted using an anatomic approach. A new approach to breast cancer diagnosis utilizes a breast specific gamma camera to measure radiotracer uptake of abnormal tissue in the breast in patients with an abnormal mammogram or palpble mass using technetium sestamibi. Images are taken using the same positioning techniques as mammography for comparison of both types of images. Multi-Institutional trials using a traditional gamma camera demonstrated potential for this approach. However, the inability of traditional gamma camera intrinsic resolution and non-optinuized breast imaging limited scintimammography. Therefore, a breast specific, high resolution gamma camera was developed to overcome these limitations.Results of clinical studies evaluating BSGI are promising and are increasingly being used. Additionally, means for minimally invasive imaging-guided acquisition of tissue are being developed so that biopsies will be avaibles for areas of interest based on radiotracer uptake.Breast specific gamma camera nuclear imaging of the breast is a developing and increasingly utilized approach to improving breast cancer detection and diagnosis.  相似文献   

5.
目的:探讨彩色多普勒超声联合钼靶在未扪及肿块乳腺癌中的临床诊断价值。方法:选取我院乳腺科收治的未扪及肿块乳腺癌患者92例,回顾性分析92例患者术前彩色多普勒超声和钼靶检查结果与手术病理相印证,对比不同的检查方法与病理诊断结果的符合率。结果:单纯彩色多普勒超声检查与单纯钼靶机检查诊断准确率无明显差异(P0.05),而彩色多普勒超声联合钼靶机检查诊断准确率明显高于单纯彩色多普勒超声检查诊断准确率和单纯钼靶机检查诊断准确率,差异有统计学意义(P0.05)。结论:彩色多普勒超声联合钼靶能够明显提高未扪及肿块乳腺癌诊断的准确率,对临床具有指导意义,值得临床推广。  相似文献   

6.
The paper is concerned with the results of comparative analysis of the clinical, x-ray and cytological methods of investigation of women with breast tumors in situ (43 cases of cancer and 19 cases of intracanalicular fibroadenoma, the latter being difficult for differential diagnosis). A number of important diagnostic symptoms were identified. Cancer affected more frequently women over 55. It was characterized by the presence of microcalcinates (60 +/- 13%) and inadequacy of tumor sizes on palpation and on radiograms (35 +/- 7%). The diagnostic accuracy of the methods used separately was 44 +/- 8% for the clinical method, 79 +/- 7% for the x-ray method, and 89 +/- 3% for the cytological method. Their combined use in a specialized mammography unit resulted in 98 +/- 2% of diagnostic accuracy.  相似文献   

7.
Phase-contrast mammography using laboratory X-ray sources is a promising approach to overcome the relatively low sensitivity and specificity of clinical, absorption-based screening. Current research is mostly centered on identifying potential diagnostic benefits arising from phase-contrast and dark-field mammography and benchmarking the latter with conventional state-of-the-art imaging methods. So far, little effort has been made to adjust this novel imaging technique to clinical needs. In this article, we address the key points for a successful implementation to a clinical routine in the near future and present the very first dose-compatible and rapid scan-time phase-contrast mammograms of both a freshly dissected, cancer-bearing mastectomy specimen and a mammographic accreditation phantom.  相似文献   

8.
9.
摘要目的:分析早期乳腺癌的全数字X 线摄影与MRI影像学表现,评价全数字X 线摄影联合MRI 检查在早期乳腺癌诊断中的 临床价值。方法:回顾性分析2009 年10 月至2012 年5月在我院经穿刺或手术病理证实为早期乳腺癌的42例患者的临床资料, 术前均行数字X线及动态增强MR 检查,比较两种方法单独使用和联合使用的诊断乳腺癌的准确率。结果:全数字化X 线摄片 诊断早期乳腺癌的准确率为69.0%(29/42),动态增强MR 检查为95.2%(40/42),两者比较差异有统计学意义(P<0.05);两者联合使 用诊断早期乳腺癌的准确率为97.6%(41/42)。结论:动态增强MR 检查对早期乳腺癌的诊断价值明显优于全数字X线摄影,但后 者对微小钙化显示较好,两者联合可提高诊断正确率,尤其对多腺体型和致密型乳腺的早期乳腺癌的检出具有重要的价值。  相似文献   

10.
Yu Shen  Dongfeng Wu  Marvin Zelen 《Biometrics》2001,57(4):1009-1017
Consider two diagnostic procedures having binary outcomes. If one of the tests results in a positive finding, a more definitive diagnostic procedure will be administered to establish the presence or absence of a disease. The use of both tests will improve the overall screening sensitivity when the two tests are independent, compared with employing two tests that are positively correlated. We estimate the correlation coefficient of the two tests and derive statistical methods for testing the independence of the two diagnostic procedures conditional on disease status. The statistical tests are used to investigate the independence of mammography and clinical breast exams aimed at establishing the benefit of early detection of breast cancer. The data used in the analysis are obtained from periodic screening examinations of three randomized clinical trials of breast cancer screening. Analysis of each of these trials confirms the independence of the clinical breast and mammography examinations. Based on these three large clinical trials, we conclude that a clinical breast exam considerably increases the overall sensitivity relative to screening with mammography alone and should be routinely included in early breast cancer detection programs.  相似文献   

11.
目的:分析早期乳腺癌的全数字X线摄影与MRI影像学表现,评价全数字X线摄影联合MRI检查在早期乳腺癌诊断中的临床价值。方法:回顾性分析2009年10月至2012年5月在我院经穿刺或手术病理证实为早期乳腺癌的42例患者的临床资料,术前均行数字X线及动态增强MR检查,比较两种方法单独使用和联合使用的诊断乳腺癌的准确率。结果:全数字化X线摄片诊断早期乳腺癌的准确率为69.0%(29/42),动态增强MR检查为95.2%(40/42),两者比较差异有统计学意义(P〈0.05);两者联合使用诊断早期乳腺癌的准确率为97.6%(41/42)。结论:动态增强MR检查对早期乳腺癌的诊断价值明显优于全数字X线摄影,但后者对微小钙化显示较好,两者联合可提高诊断正确率,尤其对多腺体型和致密型乳腺的早期乳腺癌的检出具有重要的价值。  相似文献   

12.
We evaluated the clinical significance of the combined use of mammography + ultrasound as a new breast screening strategy. The inclusion criteria were: (1) females aged >40yrs; (2) breast cancer diagnosis by the breast image screening personnel at FUSCC; (3) screening by both ultrasound and mammography; (4) mammographic/sonographic images analyzed independently by different radiologists; and (5) follow-up for at least 1 year. Fifty-four women were enrolled. The analysis included diagnostic sensitivity of mammography, ultrasound, and mammography + ultrasound. The sensitivities of mammography and mammography + ultrasound were compared overall as well as among different age groups/breast densities. The screening sensitivity of mammography, ultrasound, and mammography + ultrasound was 79.6, 57.4, and 92.6 %, respectively. The difference between mammography and mammography + ultrasound was significant (P < 0.05). The benefit of including ultrasound with mammography as a new breast image screening strategy was found statistically significant in patients with dense breast on mammogram while it was non-significant in younger (<50 years) women. We, therefore, concluded that mammography + ultrasound increased the diagnostic sensitivity of breast screening; hence it was more desirable for women with dense breast on mammography.  相似文献   

13.
L K Temple  E E Wang  R S McLeod 《CMAJ》1999,161(8):1001-1008
OBJECTIVE: To make recommendations to physicians who provide follow-up care for women who have been treated for early-stage breast cancer. OPTIONS: Combination of blood tests, bone scans, liver echography and chest radiography for detection of distant disease; physical examination with or without mammography for detection of contralateral breast cancer; and physical examination with or without mammography for detection of ipsilateral recurrent disease after breast-conserving therapy. OUTCOMES: Survival, disease recurrence and quality-of-life measures for distant disease, local recurrence of disease and disease in the contralateral breast. EVIDENCE: A MEDLINE search for relevant articles published between January 1966 and January 1998 with the MeSH terms "breast neoplasms" and "neoplasm recurrence" (local and distant) with limits to "human" was done. A subsequent MEDLINE search using the MeSH terms "breast neoplasms," "neoplasm recurrence," "local/diagnosis" and "mammography" was done to address issues of mammography. The literature search was reviewed by a medical librarian and 2 breast cancer specialists to ensure completeness. BENEFITS, HARMS AND COSTS: Breast cancer is the most common cancer in Canadian women and is the second leading cause of death after lung cancer. Even with early-stage breast cancer, recurrence after treatment for primary breast cancer is frequent. Traditionally, follow-up has been felt to facilitate early detection and improve survival. Randomized controlled trials (RCTs) have shown that routine screening (blood tests and diagnostic imaging) for distant disease does not alter survival or quality of life over routine physical examination. In an underpowered secondary analysis of RCT data, the detection of contralateral breast cancer did not affect survival. However, there have been no RCTs examining the role of mammography and physical examination and their effect on survival in the detection of contralateral breast cancer. The sensitivity and specificity of mammography after local excision and radiotherapy is unknown. There have been no RCTs examining the role of mammography or physical examination, or both, and their effect on survival in the detection of ipsilateral breast recurrence. VALUES: The strength of evidence was evaluated using the methods of the Canadian Task Force on Preventive Health Care. A high value was placed on interventions that changed survival. When evidence was available, high value was also placed on interventions that affected quality of life. RECOMMENDATIONS: There is good evidence not to include blood work and diagnostic imaging as part of screening for distant disease (grade E recommendation). There is no evidence to suggest that mammography decreases mortality by detecting ipsilateral disease in the conservatively treated breast; however, there is indirect evidence that it may be beneficial (grade C recommendation). There is no direct evidence to suggest that physical examination or mammography, or both, should be used to detect contralateral breast cancer; however, there is indirect evidence that it may be beneficial (grade C recommendation). VALIDATION: The findings of this analysis were reviewed through an iterative process by the members of the Canadian Task Force on Preventive Health Care.  相似文献   

14.
Fabian H  Lasch P  Boese M  Haensch W 《Biopolymers》2002,67(4-5):354-357
IR microspectroscopic imaging is a relatively new approach for the examination of tissue sections. In contrast to standard light microscopy based procedures, the IR approach requires neither sample staining nor fixation. The IR spectra of breast tumor tissue sections are obtained via a microscope equipped with a focal plane array detector. This enabled the simultaneous collection of individual mid-IR spectra from thousands of different sample positions with a spatial resolution near the diffraction limit. The analysis of the IR data reveals a high sensitivity of the IR approach toward changes in tissue biochemistry and variations in breast tissue architecture. Moreover, the data demonstrate the need for collecting spectra with high spatial resolution at the level of individual cells. This minimizes problems associated with tissue microheterogeneity and is an essential prerequisite for future studies aimed at developing IR microspectroscopic imaging as a complement to present diagnostic tools for breast cancer.  相似文献   

15.
目的:探讨剪切波弹性成像在乳腺实性病变良恶性鉴别中的诊断价值。方法:收集2012年3月-2013年6月于我院收治的乳腺实性病变患者54例,共65个病灶,先后给予乳腺二维超声检查与剪切波弹性成像检查,采用弹性模量值与钼靶BI-RADS分级方法诊断,比较两种方法诊断的准确性。结果:良性病灶组弹性最小、最大值以及平均值、标准差与恶性病灶组比较差异具有统计学意义(P0.05);ROC曲线分析显示,在乳腺实性病变良恶性的鉴别中,弹性最大值明显优于平弹性均值;剪切波弹性成像对乳腺实性病变良恶性鉴别的敏感度、特异度、准确度、阳性预测值、阴性预测值高于二维超声技术(P0.05)。结论:剪切波弹性成像在乳腺实性病变良恶性鉴别中具有良好的诊断价值,能够提高诊断的准确性。  相似文献   

16.
Invasive cancer causes a change in density in the affected tissue, which can be visualized by x-ray phase-contrast tomography. However, the diagnostic value of this method has so far not been investigated in detail. Therefore, the purpose of this study was, in a blinded manner, to investigate whether malignancy could be revealed by non-invasive x-ray phase-contrast tomography in lymph nodes from breast cancer patients. Seventeen formalin-fixed paraffin-embedded lymph nodes from 10 female patients (age range 37–83 years) diagnosed with invasive ductal carcinomas were analyzed by X-ray phase-contrast tomography. Ten lymph nodes had metastatic deposits and 7 were benign. The phase-contrast images were analyzed according to standards for conventional CT images looking for characteristics usually only visible by pathological examinations. Histopathology was used as reference. The result of this study was that the diagnostic sensitivity of the image analysis for detecting malignancy was 100% and the specificity was 87%. The positive predictive value was 91% for detecting malignancy and the negative predictive value was 100%. We conclude that x-ray phase-contrast imaging can accurately detect density variations to obtain information regarding lymph node involvement previously inaccessible with standard absorption x-ray imaging.  相似文献   

17.
目的:探讨自动乳腺全容积扫描(automated breast volume scanner,ABVS)联合乳腺钼靶摄影在乳腺疾病诊断中的价值。方法:观察随访130例就诊我科的乳腺疾病患者,进行ABVS、传统超声和乳腺钼靶检查。结果:130例患者中ABVS的疾病单独诊断准确率为91.5%(119/130),传统乳腺超声的单独诊断准确率为84.6%(110/130),乳腺钼靶的单独诊断准确率为86.9%(113/130),而ABVS联合乳腺钼靶应用的诊断准确率为95.4%(124/130),明显优于两者单独应用,差异具有统计学意义(P〈0.05)。结论:ABVS是一种全新的乳腺检查方法,较传统乳腺超声、乳腺钼靶具有较高的疾病诊断准确率,而ABVS联合乳腺钼靶可以显著提高诊断的准确率,值得在临床推广。  相似文献   

18.
摘要 目的:比较与分析钼靶和超声检查在乳腺癌临床诊断的准确性。方法:2018年8月到2021年1月选择在本院进行诊治的乳腺肿瘤患者110例作为研究对象,所有患者都给予钼靶和超声检查,记录影像学特征并判断诊断价值。结果:在110例患者中,病理诊断为乳腺良性肿瘤76例、乳腺癌34例。恶性组钼靶的分叶征、钙化、大角征、毛刺征等比例高于良性组,病灶大小也高于良性组(P<0.05)。恶性组超声的形态不规则、边缘不光整、高回声晕、回声衰减、微钙化等比例高于良性组(P<0.05)。钼靶乳腺影像报告及数据系统(Breast imaging report and data system,BI-RADS)判断为乳腺良性肿瘤72例,乳腺癌38例;超声BI-RADS判断为乳腺良性肿瘤75例,乳腺癌35例,钼靶鉴别诊断乳腺癌的敏感性为93.4%,特异性为97.1%,准确性为94.5%;超声鉴别诊断乳腺癌的敏感性为98.7%,特异性为100.0%,准确性为99.1%。多因素logistic回归分析显示病灶大小、分叶征、回声衰减、毛刺征为导致误诊的重要因素(P<0.05)。结论:乳腺癌在钼靶和超声检查中都有明显的征象特征,超声诊断的准确性更高,病灶大小、分叶征、回声衰减、毛刺征为影响诊断效果的很重要因素。  相似文献   

19.
Patients with sacroiliac joint, injuries, ankylosing spondyloarthritis, or spondyloarthropathy of various genesis were examined. Pelvis x-ray, spiral computed tomography (CT), and magnetic resonance imaging (MRI) were performed. MRI was found to have advantages in the detection and evaluation of the pattern of detectable bone changes. It is inexpedient to use traditional x-ray study and CT for the detection of edematous-infiltrative changes in both osseous and fibrous and soft tissue elements of the joint since the sensitivity of these techniques is insufficient to detect. To analyze detectable changes, it is expedient to use a unified MRI protocol that involves the characteristics of osseous, fibrous, and soft tissue structures of the joint.  相似文献   

20.

Background

Breast density is a significant breast cancer risk factor. Currently, there is no standard method for measuring this important factor. Work presented here represents an essential component of an ongoing project that seeks to determine the appropriate method for calibrating (standardizing) mammography image data to account for the x-ray image acquisition influences. Longer term goals of this project are to make accurate breast density measurements in support of risk studies.

Methods

Logarithmic response calibration curves and effective x-ray attenuation coefficients were measured from two full field digital mammography (FFDM) systems with breast tissue equivalent phantom imaging and compared. Normalization methods were studied to assess the possibility of reducing the amount of calibration data collection. The percent glandular calibration map functional form was investigated. Spatial variations in the calibration data were used to assess the uncertainty in the calibration application by applying error propagation analyses.

Results

Logarithmic response curves are well approximated as linear. Measured effective x-ray attenuation coefficients are characteristic quantities independent of the imaging system and are in agreement with those predicted numerically. Calibration data collection can be reduced by applying a simple normalization technique. The calibration map is well approximated as linear. Intrasystem calibration variation was on the order of four percent, which was approximately half of the intersystem variation.

Conclusion

FFDM systems provide a quantitative output, and the calibration quantities presented here may be used for data acquired on similar FFDM systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号