首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.

Objective

Larger animal models provide relevant tumor burden in the development of advanced clinical imaging methods for non-invasive cancer detection and diagnosis, and are especially valuable for studying metastatic disease. Most available experimental models, however, are based on immune-compromised mice. To lay the foundation for studying spontaneous metastasis using non-invasive magnetic resonance imaging (MRI), this study aims to establish a highly metastatic breast cancer xenograft model in nude rats.

Materials and Methods

A highly metastatic variant of human adenocarcinoma MDA-MB-231 known as LM2 was inoculated into nude rats. Orthotopic and subcutaneous (flank) sites were compared, with half of the orthotopic injections guided by ultrasound imaging. MRI with gadolinium contrast administration was performed weekly beginning on Day 6 and ending on Day 104. Excised tumors were assessed on histology using hematoxylin and eosin and CD34. Fisher''s exact test was used to compare successful tumor induction amongst different inoculation methods.

Results

Primary LM2 tumors were established orthotopically in all cases under ultrasound-guided injection, and none otherwise (p = 0.0028). Contrast-enhanced MRI revealed rapidly progressing tumors that reached critical size (15 mm diameter) in 2 to 3 weeks after inoculation. MRI and histology findings were consistent: LM2 tumors were characterized by low vascularity confined to the tumor rim and large necrotic cores with increasing interstitial fluid pressure.

Conclusions

The metastatic LM2 breast tumor model was successfully established in the mammary fat pads of nude rats, using ultrasound needle guidance as a non-invasive alternative to surgery. This platform lays the foundation for future development and application of MRI to study spontaneous metastasis and different stages throughout the metastatic cascade.  相似文献   

3.

Objective

To refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster analysis of low attenuation areas for comparison with histological measurement of surface area per unit lung volume.

Methods

The histological surface area per unit lung volume was estimated for 140 samples taken from resected lung specimens of fourteen subjects. The region of the lung sampled for histology was located on the pre-operative CT scan; the regional CT median lung density and emphysematous lesion size were calculated using the X-ray attenuation values and a low attenuation cluster analysis. Linear mixed models were used to examine the relationships between histological surface area per unit lung volume and CT measures.

Results

The median CT lung density, low attenuation cluster analysis, and the combination of both were important predictors of surface area per unit lung volume measured by histology (p < 0.0001). Akaike''s information criterion showed the model incorporating both parameters provided the most accurate prediction of emphysema.

Conclusion

Combining CT measures of lung density and emphysematous lesion size provides a more accurate estimate of lung surface area per unit lung volume than either measure alone.  相似文献   

4.

Background

Treatment of breast fibroadenoma remains a subject of clinical discussion. Recommended methods include clinical observation or surgical excision of the lesion. The procedure involves hospitalisation and anaesthesia, leaving a scar on the breast.

Aim

The aim of this study was to present the Centre''s experience in removing lesions radiologically suspicious of fibroadenoma by means of an ultrasound-guided vacuum-assisted core-needle biopsy as an alternative to a classical surgery.

Materials and methods

Between March 2007 and April 2010, 196 ultrasound-guided vacuum-assisted biopsies were performed in the Mammotome Biopsy Laboratory of the 1st Surgical Oncology and General Surgery Department at the Greater Poland Cancer Centre in Poznań. The procedure was delivered to female patients aged 17–91 years (mean 40.8, median 39). Qualified for removal were ultrasound identified lesions described as fibroadenomas.

Results

The average size of excised lesions according to pre-biopsy ultrasound image was 13.53 ± 8.92 mm (median 11 mm, range 4–60 mm). In 184 cases (93.9%), benign lesions were found in the final histopathologic examination. Pre-cancer lesions were found in 10 cases, and invasive lesions in two cases. Overall, after follow-up ultrasound examination, four patients were qualified for subsequent surgical resection of lesions that had been left behind.

Conclusion

Vacuum core-needle biopsy is an effective tool enabling removal of breast fibroadenomas. It combines features of a lesion resection and histopathologic material collection providing an access with minimum invasiveness.  相似文献   

5.

Background

Posttreatment surveillance for the local and regional recurrence of the head and neck squamous cell carcinoma often requires a multimodality techniques that include PET combined with CT, MRI, US.

Aim

The purpose of this study is to compare the diagnostic performance of two imaging techniques (PET/CT and US), and their combined use for the detection of a subclinical regional recurrence in patients after HNSCC treatment.

Materials and methods

83 patients after completion of the HNSCC treatment underwent both US and PET/CT on the mean follow-up of 14 months after initial treatment.

Results

The sensitivity and specificity of PET/CT were 86% and 82%, respectively; US values reached 81% and 87%, respectively. PPV was 79% for PET/CT, and 83% for US. NPV was 89% for PET/CT, and 85% for US. The overall accuracy for PET/CT and US was 84% for both methods.

Conclusion

US could be regarded as complementary to PET/CT as the procedures with highest sensitivity, specificity and NPV for detecting subclinical regional recurrences after HNSCC treatment.  相似文献   

6.

Background

Tumor size is one of the most important factors in making clinical and pathological assessment of breast cancer. In the present study, we aimed to determine whether the preoperative measurement of tumor size, by imaging modalities, deviate from the postoperative pathological measurement in breast cancer.

Patients and Methods

1296 patients diagnosed with invasive ductal breast carcinoma (IDC) during 2007 and 2009 were involved. Pre- and postoperative measurements of tumor size were compared using paired t-test and Chi-square test.

Results

The mean maximum diameters of tumors by imaging modalities and pathology were 27.9 mm and 22.4 mm, respectively. There was a statistically significant difference of 5.5 mm (95% CI: 4.7–6.2, p<0.001) between them. The discordance between pre- and post-surgical measurements of tumor size had significant effect on choosing surgery type, causing less application of breast conserving therapy (p<0.0001).

Conclusion

Compared to pathological size, preoperative measurement by imaging modalities tends to overestimate tumor size. These differences could have implications in the treatment of patients with breast cancer.  相似文献   

7.

Purpose

To evaluate the use of 3D optical surface imaging as a surrogate for respiratory gated deep-inspiration breath-hold (DIBH) for left breast irradiation.

Material and Methods

Patients with left-sided breast cancer treated with lumpectomy or mastectomy were selected as candidates for DIBH treatment for their external beam radiation therapy. Treatment plans were created on both free breathing (FB) and DIBH computed tomography (CT) simulation scans to determine dosimetric benefits from DIBH. The Real-time Position Management (RPM) system was used to acquire patient''s breathing trace during DIBH CT acquisition and treatment delivery. The reference 3D surface models from FB and DIBH CT scans were generated and transferred to the “AlignRT” system for patient positioning and real-time treatment monitoring. MV Cine images were acquired during treatment for each beam as quality assurance for intra-fractional position verification. The chest wall excursions measured on these images were used to define the actual target position during treatment, and to investigate the accuracy and reproducibility of RPM and AlignRT.

Results

Reduction in heart dose can be achieved using DIBH for left breast/chest wall radiation. RPM was shown to have inferior correlation with the actual target position, as determined by the MV Cine imaging. Therefore, RPM alone may not be an adequate surrogate in defining the breath-hold level. Alternatively, the AlignRT surface imaging demonstrated a superior correlation with the actual target positioning during DIBH. Both the vertical and magnitude real-time deltas (RTDs) reported by AlignRT can be used as the gating parameter, with a recommended threshold of ±3 mm and 5 mm, respectively.

Conclusion

The RPM system alone may not be sufficient for the required level of accuracy in left-sided breast/CW DIBH treatments. The 3D surface imaging can be used to ensure patient setup and monitor inter- and intra- fractional motions. Furthermore, the target position accuracy during DIBH treatment can be improved by AlignRT as a superior surrogate, in addition to the RPM system.  相似文献   

8.

Objectives

The aim of this work was to develop a MRI method to determine arterial flow reserve in patients with intermittent claudication and to investigate whether this method can discriminate between patients and healthy control subjects.

Methods

Ten consecutive patients with intermittent claudication and 10 healthy control subjects were included. All subjects underwent vector cardiography triggered quantitative 2D cine MR phase-contrast imaging to obtain flow waveforms of the popliteal artery at rest and during reactive hyperemia. Resting flow, maximum hyperemic flow and absolute flow reserve were determined and compared between the two groups by two independent MRI readers. Also, interreader reproducibility of flow measures was reported.

Results

Resting flow was lower in patients compared to controls (4.9±1.6 and 11.1±3.2 mL/s in patients and controls, respectively (p<0.01)). Maximum hyperemic flow was 7.3±2.9 and 16.4±3.2 mL/s (p<0.01) and the absolute flow reserve was 2.4±1.6 and 5.3±1.3 mL/s (p<0.01), respectively in patients and controls. The interreader coefficient of variation was below 10% for all measures in both patients and controls.

Conclusions

Quantitative 2D MR cine phase-contrast imaging is a promising method to determine flow reserve measures in patients with peripheral arterial disease and can be helpful to discriminate patients with intermittent claudication from healthy controls.  相似文献   

9.

Objective

To investigate the added diagnostic value of 3.0 Tesla breast MRI over conventional breast imaging in the diagnosis of in situ and invasive breast cancer and to explore the role of routine versus expert reading.

Materials and Methods

We evaluated MRI scans of patients with nonpalpable BI-RADS 3–5 lesions who underwent dynamic contrast-enhanced 3.0 Tesla breast MRI. Initially, MRI scans were read by radiologists in a routine clinical setting. All histologically confirmed index lesions were re-evaluated by two dedicated breast radiologists. Sensitivity and specificity for the three MRI readings were determined, and the diagnostic value of breast MRI in addition to conventional imaging was assessed. Interobserver reliability between the three readings was evaluated.

Results

MRI examinations of 207 patients were analyzed. Seventy-eight of 207 (37.7%) patients had a malignant lesion, of which 33 (42.3%) patients had pure DCIS and 45 (57.7%) invasive breast cancer. Sensitivity of breast MRI was 66.7% during routine, and 89.3% and 94.7% during expert reading. Specificity was 77.5% in the routine setting, and 61.0% and 33.3% during expert reading. In the routine setting, MRI provided additional diagnostic information over clinical information and conventional imaging, as the Area Under the ROC Curve increased from 0.76 to 0.81. Expert MRI reading was associated with a stronger improvement of the AUC to 0.87. Interobserver reliability between the three MRI readings was fair and moderate.

Conclusions

3.0 T breast MRI of nonpalpable breast lesions is of added diagnostic value for the diagnosis of in situ and invasive breast cancer.  相似文献   

10.

Background

The therapeutic efficacy of stereotactic radiosurgery for glioblastoma is not well understood, and there needs to be an effective biomarker to identify patients who might benefit from this treatment. This study investigated the efficacy of computed tomography (CT) perfusion imaging as an early imaging biomarker of response to stereotactic radiosurgery in a malignant rat glioma model.

Methods

Rats with orthotopic C6 glioma tumors received either mock irradiation (controls, N = 8) or stereotactic radiosurgery (N = 25, 12 Gy in one fraction) delivered by Helical Tomotherapy. Twelve irradiated animals were sacrificed four days after stereotactic radiosurgery to assess acute CT perfusion and histological changes, and 13 irradiated animals were used to study survival. Irradiated animals with survival >15 days were designated as responders while those with survival ≤15 days were non-responders. Longitudinal CT perfusion imaging was performed at baseline and regularly for eight weeks post-baseline.

Results

Early signs of radiation-induced injury were observed on histology. There was an overall survival benefit following stereotactic radiosurgery when compared to the controls (log-rank P<0.04). Responders to stereotactic radiosurgery showed lower relative blood volume (rBV), and permeability-surface area (PS) product on day 7 post-stereotactic radiosurgery when compared to controls and non-responders (P<0.05). rBV and PS on day 7 showed correlations with overall survival (P<0.05), and were predictive of survival with 92% accuracy.

Conclusions

Response to stereotactic radiosurgery was heterogeneous, and early selection of responders and non-responders was possible using CT perfusion imaging. Validation of CT perfusion indices for response assessment is necessary before clinical implementation.  相似文献   

11.

Background

TIA and minor stroke have a high risk of recurrent stroke. Abnormalities on CT/CTA and MRI predict recurrent events in TIA and minor stroke. However there are many other imaging abnormalities that could potentially predict outcome that have not been assessed in this population. Also the definition of recurrent events used includes deterioration due to stroke progression or recurrent stroke and whether imaging is either of these is not known.

Aims

To improve upon the clinical, CT/CTA and MRI parameters that predict recurrent events after TIA and minor stroke by assessing further imaging parameters. Secondary aim was to explore predictors of stroke progression versus recurrent stroke.

Methods

510 consecutive TIA and minor stroke patients had CT/CTA and most had MRI. Primary outcome was recurrent events (stroke progression or recurrent stroke) within 90 days. Further imaging parameters were assessed for prediction of recurrent events (combined outcome of stroke progression and recurrent stroke). We also explored predictors of symptom progression versus recurrence individually.

Results

36 recurrent events (36/510, 7.1% (95% CI: 5.0–9.6)) including 19 progression and 17 recurrent strokes. On CT/CTA: white matter disease, prior stroke, aortic arch focal plaque≥4 mm, or intraluminal thrombus did not predict recurrent events (progression or recurrent stroke). On MRI: white matter disease, prior stroke, and microbleeds did not predict recurrent events. Parameters predicting the individual outcome of symptom progression included: ongoing symptoms at initial assessment, symptom fluctuation, intracranial occlusion, intracranial occlusion or stenosis, and the CT/CTA metric. No parameter was strongly predictive of a distinct recurrent stroke.

Conclusions

There was no imaging parameter that could improve upon our original CT/CTA or MRI metrics to predict the combined outcome of stroke progression or a recurrent stroke after TIA and minor stroke. We are better at using imaging to predict stroke progression rather than recurrent stroke.  相似文献   

12.

Background

Intratumoral hemorrhage is a frequent occurrence in renal cell carcinoma and is an indicator of tumor subtype. We hypothesize that susceptibility weighted imaging (SWI) is sensitive to hemorrhage in renal cell carcinoma and can give a more diagnostic image when compared to conventional imaging techniques.

Materials and Methods

A retrospective review of 32 patients with clear cell renal cell carcinoma was evaluated. All patients underwent magnetic resonance imaging (MRI) and 22 out of 32 patients also underwent a computed tomography (CT) scan. Hemorrhage was classified into 3 different categories according to shape and distribution. Histopathology was obtained from all masses by radical nephrectomy. The ability to detect the presence of hemorrhage using CT, non-contrast conventional MRI and SWI was evaluated, and the patterns of hemorrhage were compared.

Results

Using pathologic results as the gold standard, the sensitivities of non-contrast conventional MRI, SWI and CT in detecting hemorrhage in clear cell renal cell carcinoma were 65.6%, 100% and 22.7%, respectively. Accuracy of non-contrast conventional MRI and SWI in evaluating hemorrhagic patterns were 31.3% and 100%, respectively.

Conclusion

These results demonstrate that SWI can better reveal hemorrhage and characterize the pattern more accurately than either non-contrast conventional MRI or CT. This suggests that SWI is the technique of choice for detecting hemorrhagic lesions in patients with renal cancer.  相似文献   

13.

Objective

Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content.

Design

a prospective study.

Setting

In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank.

Patients

23 patients with brain edema.

Interventions

The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes.

Measurement and Main Results

Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027). Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients'' responses to such treatment.

Conclusions

EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients.  相似文献   

14.

Background

Artifacts caused by dental restorations, such as dental crowns, dental fillings and orthodontic appliances, are a common problem in MRI and CT scans of the head and neck. The aim of this in-vitro study was to identify and evaluate the artifacts produced by different dental restoration materials in CT and MRI images.

Methods

Test samples of 44 materials (Metal and Non-Metal) commonly used in dental restorations were fabricated and embedded with reference specimens in gelatin moulds. MRI imaging of 1.5T and CT scan were performed on the samples and evaluated in two dimensions. Artifact size and distortions were measured using a digital image analysis software.

Results

In MRI, 13 out of 44 materials produced artifacts, while in CT 41 out of 44 materials showed artifacts. Artifacts produced in both MRI and CT images were categorized according to the size of the artifact.

Significance

Metal based restoration materials had strong influence on CT and less artifacts in MRI images. Rare earth elements such as Ytterbium trifluoride found in composites caused artifacts in both MRI and CT. Recognizing these findings would help dental materials manufacturers and developers to produce materials which can cause less artifacts in MRI and CT images.  相似文献   

15.

Background

Polymer gel dosimetry has been used extensively in radiation therapy for its capability in depicting a three dimensional view of absorbed dose distribution. However, more studies are required to find less toxic and more efficient polymers for application in radiotherapy dosimetry.

Aim

The purpose of this work was to evaluate the N-isopropyl acrylamide (NIPAM) gel dosimetric characteristics and optimize the protocol for X-ray computed tomography (CT) imaging of gel dosimeters for radiation therapy application.

Material and methods

A polymer gel dosimeter based on NIPAM monomer was prepared and irradiated with 60Co photons. The CT number changes following irradiation were extracted from CT images obtained with different sets of imaging parameters.

Results

The results showed the dose sensitivity of ΔNCT (H) = 0.282 ± 0.018 (H Gy−1) for NIPAM gel dosimeter. The optimized set of imaging exposure parameters was 120 kVp and 200 mA with the 10 mm slice thickness. Results of the depth dose measurement with gel dosimeter showed a great discrepancy with the actual depth dose data.

Conclusion

According to the current study, NIPAM-based gel dosimetry with X-ray CT imaging needs more technical development and formulation refinement to be used for radiation therapy application.  相似文献   

16.

Purpose

To evaluate whether gadoxetic acid (Gd-EOB-DTPA)-enhanced MR images of tumors taken during the hepatocyte-specific phase can aid in the differentiation between hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) in patients with atypical cirrhotic nodules detected on dynamic CT images.

Materials and Methods

Seventy-one patients with 112 nodules showing atypical dynamic enhancement on CT images underwent gadoxetic acid-enhanced MR imaging (MRI) studies. Using a reference standard, we determined that 33 of the nodules were DNs and that 79 were true HCCs. Tumor size, signal intensity on precontrast T1-weighted images (T1WI) and T2WI, and the pattern of dynamic enhancement on MR images taken in the hepatocyte-phase were determined.

Results

There were significant differences in tumor size, hyperintensity on T2WI, hypointensity on T1WI, typical HCC enhancement pattern on dynamic MR images, or hypointensity on hepatocyte-phase images between DNs and HCC. The sensitivity and specificity were 60.8% and 87.9% for T2WI, 38.0% and 87.9% for T1WI, 17.7% and 100% for dynamic MR imaging, 83.5% and 84.9% for hepatocyte-phase imaging, and 60.8% and 87.9% for tumor size (threshold of 1.7 cm).

Conclusion

Gd-EOB-DTPA-enhanced hepatocyte-phase imaging is recommended for patients at high risk of HCC who present with atypical lesions on dynamic CT images.  相似文献   

17.

Objective

To investigate the accuracy of preoperative computed tomography (CT), magnetic resonance (MR) imaging and diffusion-weighted imaging with background body signal suppression (DWIBS) in the prediction of nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures.

Methods and Materials

Fifty-two subjects with primary rectal cancer were preoperatively assessed by CT and MRI at 1.5 T with a phased-array coil. Preoperative lymph node staging with imaging modalities (CT, MRI, and DWIBS) were compared with the final histological findings.

Results

The accuracy of CT, MRI, and DWIBS were 57.7%, 63.5%, and 40.4%. The accuracy of DWIBS with higher sensitivity and negative predictive value for evaluating primary rectal cancer patients was lower than that of CT and MRI. Nodal staging agreement between imaging and pathology was fairly strong for CT and MRI (Kappa value = 0.331 and 0.348, P<0.01) but was relatively weaker for DWIBS (Kappa value = 0.174, P<0.05). The accuracy was 57.7% and 59.6%, respectively, for CT and MRI when the lymph node border information was used as the criteria, and was 57.7% and 61.5%, respectively, for enhanced CT and MRI when the lymph node enhancement pattern was used as the criteria.

Conclusion

MRI is more accurate than CT in predicting nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. DWIBS has a great diagnostic value in differentiating small malignant from benign lymph nodes.  相似文献   

18.

Purpose

Small injection ports for mice are increasingly used for drug testing or when administering contrast agents. Commercially available mini-ports are expensive single-use items that cause imaging-artifacts. We developed and tested an artifact-free, low-cost, vascular access mini-port (VAMP) for mice.

Procedures

Leakage testing of the VAMP was conducted with high speed bolus injections of different contrast agents. VAMP-induced artifacts were assessed using a micro-CT and a small animal MRI (9.4T) scanner ex vivo. Repeated contrast administration was performed in vivo.

Results

With the VAMP there was no evidence of leakage with repeated punctures, high speed bolus contrast injections, and drawing of blood samples. In contrast to the tested commercially available ports, the VAMP did not cause artifacts with MRI or CT imaging.

Conclusions

The VAMP is an alternative to commercially available mini-ports and has useful applications in animal research involving imaging procedures and contrast agent testing.  相似文献   

19.

Background

Anti-glomerular basement membrane (GBM) antibody disease may lead to acute crescentic glomerulonephritis with poor renal prognosis. Current therapy favours plasma exchange (PE) for removal of pathogenic antibodies. Immunoadsorption (IAS) is superior to PE regarding efficiency of antibody-removal and safety. Apart from anecdotal data, there is no systemic analysis of the long-term effects of IAS on anti-GBM-disease and antibody kinetics.

Objective

To examine the long-term effect of high-frequency IAS combined with standard immunosuppression on patient and renal survival in patients with anti-GBM-disease and to quantify antibody removal and kinetics through IAS.

Design

Retrospective review of patients treated with IAS for anti-GBM-antibody disease confirmed by biopsy and/or anti-GBM-antibodies.

Setting

University Hospital of Vienna, Austria.

Participants

10 patients with anti-GBM-disease treated with IAS.

Measurements

Patient and renal survival, renal histology, anti-GBM-antibodies.

Results

Anti-GBM-antibodies were reduced by the first 9 IAS treatments (mean number of 23) to negative levels in all patients. Renal survival was 40% at diagnosis, 70% after the end of IAS, 63% after one year and 50% at the end of observation (mean 84 months, range 9 to 186). Dialysis dependency was successfully reversed in three of six patients. Patient survival was 90% at the end of observation.

Conclusion

IAS efficiently eliminates anti-GBM-antibodies suggesting non-inferiority to PE with regard to renal and patient survival. Hence IAS should be considered as a valuable treatment option for anti-GBM-disease, especially in patients presenting with a high percentage of crescents and dialysis dependency due to an unusual high proportion of responders.  相似文献   

20.

Background

Patients with chronic known or unknown interstitial lung disease (ILD) may present with severe respiratory flares that require intensive management. Outcome data in these patients are scarce.

Patients and Methods

Clinical and radiological features were collected in 83 patients with ILD-associated acute respiratory failure (ARF). Determinants of hospital mortality and response to corticosteroid therapy were identified by logistic regression.

Results

Hospital and 1-year mortality rates were 41% and 54% respectively. Pulmonary hypertension, computed tomography (CT) fibrosis and acute kidney injury were independently associated with mortality (odds ratio (OR) 4.55; 95% confidence interval (95%CI) (1.20–17.33); OR, 7.68; (1.78–33.22) and OR 10.60; (2.25–49.97) respectively). Response to steroids was higher in patients with shorter time from hospital admission to corticosteroid therapy. Patients with fibrosis on CT had lower response to steroids (OR, 0.03; (0.005–0.21)). In mechanically ventilated patients, overdistension induced by high PEEP settings was associated with CT fibrosis and hospital mortality.

Conclusion

Mortality is high in ILD-associated ARF. CT and echocardiography are valuable prognostic tools. Prompt corticosteroid therapy may improve survival.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号