Citrate is an intermediate in catabolic as well as biosynthetic pathways and is an important regulatory molecule in the control of glycolysis and lipid metabolism. Mass spectrometric and NMR based metabolomics allow measuring citrate concentrations, but only with limited spatial and temporal resolution. Methods are so far lacking to monitor citrate levels in real-time in-vivo. Here, we present a series of genetically encoded citrate sensors based on Förster resonance energy transfer (FRET). We screened databases for citrate-binding proteins and tested three candidates in vitro. The citrate binding domain of the Klebsiella pneumoniae histidine sensor kinase CitA, inserted between the FRET pair Venus/CFP, yielded a sensor highly specific for citrate. We optimized the peptide linkers to achieve maximal FRET change upon citrate binding. By modifying residues in the citrate binding pocket, we were able to construct seven sensors with different affinities spanning a concentration range of three orders of magnitude without losing specificity. In a first in vivo application we show that E. coli maintains the capacity to take up glucose or acetate within seconds even after long-term starvation. 相似文献
2.
3.
Francesca Veronesi Matilde Tschon Andrea Visani Milena Fini 《Journal of cellular physiology》2019,234(12):21504-21518
Biosensors are composed of (bio)receptors, transducers, and detection systems and are able to convert the biological stimulus into a measurable signal. This systematic review evaluates the current state of the art of innovation and research in this field, identifying the biosensors that in vitro monitor the musculoskeletal system cellular processes. Two databases found 20 in vitro studies, from January 1, 2008 to December 31, 2017, dealing with musculoskeletal system cells. The biosensors were divided into two groups based on the transduction mechanism: optical or electrochemical. The first group evaluated osteoblasts or mesenchymal stem cell (MSC) biocompatibility, viability, differentiation, alkaline phosphatase, enzyme, and protein detection. The second group detected cell impedance, ATP release, and superoxide concentration in tenocytes, osteoblasts, MSCs, and myoblasts. This review highlighted that the in vitro scenario is still at an early phase and limited for what concerns both the type of bioanalyte and for the type of system detector used. 相似文献
4.
The development of in vivo working glucose sensors needs two decades, so far. The availability of long term functional implantable biosensors for continuous glucose measurings is a basic prerequisite for the individualized optimum insulin treatment of diabetics. Enzymatic electrochemical sensors are described which realize a functional stability over more than 2 years in vitro, however their function in vivo is limited due to certain bioincompatibility expressed by inflammation of the surrounding tissue, exudates, and immun reactions. The paper reflects an overview concerning different sensor covering materials used as more or less suitable diffusion membranes. From experimental studies in animals and human volunteers conclusions are drawn for further developmental steps of biosensors for in vivo use and for the applicability of glucose sensors for transient diagnostic purposes and as a basis for glucose controlled therapeutic measures. The results demonstrate that further progress aimed at long term biostability of implanted biosensors needs to solve technological problems and the serial production of sensors with really comparable qualities as a prerequisite for clinical trials. 相似文献
5.
6.
《Trends in biotechnology》2002,20(8):S19-S23
Recent developments in in vivo imaging using optical, radionuclide and paramagnetic reporter probes now enables continuous measurements of gene expression in living animals. In vivo bioluminescence imaging (BLI) is a sensitive, versatile and accessible imaging strategy that has been applied to a variety of small-animal models of human biology and disease. We discuss current strategies in BLI and the potential of combining BLI with other in vivo and ex vivo techniques. BLI will have a significant role in in vivo cellular and molecular imaging, a field that will help reveal the molecular basis of biology and disease. 相似文献
7.
When walking long distances, hip prostheses heat up due to friction. The influence of articulating materials and lubricating properties of synovia on the final temperatures, as well as any potential biological consequences, are unknown. Such knowledge is essential for optimizing implant materials, identifying patients who are possibly at risk of implant loosening, and proving the concepts of current joint simulators. An instrumented hip implant with telemetric data transfer was developed to measure the implant temperatures in vivo. A clinical study with 100 patients is planned to measure the implant temperatures for different combinations of head and cup materials during walking. This study will answer the question of whether patients with synovia with poor lubricating properties may be at risk for thermally induced bone necrosis and subsequent implant failure. The study will also deliver the different friction properties of various implant materials and prove the significance of wear simulator tests. A clinically successful titanium hip endoprosthesis was modified to house the electronics inside its hollow neck. The electronics are powered by an external induction coil fixed around the joint. A temperature sensor inside the implant triggers a timer circuit, which produces an inductive pulse train with temperature-dependent intervals. This signal is detected by a giant magnetoresistive sensor fixed near the external energy coil. The implant temperature is measured with an accuracy of 0.1°C in a range between 20°C and 58°C and at a sampling rate of 2-10 Hz. This rate could be considerably increased for measuring other data, such as implant strain or vibration. The employed technique of transmitting data from inside of a closed titanium implant by low frequency magnetic pulses eliminates the need to use an electrical feedthrough and an antenna outside of the implant. It enables the design of mechanically safe and simple instrumented implants. 相似文献
8.
Matthew B. Robers Brock F. Binkowski Mei Cong Chad Zimprich Cesear Corona Mark McDougall George Otto Christopher T. Eggers Jim Hartnett Thomas Machleidt Frank Fan Keith V. Wood 《Analytical biochemistry》2015
Ligand-mediated endocytosis is a key autoregulatory mechanism governing the duration and intensity of signals emanating from cell surface receptors. Due to the mechanistic complexity of endocytosis and its emerging relevance in disease, simple methods capable of tracking this dynamic process in cells have become increasingly desirable. We have developed a bioluminescent reporter technology for real-time analysis of ligand-mediated receptor endocytosis using genetic fusions of NanoLuc luciferase with various G-protein-coupled receptors (GPCRs). This method is compatible with standard microplate formats, which should decrease work flows for high-throughput screens. This article also describes the application of this technology to endocytosis of epidermal growth factor receptor (EGFR), demonstrating potential applicability of the method beyond GPCRs. 相似文献
9.
Biosensors for process control 总被引:1,自引:0,他引:1
S. L. Brooks I. J. Higgins J. D. Newman A. P. F. Turner 《Enzyme and microbial technology》1991,13(12):946-955
Biosensors have been extensively studied during the last 20 years, and a myriad of laboratory biosensors have been developed. Improvements are required in biosensor design and performance before they become widely accepted in industrial process monitoring. However, as the biotechnology industry expands, biosensors may become more acceptable because, despite their limitations, they are the only devices capable of delivering the information required. 相似文献
10.
11.
At present, most biomarker testing is taking place at centralised dedicated laboratories using large, automated analysers, increasing waiting time and costs. Smaller, faster and cheaper devices are highly desired for replacing these time-consuming laboratory analyses and for making analytical results available at the patient's bedside (point-of-care diagnostics). Innovative biosensor-based strategies could allow biomarkers to be tested reliably in a decentralised setting, although several challenges and limitations remain, which need to be improved, in the design and application of biosensors for the appropriate interpretation of the identified and quantified biomarkers. The development of biosensors is probably one of the most promising ways to solve some of the problems concerning the increasing need to develop highly sensitive, fast and economic methods of analysis in medical diagnostics. In this review, some consideration will be given to biosensors and their application in medical diagnostics, taking into account several crucial features. 相似文献
12.
Thomas Scheper 《Journal of industrial microbiology & biotechnology》1992,9(3-4):163-172
Summary A short review about the biosensor research activities for bioprocess monitoring in the F.R.G. after its reunification is given. The principles of biosensor applications are presented. In situ sensors and sensors based on the principles of flow injection analysis are studied. Some applications of a four-channel enzyme thermistor, bio-field effect transistors, and immunoanalysis systems for real process monitoring are presented. 相似文献
13.
Biosensors for environmental monitoring 总被引:9,自引:0,他引:9
Increasing environmental legislation which controls the release and the levels of certain chemicals in the environment has created a need for reliable monitoring of these substances in air, soil and especially water. Conventional analytical techniques, although highly precise, suffer from the disadvantages of high cost, the need for trained personnel and the fact that they are mostly laboratory bound. Biosensors because of their specificity, fast response times, low cost, portability, ease of use and a continuous real time signal, can present distinct advantages in certain cases. Their biological base makes them ideal for toxicological measurements which are suited for health and safety applications. Over the last 3-4 years there has been an increase in the number of publications concerning biosensors for environmental monitoring, especially in the field of pesticide measurements.This paper reviews some of the more important developments over the past 3-4 years. 相似文献
14.
Biosensors for heavy metals 总被引:3,自引:0,他引:3
A biosensor is an analytical device that consists of an immobilized biocomponent in conjunction with a transducer, and represents a synergistic combination of biotechnology and microelectronics. This review summarizes the use of biosensors for detecting and quantifying heavy metal ions. Heavy metal contamination is of serious concern to human health since these substances are non-biodegradable and retained by the ecological system. Conventional analytical techniques for heavy metals (such as cold vapour atomic absorption spectrometry, and inductively coupled plasma mass spectrometry) are precise but suffer from the disadvantages of high cost, the need for trained personnel and the fact that they are mostly laboratory bound. Biosensors have the advantages of specificity, low cost, ease of use, portability and the ability to furnish continuous real time signals. The analysis of heavy metal ions can be carried out with biosensors by using both protein (enzyme, metal-binding protein and antibody)-based and whole-cell (natural and genetically engineered microorganism)-based approaches.Published online: March 2005 相似文献
15.
16.
Christopher R. Lowe 《Trends in biotechnology》1984,2(3):59-65
Two decades of research into biosensors has been accelerated recently by the commercial potential offered by biotechnology. New developments in biosensor technology in which a biologically sensitive material is immobilized in intimate contact with a suitable potentiometric, amperometric, optical or other transducer are described. It is expected that some of these devices will be commercialized in 1984. 相似文献
17.
Calibration of Pd-porphyrin phosphorescence for oxygen concentration measurements in vivo 总被引:2,自引:0,他引:2
Sinaasappel, M., and C. Ince. Calibration ofPd-porphyrin phosphorescence for oxygen concentration measurements in vivo. J. Appl. Physiol. 81(5):2297-2303, 1996.Quantitative measurement of oxygenconcentrations in the microvasculature is of prime importance in issuesrelated to oxygen transport to tissue. The introduction of thequenching of the Pd-porphyrin phosphorescence as oxygen sensor in vivoby Wilson et al. (J. Appl. Physiol.74: 580-589, 1993) has provided in this context a major advance inthis area of research. For in vivo application, the dye is coupled toalbumin to restrict the dye to the circulation and to measure oxygen in the physiological range. In this study a phosphorimeter with a gatedphotomultiplier is presented and validated. Furthermore, anonlinear-fit method using the Marquardt-Levenberg algorithm is used tocalculate the decay time. With this new phosphorimeter, calibrationmeasurements were performed to investigate the effects of pH,temperature, and diffusivity. The results present a preparation methodfor albumin coupling of the dye that eliminates the pH dependency ofthe quenching kinetics. Furthermore, the decreased oxygen diffusivityof serum was compared with that of water, and it was shown thatcalibration constants measured in water can be extrapolated to serum. 相似文献
18.
In this article we will outline several biosensor applications which may fill existing technology gaps in the area of environmental monitoring. The requirements for these environmental biosensors, as well as difficulties in commercialization, are also addressed. 相似文献
19.
20.
C R Lowe 《Philosophical transactions of the Royal Society of London. Series B, Biological sciences》1989,324(1224):487-496
Biosensors are analytical devices that respond selectively to analytes in an appropriate sample and convert their concentration into an electrical signal via a combination of a biological recognition system and an electrochemical, optical or other transducer. Such devices will find application in medicine, agriculture, environmental monitoring and the bioprocessing industries. The last few years have seen great advances in the design of sensor architectures, the marriage of biological systems with monolithic silicon and optical technologies, the development of effective electron-transfer systems and the configuration of direct immunosensors. Recent progress in these areas has already led to the introduction of new-generation biosensors into the competitive diagnostics market place. 相似文献