首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND AND PURPOSE: Staphylococcus aureus is an important cause of intravascular catheter-associated bacteremia. We developed a rat central venous catheter (CVC)-associated infection model to study pathogenesis and treatment. METHODS: A silastic lumen-within-lumen catheter and rodent-restraint jacket were designed. Subcutaneously tunneled catheters were inserted in the jugular vein of 20 male Sprague Dawley rats. Twelve rats (group 1) were inoculated with S. aureus via the CVC; three rats (group 2) were inoculated with S. aureus via the tail vein, five rats (group 3) served as uninfected controls; and three rats (group 4) were inoculated with S. aureus via the tail vein but did not undergo CVC insertion. Five to eight days after inoculation, animals were euthanized, CVCs were aseptically removed, and quantitative culture was done. Quantitative culture also was performed on blood, heart, liver, lungs, and kidneys. RESULTS: Infection, characterized by bacteremia and metastatic disease, was observed in all rats inoculated via the CVC with as few as 100 colony-forming units (CFU) of S. aureus. Rats of group 2 were not as likely to develop CVC-associated infection, and none of the animals of groups 3 or 4 developed infection. CONCLUSIONS: This model of CVC-associated infection should prove suitable for studying pathogenesis and treatment of the condition.  相似文献   

2.
The objective of the study was to evaluate the performance of an amperometric enzyme based lactate sensor and to investigate the possibility of replacing a double lumen catheter based blood withdrawal system with a heparin coated single lumen system. The inner lumen of a double lumen catheter which was placed in a peripheral vein was perfused with heparin solution. The outer lumen was used to collect heparinized blood samples at a defined flow rate. The single lumen system was attached to a heparinized catheter which was also placed in a peripheral vein. The undiluted blood samples were collected at a specified flow rate. A sensor flow chamber incorporating an amperometric thin-film lactate microbiosensor was placed in the sampling line for real-time lactate monitoring. Plasma lactate concentrations were measured during frequently performed hyperlactatemia bicycle ergometer experiments in six healthy volunteers (age 25.8±2.8 years, BMI 22.7±1 kg/m2). Additionally, plasma lactate was measured in real-time using the lactate sensors. The first three experiments were performed with a double lumen based catheter system whereas the following three experiments were performed with a heparin coated catheter system. The correlation coefficients of sensor readings and laboratory analyzer results in all six experiments were between 0.93 and 0.99, respectively (P<0.001). The miniaturized lactate sensors showed a linear range up to 25 mmol/l lactate concentration and 95% response times <30 s in undiluted serum. During the experiments maximum lactate concentrations of 14 mmol/l were achieved. Improvements of system performance using heparin coated catheter systems could be shown. The overall SD of the sensor readings compared to laboratory results using three double lumen catheter based systems was 0.91 mmol/l whereas the SD using three heparin coated systems was 0.65 mmol/l. In summary, real-time monitoring of lactate in human whole blood is feasible with such a device and can be improved by using heparin coated catheter systems.  相似文献   

3.
The aim of this study was to compare the in vitro activity and the impact on bacterial adhesion of two different catheters, one impregnated with chlorhexidine-silver sulfadiazine (C-SS) and the other not impregnated with antibacterial agents. The antimicrobial coating prevented the bacterial colonization by slime positive Staphylococcus epidermidis in the first two days. The antibacterial activity of the effluents from catheters impregnated with C-SS dissipated by day seven. Our results demonstrated that the surface treatment modified the composition of impregnated catheters and determined different contact angle values of the two catheters (impregnated and not impregnated). Examination of coated and uncoated catheter segments by scanning electron microscopy showed a good correlation with the results of adherence experiments. In conclusion, the findings suggest that C-SS coated catheters prevent in vitro bacterial adhesion.  相似文献   

4.
Mongrel dogs were fitted with indwelling hepatic portal catheters. After recovery from surgery, experiments were conducted in fasting, unrestrained, fully conscious, normal dogs which were accustomed to handling and withdrawal of blood samples. L-Tryptophan, a specific serotonin precursor, was injected into a saphenous vein, 10 microM/kg body weight, dissolved in saline. Plasma serotonin, dopamine, norepinephrine, and epinephrine were determined by radioenzymatic assays in blood samples withdrawn at frequent intervals for 2 h, simultaneously from the indwelling catheter and from a catheter temporarily inserted into a saphenous vein other than the one used for the injection of tryptophan. The injection of the amino acid caused a significant elevation of the concentration of platelet-free serotonin within 60 min and this was accompanied by a reduction in the concentration of the catecholamines, dopamine, norepinephrine, and epinephrine. The changes occurred only in the portal circulation and were not detected in peripheral blood samples. The results of these experiments indicate the existence of a cause and effect related interdependence between the splanchnic serotonergic and adrenergic systems in that the tryptophan-stimulated increase in serotonergic activity resulted in a concomitant reduction in gut adrenergic activity.  相似文献   

5.

Background

Approximately 150 million central venous catheters (CVC) are used each year in the United States. Catheter-related bloodstream infections (CR-BSI) are one of the most important complications of the central venous catheters (CVCs). Our objective was to compare the in-hospital mortality when the catheter is removed or not removed in patients with CR-BSI.

Methods

We reviewed all episodes of CR-BSI that occurred in our intensive care unit (ICU) from January 2000 to December 2008. The standard method was defined as a patient with a CVC and at least one positive blood culture obtained from a peripheral vein and a positive semi quantitative (>15 CFU) culture of a catheter segment from where the same organism was isolated. The conservative method was defined as a patient with a CVC and at least one positive blood culture obtained from a peripheral vein and one of the following: (1) differential time period of CVC culture versus peripheral culture positivity of more than 2 hours, or (2) simultaneous quantitative blood culture with 5∶1 ratio (CVC versus peripheral).

Results

53 CR-BSI (37 diagnosed by the standard method and 16 by the conservative method) were diagnosed during the study period. There was a no statistically significant difference in the in-hospital mortality for the standard versus the conservative method (57% vs. 75%, p = 0.208) in ICU patients.

Conclusion

In our study there was a no statistically significant difference between the standard and conservative methods in-hospital mortality.  相似文献   

6.
Many physiologic and pharmacologic studies require long-term vascular access for repeated substance infusion and/or blood sample collection. The study reported here was undertaken to determine whether a functionally active heparin coating would improve long-term patency of venous catheters in rats. Uncoated or coated catheters were surgically placed in the jugular vein, and patency was evaluated twice weekly for a total of 30 days. Culturing of blood and catheters, and histologic examination were performed for all rats. All heparin-coated catheters remained patent for the study duration, with patency defined as ability to infuse saline and withdraw a blood sample. Median patency for uncoated catheters was 17.5 days, with a range of three to 30 days. Histologic evaluation of vessels revealed more advanced and severe lesions in rats with uncoated, compared with coated catheters. Furthermore, uncoated catheters had increased association with bacteremia (3/8), compared with coated (0/9) catheters. Taken together, these results indicate that coating catheters with covalently bound heparin molecules can significantly prolong patency and cause less pathologic damage to the catheterized vessel.  相似文献   

7.
Short peripheral catheter thrombophlebitis (SPCT), a sterile inflammation of the vein wall, is the most common complication associated with short peripheral catheters (SPCs) and affects up to 80% of hospitalized patients receiving IV therapy. Extensive research efforts have been devoted for improvement and optimization of the catheter material, but means for examination of any novel design are limited, inaccurate and require costly comprehensive pre-clinical and clinical trials. Therefore, there is a conclusive need for a reliable quantitative method for evaluation of SPCT, in particular for research purposes examining the thrombophlebitis-related symptoms of any novel catheter design. In this study, we developed for the first time a quantitative MRI based tool for evaluation of SPCT. The extent and severity of SPCT caused by two different commercially available SPCs with known predisposition for thrombophlebitis, were studied in a rabbit model. MRI analysis was consistent with the standardized pathology evaluation and showed remarkable difference in the percent of edema between the experimental groups. These differences were in line with previous studies and provide evidence that this type of analysis may be useful for future assessment of SPCT in vivo. As a non-invasive method, it may constitute a cost effective solution for examination of new catheters and other medical devices, thereby reducing the need for animal sacrifice.  相似文献   

8.
OBITUARIES     
A study of 300 patients receiving intravenous therapy showed that 90 had associated phlebitis. Because of this high rate of complications, the use of long plastic catheters, with the tip located in a large central vessel, was investigated. One hundred and one catheters were inserted into the basilic vein through a cut-down. The patients were divided into four groups: infusions lasting one to seven days, eight to 14 days, 15 to 28 days and 29 days or longer. The most common complication was obstruction of the catheter with clotted blood. In four patients the catheters had to be removed because of phlebitis; two were pulled out by the patients themselves. Infection was not observed. Two factors probably contributed to the successful infusions: the composition of the plastic catheters (nylon) and the location of the tip in a large central vessel.  相似文献   

9.
A frequently debated question for studies involving the measurement of stress hormones in rodents is the optimal method for collecting blood with minimal stress to the animal. Some investigators prefer the implantation of indwelling catheters to allow for frequent sampling. Others argue that the implantation of a catheter creates a chronic stress to the animal that confounds stress hormone measures and therefore rely on tail vein sampling. Moreover, some investigators measure hormones in trunk blood samples obtained after anesthesia, a practice that may itself raise hormone levels. To address these controversies, we 1) compared plasma ACTH and corticosterone (Cort) concentrations in pre- and poststress rat blood samples obtained via previously implanted vena cava catheters, tail vein nicks, or clipping the tip off the tail and 2) compared plasma ACTH and Cort in rat blood samples obtained by decapitation with and without anesthesia. Rats sampled via indwelling catheters displayed lower prestress ACTH levels than those sampled by tail vein nick if the time to acquire samples was not limited; however, elevated basal ACTH was not observed in samples obtained by tail clip or tail nick when the samples were obtained within 3 min. Baseline Cort levels were similar in all groups. After restraint stress, the profile of the plasma ACTH and Cort responses was not affected by sampling method. Decapitation with prior administration of CO2 or pentobarbital sodium increased plasma ACTH levels approximately 13- and 2-fold, respectively, when compared with decapitation without anesthesia. These data indicate that tail vein nicking, tail clipping, or indwelling venous catheters can be used for obtaining plasma for ACTH and Cort during acute stress studies without confounding the measurements. However, the elevation in basal ACTH seen in the tail vein nick group at baseline suggests that sampling needs to be completed rapidly (<3 min) to avoid the initiation of the pituitary stress response. Death by CO2 and pentobarbital sodium injection before trunk blood collection cause significant stress to animals, as reflected in the elevated plasma ACTH levels. These results support the use of either chronic vascular cannulas or sampling from a tail vein. However, collection of blood under pentobarbital sodium or CO2 anesthesia is likely to confound the results of stress studies when ACTH is an important endpoint.  相似文献   

10.
Formation of fibrin sleeves around catheter tips is a central factor in catheter failure during chronic implantation, and such tissue growth can occur despite administration of anticoagulants. We developed a novel method for monitoring catheter patency. This method recognizes the progressive nature of catheter occlusion, and tracks this process over time through measurement of changes in catheter resistance to a standardized 1 mL bolus infusion from a pressurized reservoir. Two indirect measures of catheter patency were used: (a) reservoir residual pressure and (b) reservoir discharge time. This method was applied to the study of catheter patency in rats comparing the effect of catheter material (silastic, polyurethane, Microrenathanetrade mark), lock solution (heparin, heparin/dexamethasone) and two different cannulation sites (superior vena cava via the external jugular vein, inferior vena cava via the femoral vein). Our findings reveal that application of flexible smaller-size silastic catheters and a dexamethasone lock solution resulted in prolonged catheter patency. Patency could be maintained over nine weeks with the femoral vein catheters, compared with five weeks with the external jugular vein catheters. The current method for measuring catheter patency provides a useful index for the assessment of tissue growth around the catheter tip. The method also provides an objective and quantitative way of comparing changes in catheter patency for different surgical methods and catheter types. Our method improves on the conventional method of assessing catheter occlusion by judging the ability to aspirate from the catheter.  相似文献   

11.
Skin bacteria at peripheral intravenous catheter (PIVC) insertion sites pose a serious risk of microbial migration and subsequent colonisation of PIVCs, and the development of catheter related bloodstream infections (CRBSIs). Common skin bacteria are often associated with CRBSIs, therefore the bacterial communities at PIVC skin sites are likely to have major implications for PIVC colonisation. This study aimed to determine the bacterial community structures on skin at PIVC insertion sites and to compare the diversity with associated PIVCs. A total of 10 PIVC skin site swabs and matching PIVC tips were collected by a research nurse from 10 hospitalised medical/surgical patients at catheter removal. All swabs and PIVCs underwent traditional culture and high-throughput sequencing. The bacterial communities on PIVC skin swabs and matching PIVCs were diverse and significantly associated (correlation coefficient = 0.7, p<0.001). Methylobacterium spp. was the dominant genus in all PIVC tip samples, but not so for skin swabs. Sixty-one percent of all reads from the PIVC tips and 36% of all reads from the skin swabs belonged to this genus. Staphylococcus spp., (26%), Pseudomonas spp., (10%) and Acinetobacter spp. (10%) were detected from skin swabs but not from PIVC tips. Most skin associated bacteria commonly associated with CRBSIs were observed on skin sites, but not on PIVCs. Diverse bacterial communities were observed at skin sites despite skin decolonization at PIVC insertion. The positive association of skin and PIVC tip communities provides further evidence that skin is a major source of PIVC colonisation via bacterial migration but microbes present may be different to those traditionally identified via culture methods. The results provide new insights into the colonisation of catheters and potential pathogenesis of bacteria associated with CRBSI, and may assist in developing new strategies designed to reduce the risk of CRBSI.  相似文献   

12.
The objective of this study was to examine a possible difference in progesterone concentrations between the systemic venous blood and the caudal vena cava in early pregnant gilts. Nineteen crossbred pregnant gilts were offered three different regimens of feeding to examine influence of feeding on the secretion pattern of progesterone. The groups were high (H-H), low (L-L) and low-high (L-H) receiving 3.6, 1.8 and 1.8/3.6 kg/day, respectively. Catheters were placed in a jugular vein and the caudal vena cava (to sample ovarian secretion) on day 19 of pregnancy. Two consecutive samples taken at 30-min intervals were collected four times a day for 5 days (days 20-24). In addition, three gilts were simultaneously sampled from both catheters at 30-min intervals for 12 h on day 22. Progesterone concentration was significantly lower in the jugular vein compared with the caudal vena cava in all three feeding groups (P<0.001). An indication of episodic pattern of progesterone production occurred in plasma collected from the caudal vena cava, but not from the jugular vein. Dietary intake did not cause a profound effect on plasma progesterone concentrations during days 20-24 of gestation. It seemed that ovarian progesterone was released into the vena cava in an episodic pattern and there were implications that these episodes were temporally associated with LH pulses.  相似文献   

13.
A jacket and tethering system was used to maintain chronic catheters in monkeys, which provided catheter access and manipulability without further restraint. Surgical placement of catheters and a temperature probe allowed for a common cutaneous exit and interface with the jacket and tether. Monkeys were fitted in a sterile leather or denim jacket which was attached to a sterilized flexible stainless steel cable. Through this conduit, an indwelling temperature probe, as well as catheters from the internal jugular and femoral veins, were attached to a swivel unit located on the upper portion of the cage. The internal jugular catheter was used for the continuous infusion of support solution. The catheter from the femoral vein was maintained with a heparin lock and used for serial blood sampling. Using this system, it was possible to obtain frequent blood samples and body temperature readings, and to administer a continuous intravenous infusion without chemical or excessive physical restraint. To date, 367 monkeys, 322 cynomolgus (Macaca fasicularis), 16 rhesus (Macaca mulatta), and 21 African green (Cercopithecus aethiops) have been studied using this procedure.  相似文献   

14.
Research using rats sometimes requires long-term placement of catheters in the subarachnoid space, the cavity between the arachnoid mater and the pia mater in the brain. These catheters can be used to experimentally induce subarachnoid bleeding by injecting blood or to locally administer drugs or other substances. To date, published techniques for penetrating the subarachnoid space of small experimental animals require the use of inflexible or relatively inflexible catheters. These catheters typically consist of metal or stiff plastic and are used to access the occipital or frontal cranial cavity or to directly access the cisterna magna via the atlantooccipital membrane. However, inflexible catheters are not ideal for long-term placement in the subarachnoid space. In this paper, the authors describe a reliable procedure for long-term catheterization of the subarachnoid cavity of the rat. For this method, personnel insert the catheter and keep it in place in the rat's middle cranial cavity, in the vicinity of the cerebral arterial circle. This new approach allows personnel to repeatedly use the catheter for a period of at least 2 weeks. The catheter, which is well-tolerated by rats, can be used for administering saline solutions and for injecting blood that has not been treated with heparin into the subarachnoid space.  相似文献   

15.
Development of catheter-tract infections in experimental animals can have devastating consequences on animal health and the functional lifespan of surgical implants. To measure the incidence of catheter-tract infections in animals with exteriorized intravenous catheters in this facility and assess the effects of these infections on mean catheter lifespan, health records of 31 Macaca mulatta with catheters were reviewed. Records spanned the interval of January 1, 1996 through October 1, 1997. Catheter-tract infections in 16 of 53 (30.2%) monkeys with catheters were diagnosed based on a combination of clinical signs of infection and results of bacterial culture. Segmental catheter-tract infections reduced mean catheter lifespan to 147 days, compared with 354 days for uninfected catheters. Exit-wound, local tunnel, and surgical-site infections did not significantly reduce catheter lifespan. Bacterial culture reports documented 31 isolates; 41.9% (13 of 31) were coagulase-negative staphylococci, and 22.6% (7 of 31) were Staphylococcus aureus. Of 20 isolates tested, 15 (75%) were resistant to methicillin/oxacillin in vitro. Antimicrobial susceptibility testing of methicillin-resistant and methicillin-susceptible isolates indicated that, compared with methicillin-sensitive isolates, methicillin-resistant isolates had a pattern of multiple antibiotic resistance. Catheter-tract infections were common in this colony of rhesus macaques, and clinically severe infections caused a drastic reduction in catheter lifespan. Approximately half (48%) the bacterial isolates were methicillin-resistant gram-positive bacteria.  相似文献   

16.
血管与导管选择对PICC置管引发并发症的影响   总被引:7,自引:0,他引:7  
目的:通过比较PICC置管的血管与导管选择,探讨其对并发症发生率的影响。方法:2005年10月至2006年7月共336例恶性肿瘤病人应用B/BRAUN单腔导管,"可分裂"穿刺针355型173例,257型163例分别选择头静脉、贵要静脉、颈外静脉进行观察。结果:头静脉病人>50%出现并发症,其中30%出现中途拔管;贵要静脉<10%出现并发症,90%完成治疗计划;颈外静脉2例因固定不妥导致导管脱出。结论:在非高速度滴注的情况下,尽量选用小管径的导管;对血管的选择应当首选责要静脉,优选右侧,穿刺点最好过肘关节,其次选择颈外静脉优选右侧;选择PICC置管操作应慎重,操作之前做好详细的评估。  相似文献   

17.
An in vitro antibiotic susceptibility assay for Staphylococcus aureus biofilms developed on 96-well polystyrene tissue culture plates was performed to elucidate the activity of citropin 1.1, rifampin and minocycline. Efficacy studies were performed in a rat model of staphylococcal CVC infection. Silastic catheters were implanted into the superior cava. Twenty-four hours after implantation the catheters were filled with citropin 1.1 (10 microg/mL). Thirty minutes later the rats were challenged via the CVC with 1.0 x 10(6) CFU of S. aureus strain Smith diffuse. Administration of antibiotics into the CVC (the antibiotic lock technique) began 24 h later. The study included: one control group (no CVC infection), one contaminated group that did not receive any antibiotic prophylaxis, one contaminated group that received citropin 1.1-treated CVC, two contaminated groups that received citropin 1.1-treated CVC plus rifampin and minocycline at concentrations equal to MBCs for adherent cells and 1024 microg/mL in a volume of 0.1 mL that filled the CVC and two contaminated groups that received rifampin or minocycline at the same concentrations. All catheters were explanted 7 days after implantation. Main outcome measures were: minimal inhibitory concentration (MIC), minimal bactericidal concentration (MBC), synergy studies, quantitative culture of the biofilm formed on the catheters and surrounding venous tissues, and quantitative peripheral blood cultures. MICs of conventional antibiotics against the bacteria in a biofilm were at least four-fold higher than against the freely growing planktonic cells. In contrast, when antibiotics were used on citropin 1.1 pre-treated cells they showed comparable activity against both biofilm and planktonic organisms. The in vivo studies show that when CVCs were pre-treated with citropin 1.1 or with a high dose of antibiotics, biofilm bacterial load was reduced from 10(7) to 10(3) CFU/mL and bacteremia reduced from 10(3) to 10(1) CFU/mL. When CVCs were treated both with citropin 1.1 and antibiotics, biofilm bacterial load was further reduced to 10(1) CFU/mL and bacteremia was not detected, suggesting 100% elimination of bacteremia and a log 6 reduction in biofilm load. Citropin 1.1 significantly reduces bacterial load and enhances the effect of hydrophobic antibiotics in the treatment of CVC-associated S. aureus infections.  相似文献   

18.
A McGeer  J Righter 《CMAJ》1987,137(11):1009-15,1021
We prospectively studied 45 central venous catheters to determine whether Gram''s staining and culture of skin swabs from the entry site could be used to predict catheter-related infection. Data were collected from insertion site swabs, intracutaneous and intravascular catheter segments, and blood cultures. Surveillance site cultures at the time of dressing changes showed that bacterial growth, once established, persisted until removal of the catheter but that the time of onset of infection was not predictable. Gram''s staining alone and Gram''s staining combined with culture were tested for their ability to predict catheter colonization and catheter-related infection. Bacteria seen with Gram''s staining invariably denoted catheter colonization. When bacteria were not seen with Gram''s staining, positive results of culture did not change the pretest probabilities of colonization or infection; however, negative results of culture reduced the probability of colonization to low levels (likelihood ratio less than 0.06). We conclude that Gram''s staining and culture of skin swabs from the entry site provide, without line removal, a simple, inexpensive and practical test for the diagnosis of catheter-related infection.  相似文献   

19.

Background  

Intravascular catheter related infection (CRI) is one of the most serious nosocomial infections. Diagnostic criteria include a positive culture from the catheter tip along with blood, yet in many patients with signs of infection, current culture techniques fail to identify pathogens on catheter segments. We hypothesised that a molecular examination of the bacterial community on short term arterial catheters (ACs) would improve our understanding of the variety of organisms that are present in this niche environment and would help develop new methods for the diagnosis of CRI.  相似文献   

20.
Eighty-six adult, cyclic, anestrous and postpartum Ile-de-France ewes were placed under general anaesthesia. A catheter was inserted in the utero-ovarian vein (u.o.v.) of one or both ovaries in each ewe. The animals were kept unrestrained in pens and allowed to experience normal maternal behaviour, including suckling. Oestrus was detected with rams. Out of 167 catheters inserted, 70.7% allowed repetitive blood collection, 24.0% were obstructed for short periods and 5.4% remained completly blocked. Oestradiol- 17beta was assayed without extraction from the u.o.v. plasma samples. From these results, we conclude that this technique is suitable for investigating the mechanisms involved in the recovery of cyclical ovarian activity after parturition, particularly because the follicular response to endogenous gonadotropins can be assessed. This is not possible when plasma samples are obtained from a jugular vein.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号