首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Neuropeptide contents of rat brain samples were determined by radioimmunoassay (RIA) after fractionation of tissue extracts by high-performance liquid chromatography (HPLC). Solvent systems were composed of acetic acid, acetonitrile and short-chain (5–8 carbons) alkylsulfonic acids. Separate solvent systems were developed for thyrotropin-releasing hormone, substance P, arginine vasopressin and biologic analogs, and the enkephalins. All separation systems tested gave 80–90% recovery of picogram quantities of peptides. When lyophilized, the HPLC solvents did not interfere significantly with the RIAs, allowing quantitation of tissue concentrations of isolated neuropeptides using the lyophilized eluent from the HPLC. The combination of liquid chromatography with RIA should allow for very accurate identification and quantification of peptides in biologic samples containing large numbers of potentially cross-reacting species of molecules.  相似文献   

2.
A procedure is described for the determination of plasma catecholamines using reversed-phase, ion-pair high-performance liquid chromatography coupled with electrochemical detection. Optimisation of chromatographic conditions with respect to detector performance and adherence to procedures and precautions described, render the method applicable to both neurochemical research and routine clinical analysis. The limit of quantitative detection of the method was found to be approximately 30 pg per injection for individual catecholamines. A single chromatographic run, providing adequate resolution of each component, could be completed in approximately 12 min.  相似文献   

3.
An HPLC method is described for the determination of iodide in serum and urine using ion-pair chromatography with coulometric detection. After adding hexadecyltrimethylammonium chloride, the ions pairs formed with the iodide in the sample are extracted using an organic solvent. The solvent is then evaporated and the dry residue obtained is mixed with an appropriate volume of mobile phase so as to concentrate the sample prior to injection into the chromatograph. For a sample of 0.5 ml of serum, the method features a limit of detection (signal-to-noise ratio of 3) of 0.2 μgl−1, sufficient to be applied in paediatric assays for the diagnosis of both iodide deficiency and excess.  相似文献   

4.
Methods for the fluorescence derivatization of cardiac glycosides with concentrated acids from TLC are adopted to HPLC for post-column derivatization. The column effluent is blended with concentrated acids in a knitted tube reactor, which enables derivatization with negligible increase in chromatographic peak width. The selectivity of the reaction is temperature-dependent and influenced by the respective acid. Reactivity increases from H3PO4→CH3SO3H ≡ H2SO4. The conversion of digoxigenin, digitoxigenin and their digitoxosides is accelerated by Cu(II) acetate or Co(II) nitrate in H2SO4. Combined with a new two-mode, single-column solid-phase sample preparation, cardiac glycoside levels of less than 100 pg/glycoside in 1 ml plasma are detectable.  相似文献   

5.
6.
7.
Singly- and dually-labeled synthetic oligonucleotides were purified by ion-pair reversed-phase high-performance liquid chromatography using a 50x4.6-mm column packed with porous, 2.5 micrometer C(18) sorbent. We studied the mechanism of dye-labeled oligonucleotide retention in order to improve the quality of purification. By-products of oligonucleotide synthesis were characterized by liquid chromatography with mass spectrometry detection (LC-MS). We purified oligonucleotides labeled with 6-carboxyfluorescein (6FAM), hexachlorofluorescein (HEX), tetrachlorofluorescein (TET), carboxytetramethylrhodamine (TAMRA) and indodicarboxycyanine (Cy3) dyes, as well as dually-labeled TaqMan probes. Purification of a 0.1-micromole oligonucleotide synthesis in a single injection was demonstrated.  相似文献   

8.
We have developed an assay for nicotine in hair based on reversed-phase HPLC with electrochemical detection. The method uses a low-metal, high-purity silica reversed-phase column. We have investigated the washing, digestion and extraction procedures and discuss the important points in the HPLC method development. The assay is presented as an application in a population of exposed and non-exposed children. Analytical parameters are satisfactory with linearity, recoveries, limit of quantitation and precision all suitable for epidemiological studies involving environmental tobacco smoke exposure assessment.  相似文献   

9.
One possibility to optimize the therapeutic application of dopaminergic compounds with a catechol function is the reversible protection of this moiety using a prodrug approach. Important features in this respect are a proper chemical stability in the gastrointestinal tract, an adequate release rate after arrival in the blood stream or the possibility to cross the blood–brain barrier. A HPLC method was developed to measure the hydrolysis of prodrugs of dopamine and epinine directly. The method is based on reversed-phase separation followed by post-column ion-pair extraction with a fluorescent counter-ion. The separation of di-isobutyryl esters of dopamine and epinine is obtained within 10 min while the more hydrophobic dopaminergic esters, di-benzoyl and di-pivaloyl dopamine, are retained for 30 min. The precision of the assay measuring 160 ng dibudop and 100 ng ibopamine was 1.2 and 1.0%, respectively. The detection limit of all prodrugs tested was approximately 10 ng.  相似文献   

10.
A simple, rapid and sensitive reversed-phase ion-pair high-performance liquid chromatographic method for the determination of N-acetylneuraminic acid and 2-deoxy-2,3-dehydro-N-acetylneuraminic acid in biological fluids is described. Determination of N-acetylneuraminic acid released by acidic hydrolysis, in serum, urine and saliva, and 2-deoxy-2,3-dehydro-N-acetylneuraminic acid in urine, without hydrolysis, was accomplished by injecting the sample without derivatization, into the chromatograph. Measurements were carried out isocratically within 6 min using a C18 column and a mobile phase of aqueous solution of triisopropanolamine, as ion-pair reagent, 60 mM, pH 3.5 at room temperature with UV absorbance detection. The present method is reported for the first time for the determination of sialic acids in biological fluids. Recoveries in serum, urine and saliva ranged from 90 to 102% and the limits of detection were 60 nM and 20 nM for the two sialic acids, respectively. The method has been applied to normal and pathological sera from patients with breast, stomach, colon, ovarian and cervix cancers, to normal urine and urine from patient with sialuria and to normal saliva.  相似文献   

11.
Sizing of DNA fragments is a routine analysis traditionally performed on agarose or polyacrylamide gels. Electrophoretic analysis is labor-intensive with only limited potential for automation. Recovery of DNA fragments from gels is cumbersome. We present data on automated, size-based separation of DNA fragments by ion-pair reversed-phase high performance liquid chromatography (IP RP HPLC) - DNA chromatography - on the WAVE DNA Fragment Analysis System with the DNASep cartridge. This system is suitable for accurate and rapid sizing of double-stranded (ds) DNA fragments from 50 to ca. 2000 base pairs (bp). Fluorescently labeled DNA fragments are compatible with the technology. Length-dependent separation of dsDNA fragments is sequence independent and retention times are highly reproducible. The resolving capabilities of DNA chromatography are illustrated by the analysis of multiple DNA size markers. Resolved dsDNA fragments are easily collected and are suitable for downstream applications such as sequencing and cloning. DNA chromatography under denaturing conditions with fluorescently labeled DNA fragments offers a means for the separation and purification of individual strands of dsDNA. Analysis of DNA fragments on the WAVE System is highly automated and requires minimal manual intervention. DNA chromatography offers a reliable and automated alternative to gel electrophoresis for the analysis of DNA fragments.  相似文献   

12.
On irradiation with ultraviolet light, the antiinflammatory agent sulindac and its two metabolites sulindac sulfone and sulindac sulfide form highly fluorescent derivatives. This reaction was exploited for the sensitive and selective detection of these compounds in serum using reversed-phase high-performance liquid chromatography on a Ultrasphere octylsilane column (150 × 4.6 mm I.D.) at ambient temperature with a flow-rate of 0.5 ml/min. The analytes of interest were isolated from serum using a Bond-Elut C2 column with satisfactory recovery and selectivity. The detection limits were 10 ng/ml for each of the three analytes using 1 ml of serum and the limit of quantitation was 50 ng/ml. Linear calibration curves from 50 to 1000 ng/ml for all three analytes show coefficients of determination of 0.9999. The post-column ultraviolet irradiation was optimized and the effect of irradiation time on the fluorescence response was determined for all three analytes. Precision and accuracy of the method were 0.4–5.6 and 1.6–4.5% for sulindac, 2.3–5.6 and 1.4–5.3% for sulindac sulfone and 2.5–4.3 and 0.8–2.8% for sulindac sulfide, respectively.  相似文献   

13.
A liquid chromatographic method with on-line activity determination for microperoxidases has been developed. After enzymatic digestion of a cytochrome, possibly under formation of microperoxidases, the product mixture is separated by reversed-phase liquid chromatography. The products first pass a diode-array detector, and are then subjected to a reaction with 4-(N-methylhydrazino)-7-nitro-2,1,3-benzooxadiazole (MNBDH) and hydrogen peroxide. In a reaction coil, microperoxidases catalyze the reaction under formation of the fluorescent 4-(N-methylamino)-7-nitro-2,1,3-benzooxadiazole (MNBDA). Quantification of the microperoxidases is performed using a fluorescence detector at an excitation wavelength of 470 nm and an emission wavelength of 545 nm, respectively. For this LC-based detection system, limits of detection are 3 x 10(-8) mol/L, limits of quantification are 9 x 10(-8) mol/L, and a linear range from 9 x 10(-8) mol/L to 3 x 10(-6) mol/L is obtained for the microperoxidases MP-9 and MP-11. A highly active microperoxidase MP-6 was found in the reaction of cytochrome c from bovine heart with protease from streptomyces griseus.  相似文献   

14.
Tryptophan and many of its indole metabolites were separated using reversed-phase high-performance liquid chromatography (HPLC) and determined using electrochemical detection. This was accomplished isocratically using an acetate—citric acid eluent with various amounts of methanol. Brain and pineal tissue was analyzed for several tryptophan metabolites. Tissue preparation required only homogenization in acidic solution and centrifugation prior to application to the HPLC column. Detection limits in the low picogram range were found for those indoles separated.  相似文献   

15.
16.
A new postcolumn derivatization system using 1,2-naphthoquinone-4-sulfonate as fluorogenic reagent for the fluorometric determination of guanidino compounds is described. The guanidino compounds were separated by reversed-phase ion-pair high-performance liquid chromatography with an isocratic mobile phase containing the fluorogenic reagent and octane-sulfonate as the counterion. Fluorophors were derived from a condensation of guanidino compounds with the fluorogenic reagent in an alkaline solution. The chromatographic system using the mobile phase containing the fluorogenic reagent was simplified because only two pumps were required to deliver the mobile phase and the alkaline solution. Separation of guanidino compounds was completed within 25 min using a Nucleosil C8 column (5 microns, 15 cm X 4.6 mm i.d.). This method was applied to serum obtained from patients on hemodialysis therapy.  相似文献   

17.
Quantitative methods for determination of amoxicillin in body fluids are described. They comprise separation by reversed-phase chromatography (LiChrosorb RP-8, 5 μm) of the aqueous supernatants obtained from plasma or urine after purification steps involving protein precipitation followed by extraction in the case of plasma, or a double extraction procedure in the case of urine, post-column derivatization with air segmentation, and finally measurement of the UV absorbance at 310 nm. The derivatization involves formation of the mercuric mercaptide of penicillenic acid and is specific for compounds with an intact penicillanic acid ring system.Detection limits achieved on injecting 200 μl of plasma and 20 μl of urine are about 25 ng/ml and 200 ng/ml, respectively, but it is possible to improve the sensitivity further by injecting larger volumes. Precisions (srel) obtained for determination of 0.10 and 0.45 μg/ml in plasma were 3.72 and 1.40%, respectively.Some problems regarding column stability originating from the injection of biological samples are discussed.  相似文献   

18.
A method is described for the determination of the neurohormone contents of ovine pineal tissue by radioimmunoassay (RIA) after successive fractionation on gel filtration in formic acid and reverse-phase liquid chromatography (HPLC). This method gives a good resolution for the neurohormones vasopressin, vasotocin and oxytocin, without a significant interference of aspecific cross-reacting of peptides with the RIA. An acid extract from ovine pineal tissue was found to contain amounts of immunoreactive AVP- and OXT-like peptides, whereas an AVT-like peptide was not detectable over background levels after HPLC with post-column RIA. It is concluded from our results that an AVT-like peptide is not present in ovine pineal tissue, and the pineal AVP- and OXT-like peptides appeared to be associated to neurophysin molecules.  相似文献   

19.
A reversed-phase ion-pair HPLC method for separating hyaluronic acid oligomers, using a polymeric C18 column at alkaline pH, is described. As the concentration of the ion-pairing agent tetrabutylammonium hydroxide increased, over the range of 0.01 to 0.06M, the capacity factors (k') of tetra- to dodecasaccharide decreased. The change in k', for each increment in pairing agent, increased with oligomer molecular weight. When changing mobile phase pH from 7 to 8, k' dramatically decreased and remained unchanged from pH 8 to 11. The isocratic separation was optimized to resolve tetrato dodecasaccharide at pH 9.0 in under 19 min. The postcolumn derivatizing agent 2-cyanoacetamide reacted with the reducing N-acetylglucosamine end groups of hyaluronic acid oligomers to yield reaction products that were monitored at 27 nm. In a series of control experiments using decasaccharide and N-acetylglucosamine, it was found that maximum product formation took place at pH 9 and was greatly influenced by borate buffer concentration. The optimum concentration for 2-cyanoacetamide was 0.33% and a temperature of 100 degrees C gave the best signal to noise ratio for the postcolumn reaction. The method is linear and reproducible, and has a lower limit of detection for tetrasaccharide of 20 ng (25 pmol). This system is suitable for studying the degradation kinetics of purified hyaluronic acid oligomers by bovine testicular hyaluronidase. Extension of the method to fluorescent and electrochemical detection and its applicability to other glycosaminoglycans is discussed.  相似文献   

20.
A method capable of separating and quantifying the three major and one minor components of gentamicin in milk has been developed. The method is capable of detecting 15 ng/ml gentamicin, based on a total of the four components. Milk samples are centrifuged at 4°C, the fat layer removed, and the samples deproteinated with 30% trichloracetic acid. After a second centrifugation, the supernatant is passed through a C18 solid-phase extraction column. The column is washed with water, water-methanol (50:50) and methanol. Ammonium hydroxide (16%) in methanol is used to elute the gentamicin. The eluent is evaporated to near dryness and taken up with water. An aliquot of the sample is then mixed with an ion-pairing reagent for chromatography. Separation is achieved using pentanesulfonic acid in a water-methanol mobile phase on a C18 reversed-phase column. The o-phthalaldehyde fluorescence derivatives of gentamicin are formed post-column and are detected with excitation at 340 nm and emission at 430 nm. The percent recovery of gentamicin averaged 72, 78 and 88% from milk samples fortified at 15, 30 and 60 ng/ml, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号