首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Objective

To assess the safety and feasibility of percutaneous cryoablation on pancreatic cancer via ultrasonography (US) and computed tomography (CT) guidance.

Materials and methods

This retrospective review was approved by the institutional review board and of informed consent. Thirty-two patients (18 men and 14 women; median age 62; age range, 30–77 years) with pancreatic cancer (stage II/III/IV, 3/11/18) treated with percutaneous US and CT guided cryoablations between February 2009 and February 2010 were eligible for this review. Thirteen tumors in pancreatic head and 19 in pancreatic body and/or tail measuring 2–11 cm (mean, 5.2 cm ± 8 [standard deviation]) were ablated with 49 procedures in total. Feasibility was analyzed by enhanced CT 1–3 months post procedure and safety was assessed by clinical signs, symptoms and laboratory results.

Results

Neither procedural death nor serious complications occurred. Fifteen tumors (46.9%) smaller than 5 cm were successfully ablated by one session of cryoablation. Twenty-seven patients experienced a ?50% reduction in pain score, 22 experienced a 50% decrease in analgesic consumption and 16 experienced a ?20 increase in Karnofsky Performance Status (KPS) Score. Partial response (PR) and stable disease (SD) turned up in 9 and 21 patients, respectively, lesions in whom were identified controlled by none enhancement on enhanced CT. Mean and median survival was 15.9 and 12.6 months, respectively. The 6-, 12- and 24-month survival rates were 82.8%, 54.7% and 27.3%, respectively.

Conclusion

US and CT guided percutaneous cryoablation is a safe and promising local treatment for pancreatic cancer.  相似文献   

2.
Background and purposeTo study the impact of coronal and sagittal views (CSV) on the gross tumor volume (GTV) delineation on CT and matched PET/CT scans in non-small cell lung cancer.Material and methodsGTV delineations were performed by 11 experienced radiation oncologists on CT and PET/CT in 22 patients. Two tumor groups were defined: Group I: Primary tumors surrounded by lung or visceral pleura, without venous invasion, and without large extensions to the chest wall or the mediastinum. Group II: Tumors invading the hilar region, heart, large vessels, pericardium, and the mediastinum and/or associated with atelectasis. Tumor volumes and inter-observers variations (SD) were calculated and compared according to the use of axial view only (AW), axial/coronal/sagittal views (ACSW) and ACSW/PET (ACSWP).ResultsCSV were not frequently used (57.4% out of 242 delineations on CT). For group I, ACSW didn’t improve significantly mean GTVs. SDs were small on CT and on PET (SD = 0.3 cm). For group II, ACSW had 27–46% smaller observer variation (mean SD = 0.7 cm) than AW (mean SD = 1.1 cm). The smaller observer variation of ACSW users was associated with, on average, a 40% smaller delineated volume (p = 0.038). Mean GTV of ACSWP was 21% larger than mean GTV of ACSW on CT.ConclusionsFor smaller lung tumors surrounded by healthy lung tissue the effect of multiple axis delineation is limited. However, application of coronal and sagittal windows is highly beneficial for delineation of more complex tumors, with atelectasis and/or pathological lymph nodes even if PET is used.  相似文献   

3.
ObjectiveTo assess the feasibility of treatment planning for pancreatic tumours subject to respiratory motion using field-specific target volumes (FTV) and field-specific organs at risk (FOAR) using four-dimensional computed tomography (4DCT).MethodsFourteen pancreatic cancer patients underwent 4DCT. Radiation oncologists contoured the gross tumour volume (GTV), clinical target volume (CTV), spinal cord, duodenum, kidneys, and stomach. The gating duty cycle was set to 30 % around exhalation. FTV and FOAR were calculated using the 4DCT dataset. Planning target volumes (PTV) and planning organs at risk volumes (PRV) were defined as equal to FTV and FOAR, respectively. A dose of 55.2 Gy relative biological effectiveness (RBE) was planned to target the PTV from four beam angles. A single field uniform dose (SFUD) plan was selected. The dose distribution, including intrafractional motion changes, was generated.ResultsThe mean volume of target receiving 95 % of the planned doses was 96.4 ± 4.1 % to the GTV and 94.7 ± 0.9 % to the CTV. The highest dose to 2 cc of duodenal volume was 27.5 Gy (RBE). The volume of the stomach receiving ⩾30 Gy (RBE) was <7.0 cc in all patients. All metrics for OARs satisfied dose constraints.ConclusionDose to the CTV was covered sufficiently by the 4DCT-generated FTV, and dose to OARs was reduced by 4DCT-generated FOAR. This methodology may prevent adverse reactions while preserving local tumour control.  相似文献   

4.
IntroductionTo assess interobserver variability for biological target volume (BTV) delineation and to compare the reproductibility of different semiautomatic segmentation methods in pretreatment 18-fluorodeoxyglucose positron emission tomography (PET/CT) of head and neck squamous cell carcinoma (HNSCC).Patients and methodsPatients with histologically proved HNSCC referred to the nuclear medicine service in Brest for pretreatment PET/CT were prospectively included from February 2009 to June 2010. Three nuclear medicine physicians (two specialized in oncology) delineated manually and independently BTV on each primary tumor. Four semiautomatic segmentation methods have been studied; three using a fixed threshold and one applying an adaptive threshold based on the signal-to-background ratio (Daisne). The variability between κ observers and/or methods has been assessed. The concordance between the various BTV intersections and unions has been also assessed.ResultsThirty patients (29M; 1F) were included. The primary site location was oropharynx in six patients, oral cavity in 10 patients, hypopharynx in five patients and larynx in nine patients. A statistically significant global interobserver variability (P = 0.01) was showed, but without statistically difference between the two experienced oncologists (P = 0.15). The maximal concordance of the two experienced observers with the semiautomatic methods was found for the Daisne method (CI = 61.5%; κ = 0.68), expressing a good agreement according to the Landis and Koch criteria, better than with the segmentation method using a fixed threshold with 40% of maximal signal intensity (CI = 52.1%; κ = 0.53).ConclusionOur results suggest the feasibility of achieving HNSCC BTV delineation by PET/CT using semiautomatic methods, in particular those which apply an adaptative threshold but under the supervision of an experienced operator.  相似文献   

5.
6.
7.
AimTo evaluate the usefulness of a low dose SPECT/CT and the added value of an additional “diagnostic” centred CT-scan in cancer patients with a solitary focus observed on planar whole-body bone scintigraphy (PWBS) and classified as indeterminate or suspicious.Material and methodsSixty consecutive patients underwent a low dose SPECT/CT acquisition (120 kV, 30 mAs, 3 mm slice thickness) followed by a “diagnostic” CT-scan (120 kV, 100 mAs, 1.25 mm slice thickness) centred on the focus. The first observer considered prospectively WBS, low-dose SPECT/CT and finally the centred SPECT/CT. A blinded review was performed by a second observer.ResultsPWBS depicted solitary indeterminate or suspicious foci in 38 and 22 patients, respectively. SPECT/CT acquisitions clarified 73% (44/60) of the foci. Additional diagnostic CT-scan altered low-dose SPECT/CT results in nine patients. Additional foci (not found by PWBS) located outside the scanning area of the centred diagnostic CT-scan were found in 20 patients. Inter observer agreement for PWBS, low-dose SPECT/CT and diagnostic SPECT/CT was equal to 0.542, 0.68 and 0.694, respectively. ROC analysis showed no difference between low-dose SPECT/CT and diagnostic SPECT/CT for observer 1 and observer 2.ConclusionThis study shows that a conventional low-dose SPECT/CT in patients presenting with a solitary focus on PWBS is sufficient to improve both accuracy and inter observer variability of bone scanning. A CT volume session should not be limited to the area of the solitary focus since additional foci located outside the centred CT-scan frequently occurred.  相似文献   

8.
IntroductionOur work aims to compare whole-body diffusion MRI (DWMRI) and 18FDG PET/CT in the diagnosis of symptomatic myeloma.Patients and methodFrom November 2008 till May 2010, 19 patients were investigated by DWMRI and by 18FDG PET/CT. The patients were classified according to the criteria of the International Myeloma Working Group in eight non-symptomatic myelomas and 11 symptomatic myelomas. The sensitivity and the specificity of two methods of imaging were studied by retaining the presence or the absence of a diffuse infiltration (ID), focal lesions (FL), or both parameters (FL + ID), in both modalities of imaging. We compared the concordance between two techniques for every patient by using these signs using a weighted kappa test.ResultsThe performances of both modalities seem comparable, with superior diagnostic performances for the FL (Se = 100% and Sp = 75% in DWMRI and Se = 91% and Sp = 75% for 18FDG PET/CT). By combining both parameters, the 18FDG PET/CT seems more specific, but the sensitivity is comparable in both modalities (Se = 100% in MRI and Se = 100% in 18FDG PET/CT; Sp = 37% in DWMRI and Sp = 62% for 18FDG PET/CT). The concordance between both techniques is better by taking into account the FL than the other parameters (weighted kappa = 0.61 for FL, 0.5 for the FL + ID and 0.16 for ID alone).ConclusionDiagnostic performances of whole-body diffusion MRI and 18FDG PET/CT seem equivalent, but concordance between both techniques is imperfect. Further studies are necessary to understand this discrepancy.  相似文献   

9.
The aim of this study is to assess a new tool for the diagnosis of acute pulmonary embolism (PE): single-photon emission computed tomography lung perfusion imaging associated with unenhanced computed tomography (SPECT/CT) compared to planar ventilation-perfusion (VQ) lung scintigraphy.MethodsOne hundred and three patients with suspected acute PE underwent VQ scintigraphy (two scans were uninterpretable) followed by perfusion SPECT/CT. The two types of images were analysed separately: (1) according to the modified PIOPED scintigraphic criteria for VQ lung scan and (2) with regard to SPECT/CT mismatches suggestive acute PE (segmental perfusion defects detected on SPECT images not matched with CT abnormalities).ResultsOn average, the number of segmental perfusion defects per patient was higher with SPECT/CT than with planar scintigraphy (4.3 ± 3.6 versus 2.8 ± 2.6; p < 0.001). A mismatch was found with SPECT-CT in 0% (0/18) of normal scintigraphy, and 8% (3/39) for low, 32% (8/25) for intermediate and 74% (14/19) for high probabilities of PE at scintigraphy. The presence of a SPECT/CT mismatch was also associated with higher pretest probability of acute PE (p = 0.001), even for the 25 patients in the intermediate-probability subgroup (p = 0.02). Finally, a SPECT/CT match was found in 29 patients that was not suggestive of acute PE due to the presence, in areas with perfusion defects on SPECT images, of the following CT abnormalities: hypodensity and/or emphysema (71%), condensation or atelectasis (38%), pleural disease (7%), extrapulmonary structure (14%) and/or bronchial obstruction (7%).ConclusionIn patients with suspected acute PE, the results obtained with pulmonary SPECT/CT images are consistent with those obtained with VQ scintigraphy and the pretest probability of PE. Further studies comparing SPECT/CT imaging with angiographic techniques are now required to evaluate more specifically the diagnostic value of this new tool.  相似文献   

10.
IntroductionWe evaluated the impact of 4DCT artifacts on carbon-ion pencil beam scanning dose distributions in lung and liver treatment.Methods & materials4DCT was performed in 20 liver and lung patients using area-detector CT (original 4DCT). 4DCT acquisition by multi-detector row CT was simulated using original 4DCT by selecting other phases randomly (plus/minus 20% phases). Since tumor position can move over the respiratory range in original 4DCT, mid-exhalation was set as reference phase. Total prescribed dose of 60 Gy (RBE) was delivered to the clinical target volume (CTV). Reference dose distribution was calculated with the original CT, and actual dose distributions were calculated with treatment planning parameters optimized using the simulated CT (simulated dose). Dose distribution was calculated by substituting these parameters into the original CT.ResultsFor liver cases, CTV-D95 and CTV-Dmin values for the reference dose were 97.6 ± 0.5% and 89.8 ± 0.6% of prescribed dose, respectively. Values for the simulated dose were significantly degraded, to 88.6 ± 14.0% and 46.3 ± 26.7%, respectively. Dose assessment results for lung cases were 84.8 ± 12.8% and 58.0 ± 24.5% for the simulated dose, showing significant degradation over the reference dose of 95.1 ± 1.5% and 87.0 ± 2.2%, respectively.Conclusions4DCT image quality should be closely checked to minimize degradation of dose conformation due to 4DCT artifacts. Medical staff should pay particular attention to checking the quality of 4DCT images as a function of respiratory phase, because it is difficult to recognize 4DCT artifact on a single phase in some cases  相似文献   

11.
《Médecine Nucléaire》2014,38(2):71-82
PurposeWe investigated the prognostic significance of F-18 fluorodeoxyglucose (FDG) uptake measured as maximum Standardized Uptake Value (SUVmax) in primary tumor by positron emission tomography/computed tomography (PET/CT) in cervical cancer. The secondary objective was to determine the accuracy of the PET/CT for detecting pelvic lymph node (PLN) and para-aortic lymph node (PALN) metastases.MethodsThis retrospective study included 49 consecutive patients with stage IB1 to IVB cervical cancer. Univariate analysis was performed to determine the relationships between SUVmax value and pathological prognostics factors. Survival was estimated by Kaplan-Meier method. The gold standard of LN metastases was histologic.ResultsA significant difference in SUVmax was observed between stage I and stage II, stage I and stage IV and tumor size ≤ 4 cm and > 4 cm (P = 0.0001). There was a significant correlation between the SUVmax and tumor maximal size (r = 0.597) (P < 0.0001). PLN metastasis was found to be predictive of progression-free survival (P = 0.0007). The negative predictive value (NPV) of the PET/CT for PALN was 100% for locally advanced cervical carcinoma in 24 patients. The specificity and NPV of the PET/CT for PLN in eight early-stage cervical cancer were 100% and 87.5% (7/8) respectively. The PET/CT false-negative PLN measured less than 2 mm.ConclusionOur results demonstrate a correlation between SUVmax and tumor maximal size, which represents an indicator of tumor aggressiveness. PET/CT is effective to predict the absence of PALN in locally advanced cervical carcinoma. PET/CT is not sufficient to predict PLN in early-stage cancer without lymphadenectomy.  相似文献   

12.
AimPublished data on the association between transforming growth factor-β1 (TGF-β1) gene promoter-509C/T polymorphism and colorectal cancer (CRC) risk are inconsistent and inconclusive. To derive a more precise estimation of this association, a meta-analysis was carried out.MethodsMeta-analysis was performed to evaluate reported studies of the relationship between TGF-β1 gene promoter-509C/T polymorphism and colorectal cancer risk using fixed-effects model and random-effects model.ResultsWe observed an increased colorectal cancer risk among subjects carrying TGF-β1 gene promoter-509CC + CT genotype (odds ratio (OR) = 1.18%, 95% confidence interval (95% CI): 1.06–1.32) using 4440/6785 cases/controls in total population. We observed an increased risk of the TGF-β1 gene promoter -509CC, CT and CC + CT polymorphisms for colorectal cancer in population-based study (OR = 1.36, 95% CI: 1.19–1.56, OR = 1.18, 95% CI: 1.03–1.34 and OR = 1.26, 95% CI: 1.12–1.43, respectively) in stratified analysis. We observed an increased colorectal risk among CC and CC + CT carriers in European and American population (OR = 1.22, 95% CI: 1.04–1.43 and OR = 1.18, 95% CI: 1.02–1.38, respectively). We also observed an increased risk of colon cancer among subjects carrying CC + CT genotype (OR = 1.31, 95% CI: 1.05–1.63).ConclusionsThe present meta-analysis results suggest that TGF-β1 gene promoter -509C allele variant is a possible risk factor for developing colorectal cancer. Recommendations for further studies include pooling of individual data to verify results from the study and to facilitate evaluation of multigenic effects and detailed analysis of effect modification by environmental and lifestyle factors.  相似文献   

13.
The aim of the present study was to investigate the contribution of the single photon emission computed tomography/computed tomography (SPECT/CT) in cancer patients and to evaluate its ability to correctly classify indeterminate lesions on planar bone scintigraphy (PBS).MethodsFrom November 2006 to August 2007, all patients with confirmed malignancy, whose PBS showed indeterminate lesions, underwent without delay a SPECT/CT. The study included 120 patients (67 men, 53 women), with a mean age of 69 ± 12 years (range 42–96 years). The patients with obvious metastases, important pains or who did not accept the examination were excluded from the study. The location of the lesions was described either as precise, probable or indeterminate. The lesions were classified either as definitely malignant, definitely benign or indeterminate.ResultsBreast, prostate, lung and kidney neoplasms represented approximately 80% of all cancers. The PBS highlighted 267 lesions of location either as precise (n = 29), probable (n = 129) or indeterminate (n = 109), classified either as definitely malignant (n = 28), definitely benign (n = 27) or indeterminate (n = 212). The SPECT/CT revealed 440 lesions, of location either as precise (n = 353), likely (n = 39) or indeterminate (n = 48), classified either as definitely malignant (n = 84), definitely benign (n = 305) or indeterminate (n = 51). Thoracic and lumbar spine and pelvis were the locations of 79% of the scintigraphic lesions and of 88% of the osseous metastases. SPECT/CT modified the final report of 80 patients, by excluding from metastases (n = 2), by showing metastases (n = 23) and by showing the benign character of indeterminate lesions (n = 55). Moreover, 69 patients out of 120 (> 57%) had an evolution confirmed with 35 true positives, 31 true negatives, one false negative and two patients with indeterminate lesions on SPECT/CT, without osseous metastasis.ConclusionThe assessment of the indeterminate scintigraphic lesions of oncologic patients benefits from the SPECT/CT. The lesion-based analysis showed that the SPECT/CT detected more lesions (+64%) and correctly classified 88% of the detected lesions. The patient-based analysis highlighted that SPECT/CT modified the final report for more than 66% of the patients. The follow-up showed that SPECT/CT correctly classified for more than 95% of the patients.  相似文献   

14.
AimTo evaluate whether the sequential dual-time-point fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (DTP 18F-FDG PET/CT) study improves the differential diagnosis in the larynx.BackgroundIn some cases, the clinical and metabolic similarity of laryngitis and larynx cancer make differential diagnostics difficult when performing standard 18F-FDG PET/CT examinations; therefore, an additional study protocol performance seems to be of reasonable value.Materials and methods90 patients (mean age: 61 ± 11 years, range: 41–84 years): 23 women (mean age: 63 ± 10 years, range: 51–84 years) and 67 men (mean age: 61 ± 11 years, range: 41–80 years) underwent delayed 18F-FDG PET/CT examinations at 60 and 90 min post intravenous injection (p.i.) of the radiopharmaceutical 18F-FDG. We compared the metabolic activity of 90 structures divided into following groups: normal larynx (30 patients), laryngitis (30 lesions) and larynx cancer (30 tumors) with maximal and mean standardized uptake value (SUVmax, SUVmean) and the retention index (RI-SUVmax). We used the receiver operating characteristics (ROC) curve to evaluate the SUVmax cut-off values.ResultsThe SUVmax cut-off value at 60 and 90 min p.i. of 2.3 (sensitivity/specificity: 96.4%/100%) and 2.4 (94.2%/100%), respectively, distinguished normal and abnormal metabolic activity in the larynx. When laryngitis and tumors were compared, the SUVmax cut-off values obtained after initial and delayed imaging were 3.6 (87.5%/52.0%) and 6.1 (58.3%/84%), respectively. The RI-SUVmax of 1.3% (71.4%/88.1%) suggested abnormality, while RI-SUVmax of 6.6%, malignant etiology (75.0%/80.0%).ConclusionsIn this study, the sequential DTP scanning protocol improved the sensitivity and specificity of the PET/CT method in terms of differential diagnosis within the larynx.  相似文献   

15.
PurposePancreatic tumor treatment dose distribution variations associated with supine and prone patient positioning were evaluated.MethodsA total of 33 patients with pancreatic tumors who underwent CT in the supine and prone positions were analyzed retrospectively. Gross tumor volume (GTV), planning target volume (PTV), and organs at risk (OARs) (duodenum and stomach) were contoured. The prescribed dose of 55.2 Gy (RBE) was planned from four beam angles (0°, 90°, 180°, and 270°). Patient collimator and compensating boli were designed for each field. Dose distributions were calculated for each field in the supine and prone positions. To improve dose distribution, patient positioning was selected from supine or prone for each beam field.ResultsCompared with conventional beam angle and patient positioning, D2cc of 1st-2nd portion of duodenum (D1-D2), 3rd-4th portion of duodenum (D3-D4), and stomach could be reduced to a maximum of 6.4 Gy (RBE), 3.5 Gy (RBE), and 4.5 Gy (RBE) by selection of patient positioning. V10 of D1-D2, D3-D4, and stomach could be reduced to a maximum of 7.2 cc, 11.3 cc, and 11.5 cc, respectively. D95 of GTV and PTV were improved to a maximum of 6.9% and 3.7% of the prescribed dose, respectively.ConclusionsOptimization of patient positioning for each beam angle in treatment planning has the potential to reduce OARs dose maintaining tumor dose in pancreatic treatment.  相似文献   

16.
PurposeThis study aimed to determine whether the SiPM-PET/CT, Discovery MI (DMI) performs better than the PMT-PET/CT system, Discovery 710 (D710).MethodsThe physical performance of both systems was evaluated using NEMA NU 2 standards. Contrast (%), uniformity and image noise (%) are criteria proposed by the Japanese Society of Nuclear Medicine (JSNM) for phantom tests and were determined in images acquired from Hoffman and uniform phantoms using the DMI and D710. Brain and whole-body [18F]FDG images were also acquired from a healthy male using the DMI and D710.ResultsThe spatial resolution at 1.0 cm off-center in the DMI and D710 was 3.91 and 4.52 mm, respectively. The sensitivity of the DMI and D710 was 12.62 and 7.50 cps/kBq, respectively. The observed peak noise-equivalent count rates were 185.6 kcps at 22.5 kBq/mL and 137.0 kcps at 29.0 kBq/mL, and the scatter fractions were 42.1% and 37.9% in the DMI and D710, respectively. The D710 had better contrast recovery and lower background variability. Contrast, uniformity and image noise in the DMI were 61.0%, 0.0225, and 7.85%, respectively. These outcomes were better than those derived from the D710 and satisfied the JSNM criteria. Brain images acquired by the DMI had better grey-to-white matter contrast and lower image noise at the edge of axial field of view.ConclusionsThe DMI offers better sensitivity, performance under conditions of high count rates and image quality than the conventional PMT-PET/CT system, D710.  相似文献   

17.
IntroductionThe aim of this work was to assess the role of 3T-MR spectroscopy (MRS) in the multi-parametric MRI evaluation of breast lesions, using a pattern-recognition based classification method.Methods291 patients (301 lesions, median 2.3 cm3) were enrolled in the study (age 18–85 y, mean 54.2 y). T1-TSE (TR/TE = 400/10 ms) and T2-STIR imaging (TR/TE = 5000/60 ms), dynamic-contrast-enhanced MRI (DCE-MRI), apparent diffusion coefficient (ADC) (b = 0–800 s/mm2), and single-voxel MRS (10 × 10 × 10 mm3, PRESS, TR/TE = 3000 ms/135 ms) were performed by means of a 3T scanner. MRS results were accepted if the FWHM of the water peak was ⩽45 Hz. Total choline (tCho) was considered detected if the signal-to-noise ratio (SNR) of the 3.2 ppm peak was ⩾2. A classifier-based analysis (support-vector-machines, SVM) was performed with 4-dimensional vectors including type of margin, DCE-MRI kinetic curve type, ADC mean value, and tCho SNR. A comparison with 3-dimensional vectors (without tCho SNR) was used to assess MRS impact on sensitivity, specificity, and positive-negative predictive values (PPV-NPV) for malignancy.Results228 lesions (180 malignant/48 benign) showed acceptable spectral quality. Comparison of classification results with histopathological examination of surgical specimens showed sensitivity = 93.7%, specificity = 84.9%, PPV = 95.2%, NPV = 81.5% without the inclusion of MRS in the SVM analysis. When MRS was included, the figures increased to 95.1%, 90.7%, 97.2%, and 85.0%, respectively.ConclusionsInclusion of 3T-MRS in the multi-parametric MRI evaluation of breast lesions improved the performance of the SVM-based classifier, showing a possible role of high-field MR spectroscopy in the differential diagnosis between benign and malignant breast lesions. Further research is however needed to confirm this initial evidence.  相似文献   

18.
PurposeThe objective of this study was to retrospectively evaluate the impact of positron emission tomography/computed tomography (PET/CT) using fluorine-18-fluorodeoxyglucose (FDG), in comparison with conventional imaging modalities (CIM), for initial staging and early therapy assessment in paediatric rhabdomyosarcoma.Patients and methodsPrior to treatment, 18 patients (age range, 9 months to 18 years) with histologically proven rhabdomyosarcoma underwent FDG PET/CT in addition to CIM (magnetic resonance imaging of primary site, whole body CT and bone scintigraphy). After three courses of chemotherapy, 12 patients underwent FDG PET/CT in addition to CIM. RECIST criteria and visual analysis of FDG uptake were used for assessment of response. The standard of reference was determined by an interdisciplinary tumor board based on imaging material, histopathology and follow-up data (median = 5 years).ResultsPET/CT sensitivity was superior to CIM's concerning lymph node involvement (100% versus 83%, respectively) and metastases detection (100% versus 50%, respectively). PET/CT results changed therapeutic management in 11% of cases. After three courses of chemotherapy, the rate of complete response was 66% with PET/CT versus 8% with CIM. Five percent of patients relapsed during follow-up (median = 5 years).ConclusionThis study confirms that PET/CT depicts important additional information in initial staging of paediatric rhabdomyosarcomas and suggests a superior prognostic value of PET/CT in early response to chemotherapy assessment.  相似文献   

19.
Aim18F-FDG PET/CT by combining both metabolic and anatomical informations has proven to be an effective modality for detecting many types of cancer. Some differentiated forms of cancer like differentiated thyroid carcinoma (DTC) are less FDG avid and thus less easily detectable. Nevertheless 18F-FDG PET/CT has been proved useful in DTC especially in case of suspected recurrent disease with negative whole-body radioiodine scintigraphy (131I WBS) and elevated thyroglobulin (Tg) or thyroglobulin autoantibodies (AbTg) levels. Impact on clinical management after 18F-FDG PET/CT examinations has been analyzed in patients with suspected recurrent DTC in this retrospective study.MethodologyFifty-five 18F-FDG PET/CT were performed in 45 patients with suspected recurrent or residual disease either because of elevated Tg/AbTg levels (n = 45) or uncertain conventional imaging (n = 10) including 131I WBS, cervical echography and CT scan if necessary. 18F-FDG PET/CT results were compared with histopatology and/or clinical follow-up with evaluation of impact on clinical management.ResultsTwenty-nine exams were positive (53 %). There were 20 true-positive (TP) (14 locoregional relapses and six with distant metastases) and nine false-positive (FP) (all cervical). SUVmax median values of hypermetabolic foci were significantly higher in TP (5.1) than in FP (2.8). Overall, 20 (36 %) 18F-FDG PET/CT directly affected clinical management resulting in 13 (65 %) new surgical operations. Sensitivity, specificity, predictive positive value, predictive negative value and accuracy of 18F-FDG PET/CT were estimated for the whole group (respectively 83 %, 71 %, 69 %, 85 % and 76 %) and for two subgroups depending on Tg level (less or more than 1.2 ng/mL).Discussion and conclusion18F-FDG PET/CT is a powerful and useful tool in patients with suspected DTC recurrence or residual disease and should be systematically performed when basal Tg level is above 1.2 ng/mL. Thanks to given anatomical informations it can guide surgical re-operation.  相似文献   

20.
PurposeTransluminal-attenuation-gradient (TAG) may reflect patient characteristics and physiological parameters. Furthermore, TAG may be affected by factors such as the CT scanner speed, scanning method, scan timing after contrast-medium (CM) injection, and the injection methods. The purpose of our study was to investigate quantitative TAG at different scan timing points after CM injection for coronary CT angiography.Materials and methodsUsing a CM flow phantom and two types of connecting tube mimicking 0% and 70% coronary artery stenosis, we performed 320-detector volume scanning. The heart rate was set at 60 bpm and cardiac-output (CO) at 2.0 and 4.0 l/min, respectively. The acquisition time repeated at 0.5-s intervals for 40 and 25 s at a CO of 2.0- and 4.0 l/min. We measured the CT number on the same slice level, calculated the time-density-curve (TDC) and the TAG at each time point.ResultsAt COs of 2.0 and 4.0 l/min at 0% stenosis, TAG exhibited smaller variations (−3.02 to +0.55 HU/cm at 2.0 l/min, −2.63 to +0.43 HU/cm at 4.0 l/min) than at 70% stenosis at each time point along the TDC. Compared with a CO at 2.0 l/min with 70% stenosis, the TAG curve for a CO at 4.0 l/min gradually changed with time (−6.64 to +1.18 HU/cm at 2.0 l/min vs. −3.46 to +2.75 HU/cm at 4.0 l/min).ConclusionThe TAG value was affected by scan timing after CM injection and by CO although the size of the connecting tube with and without stenosis was identical.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号