首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Luner PE  Patel AD 《AAPS PharmSciTech》2005,6(2):E245-E252
The objective of this study was to use diffuse reflectance near infrared spectroscopy (NIRS) to determine racemic compound content in physical mixtures composed primarily of the enantiomorph and to assess the error, instrument reproducibility and limits of detection (LOD) and quantification (LOQ) of the method. Physical mixtures ranging from 0 to 25% (±)-tartaric acid in (+)-tartaric acid were prepared and spectra of the powder samples contained in glass vials were obtained using a Foss NIRSystems Model 5000 monochrometer equipped with a Rapid Content Analyzer scanning from 1100 to 2500 nm. A calibration curve was constructed by plotting (±)-tartaric acid weight percent against the 2nd derivative values of log (1/R) vs λ at a single wavelength, normalized with a denominator wavelength (1480 nm/1280 nm). Excellent linearity was observed (R2=0.9999). The standard error of calibration (SEC) was 0.07 and the standard error of prediction (SEP) for the validation set was 0.11. Instrument and method errors for samples in the 2% composition range ((±)-tartaric acid in (+)-tartaric acid) were less than 1% RSD and 3% RSD, respectively. The practical LOD and LOQ were 0.1% and 0.5%, respectively, and comparable to the calculated LOD and LOQ. These studies show that NIRS can be used as a rapid and sensitive quantitative method for determining racemate content in the presence of the enatiomerically pure crystal in the solid-state. Published: October 6, 2005  相似文献   

2.
To study the distribution of fluconazole in the dermis of the rat, on-line microdialysis using double-site sampling coupled with a microbore HPLC system was developed. The chromatographic conditions consisted of a mobile phase of 20 mM diammonium phosphate-acetonitrile (75:25, v/v, pH 7.0) pumped through a microbore C(18) column at 40 microl/min. The eluent was monitored with UV detector with UZ flow cell (30 mm path length) at 210 nm. A microbore 10-port pneumatic valve fitted with two loops of 1 microl was used to collect and directly inject microdialysates from jugular and dermal probes. The retention time was 5.8 min for fluconazole and 10.1 min for its fluorinated analog, UK-54373 used as a retrodialysis marker. The assay was precise, with inter- and intra-assay relative standard deviation values of 0.64 and 0.71%, respectively, and with a good linearity (r=0.999) in the range of 0.15-20 microg/ml with only 1 microl injected onto the column. The LOD and LOQ values for fluconazole were 0.100 and 0.150 microg/ml, respectively. The applicability of the method was demonstrated by studying the disposition of fluconazole in blood and dermis following i.v. bolus at a dose of 10 mg/kg.  相似文献   

3.
This report describes a rapid, simple and sensitive isocratic high-performance liquid chromatography with diode array UV detection for micro-sample analysis of paclitaxel in mouse plasma. The analysis utilized a Capcell-pak octadecyl analytical column and a mobile phase consisting of acetonitrile–0.1% phosphoric acid in deionized water (55:45, v/v). Paclitaxel and n-hexyl p-hydroxybenzoic acid (internal standard) were extracted from plasma by one-step extraction with tert.-butyl methyl ether. Peak purity was determined over a UV wavelength range of 200 to 400 nm. Paclitaxel and the internal standard were eluted at 3.4 min and 5.4 min, respectively, at a mobile phase flow-rate of 1.3 ml/min. No interfering peaks were observed and the total run time was 10 min. The standard curve was linear (r=0.9999) over the concentration range of 0.010–500 μg/ml. The extraction recovery was >90% for both paclitaxel and n-hexyl p-hydroxybenzoic acid. The intra- and inter-day assay variabilities of paclitaxel ranged from 0.4 to 2.2% and 0.6 to 7.8%, respectively. The LOD and LOQ were 5 and 10 ng/ml, respectively, for paclitaxel using a plasma sample volume of 100 μl. This highly sensitive and simple assay method was successfully applied to a pharmacokinetic study after i.v. administration of paclitaxel 20 mg/kg to mice.  相似文献   

4.
The present study deals with the development of a method for the quantitative determination of lipoic acid in a dietary supplement preparation. A rapid capillary electrophoretic method is developed using UV detection at 208 nm. Although lipoic acid is only weakly UV-absorbing, at this wavelength it could be detected with sufficient sensitivity with an LOD and LOQ of 0.8 and 2.5 microg/ml, respectively. Analysis time was less than 9 min. The compound was extracted from tablets with a recovery of 98.3% and a precision of 2.8% RSD.  相似文献   

5.
An electrospray ionization (ESI) compatible separation of phospholipids (PL), phosphatidylglycerol (PG), phosphatidylethanolamine (PE), and phosphatidylcholine (PC), was performed on a C18 column by reversed phase High Performance Liquid Chromatography (HPLC) with minimal ESI suppression. The mobile phase, used isocratically, consisted of methanol and water. ESI was used to efficiently transfer the ions present in solution to the gas phase for mass spectrometric (MS) detection. Formation of negative ions was reinforced by incorporating piperidine post column. Limits of detection (LOD) and limits of quantitation (LOQ) were experimentally determined to be 20 and 60 fmol/microl, respectively, when acquiring data in the selected ion monitoring (SIM) mode monitoring three ions with a single quadrupole MS. When acquiring data from m/z 110-900 in the scanning mode, the LOD and LOQ were experimentally determined to be 1 pmol/microl and 3 pmol/microl. When acquiring product ion spectra for m/z 747, the LOD and LOQ were experimentally determined to be 446 attomol/microl and 1.3 fmol/microl, respectively.  相似文献   

6.
Moxifloxacin and ofloxacin are two broad-spectrum quinolone antibiotics. They are among the most widely used antibiotics, at this time, applied to control the COVID-19 pandemic. Hydroxychloroquine is an FDA-approved drug for the treatment of COVID-19. This work describes a simple, green, selective, and sensitive spectrofluorimetric method for the assay of moxifloxacin and ofloxacin in the presence of hydroxychloroquine, two co-administered mixtures used in the treatment of hospital-acquired pneumonia in patients with COVID-19. Simultaneous assay of hydroxychloroquine and moxifloxacin was carried out in methanol using a direct spectrofluorimetric method (method I) at 375 and 550 nm, respectively, after excitation at 300 nm. The direct spectrofluorimetric assay was rectilinear over concentration ranges 50.0–400.0 and 300.0–2500.0 ng/ml for hydroxychloroquine and moxifloxacin, respectively, with limits of detection (LOD) of 6.4 and 33.64 ng/ml and limits of quantitation (LOQ) of 19.4 and 102.6 ng/ml, respectively, for the two drugs. The assay for hydroxychloroquine and ofloxacin was carried out by measuring the first derivative synchronous amplitude for hydroxychloroquine at the zero crossing point of ofloxacin and vice versa at Δλ = 140 nm (method II). Hydroxychloroquine was measured at 266 nm, while ofloxacin was measured at 340 nm over the concentration range 4–40 ng/ml for hydroxychloroquine and 200–2000 ng/ml for ofloxacin with LOD of 0.467 and 25.3 ng/ml and LOQ of 1.42 and 76.6 ng/ml, respectively, for the two drugs. The two methods were validated following International Conference on Harmonization guidelines and were applied to the analysis of the two drugs in plasma with good percentage recoveries (109.73–93.17%).  相似文献   

7.
One hundred and eighty five samples of red, white and rosé wines and different juices purchased in Entre Rios, Argentina, were analyzed for the Alternaria mycotoxins alternariol (AOH) and alternariol methyl ether (AME). White wines were analyzed after removal of alcohol by a nitrogen stream and concentrated. AOH in red wines was cleaned up by solid-phase extraction columns in series (octadecyl and amino propyl modified silica) and AME quantified directly on the sample. The juices were filtered and concentrated, and then all sample extracts were quantified by high performance liquid chromatography with photodiode array detector that allows confirmation through UV spectra. Method validation revealed a good sensitivity with adequate LOD and LOQ for AME and less sensitivity for AOH (i.e. white wine: AME 0.8 and 1.4 ng/mL, AOH 2 and 3.3 ng/mL; red wine: AME 0.1 and 0.2 ng/mL, AOH 4.5 and 7.5 ng/mL; apple juice: AME 1.7 and 2.8 ng/mL, AOH 5 and 9 ng/mL; other juices: AME 2.0 and 3.1 ng/mL, AOH 6 and 10 ng/mL). Recoveries in all cases were greater than 80 %. Four of 53 white wine samples were contaminated with AOH with a maximum level of 18 ng/mL, 6 of 56 samples of red wine had a maximum of 13 ng/mL, and 3 of 68 samples of juices had traces of AOH. AME was less frequently detected than AOH, and the LOD and LOQ for AME are smaller than for AOH. Only three samples of white wine and one of red wine were contaminated, but in only one white wine sample (AME 225 ng/mL) did the toxin level exceed the LOQ.  相似文献   

8.
The paper describes the determination of deoxynivalenol (DON) in 55 wheat food and feed samples, 26 from conventional and 29 from organic production. Immunoaffinity columns prepared by entrapping anti-DON antibodies by the sol–gel method were used for sample clean-up. DON was quantified by high performance liquid chromatography (HPLC) and ultraviolet (UV) detection. In general, the incidence of DON contamination was rather low. In eight samples (14.5%) the DON concentration was above the LOQ (380 ng/g), in six samples (10.9%) DON was detected but could not be quantified (>LOD (200 ng/g), <LOQ). In seven conventional samples (two pasta, two cookie, two snack and one feed sample) but only in one organic sample (a snack) the DON concentration was >LOQ. The data indicate both a higher incidence of DON contamination and higher DON concentrations in food and feed samples from conventional than in those from organic production.  相似文献   

9.
A high-performance liquid chromatographic and an UV spectrophotometric method were developed and validated for the quantitative determination of three antiretroviral drugs viz. Lamivudine, Stavudine and Nevirapine that constitute one of the first line regimens in antiretroviral therapy. The different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD) and limit of quantification (LOQ) were determined according to International Conference on Harmonization ICH Q2B guidelines. Chromatography was carried out by isocratic technique on a reversed-phase C-18 SYMMETRY column with mobile phase based and optimized depending on the polarity of the molecules. The UV spectrophotometric determinations were performed at 270, 265 and 313 nm for Lamivudine, Stavudine and Nevirapine, respectively. The linearity of the calibration curves for each analyte in the desired concentration range is good (r(2)>0.999) by both the HPLC and UV methods. Both the methods were accurate and precise with recoveries in the range of 97 and 103% for all the three drugs and relative standard deviation (R.S.D.) <5%. Moreover, the accuracy and precision obtained with HPLC correlated well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence were successfully applied for the reliable quantification of API content in the commercial formulations of Lamivudine, Stavudine and Nevirapine.  相似文献   

10.
Melatonin is a hormone mainly involved in the regulation of circadian and seasonal rhythms in both invertebrates and vertebrates. Despite the identification of melatonin in many insects, its involvement in the insect seasonal response remains unclear. A liquid chromatography tandem mass spectrometry (LC–MS/MS) method has been developed for melatonin analysis in aphids (Acyrthosiphon pisum) for the first time. After comparing two different procedures and five extraction solvents, a sample preparation procedure with a mixture of methanol/water (50:50) was selected for melatonin extraction. The method was validated by analyzing melatonin recovery at three spiked concentrations (5, 50 and 100 pg/mg) and showed satisfactory recoveries (75–110%), and good repeatability, expressed as relative standard deviation (<10%). Limits of detection (LOD) and quantitation (LOQ) were 1 pg/mg and 5 pg/mg, respectively. Eight concentration levels were used for constructing the calibration curves which showed good linearity between LOQ and 200 times LOQ. The validated method was successfully applied to 26 aphid samples demonstrating its usefulness for melatonin determination in insects. This is -to our knowledge- the first identification of melatonin in aphids by LC–MS/MS.  相似文献   

11.
The iodine-azide detection system to determine methimazole following its separation by RP-HPLC is described in this paper. The reaction between iodine and azide ions induced by methimazole was applied as a post-column reaction detection system. Neither extraction nor preconcentration of the sample was necessary. The methimazole standards added to normal urine show that the response of the detector, set at 350 nm (corresponding to unreacted iodine in the post-column iodine-azide reaction), was linear within the concentration range 2-10 nmol/mL of urine. The relative standard deviation values for precision and recovery within the calibration range were from 0.3 to 3.2% and from 97 to 102%, respectively. Limits of detection (LOD) and quantitation (LOQ) were 1 and 2 nmol/mL of urine, respectively. The method was applied to the separation and determination of patient urine samples and the analytical results were satisfactory.  相似文献   

12.
A rapid, simple and robust method is presented for the simultaneous determination of the gamma-amino-n-butyric acid (GABA) derivatives pregabalin (PGB), gabapentin (GBP) and vigabatrin (VGB) in human serum by high-performance liquid chromatography (HPLC). Serum is deproteinized with trichloroacetic acid and aliquots of the supernatant are precolumn derivatized with o-phtaldialdehyde (OPA) and 3-mercaptopropionic acid. Separation is achieved on a Alltima 3C18 column using isocratic elution; the drugs are monitored using fluorescence detection. Norvaline is used as an internal standard. Within-day precision (COV; n = 10) is 1.2% for PGB (serum concentration 10.0 mg/l), 1.1% for GBP (serum concentration 15.8 mg/l) and 0.3% for VGB (serum concentration 15.5 mg/l). The method is linear up to at least 63 mg/l for PGB, 40 mg/l for GBP and 62 mg/l for VGB. Lower limits of quantitation (LOQ) are 0.13 mg/l for PGB, 0.53 mg/l for GBP and 0.06 mg/l for VGB. No interferences were found from commonly coadministered antiepileptic drugs (AEDs) and from endogenous amino acids. Experimental design in combination with statistical evaluation (ANOVA) was used to study the robustness of chromatography and sample preparation. The method is very suitable for routine therapeutic drug monitoring and for pharmacokinetic studies.  相似文献   

13.
We developed a new and fast multidimensional on-line HPLC-method for the quantitative determination of the secondary, chain oxidized monoester metabolites of diethylhexylphthalate (DEHP), 5-hydroxy-mono-(2-ethylhexyl)-phthalate (5OH-MEHP) and 5-oxo-mono-(2-ethylhexyl)-phthalate (5oxo-MEHP) in urine samples from the general population. Also included in the method were the simple monoester metabolites of DEHP, dioctylphthalate (DOP), dibutylphthalate (DBP), butylbenzylphthalate (BBzP) and diethylphthalate (DEP). Except for enzymatic hydrolysis for deconjugation of the metabolites no further sample pre-treatment step is necessary. The phthalate metabolites are stripped from urinary matrix by on-line extraction on a restricted access material (LiChrospher((R)) ADS-8) precolumn, transferred in backflush-mode and chromatographically resolved by reversed-phase HPLC. Eluting metabolites are detected by ESI-tandem mass spectrometry in negative ionization mode and quantified by isotope dilution. Within a total run time of 25 min we can selectively and sensitively quantify seven urinary metabolites of six commonly occurring phthalate diesters including the controversial di(2-ethylhexyl)phthalate (DEHP). The detection limits for all analytes are in the low ppb range (0.5-2.0 microgram/l urine). First results on a small non-exposed group (n=8) ranged for 5OH-MEHP from 0.59 to 124 microgram/l, for 5oxo-MEHP from 相似文献   

14.
A simple and valid ultraviolet (UV) spectrophotometric method for the determination of poly(γ-glutamic acid) is developed. The method is based on the UV absorption spectrum of γ-PGA in aqueous solution, which exhibits a maximum absorption wavelength at 216 nm. The results obtained were comparable to those obtained with the reported high-performance liquid chromatography (HPLC) method according to ICH guidelines. Under the proposed procedure, the calibration graph is linear over the range of 20-200 μg/ml with regression correlation coefficient of 0.9997. Precision (%R.S.D.<1.50) and recovery (%R.>99.29%) are good. The limit of detection (LOD) and limit of quantitation (LOQ) are 0.39 and 1.19 μg/ml, respectively. These results agree well with those of HPLC method. Its spectrum properties studies showed that the spectrum of γ-PGA remarkably changed with an increase in temperature due to γ-PGA was digested into glutamate monomer. In spite of this, the determining procedure could carried out in a wide temperature range (25-50°C). In addition, the method is not influenced by the molecular weight, but the measurement system need to control in pH 3.0-10.0 and ionic strength not more than 0.5M. The proposed method is applied successfully for high-throughput quantification of poly(γ-glutamic acid) in biological samples. The advantages of the UV method are simplicity of operation, rapidity, sensitive, low-cost and high-throughput.  相似文献   

15.
The determination of benzene in exhaled air has contributed for the increase in the use of breath analysis in biological monitoring. This paper describes SPME as a sampling technique for determining benzene in exhaled air by GC-MS. A system was developed to generate a gaseous benzene standard by a permeation method to accomplish the breath analyses. The method presented good resolution, repeatability (the mean of %RSD values for intra-day measurements was 6.3), sensitivity (2.4 and 3.1 ppb for LOD and LOQ, respectively), and linearity of response (R(2)=0.994). After optimizing the conditions, analyses of real samples were performed on two groups (exposed and not exposed to benzene). The results presented an average of 8.2 ppb for the control group and 25.3 ppb for the exposed group.  相似文献   

16.
Supported liquid membrane (SLM) technique for sample work-up and enrichment was used for determination of tricyclic antidepressant drugs in urine by high-performance liquid chromatography (HPLC) with UV detection. The studied antidepressant drugs were amitriptyline, opipramol, noxiptyline and additionally diethazine was used as possible internal standard. Alkaline phosphoric buffer with urine sample, as the donor solution, was passed over the liquid membrane into which investigated substances were extracted. On the other side of the membrane, analyzed compounds were trapped due to creating non-extractable form in acidic acceptor solution. Enriched and cleaned up drugs were then injected into a HPLC system with ultraviolet detection to analyze of their concentration in acceptor solution. Optimum extraction efficiency was determined by changing acceptor and donor solutions pH, application of different flow rates of donor solution and by using different solvents in the membrane. Also, donor solution volume, extraction time and concentration of analytes were varied to check the linearity of extraction process. The highest extraction efficiency: 43% for opipramol, 56% for noxiptyline, 43% for amitriptyline and 42% for diethazine (R.S.D. values were <6% and n=3) was achieved when 0.05 M phosphate buffer pH 4.0 and 9.5 were used as donor and acceptor solutions, respectively, n-undecane with 5% tri-n-octylphosphine oxide (TOPO) was used as liquid membrane. Limit of quantification (LOQ) for tricyclic antidepressants after enrichment of 100ml of urine sample was about 1 ng/ml.  相似文献   

17.
A high-performance liquid chromatographic (HPLC) assay for the determination of nicotine and cotinine in human milk was developed using an extraction by liquid-liquid partition combined with back extraction into acid, and followed by reverse-phase chromatography with UV detection of analytes. The assay was linear up to 500 microg/l for both nicotine and cotinine. Intra- and inter-day relative standard deviations (R.S.D.) were <10% (25-500 microg/l) for both nicotine and cotinine. Limits of quantitation (LOQ) were 10 and 12 microg/l for nicotine and cotinine, respectively, while the limits of detection (LOD) were 8 and 10 microg/l for nicotine and cotinine, respectively. The mean recoveries were 79-93% (range 25-500 microg/l) for nicotine and 78-89% (range 25-500 microg/l) for cotinine. The amount of fat in the milk did not affect the recovery. We found that this method was sensitive and reliable in measuring nicotine and cotinine concentrations in milk from a nursing mother who participated in a trial of the nicotine patch for smoking cessation.  相似文献   

18.
Benzodiazepines and zolpidem are controlled in many countries due to their inherent adverse effects of a high degree of tolerance and dependence. Recently, as some of these drugs have become distributed illegally and available through media such as the Internet, their abuse is becoming a serious social problem. Hair is a useful specimen to prove chronic drug use. In the present study, a simultaneous analytical method for the detection of 27 benzodiazepines and metabolites and zolpidem in hair was established and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The drugs and their metabolites in hair were extracted using methanol, filtered and injected on the LC-MS/MS. The following validation parameters of the method were satisfactory: selectivity, linearity, matrix effect, recovery, process efficiency, intra- and inter-assay precision and accuracy and processed sample stability. The limit of detection (LOD) and the limit of quantification (LOQ) were the total drug detected from the sample. The LODs ranged from 0.005 ng (zolpidem) to 0.5 ng (bromazepam and chlordiazepoxide) and the LOQs were 0.25 ng in every analyte except for bromazepam and chlordiazepoxide, for which they were 0.5 ng. The developed method was successfully applied to five legal cases involving use of benzodiazepines and zolpidem and to an animal study on drug incorporation into hair. Diazepam and its three metabolites, as well as lorazepam, were detected in hair from both the multiple- and single-dose administration groups of lean Zucker rats. The concentration of diazepam was higher than those of its metabolites in both dark grey and white hair from the multiple-dose administration groups, with the mean concentration ranges from 0.16 to 0.51 ng/mg and from 0.10 to 0.24 ng/mg, respectively. The mean concentration ranges of lorazepam were from 0.05 to 0.37 ng/mg in dark grey hair and from 0.11 to 0.45 ng/mg in white hair from the multiple-dose administration groups. Hair pigmentation did not have any significant effect on the degree of the deposition of drugs and their metabolites in hair.  相似文献   

19.
Yeastolates, triton X-100 (TX-100) and methotrexate (MTX) are common process-related impurities (PRI) in cell-based bioproduction of many active biopharmaceuticals. In this study, a reverse phase high performance liquid chromatography (RP-HPLC) method coupled with ultraviolet (UV) detection was developed for simultaneous determination and quantitation of these impurities. The chromatographic separation was achieved using a Jupiter C4 column and analyses of yeastolates, TX-100 and MTX were monitored at 257, 280 and 302 nm, respectively. The method was further validated with respect to selectivity, linearity, limit of detection (LOD), limit of quantitation (LOQ), precision and accuracy. The limits of quantitation for yeastolates, TX-100 and MTX were determined to be 27 ppm, 10 ppm and 41 ppb, respectively. Finally, the suitability of the method for analyses of recombinant human hyaluronidase (rHuPH20) in-process (viral inactivation, QFF, PS, APB and CHT filtered, final viral filtrate) and final manufacturing materials was demonstrated, and trace levels of yeastolates, TX-100 and MTX were reliably measured except for three matrices early in the purification process in which TX-100 was not accurately determined due to interfering effects.  相似文献   

20.
A simple, rapid and reliable method was developed for the identification and quantification of helicidum and its metabolites in beagle dog plasma by liquid chromatography/ultra-violet/electrospray ionization-ion trap mass spectrometry (LC/UV/ESI-ITMS). Two metabolites were identified by MS: formylphenyl-O-beta-d-pyranosyl alloside (I) and hydroxylmethylphenyl-O-beta-d-pyranosyl alloside (II). UV was used for concentration determination with the wavelength of 270 nm. Liquid-liquid extraction was used and the extraction recovery exceeded 90%. Kromacil C(18) column (5 microm, 4.6mm i.d. x 250 mm) was used as the analytical column. Linear detection responses were obtained for helicidum concentration ranging from 1.76 x 10(-4) to 70.4 x 10(-4) micromol/mL (0.050-2.00 microg/mL). The precision and accuracy data, based on intra- and inter-day variations over 3 days, were less than 5%. The limit of determination and quantitation (LOD, LOQ) for helicidum was 0.010 and 0.030 microg/mL, respectively. Pharmacokinetic data of helicidum and the two metabolites were obtained with this method after administration of intravenous injection and a single oral dose of tablets to six beagle dogs, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号