首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Luk VN  Fiddes LK  Luk VM  Kumacheva E  Wheeler AR 《Proteomics》2012,12(9):1310-1318
Proteolytic digestion is an essential step in proteomic sample processing. While this step has traditionally been implemented in homogeneous (solution) format, there is a growing trend to use heterogeneous systems in which the enzyme is immobilized on hydrogels or other solid supports. Here, we introduce the use of immobilized enzymes in hydrogels for proteomic sample processing in digital microfluidic (DMF) systems. In this technique, preformed cylindrical agarose discs bearing immobilized trypsin or pepsin were integrated into DMF devices. A fluorogenic assay was used to optimize the covalent modification procedure for enzymatic digestion efficiency, with maximum efficiency observed at 31 μg trypsin in 2-mm diameter agarose gel discs. Gel discs prepared in this manner were used in an integrated method in which proteomic samples were sequentially reduced, alkylated, and digested, with all sample and reagent handling controlled by DMF droplet operation. Mass spectrometry analysis of the products revealed that digestion using the trypsin gel discs resulted in higher sequence coverage in model analytes relative to conventional homogenous processing. Proof-of-principle was demonstrated for a parallel digestion system in which a single sample was simultaneously digested on multiple gel discs bearing different enzymes. We propose that these methods represent a useful new tool for the growing trend toward miniaturization and automation in proteomic sample processing.  相似文献   

2.
Over the past few years, technological advances in automated DNA sequencing have had a profound effect on the nature of DNA sequencing laboratories. To characterize the changes occurring within DNA sequencing facilities, the DNA Sequencing Research Group conducted three previous studies, in 1998, 2000, and 2003. A new general survey has been designed and conducted by the DSRG to capture the current status of DNA sequencing facilities in all sectors. Included were questions regarding facility administration, pricing, instrumentation, technology, protocols, and operation. The results of the survey are presented here, accompanied by comparisons to the previous surveys. These comparisons formed a basis for the discussion of trends within the facilities in response to the dynamics of a changing technology.  相似文献   

3.
The field of sequencing is a topic of significant interest since its emergence and has become increasingly important over time. Impressive achievements have been obtained in this field, especially in relations to DNA and RNA sequencing. Since the first achievements by Sanger and colleagues in the 1950s, many sequencing techniques have been developed, while others have disappeared. DNA sequencing has undergone three generations of major evolution. Each generation has its own specifications that are mentioned briefly. Among these generations, nanopore sequencing has its own exciting characteristics that have been given more attention here. Among pioneer technologies being used by the third-generation techniques, nanopores, either biological or solid-state, have been experimentally or theoretically extensively studied. All sequencing technologies have their own advantages and disadvantages, so nanopores are not free from this general rule. It is also generally pointed out what research has been done to overcome the obstacles. In this review, biological and solid-state nanopores are elaborated on, and applications of them are also discussed briefly.  相似文献   

4.
In this paper, we described an integrated modularized microfluidic system that contained two distinct functional modules, one for nucleic acids (NA) extraction and the other for digital PCR (dPCR), allowing for detecting the bovine DNA in ovine tissue.  相似文献   

5.
A label-free method for DNA sequencing based on the principle of the Millikan oil drop experiment was developed. This sequencing-by-synthesis approach sensed increases in bead charge as nucleotides were added by a polymerase to DNA templates attached to beads. The balance between an electrical force, which was dependent on the number of nucleotide charges on a bead, and opposing hydrodynamic drag and restoring tether forces resulted in a bead velocity that was a function of the number of nucleotides attached to the bead. The velocity of beads tethered via a polymer to a microfluidic channel and subjected to an oscillating electric field was measured using dark-field microscopy and used to determine how many nucleotides were incorporated during each sequencing-by-synthesis cycle. Increases in bead velocity of approximately 1% were reliably detected during DNA polymerization, allowing for sequencing of short DNA templates. The method could lead to a low-cost, high-throughput sequencing platform that could enable routine sequencing in medical applications.  相似文献   

6.
DNA microarray and next-generation DNA sequencing technologies are important tools for high-throughput genome research, in revealing both the structural and functional characteristics of genomes. In the past decade the DNA microarray technologies have been widely applied in the studies of functional genomics, systems biology and pharmacogenomics. The next-generation DNA sequencing method was first introduced by the 454 Company in 2003, immediately followed by the establishment of the Solexa and Solid techniques by other biotech companies. Though it has not been long since the first emergence of this technology, with the fast and impressive improvement, the application of this technology has extended to almost all fields of genomics research, as a rival challenging the existing DNA microarray technology. This paper briefly reviews the working principles of these two technologies as well as their application and perspectives in genome research. Supported by the National High-Tech Research Program of China (Grant No.2006AA020704) and Shanghai Science and Technology Commission (Grant No. 05DZ22201)  相似文献   

7.
DNA methylation strongly affects chromatin structure and the regulation of gene expression. For many years, bisulfite sequencing PCR (BSP) has served as the “gold standard” for measuring DNA methylation. However, with the evolution of pyrosequencing as a tool to evaluate DNA methylation, the need arises to compare the relative efficiencies of the two techniques in measuring DNA methylation. We provide for the first time a direct assessment of BSP and pyrosequencing to detect and quantify hypomethylation, hypermethylation, and mixed methylation of the ABCB1 promoter in various drug-sensitive and drug-resistant MCF-7 breast cancer cell lines through head-to-head experimentation. Our findings indicate that although both methods can reliably detect increased, decreased, and mixed methylation of DNA, BSP appears to be more sensitive than pyrosequencing at detecting strong hypermethylation of DNA. However, we also observed greater variability in the methylation of CpG sites by BSP, possibly due to the additional bacterial cloning step required by BSP over pyrosequencing. BSP and pyrosequencing equally detected hypomethylation and mixed methylation of DNA. The ability of pyrosequencing to reliably detect differences in DNA methylation across cell populations without requiring the cloning of bisulfite-treated DNA into bacterial expression vectors was seen as a major advantage of this technique.  相似文献   

8.
A simple technique for direct sequencing of PCR-amplified templates without purification of the PCR reaction product is presented. This method does not require an additional synthesis step after template amplification, and can generate sequence information form as little as 0.1 fmol of unpurified template.  相似文献   

9.
Pyrosequencing is a bioluminometric DNA sequencing technique that measures the release of pyrophosphate during DNA synthesis. The amount of pyrophosphate is proportionally converted into visible light by a cascade of enzymatic reactions. Pyrosequencing has heretofore been used for generating short sequence reads (1-100 nucleotides) because certain factors limit the system's ability to perform longer reads accurately. In this study, we have characterized the main read length limiting factors in both three-enzyme and four-enzyme Pyrosequencing systems. A new simulation model was developed to simulate the read length of both systems based on the inhibitory factors in the chemical equations governing each enzymatic cascade. Our results indicate that nonsynchronized extension limits the obtained read length, albeit to a different extent for each system. In the four-enzyme system, nonsynchronized extension due mainly to a decrease in apyrase's efficiency in degrading excess nucleotides proves to be the main limiting factor of read length. Replacing apyrase with a washing step for removal of excess nucleotide proves to be essential in improving the read length of Pyrosequencing. The main limiting factor of the three-enzyme system is shown to be loss of DNA fragments during the washing step. If this loss is minimized to 0.1% per washing cycle, the read length of Pyrosequencing would be well beyond 300 bases.  相似文献   

10.
A simple method for the identification of gap-bridging subclones in DNA sequencing is described.This work was carried out in the laboratory of Dr Johnston at the John Innes Institute, Norwich, NR4 7UH, UK.  相似文献   

11.
A new approach for optically sequencing ensembles of single DNA molecules using DNA polymerase to mediate the consecutive incorporation of fluorochrome-labeled nucleotides into an array of large single DNA molecules is presented. The approach utilizes cycles of labeled fluorochrome addition, detection to count incorporations, and bleaching to reset the counter. These additions are imaged and analyzed to estimate the number of labeled additions and to correlate them on a per-locus basis along DNA backbones. Initial studies used precisely labeled polymerase chain reaction products to aid the development and validation of simple models of fluorochrome point spread functions within the imaging system. In complementary studies, nucleotides labeled with the fluorochrome R110 were incorporated into surface-elongated lambda DNA, and fluorescent signals corresponding to the addition of R110-dUTP were counted and assigned precise loci along DNA backbones. The labeled DNAs were then subjected to photobleaching and to a second cycle of addition of R110-labeled nucleotides-a second round of additions was correlated with the first to establish strings of addition histories among the ensemble of largely double-stranded templates. These results confirm the basic operational validity of this approach and point the way to the development of a practical system for optical sequencing.  相似文献   

12.
The incorporation of a multicomponent, cofactor-dependant P450 into a microfluidic biochip is demonstrated. The PikC hydroxylase Streptomyces venezuelae was incorporated into a PDMS-based microfluidic channel. The enzyme was immobilized to Ni-NTA agarose beads via in situ attachment following the addition of the beads to the microchannel. The enzyme loading was approximately 6 microg per mg of beads resulting in a microchannel loading of 10.7 mg/mL. This high enzyme loading enabled the rapid hydroxylation of the macrolide YC-17 to methymycin and neomethymycin in about equal amounts with a conversion of >90% at a flow rate of 70 nL/min. This high reactivity allowed rapid hydroxylation reactions to be performed with short residence times, which is critical for complex enzymes with limited inherent stability.  相似文献   

13.
Pyrosequencing is a DNA sequencing technique based on sequencing-by-synthesis enabling rapid and real-time sequence determination. Although ample genomic research has been undertaken using pyrosequencing, the requirement of relatively high amount of DNA template and the difficulty in sequencing the homopolymeric regions limit its key advantages in the applications directing towards clinical research. In this study, we demonstrate that pyrosequencing on homopolymeric regions with 10 identical nucleotides can be successfully performed with optimal amount of DNA (0.3125-5 pmol) immobilized on conventional non-porous Sepharose beads. We also validate that by using porous silica beads, the sequencing signal increased 3.5-folds as compared to that produced from same amount of DNA immobilized on solid Sepharose beads. Our results strongly indicate that with optimized quantity of DNA and suitable solid support, the performance of pyrosequencing on homopolymeric regions and its detection limit has been significantly improved.  相似文献   

14.
ABSTRACT

Here, we show that semiconductor-based sequencing technology can be used to map mammalian replication domains, chromosomal units with similar DNA replication timing. Replicating DNA purified from mammalian cells was successfully sequenced by the Ion Torrent platform. The resultant replication domain map of mouse embryonic stem cells is comparable to those obtained by the conventional microarray-based method.  相似文献   

15.
System for DNA sequencing with resolution of up to 600 base pairs   总被引:16,自引:0,他引:16  
A system capable of resolving about 500 bases is of interest for sequencing of longer DNA molecules. Studies on further optimization of resolution on DNA sequencing gels were carried out. The effect of physico-chemical properties of gels and buffers on resolution were tested, e.g. ionic strength and pH of buffers, different buffer systems, acrylamide concentration, crosslinker concentration, type of crosslinker, temperature of polymerization, denaturing conditions, gel length and thickness. Tested were as well different running conditions like electric field, gel temperature, dimension of sample slots. Gels 0.1-0.2 mm thick and up to 1.2 m long were cast and tested routinely. Gel lengths of 60-70 cm (for sequencing up to 350-400 bases) to about 100 cm (above 400 bases) are practicable. Little is gained in resolution by increasing the gel length from 1 to 1.2 m. Resolution was improved using 0.1 mm thick gels, at a higher pH value of 8.6-8.8, and molarity increased to 0.2 M. The sequencing pattern in the region of higher bases could be better resolved on a twice-magnified picture of that region on the autoradiogram. With the long gels (70-120 cm), it is advantageous to obtain the sequence overlap by running in parallel gels of different concentrations, without re-application of samples, all loaded at the same time. Buffer chamber for running of two of three gels and thermostating plates up to 1.2 m long were designed. In this way four to six thermostated gels can be run from a power supply with two inputs. Three 1 m long gels (concentrations: 4%, 6%, 12-16%) are loaded with several samples of DNA to be sequenced and run in parallel without re-application of the samples. With good samples, the sequence overlap from the gels could be counted up to 500 base pairs, with exceptionally good samples closer to 600 bases. At present this number seems to be near the limit of the resolving power of the polyacrylamide gels.  相似文献   

16.
RAre DAmage and Repair sequencing (RADAR-seq) is a highly adaptable sequencing method that enables the identification and detection of rare DNA damage events for a wide variety of DNA lesions at single-molecule resolution on a genome-wide scale. In RADAR-seq, DNA lesions are replaced with a patch of modified bases that can be directly detected by Pacific Biosciences Single Molecule Real-Time (SMRT) sequencing. RADAR-seq enables dynamic detection over a wide range of DNA damage frequencies, including low physiological levels. Furthermore, without the need for DNA amplification and enrichment steps, RADAR-seq provides sequencing coverage of damaged and undamaged DNA across an entire genome. Here, we use RADAR-seq to measure the frequency and map the location of ribonucleotides in wild-type and RNaseH2-deficient E. coli and Thermococcus kodakarensis strains. Additionally, by tracking ribonucleotides incorporated during in vivo lagging strand DNA synthesis, we determined the replication initiation point in E. coli, and its relation to the origin of replication (oriC). RADAR-seq was also used to map cyclobutane pyrimidine dimers (CPDs) in Escherichia coli (E. coli) genomic DNA exposed to UV-radiation. On a broader scale, RADAR-seq can be applied to understand formation and repair of DNA damage, the correlation between DNA damage and disease initiation and progression, and complex biological pathways, including DNA replication.  相似文献   

17.
Dideoxy DNA sequencing with end-labeled oligonucleotide primers   总被引:17,自引:0,他引:17  
End-labeled oligonucleotide primers may be used effectively as the source of radiolabel in DNA sequencing by the dideoxy method. The approach is demonstrated with various end-labeled oligonucleotides, including a commercially prepared universal primer and a mixed-sequence probe. Single-stranded (M13) or denatured double-stranded template may be used. The end-labeled primers and their extension products may be stored for weeks. The method is useful for identification of clones isolated by oligonucleotide hybridization and it provides a convenient, economical alternative to the use of alpha-labeled deoxynucleoside triphosphate.  相似文献   

18.
19.
Type specimens have high scientific importance because they provide the only certain connection between the application of a Linnean name and a physical specimen. Many other individuals may have been identified as a particular species, but their linkage to the taxon concept is inferential. Because type specimens are often more than a century old and have experienced conditions unfavourable for DNA preservation, success in sequence recovery has been uncertain. This study addresses this challenge by employing next‐generation sequencing (NGS) to recover sequences for the barcode region of the cytochrome c oxidase 1 gene from small amounts of template DNA. DNA quality was first screened in more than 1800 century‐old type specimens of Lepidoptera by attempting to recover 164‐bp and 94‐bp reads via Sanger sequencing. This analysis permitted the assignment of each specimen to one of three DNA quality categories – high (164‐bp sequence), medium (94‐bp sequence) or low (no sequence). Ten specimens from each category were subsequently analysed via a PCR‐based NGS protocol requiring very little template DNA. It recovered sequence information from all specimens with average read lengths ranging from 458 bp to 610 bp for the three DNA categories. By sequencing ten specimens in each NGS run, costs were similar to Sanger analysis. Future increases in the number of specimens processed in each run promise substantial reductions in cost, making it possible to anticipate a future where barcode sequences are available from most type specimens.  相似文献   

20.
A cost-effective, reliable, and reproducible method has been developed to produce good-quality, double-stranded plasmid DNA for automated sequence analysis. The method incorporates modifications to a previously described plasmid-purification protocol used in manual sequencing. The quality of the DNA produced from the present protocol is suitable for automated fluorescent sequencing. Using a dye-terminator sequencing protocol, most runs using plasmid DNA prepared using this protocol produced over 700 bases with greater than 99% base-calling accuracy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号