首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到16条相似文献,搜索用时 171 毫秒
1.
Er,Cr:YSGG激光照射对牙根尖封闭效果影响的实验研究   总被引:3,自引:0,他引:3  
目的:深入探讨在根尖倒充填术中Er,Cr:YSGG激光照射对牙根尖的封闭效果,为此激光在口腔临床上的应用与推广提供重要的理论与实验依据。方法:将56颗新拔除的单根牙随机分成7组,每组8颗牙。去除牙冠,常规进行根管预备、根管充填。将倒充填的牙根尖进行预备,然后银汞合金倒充填。预备方法:1手机切除根尖后,制备成烧瓶状洞形;2手机处理方法同1,然后Er,Cr:YSGG激光于不同能量(1W、2W)及不同方式(喷水或无水)下对洞内壁进行照射。结合微渗漏检测与扫描电镜观察对Er,Cr:YSGG激光照射后的牙根尖封闭效果进行评估。结果:Er,Cr:YSGG激光可有效去除根切面上的玷污层及碎屑;与手机加银汞倒充填组相比,激光照射后的根尖染料微渗漏深度有所减少;但只有1WEr,Cr:YSGG激光于无水条件下照射时,根尖染料微渗漏深度显著减少(P<0.05)。结论:Er,Cr:YSGG激光应用于根尖倒充填术中可减少微渗漏的发生;促进根尖封闭;在特定的能量参数下可获得优于常规银汞倒充填术的治疗效果。因此我们推荐临床上将Er,Cr:YSGG激光照射与常规银汞倒充填术结合使用,这将有助于提高根尖倒充填术治疗的成功率。  相似文献   

2.
目的:观察不同能量输出的Er,C r:YSGG激光照射对牙周病牙根面的影响,探讨Er,C r:YSGG激光用于牙周治疗的可行性和有效性。方法:选择因牙周病松动Ⅲo而拔除牙12颗,随机分3组,每组4颗。分别以1.5 W、2.0 W、2.5 W激光照射。扫描电镜(SEM)观察各组牙根表面和纵剖面。结果:低倍镜下各组根面改变无明显差异,表面干净,粗糙程度均匀,未见明显弹坑状痕迹;高倍镜下1.5 W激光照射组显示根面粗糙程度更均匀一致,无弹坑状改变,无熔融、炭化迹象,未见牙本质小管暴露。结论:Er,C r:YSGG激光能有效去除牙周病牙根面玷污层及病变牙骨质,根面无熔融、炭化等改变。1.5 W激光照射组优于2.0 W组和2.5 W组。  相似文献   

3.
Er,Cr:YSGG激光处理正常及龋坏牙本质的扫描电镜观察   总被引:12,自引:2,他引:10  
目的:利用扫描电镜观察Er,Cr:YSGG激光处理龋坏牙本质的形态学改变,并与常规方法进行比较。方法:将24颗新拔除的患龋牙随机分成2组,每组12颗牙。第1组常规处理组:分别用金刚砂石针、碳钢裂钻和挖器处理正常及龋坏牙本质;第2组激光处理组:分别用2WEr,Cr:YSGG激光、4WEr,Cr:YSGG激光处理正常及龋坏牙本质。常规制片,扫描电镜下观察。结果:与常规方法相比,激光处理后的牙本质表面不平,呈鱼鳞状、片状的粗糙外观;表面清洁,无玷污层,牙本质小管口清晰可见;4W激光作用时偶见微裂;激光处理后的牙本质表面具有增加树脂黏结性的形态学改变.结论:Er,Cr:YSGG激光能有效地清除龋坏牙本质及玷污层,并可使牙体组织发生一定的形态学改变。因此,Er,Cr:YSGG激光能够替代常规去龋备洞方法。  相似文献   

4.
目的:寻找一种预备C形根管的有效器械,提高下颌第二恒磨牙的治愈率。方法:选用80颗具有C形根管的下颌第二恒磨牙,选择四种器械进行根管预备,第一组用不锈钢K锉,第二组用不锈钢K锉和手用镍钛器械,第三组用机用镍钛器械,第四组用超声根管治疗仪,预备中均用3%双氧水和生理盐水交替反复冲洗根管,预备后用Vitapex糊剂和牙胶尖冷侧压方法充填根管,观察根充后X线片和根尖微渗漏情况,评价充填效果。结果:四种器械根充后微渗漏有明显差异(P<0.05)。结论:不锈钢K锉和手用镍钛器械联合应用及超声根管治疗仪为预备C形根管的有效器械。  相似文献   

5.
目的:评价机用ProTaper镍钛根管器械进行恒磨牙根管预备的临床疗效。方法:2007年7月至2010年12月期间就诊的需进行根管治疗的109患者,共计128颗磨牙,包括牙髓炎54颗牙,慢性根尖周炎74颗牙。按随机配对原则分入实验组和对照组,每组64颗牙。实验组用机用ProTaper镍钛根管锉预备根管,对照组用不锈钢K型锉预备根管。两组均采用侧向加压法充填根管,记录每颗患牙的单个根管预备所用时间、根管充填效果、术后不良反应及随访到的远期疗效。结果:机用ProTaper镍钛器械预备单根管所耗时间明显少于对照组,根管预备后疼痛发生率明显低于对照组,根管适充率实验组明显优于对照组,根管治疗术后1年疗效比较也优于对照组。结论:使用机用ProTaper器械进行恒磨牙根管预备快速有效,根充效果好,并发症发生率低,远期疗效确切,值得临床推广。  相似文献   

6.
郝艳红  彭一纯  梁洁  徐英新  李阅 《生物磁学》2011,(13):2497-2498,2492
目的:寻找一种预备C形根管的有效器械,提高下颌第二恒磨牙的治愈率。方法:选用80颗具有C形根管的下颌第二恒磨牙,选择四种器械进行根管预备,第一组用不锈钢K锉,第二组用不锈钢K锉和手用镍钛器械,第三组用机用镍钛器械,第四组用超声根管治疗仪,预备中均用3%双氧水和生理盐水交替反复冲洗根管,预备后用Vitapex糊剂和牙胶尖冷侧压方法充填根管,观察根充后X线片和根尖微渗漏情况,评价充填效果。结果:四种器械根充后微渗漏有明显差异(P〈0.05)。结论:不锈钢K锉和手用镍钛器械联合应用及超声根管治疗仪为预备C形根管的有效器械。  相似文献   

7.
目的:利用红外成像仪测定System B技术根管充填治疗时根管表面温度的变化,以避免牙周组织损伤,探索有良好的根管充填效果的System B工作温度,为System B的临床应用和推广提供依据。方法:选取临床拔除的双根管离体牙30颗,随机分成6组(1a、2a、3a、1b、2b、3b),每组5颗牙齿。1、2、3组充填时,System B技术温度分别设定为160℃、180℃、200℃,a组充填前不使用封闭剂,b组充填前使用封闭剂。使用System B连续波热牙胶技术进行根尖部充填,根管内向下挤压涂布根管封闭剂的0.06锥度主牙胶尖,到达距根尖5 mm处,作用2-5 s。充填过程中使用红外热成像仪进行拍照,分别记录根管表面的温度变化情况。采用染料渗透法评估每组牙的微渗漏情况,使用1%亚甲蓝染液对离体牙进行染色,透明处理后于体视显微镜下测量染料渗入牙根的长度。结果:在System B不同工作温度设定下,牙根表面温度升高值的差异有统计学意义(P0.05);封闭剂组的使用与否对牙根表面温度升高值的差异无统计学意义(P0.05);充填温度设定为160℃、180℃时,使用封闭剂能够减少微渗漏的产生(P0.05);温度设定在180℃和200℃时,微渗漏的大小无明显差异(P0.05)。当温度设定在160℃时,其微渗漏较180℃、200℃温度组有明显差异(P0.05);当温度设定为200℃时,封闭剂的使用与否对微渗漏无明显影响(P0.05)。结论:使用System B技术充填根管过程中,工作温度的设定会影响根管充填后的封闭,当温度设定在160℃时,对牙组织无损伤,牙根表面的温度变化随着System B工作温度的升高而增加,提示加热温度不要过高,以避免对牙周组织造成损伤。在封闭剂使用情况相同的前提下,工作温度为200℃与180℃时,根管充填效果无明显差异,封闭剂的使用与否在200℃时对充填效果无明显影响,在180℃和160℃时使用封闭剂能保证根管的充填效果。  相似文献   

8.
目的:热垂直加压技术是目前应用广泛的根管充填技术.它利用牙胶加热后良好的流动性,严密的充填根管系统.成功的根管治疗需要性能良好的根管糊剂和规范的临床操作.基于以上特点,本实验探索两种不同根管糊剂及System B携热器工作尖与根尖孔的距离对热牙胶垂直加压充填根管根尖封闭能力的影响.方法:离体单根牙96颗,在釉牙骨质界处截去牙冠,采用冠向下法将根管预备至F3,冲洗后备用.将所有预备后的标本随机分为10组,其中实验组6组,对照组4组.分别采用美松和AH-Plus两种糊剂,System B携热器工作尖与根尖孔的距离分别为4mm、5mm、6mm.在根管壁上涂布少量的根管糊剂,插入预先试好的大锥度牙胶尖,用System B技术充填根管的根尖部分,冠方用Obtura Ⅱ技术充填.对标本进行染色及透明化处理后分析染料渗入长度进行分析,并通过扫描电镜观察根尖区根管充填材料与根管壁之间的结合形态.结果:AH-Plus组的染料渗入长度明显小于美松组,两者差距有统计学意义(P<0.05).System B携热器工作尖与根尖孔的距离为4mm时微渗漏值较小,且与其它两组比较有统计学差异(P<0.05).扫描电镜下观察各实验组的根管充填材料与根管壁之间都存在缝隙.结论:在临床操作中建议使用AH-Plus糊剂,并且将System B携热器工作尖与根尖孔的距离设置为4mm,以提高根管封闭性能、规范临床操作.  相似文献   

9.
目的:观察新型激光光敏根管消毒剂、甲苯胺蓝和亚甲基蓝在牙本质中的渗透效果,评价三种光敏剂在牙本质中的渗透性。方法:收集新鲜拔除的离体单根管牙90颗,根管预备后随机分为三组。每组30颗。A组为新型激光光敏根管消毒剂组;B组为甲苯胺蓝组;C组为亚甲基蓝组。A、B、C三组实验根管内分别用浸有饱和的新型激光光敏根管消毒剂、甲苯胺蓝和亚甲基蓝的棉捻在根管内停留60秒。沿牙体长轴颊舌纵向劈开,倒置荧光显微镜下观察并拍照,用Photoshop8.01软件测量三种光敏剂渗透入牙本质的平均深度。结果:新型激光光敏根管消毒剂在牙本质内的渗透平均深度为553.25μm,甲苯胺蓝在牙本质内的渗透平均深度为350.75μm,亚甲基蓝在牙本质内的渗透平均深度为168.25μm。结论:新型激光光敏根管消毒剂在牙本质渗透性明显优于甲苯胺蓝和亚甲基蓝,具有良好的牙本质渗透性。  相似文献   

10.
为了观察脉冲Nd:YAG激光在根管预备(以下简称根备)中的作用,我们用Nd:YAG激光辅助,以30颗患牙进行根备,根备后即时根充。并与超声根备后即时根充、传统根备后即时根充比较,结果表明:激光组的术后疼痛反应少于超声组与传统组,远期疗效与超声组相仿,而优于传统组。  相似文献   

11.

Background

The objective of this study was to investigate the influence of Er,Cr:YSGG laser irradiated at different powers on the micromorphology and the bonding property of non-carious sclerotic dentin to resin composites.

Methods

Two hundred bovine incisors characterized by non-carious sclerotic dentin were selected, and the seventy-two teeth of which for surface morphological analysis were divided into nine groups according to various treatments (A: the control group, B: only treated with the adhesive Adper Easy One, C: diamond bur polishing followed by Adper Easy One, D-I: Er,Cr:YSGG laser irradiating at 1W, 2W, 3W, 4W, 5W, 6W output power, respectively, followed by Adper Easy One). The surface roughness values were measured by the non-contact three-dimensional morphology scanner, then the surface micromorphologies of surfaces in all groups were assessed by scanning electron microscopy (SEM); meanwhile, Image Pro-Plus 6.0 software was used to measure the relative percentage of open tubules on SEM images. The rest, one hundred twenty-eight teeth for bond strength test, were divided into eight groups according to the different treatments (A: only treated with the adhesive Adper Easy One, B: diamond bur polishing followed by the above adhesive, C-H: Er,Cr:YSGG laser irradiating at 1 W, 2 W, 3 W, 4 W, 5 W, 6 W output power, respectively, followed by the above adhesive), and each group was subsequently divided into two subgroups according to whether aging is performed (immediately tested and after thermocycling). Micro-shear bond strength test was used to evaluate the bond strength.

Results

The 4W laser group showed the highest roughness value (30.84±1.93μm), which was statistically higher than the control group and the diamond bur groups (p<0.05). The mean percentages ((27.8±1.8)%, (28.0±2.2)%, (30.0±1.9)%) of open tubules area in the 4W, 5W, 6W group were higher than other groups (p<0.05). The 4W laser group showed the highest micro-shear bond strength not only in immediately tested (17.60±2.55 PMa) but after thermocycling (14.35±2.08MPa).

Conclusion

The Er,Cr:YSGG laser at 4W power can effectively improve the bonding property between non-carious sclerotic dentin and resin composites by increasing the roughness and mean percentage area of open tubules.  相似文献   

12.
本文用 1千牛电液疲劳实验机检测充填材料与牙面之间的粘结力 ,发现 :在牙釉质组中 ,酸蚀组、6瓦激光切割组及 6瓦激光切割联合酸蚀组抗剪切粘结强度无显著性差异 (P >0 .0 5) ;在牙本质组中 ,酸蚀组、4瓦激光切割组及 4瓦激光切割联合酸蚀组抗剪切粘结强度也无显著性差异 (P >0 .0 5)。并通过SEM观察激光处理后牙体表面结构的变化 ,发现激光切割后牙釉质表面不平呈层状 ,无玷污层 ,釉柱未见破坏 ;牙本质小管开放 ,表面无玷污层 ,达到酸蚀的效果。因此Er,Cr :YSGG激光切割牙体硬组织具有传统钻切割与酸蚀刻的联合作用 ,可以代替传统的酸蚀方法。  相似文献   

13.
用波长1.06μm,输出功率20W的Nd∶YAG激光照射根管壁后,常规根管糊剂+牙胶尖侧压法充填。对照组,直接根管充填。通过测量酚醛树脂在根管横截面中所占面积比值和染料渗入长度,发现实验组和对照组之间无明显差异(P>0.05)。认为单纯激光照射对根尖封闭能力的影响并不明显。激光照射在根管治疗术中的作用可能是通过其它途径。  相似文献   

14.
目的:研究不同形态的箍结构对纤维桩核修复冠方微渗漏的影响。方法:选择因正畸治疗需要而拔除的下颌单根管前磨牙50颗,随机分成5个组:完整箍结构组(第1组)、1面缺损的箍结构组(第2组)、2面缺损的箍结构组(第3组)、3面缺损的箍结构组(第4组)以及无箍结构组(第5组)。所有标本经纤维桩核修复后模拟口内老化情况,并经染色处理,在体式显微镜下记录各组微渗漏的情况。结果:第1组的微渗漏情况最轻,第5组的微渗漏情况最重。第1、2、3组之间微渗漏情况无统计学差异(P0.05),第2、3组和第4组之间微渗漏情况均无统计学差异(P0.05)。但第1组和第4、5组间微渗漏差异有统计学意义(P0.05),第2、3组和第5组间微渗漏差异有统计学意义(P0.05)。结论:牙体修复时至少应保留一面牙本质肩领,即使在没有完整箍结构的情况下也能获得良好的修复效果。  相似文献   

15.
目的:比较热牙胶充填与冷牙胶侧方加压在根管充填中应用的临床效果。方法:选择62例急性牙髓炎和根尖周炎患者,均分后分别选择热牙胶充填与冷牙胶侧方加压的方法进行根管充填,比较两组患者根管充填时间、术后牙周疼痛病例和术后3个月后充填质量及临床疗效。结果:两组患者术后牙周疼痛病例比较,差异无统计学意义(P>0.05);其余各方面比较,差异均均有统计学意义(P>0.05),热牙胶组优于冷牙胶组。结论:临床进行根管充填治疗时,应首选热牙胶充填的方式,可显著提高临床疗效,且不增加患者术后牙周疼痛的发生。  相似文献   

16.
The physical mechanisms that achieve tissue removal through the delivery of short pulses of high-intensity infrared laser radiation, in a process known as laser ablation, remain obscure. The thermodynamic response of biological tissue to pulsed infrared laser irradiation was investigated by measuring and analyzing the stress transients generated by Q-sw Er:YSGG (lambda = 2.79 microns) and TEA CO2 (lambda = 10.6 microns) laser irradiation of porcine dermis using thin-film piezoelectric transducers. For radiant exposures that do not produce material removal, the stress transients are consistent with thermal expansion of the tissue samples. The temporal structure of the stress transients generated at the threshold radiant exposure for ablation indicates that the onset of material removal is delayed with respect to irradiation. Once material removal is achieved, the magnitude of the peak compressive stress and its variation with radiant exposure are consistent with a model that considers this process as an explosive event occurring after the laser pulse. This mechanism is different from ArF- and KrF-excimer laser ablation where absorption of ultraviolet radiation by the collagenous tissue matrix leads to tissue decomposition during irradiation and results in material removal via rapid surface vaporization. It appears that under the conditions examined in this study, explosive boiling of tissue water is the process that mediates the ablation event. This study provides evidence that the dynamics and mechanism of tissue ablation processes can be altered by targeting tissue water rather than the tissue structural matrix.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏