首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Methylhippuric acid isomers (MHAs), urinary metabolites of xylenes, were determined, after clean-up by C18-SPE and esterification with hexafluoroisopropanol and diisopropylcarbodiimide, by GC with ECD detection, on an SPB-35 capillary column (30 m, 0.32 mm I.D., 0.25 μm film thickness, β=320). S-benzyl-mercapturic acid was used for internal standardization. Chromatographic conditions were: oven temperature 162°C, for 14.2 min; ramp by 30°C/min to 190°C, for 3.5 min; ramp by 30°C/min to 250°C, for 4 min; helium flow rate: 1.7 ml/min; detector and injector temperature: 300°C. The sample (1 μl) was injected with a split injection technique (split ratio 5:1). MHA recovery was >95% in the 0.5–20 μmol/l range; the limit of detection was <0.25 μmol/l; day-to-day precision, at 2 μmol/l, was Cv<10%. Urinary MHAs were determined in subjects exposed to different low-level sources of xylenes: (a) tobacco smoking habit and (b) BTX urban air pollution (airborne xylene ranging from 0.1 to 3.7 μmol/m3). Study (a) showed a significant difference between urinary MHA median excretion values of nonsmokers and smokers (4.6 μmol/l vs. 8.1 μmol/l, p<0.001). Study (b) revealed a significant difference between indoor workers and outdoor workers (4.3 μmol/l vs. 6.9 μmol/l, p<0.001), and evidenced a relationship between MHAs (y, μmol/mmol creatinine) and airborne xylene (x, μmol/m3) (y=0.085+0.34x; r=0.82, p<0.001, n=56). Proposed biomarkers could represent reliable tools to study very low-level exposure to aromatic hydrocarbons such as those observed in the urban pollution due to vehicular traffic or in indoor air quality evaluation.  相似文献   

2.
A sensitive HPLC method for the determination of phenol and chlorophenols was developed. The fluorescence labeling reaction of phenols with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) was completed in 30 min at 60°C. The separation of DIB-derivatives of five representative phenols, i.e., phenol, o-, p-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, was achieved within 35 min with an ODS column using isocratic elution. The detection limits of these DIB derivatives at a signal-to-noise ratio (S/N) of 3 were in the range of 0.024 to 0.08 μM (0.12–0.45 pmol/20 μl injection). Twelve kinds of DIB derivatives with phenols containing mono-, di-, tri-, tetra- and penta-chlorophenol were also well separated within 208 min by changing the elution conditions. The derivatives were stable for at least for 24 h when they were placed at room temperature in the dark. The proposed method was applied to the assay of human urine samples and free and total phenol were determined. The relative standard deviations (RSDs) of the proposed method for within and between-day assay were <7.0% and <14.2%, respectively. The average concentrations of free and total phenol found in urine (n=6) were 4.3±2.5 and 29.5±14.0 μM, respectively.  相似文献   

3.
A method is reported for determination of allantoin in urine and plasma based on high-performance liquid chromatography (HPLC) and pre-column derivatization. In the derivatization procedure, allantoin is converted to glyoxylic acid which forms a hydrazone with 2,4-dinitrophenylhydrazine. The hydrazone appears as syn and anti isomers at a constant ratio. These derivatives are separated by HPLC using a reversed-phase C18 column from hydrazones of other keto acids possibly present in urine and plasma and then monitored at 360 nm. All components were completely resolved in 15 min. Both the reagents and derivatization products are stable. Recovery of allantoin added to urine and plasma was 95 ± 3.7% (n = 45) and 100 ± 7.5% (n = 64), respectively. The lowest allantoin concentration that gave a reproducible integration was 5 μmol/l. The between-assay and within-day coefficients of variation were 2.8 and 0.6%, respectively.  相似文献   

4.
For the quantification of nitrite and nitrate, the stable metabolites of -arginine-derived nitric oxide (NO) in human urine and plasma, we developed a gas chromatographic—mass spectrometric (GC—MS) method in which [15N]nitrite and [15N]nitrate were used as internal standards. Endogenous nitrite and [15N]nitrite added to acetone-treated plasma and urine samples were converted into their pentafluorobenzyl (PFB) derivatives using PFB bromide as the alkylating agent. For the analysis of endogenous nitrate and [15N]nitrate they were reduced to nitrite and [15N]nitrite, respectively, by cadmium in acidified plasma and urine samples prior to PFB alkylation. Reaction products were extracted with toluene and 1-μl aliquots were analyzed by selected-ion monitoring at m/z 46 for endogenous nitrite (nitrate) and m/z 47 for [15N]nitrite ([15N]nitrate). The intra- and inter-assay relative standard deviations for the determination of nitrite and nitrate in urine and plasma were below 3.8%. The detection limit of the method was 22 fmol of nitrite. Healthy subjects (n = 12) excreted into urine 0.49 ± 0.25 of nitrite and 109.5 ± 61.7 of nitrate (mean ± S.D., μmol/mmol creatinine) with a mean 24-h output of 5.7 μmol for nitrite and 1226 μmol for nitrate. The concentrations of nitrite and nitrate in the plasma of these volunteers were determined to be (mean ± S.D., μmol/l) 3.6 ± 0.8 and 68 ± 17, respectively.  相似文献   

5.
A high-performance liquid chromatographic assay with solid-phase extraction (SPE) for the rapid and sensitive quantitation of 3-(5-cyclopropyl-1,2,4-oxadiazol-3-yl)-5-(1-methylethyl)imidazo[1,5-a]quinoxalin-4(5H)-one (I, U-78875) in serum is described. The validation results indicated that the present method had excellent intra- and inter-assay precision (≤ 9.5%, mean ± S.D. = 3.9±3.0%, n = 25) and accuracy (≤ 10.0%, mean ± S.D. = 3.0 ± 2.9%, n = 25), as well as improved sensitivity (2 ng/ml, using a 100-μl injection). Each chromatographic run is only 10 min and the organic solvent for the extraction of I and internal standard (U-82217) from serum was only 300 μl. The application results obtained from the SPE method were in good agreement with the advanced automated sample preparation method.  相似文献   

6.
A simultaneous assay for droperidol and flunitrazepam by high-performance liquid chromatography has been developed and applied to blood samples collected during an acute normovolemic haemodilution under general anaesthesia. Haemodilution blood samples were stored at +4°C to be transfused, if required, to a patient during the post-surgical phase. A C18 Supelclean cartridge was used for solid-phase extraction, and the recoveries were 74% and 89%, respectively, for droperidol and flunitrazepam. Compounds were chromatographed on a C18 Novapak column at 250 nm, with a mobile phase of acetonitrile—10 mM ammonium acetate buffer (pH 6.7) (45:55, v/v). Nitrazepam was used as the internal standard. For both drugs, the assay was linear up to 500 μg/l, and the detection limits were 20 and 10 μg/l for droperidol and flunitrazepam, respectively, and their observed levels in haemodilution samples were 93 ± 82 μg/l and 76 ± 107 μg/l, respectively. Some of the values for flunitrazepam were higher than the minimal efficient concentration, defined as the plasma level observed at the time of the patient wakening from anaesthesia (12 ± 4 μg/l). According to our results, haemodilution sampling can be performed before induction of anaesthesia. When the blood is collected after the anaesthetic induction, it seems necessary to determine levels of the two drugs in haemodilution samples to avoid side-effects.  相似文献   

7.
All photometric or HPLC methods described to date have been unable to detect nitrite, a reliable marker of NO synthase activity, in human blood because of its rapid metabolism within the erythrocytes. We now elaborate on method to prevent nitrite degradation during sample preparation which in combination with high-performance anion-exchange chromatography and electrochemical detection allows a sensitive measurement of nitrite. A linear current response in the concentration range of 10–1000 nmol/l nitrite was observed yielding a correlation coefficient of 0.99. In addition, the combination of the electrochemical with a UV detector allowed us to simultaneously quantify nitrate one analytical run, which is the end product of NO/nitrite metabolism. Basal levels for nitrate and nitrite in human blood were determined with 25±4 μmol/l and 578±116 nmol/l (n=8), respectively and thus were in the same concentration range as expected from NO measurement in saline perfused isolated organs or cultured endothelial cells. Therefore, the presented method may be used to assess activity of endothelial constitutive NO synthase in humans under physiological and pathophysiological conditions.  相似文献   

8.
An HPLC assay with tandem mass spectrometric detection in the positive-ion Turbo-Ion-Spray (TISP) mode for the fast and sensitive determination of perifosine ((I), D-21266) in human plasma was developed, utilising the structural analogue, miltefosine ((II), D-18506), as internal standard. Automated solid-phase extraction of diluted plasma samples, based on 250-μl plasma aliquots, at pH 6.5, allowed a reliable quantification of perifosine down to 4 ng/ml. Injection of 200 μl of plasma extracts onto a 100×3 mm normal-phase analytical column at a flow-rate of 0.5 ml/min provided retention-times of 2.4 and 2.1 min for perifosine (I) and the internal standard (II), respectively. The standard curves were linear from 4 to 2000 ng/ml using weighted linear regression analysis (1/Y2). The inter-assay and intra-assay accuracies for the calibration standards were within +0.9% and −0.2%, exhibiting precisions (C.V.) of ±6.5 and ±7.3%, respectively. Up to 100 unknowns may be analysed each 24 h per analyst.  相似文献   

9.
Two high-performance liquid chromatographic (HPLC) methods are described for determination of (±)-ethopropazine (ET) in rat plasma. After deproteination and liquid–liquid extraction, assay of (±)-ET was performed using either a C18 column (non-stereospecific assay) or an (α-R-naphthyl)ethylurea column (stereospecific assay). The UV detection was at 250 nm. Mean recovery was >85%. Both assays demonstrated excellent linear relationships between peak height ratios and plasma concentrations; quantitation limits were ≤25 ng/ml, based on 100 μl rat plasma. Accuracy and precision were <17% with both methods. Both methods were applied successfully to the measurement of ET plasma concentrations in rats given the drug intravenously.  相似文献   

10.
3β-Hydroxysteroid dehydrogenase (3β-HSD)/Δ5→4-isomerase activity in steroidogenic tissues is required for the synthesis of biologically active steroids. Previously, by use of dehydroepiandrosterone (3β-hydroxy-5-androsten-17-one, DHEA) as substrate, it was established that in addition to steroidogenic tissues 3β-HSD/Δ5→4-isomerase activity also is expressed in extraglandular tissues of the human fetus. In the present study, we attempted to determine whether the C-5,C-6-double bond of DHEA serves to influence 3β-HSD activity. For this purpose, we compared the efficiencies of a 3β-hydroxy-5-ene steroid (DHEA) and a 3β-hydroxy-5α-reduced steroid (5α-androstane-3β,17β-diol, 5α-A-diol) as substrates for the enzyme. The apparent Michaelis constant (Km) for 5α-A-diol in midtrimester placenta, fetal liver, and fetal skin tissues was at least one order of magnitude higher than that for DHEA, viz the apparent Km of placental 3β-HSD for 5α-A-diol was in the range of 18 to 40 μmol/l (n = 3) vs 0.45 to 4 μmol/l for DHEA (n = 3); for the liver enzyme, 17 μmol/l for 5α-A-diol and 0.60 μmol/l for DHEA, and for the skin enzyme 14 and 0.18 μmol/l, respectively. Moreover, in 13 human fetal tissues evaluated the maximal velocities obtained with 5α-A-diol as substrate were higher than those obtained with DHEA. A similar finding in regard to Kms and rates of product formation was obtained by use of purified placental 3β-HSD with DHEA, pregnenolone, and 3β-hydroxy-5α-androstan-17-one (epiandrosterone) as substrates: the Km of 3β-HSD for DHEA was 2.8 μmol/l, for pregnenolone 1.9 μmol/l, and for epiandrosterone 25 μmol/l. The specific activity of the purified enzyme with pregnenolone as substrate was 27 nmol/mg protein·min and, with epiandrosterone, 127 nmol/mg protein·min. With placental homogenate as the source of 3β-HSD, DHEA at a constant level of 5 μmol/l behaved as a competitive inhibitor when the radiolabeled substrate, [3H]5α-A-diol, was present in concentrations of 20 to 60 μmol/l, but a lower substrate concentrations the inhibition was of the mixed type; similar results were obtained with [3H]DHEA as the substrate at variable concentrations in the presence of a fixed concentration of 5α-A-diol (40 μmol/l). These findings are indicative that both steroids bind to a common site on the enzyme, however, the binding affinity for these steroids appear to differ markedly as suggested by the respective Kms. Studies of inactivation of purified placental 3β-HSD/Δ5→4-isomerase by an irreversible inhibitor, viz 5,10-secoestr-4-yne-3,10,17-trione, were suggestive that the placental protein adopts different conformations depending on whether the steroidal substrate has a 5α-configuration, e.g. epiandrosterone, or a C-5,C-6-double bond e.g. DHEA or pregnenolone. The lower rates of product formation obtained with placenta and fetal tissues by use of 3β-hydroxy-5-ene steroids as substrates when compared with those obtained with 3β-hydroxy-5α-reduced steroids may be explained by a combination of factors, including: (i) inhibition of 3β-HSD activity by end products of metabolism of 3β-hydroxy-5-ene steroids, e.g. 4-androstene-3,17-dione formed with DHEA as substrate; (ii) higher binding affinity of the enzyme for 3β-hydroxy-5-ene steroids—and possibly for their 3-oxo-5-ene metabolites; (iii) lack of a requirement for the isomerization step with 5α-reduced steroids as substrates, and (iv) the possible presence in fetal tissues of an enzyme with 3β-HSD activity only (i.e. no Δ5→4-isomerase).  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of flumequine and its metabolite 7-hydroxyflumequine in sheep plasma was described. The two compounds were extracted from 100 μl of plasma by liquid–liquid extraction. Aliquots (100 μl) were injected onto the HPLC system and separated on a LiChrospher Select B column with an isocratic system. The compounds were detected by fluorimetric detection for concentrations below 500 μg/l and by UV detection for the concentrations exceeding 500 μg/l. The range of the validated concentrations were 50 000 to 5 μg/l and 500 to 10 μg/l with mean recovery rates of 87±3% and 60±1% for flumequine and 7-hydroxyflumequine, respectively.  相似文献   

12.
We measured Na+/K+ ATPase activity in homogenates of gill tissue prepared from field caught, winter and summer acclimatized yellow perch, Perca flavescens. Water temperatures were 2–4°C in winter and 19–22°C in summer. Na+/K+ ATPase activity was measured at 8, 17, 25, and 37°C. Vmax values for winter fish increased from 0.48±0.07 μmol P mg−1 protein h−1 at 8°C to 7.21±0.79 μmol P mg−1 protein h−1 at 37°C. In summer fish it ranged from 0.46±0.08 (8°C) to 3.86±0.50 (37°C) μmol P mg−1 protein h−1. The Km for ATP and for Na+ at 8°C was ≈1.6 and 10 mM, respectively and did not vary significantly with assay temperature in homogenates from summer fish. The activation energy for Na+/K+ ATPase from summer fish was 10 309 (μmol P mg−1 h−1) K−1. In winter fish, the Km for ATP and Na+ increased from 0.59±0.08 mM and 9.56±1.18 mM at 8°C to 1.49±0.11 and 17.88±2.64 mM at 17°C. The Km values for ATP and Na did not vary from 17 to 37°C. A single activation energy could not be calculated for Na/K ATPase from winter fish. The observed differences in enzyme activities and affinities could be due to seasonal changes in membrane lipids, differences in the amount of enzyme, or changes in isozyme expression.  相似文献   

13.
A rapid clean-up procedure based on ion-pair solid-phase extraction (SPE) for the high-performance liquid chromatographic (HPLC) determination of spectinomycin in swine, calf and chicken plasma at a limit of detection of 50 ng/ml is described. After dilution with water and adjustment of the pH to approximately 5.6, the plasma is applied to a high-hydrophobic C18 SPE column treated with sodium dioctylsulphosuccinate. Spectinomycin is eluted with methanol and derivatized with 2-naphthalene sulphonyl chloride prior to chromatography. The HPLC set-up consists of a dual-column system using two Chromspher silica columns and dichloromethane—acetonitrile—ethyl acetate—acetic acid, in different ratios, as mobile phases. Detection is performed at 250 nm. Quantification is carried out using external standards prepared in blank cleaned plasma. Mean recoveries were 83 ± 3% (n = 5), 93 ± 6% (n = 5) and 92 ± 6% (n = 6) for swine, calf and chicken plasma, respectively, at the 0.1 μg/ml level.  相似文献   

14.
A simple high-performance liquid chromatography (HPLC) assay for the simultaneous determination of guanase and aspartate aminotransferase (AST) activities in a single serum sample is described. The method is based on direct detection of enzymatically formed products xanthine and glutamate, respectively. The procedure is sensitive, precise (C.V. below 2% for guanase and 3% for AST), suitable for routine purposes and requires only 100 μl of sample. Kinetic measurements have shown the guanase activity to have an apparent Michaelis constant of 24.5 μM and the AST activity of 11.1 and 0.18 mM for aspartate and oxoglutarate, respectively, at 37°C in Tris-HCl buffer (pH 7.5).  相似文献   

15.
A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of the antifungal drug fluconazole in saliva and plasma of patients infected with the human immunodeficiency virus (HIV). Samples can be heated at 60°C for 30 min to inactivate the virus without loss of the analyte. The sample pretreatment involves a liquid-liquid extraction with chloroform-1-propanol (4:1, v/v). The chromatographic analysis is performed on a Lichrosorb RP-18 (5 μm) column by isocratic elution with a mobile phase of 0.01 M acetate buffer (pH 5.0)-methanol (70:30, v/v) and ultraviolet (UV) detection at 261 nm. The lower limit of is 100 ng/ml in plasma (using 500-μl samples) and 1 μg/ml in saliva (using 250-μl samples) and the method is linear up to 100 μg/ml in plasma and saliva. At a concentration of 5 μg/ml the within-day and between-day precision in plasma are 7.1 and 5.7%, respectively. In saliva the within-day and between-day precision is 10.8% (at 5 μg/ml). The methodology is now being used in pharmacokinetic studies in HIV-infected patients in our hospital.  相似文献   

16.
A method was developed for the determination in human urine of S-phenylmercapturic (PMA) and S-benzylmercapturic (BMA) acids, metabolites respectively of benzene and toluene. PMA and BMA were determined, after alkaline hydrolysis, to give respectively thiophenol and benzylmercaptan, and coupling of the thiol-containing compounds with monobromobimane (MB), by reversed-phase HPLC on a diphenyl-silica bonded cartridge (100×4.6 mm I.D., 5 μm particle size) with fluorimetric detection. Wavelengths for excitation and emission were 375 and 480 nm, respectively. The recovery of PMA and BMA from spiked urines was >90% in the 10–500 μg/l range; the quantification limits were respectively 1 and 0.5 μg/l; day-to-day precision at 42 μg/l was C.V. <7%. The suitability of the proposed procedure for the biological monitoring of exposure to low-level airborne concentrations of benzene and toluene, was evaluated by analyzing the urinary excretion of PMA and BMA in subjects exposed to different sources of aromatic hydrocarbons, namely occupationally-unexposed referents (non-smokers, n=15; moderate smokers, n=8; mean number of cigarettes smoked PER-DAY=17 cig/day) and non-smoker workers occupationally exposed to toluene in maintenance operations of rotogravure machines (non-smokers, n=17). Among referents, non-smokers showed values of PMA ranging from <1 to 4.6 μg/l and BMA from 1.0 to 10.4 μg/l; in smokers, PMA values ranging from 1.2 to 6.7 μg/l and BMA from 9.3 to 39.9 μg/l, were observed. In occupationally exposed non-smoker subjects, BMA median excretion value (23.6 μg/l) was higher than in non-smoker referents (3.5 μg/l) (P<0.001) and individual BMA values (y, μg/l) were associated and increased with airborne toluene concentration (x, mg/m3) according to the equation y=6.5+0.65x (r=0.69, P<0.01, n=17). The proposed analytical method appears to be a sensitive and specific tool for biological monitoring of low-level exposure to benzene and toluene mixtures in occupational and environmental toxicology laboratory.  相似文献   

17.
trans,trans-Muconic acid (1,3-butadiene-1,4-dicarboxylic acid, MA), a minor urinary metabolite of benzene exposure, was determined, after clean-up by solid-phase anion-exchange chromatography, by reversed-phase HPLC on a C18 column (5 × 0.46 cm I.D., 3 μm particle size), using formic acid-tetrahydrofuran-water (14:17:969) as mobile phase and UV detection at 263 nm. The recovery of MA from spiked urine was > 95% in the 50–500 μg/l range; the quantification limit was 6 μg/l; day-to-day precision, at 300 μg/l, C.V. = 9.2%; the run time was less than 10 min. Urinary MA excretion was measured in two spot urine samples of 131 benzene environmentally exposed subjects: midday values obtained in non-smokers (mean±S.D.=77±54 μg/l, N = 82) were statistically different from those of smoerks (169±85 μg/l, N = 30) (P<0.0001); each group showed a statistically significant increase between MA excretion in midday over morning samples. Moreover, in subjects grouped according to tobacco-smoke exposure level, median values of MA were positively associated with and increased with daily smoking habits.  相似文献   

18.
A simple and reliable HPLC method for quantitative determination of pseudouridine and uric acid in human urine and serum using a cation-exchange resin is described. This method is straightforward (12 runs of urine samples per day since the sample is only diluted into buffer and then chromatographed), sensitive, and highly reproducible. The column is stable over long periods (3 months of uninterrupted use at a time; it is thereafter easily restored to the original state). Mean excretion values for pseudouridine (in μmol/mmol creatinine) are 26.4 ± 3.1 (17 female adults), 23.8 ± 2.5 (12 male adults), 164.7 ± 32.2 (37 male preterm infants); mean values for uric acid (μmol/mmol creatinine) are, respectively, 310.3 ± 90.5, 278.2 ± 56.1, and 1108 ± 314. Human serum is deproteinized by pressure ultrafiltration in microcollodion bags with a nominal exclusion molecular weight of 12,400 and then put directly onto the HPLC column. The complete procedure takes 4 h.  相似文献   

19.
A high-performance liquid chromatographic (HPLC) procedure for lamotrigine was developed and validated. Lamotrigine (LTG) and an internal standard were extracted from plasma using liquid–liquid extraction under alkaline conditions into an organic solvent. The method was linear in the range 0.78–46.95 μmol/l, with a mean coefficient of correlation (r)≥0.99923. The limit of detection (LOD) and limit of quantification (LOQ) were 0.19 and 0.58 μmol/l, respectively. Within- and between-run precision studies demonstrated C.V.<3% at all tested concentrations. LTG median recovery was 86.14%. Antiepileptic drugs tested did not interfere with the assay. The method showed to be appropriate for monitoring LTG in plasma samples.  相似文献   

20.
A highly sensitive HPLC method for the determination of prolyl dipeptides, Pro and Hyp in serum was developed. After deproteinization of serum and pretreatment with o-phthalaldehyde, the analytes were derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride at 70°C for 10 min. The fluorescent derivatives of prolyl dipeptides, Pro and Hyp, were separated on tandem reversed-phase columns by a gradient elution at 55°C and detected by fluorescence measured at 318 nm (excitation) and 392 nm (emission). The detection limits for prolyl dipeptides were 2–5 fmol/injection (S/N=3). Pro–Hyp, Pro–Gly and Pro–Pro were identified as serum prolyl dipeptides. The within-day and between-day relative standard deviations were 1.5–7.9 and 2.4–10.8%, respectively. The recoveries were in the range of 90.8–97.3%. The concentrations of Pro–Hyp, Pro–Gly, Pro–Pro, Pro and Hyp in normal human serum (n=10) were 0.64±0.35, 0.078±0.047, 0.022±0.016, 177.0±43.0 and 11.1±3.5 μM, respectively. The concentrations of Pro–Hyp and Pro–Pro in serum of a patient with bone metastases of prostatic cancer were about three times and 50 times, respectively, higher than those in normal human serum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号