首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND: Rapid-mix flow cytometry has emerged as a powerful tool for mechanistic analysis of ligand binding, cell response, and molecular assembly. Although progress has come from improving sample delivery capabilities, little attention has been paid to the volumetric requirements associated with precious biological reagents. METHODS: By using programmable syringes, valves, and other fluidic components, we created a modular, precisely regulated rapid-mix device for the delivery of small-volume samples to the flow cytometer. The device was tested using a bead-based assay in which the binding kinetics between native biotin and fluorescein biotin-bearing beads were characterized. RESULTS: Bead suspensions and reagents paired in 35- to 45-microl aliquots were efficiently mixed by the device and delivered to the flow cytometer. Kinetic data associated with the fluorescein biotin beads were analyzed and used to calibrate the performance characteristics of the device in terms of sample delivery and mixing efficiency. CONCLUSION: The rapid-mix device is capable of detecting subsecond kinetics of biological reactions using microliter volume of samples. Dimensions of the device have been minimized, and the quantitative aspects of sample delivery and analysis have been optimized. Further, the modular design has been optimized for adaptation to a variety of experimental protocols.  相似文献   

2.
We describe a simple and inexpensive device which permits the addition of up to three different solutions into a cell suspension which is on-line in a flow cytometer. The mixing chamber houses a disposable plastic cuvette stirred with a magnetic stirrer. The sample chamber is attached to a circulating water bath, hence accurate temperature control is achieved. Because the system is prepressurized and the sample line is very short, the delay time-between the point of sample modification and the point of analysis is reduced to a few seconds. Thus reagents may be added rapidly, and kinetic measurements of high temporal resolution are possible. Because the temperature of the sample chamber is regulated, binding can be observed over longer time periods than was previously possible. We demonstrate the usefulness of this device in determining the binding of fluoresceinated hexapeptide to human neutrophils under conditions where the stimulus is infused into the cell suspension while on-line in the cytometer.  相似文献   

3.
Cell complexes composed of two different cells labeled with different fluorophores can be detected as double positive events in the flow cytometer. Double positivity can originate not only from real complexes but from non-interacting coinciding cells as well. Coincidence has a high impact on the determination of the amount of platelet–granulocyte complexes since platelet concentration is in the orders of magnitude higher than that of the granulocytes. Mixtures of non-interacting fluorescent beads as well as EDTA anticoagulated or citrated blood samples were analyzed in the flow cytometer in the presence and absence of fluorescent beads at various dilutions. Experimental data were evaluated by mathematical means. The bead or platelet concentration dependence of double positivity was converted into linear functions using Poisson distribution. This linearised form contains information on the detection volume as well as on the presence/absence of dilution independent complexes. The presence of appropriate fluorescent beads in the blood sample makes possible to estimate the fraction of double positivity originating from coincidence if data collection is triggered by the granulocytes or by the fluorescent beads, alternatively. Mixing fluorescent beads into a blood sample is a simple experimental method to distinguish double positivity originating from real cell–cell complexes from the coincidence of cells in a flow cytometer, thus providing a tool for the determination of the real amount of cell–cell complexes.  相似文献   

4.
BACKGROUND: Plug flow cytometry is a recently developed system for the automated delivery of multiple small boluses or "plugs" of cells or particles to the flow cytometer for analysis. Important system features are that sample plugs are of precisely defined volume and that the sample vessel need not be pressurized. We describe how these features enable direct cell concentration determinations and novel ways to integrate flow cytometers with other analytical instruments. METHODS: Adhesion assays employed human polymorphonuclear neutrophils (PMNs) loaded with Fura Red and Chinese hamster ovary (CHO) cells cotransfected with genes for green fluorescent protein (GFP) and human P-selectin. U937 cells expressing the human 7-transmembrane formyl peptide receptor were loaded with the fluorescent probe indo-1 for intracellular ionized calcium determinations. A computer-controlled syringe or peristaltic pump loaded the sample into a sample loop of the plug flow coupler, a reciprocating eight-port valve. When the valve position was switched, the plug of sample in the sample loop was transported to the flow cytometer by a pressure-driven fluid line. RESULTS: In stirred mixtures of PMNs and CHO cells, we used plug flow cytometry to directly quantify changes in concentrations of nonadherent singlet PMNs. This approach enabled accurate quantification of adherent PMNs in multicell aggregates. We constructed a novel plug flow interface between the flow cytometer and a cone-plate viscometer to enable real-time flow cytometric analysis of cell-cell adhesion under conditions of uniform shear. The High Throughput Pharmacology System (HTPS) is an instrument used for automated programming of complex pharmacological cell treatment protocols. It was interfaced via the plug flow coupling device to enable rapid (< 5 min) flow cytometric characterization of the intracellular calcium dose-response profile of U937 cells to formyl peptide. CONCLUSIONS: By facilitating the coupling of flow cytometers to other fluidics-based analytical instruments, plug flow cytometry has extended analytical capabilities in cell adhesion and pharmacological characterization of receptor-ligand interactions.  相似文献   

5.
This report describes the application and installation of a barcode reader on a standard EPICS Elite flow cytometer. The barcode reader system eliminates keyboard entry of sample information on the cytometer. The system automates the transfer of sample information already present in our laboratory database to the cytometer at run time. The system uses a standard "off-the-shelf" bar code wand with a personal computer keyboard interface and requires no additional software at run time. No typing of sample information is required by the operator at any stage of normal sample operation at the cytometer. All operations are automatically coded into the cytometry software using the macro functions of the software. Tubes are inserted into the tube reader and sample information is transferred automatically into the cytometer. We have found that the system allows rapid and continuous operation of routine clinical and research samples. This automated data entry also reduces the possibility of data input errors.  相似文献   

6.
The use of an automated image cytometer for screeing and quantitative assessment of cervical lesions in the British Columbia Cervical Smear Screening Programme
The development of an automated device to screen cervical cytology slides for the detection of pre-invasive lesions of the cervix has been the goal of many individuals for over 30 years. The increasing sophistication of the technology of automation and increasingly powerful computer technology have enabled a number of these systems to reach the stage at which they have become a practical reality. The Department of Cancer Imaging at the British Columbia Cancer Agency has developed such a device over the past few years. This study reports the preliminary results of a trial to determine the reliability of the device for the screening and quantitative assessment of cervical cells. A training set of over 1000 cervical slides was used to train the image cytometer. A test set of 1030 slides was screened by the image cytometer and in the Cytology Screening Laboratory. At the 50% sample split the sensitivity of the image cytometer was 95% for severe dysplasia and 90% for moderate dysplasia, compared with a sensitivity of 90% for both of these lesions using conventional screening. A combination of nuclear texture features was found which can be used for the quantitative assessment of both abnormal cells and apparently normal intermediate cells.  相似文献   

7.
Traditionally, many cell-based assays that analyze cell populations and functionalities have been performed using flow cytometry. However, flow cytometers remain relatively expensive and require highly trained operators for routine maintenance and data analysis. Recently, an image cytometry system has been developed by Nexcelom Bioscience (Lawrence, MA, USA) for automated cell concentration and viability measurement using bright-field and fluorescent imaging methods. Image cytometry is analogous to flow cytometry in that gating operations can be performed on the cell population based on size and fluorescent intensity. In addition, the image cytometer is capable of capturing bright-field and fluorescent images, allowing for the measurement of cellular size and fluorescence intensity data. In this study, we labeled a population of cells with an enzymatic vitality stain (calcein-AM) and a cell viability dye (propidium iodide) and compared the data generated by flow and image cytometry. We report that measuring vitality and viability using the image cytometer is as effective as flow cytometric assays and allows for visual confirmation of the sample to exclude cellular debris. Image cytometry offers a direct method for performing fluorescent cell-based assays but also may be used as a complementary tool to flow cytometers for aiding the analysis of more complex samples.  相似文献   

8.
BACKGROUND: The tools for high throughput flow cytometry have been limited in part because of the requirement that the samples must flow under pressure. We describe a simple system for sampling repetitively from an open vessel. METHODS: Under computer control, the sample is loaded into a sample loop in a reciprocating eight-way valve by the action of a syringe. When the valve position is switched, the plug of sample in the sample loop is transported to the flow cytometer by a pressure-driven fluid line. By coupling the plug-forming capability to a second multi-port valve, samples can be delivered sequentially from separate vessels. RESULTS: The valve is able to deliver samples at rates ranging up to about 9 samples per minute. Each plug of sample has uniform delivery characteristics with a reproducible coefficient of variation (CV). Even at the highest sampling rate, carryover between samples is limited. CONCLUSIONS: Plug-flow flow cytometry has the potential to automate the delivery of small samples from unpressurized sources at rates compatible with many screening and assay applications.  相似文献   

9.
BACKGROUND: The development of inexpensive small flow cytometers is recognized as an important goal for many applications ranging from medical uses in developing countries for disease diagnosis to use as an analytical platform in support of homeland defense. Although hydrodynamic focusing is highly effective at particle positioning, the use of sheath fluid increases assay cost and reduces instrument utility for field and autonomous remote operations. METHODS: This work presents the creation of a novel flow cell that uses ultrasonic acoustic energy to focus small particles to the center of a flowing stream for analysis by flow cytometry. Experiments using this flow cell are described wherein its efficacy is evaluated under flow cytometric conditions with fluorescent microspheres. RESULTS: Preliminary laboratory experiments demonstrate acoustic focusing of flowing 10-microm latex particles into a tight sample stream that is approximately 40 microm in diameter. Prototype flow cytometer measurements using an acoustic-focusing flow chamber demonstrated focusing of a microsphere sample to a central stream approximately 40 microm in diameter, yielding a definite fluorescence peak for the microspheres as compared with a broad distribution for unfocused microspheres. CONCLUSIONS: The flow cell developed here uses acoustic focusing, which inherently concentrates the sample particles to the center of the sample stream. This method could eliminate the need for sheath fluid, and will enable increased interrogation times for enhanced sensitivity, while maintaining high particle-analysis rates. The concentration effect will also enable the analysis of extremely dilute samples on the order of several particles per liter, at analysis rates of a few particles per second. Such features offer the possibility of a truly versatile low-cost portable flow cytometer for field applications.  相似文献   

10.
Sample flow switching techniques on microfluidic chips   总被引:1,自引:0,他引:1  
This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.  相似文献   

11.
Kim HS  Son OT  Kim KH  Kim SH  Maeng S  Jung HI 《Biotechnology letters》2007,29(11):1659-1663
A highly sensitive microfluidic device has been developed to separate apoptotic cells. Apoptotic Jurkat cells were selectively labeled with magnetic beads (0.8 μm diam) using the C2A protein which recognizes phosphatidylserine. The cell mixture was flowed through a microfluidic channel and apoptotic cells were separated by a 0.3 T permanent magnet. Separations using our device showed 96% agreement with those of a commercial flow cytometer, indicating our device can be used to sort apoptotic cells in a miniaturized system.  相似文献   

12.
We have constructed a simple device by which the optimal delay time between optical measurement of a cell and the application of the droplet charging pulse can be determined directly in a flow sorter. The device consists of a stainless steel chamber in which the sorted droplets are collected. In the collection chamber the collected droplets run through a capillary where a continuous fluorescence measurement is made. With a sample of fluorescent particles, the delay time is optimal when the measured fluorescence is maximal. The measuring volume is always filled with the last droplets sorted (about 3,000). With this device, the setting of the delay time can be done in a few seconds without the need for microscopical verification. The fluorescence in the collection chamber is excited and detected via optical fibers using about 10% of the light of the existing laser from the flow cytometer and an extra photomultiplier.  相似文献   

13.
In recent years, the rapid analysis of single cells has commonly been performed using flow cytometry and fluorescently-labeled antibodies. However, the issue of spectral overlap of fluorophore emissions has limited the number of simultaneous probes. In contrast, the new CyTOF mass cytometer by DVS Sciences couples a liquid single-cell introduction system to an ICP-MS.1 Rather than fluorophores, chelating polymers containing highly-enriched metal isotopes are coupled to antibodies or other specific probes.2-5 Because of the metal purity and mass resolution of the mass cytometer, there is no "spectral overlap" from neighboring isotopes, and therefore no need for compensation matrices. Additionally, due to the use of lanthanide metals, there is no biological background and therefore no equivalent of autofluorescence. With a mass window spanning atomic mass 103-203, theoretically up to 100 labels could be distinguished simultaneously. Currently, more than 35 channels are available using the chelating reagents available from DVS Sciences, allowing unprecedented dissection of the immunological profile of samples.6-7Disadvantages to mass cytometry include the strict requirement for a separate metal isotope per probe (no equivalent of forward or side scatter), and the fact that it is a destructive technique (no possibility of sorting recovery). The current configuration of the mass cytometer also has a cell transmission rate of only ~25%, thus requiring a higher input number of cells.Optimal daily performance of the mass cytometer requires several steps. The basic goal of the optimization is to maximize the measured signal intensity of the desired metal isotopes (M) while minimizing the formation of oxides (M+16) that will decrease the M signal intensity and interfere with any desired signal at M+16. The first step is to warm up the machine so a hot, stable ICP plasma has been established. Second, the settings for current and make-up gas flow rate must be optimized on a daily basis. During sample collection, the maximum cell event rate is limited by detector efficiency and processing speed to 1000 cells/sec. However, depending on the sample quality, a slower cell event rate (300-500 cells/sec) is usually desirable to allow better resolution between cells events and thus maximize intact singlets over doublets and debris. Finally, adequate cleaning of the machine at the end of the day helps minimize background signal due to free metal.  相似文献   

14.
A new fluid switching flow sorter   总被引:1,自引:0,他引:1  
Conventional cell sorters produce potentially hazardous microdroplets containing dyes and radiolabeled compounds commonly used to identify and trace subpopulations of cells. Many of these substances are potential toxins, mutagens, or carcinogens constituting a risk to personal associated with the sorting device. The separation of living cells for continued study of cell growth from an "in air" sample stream includes the risk of contamination with microorganisms altering the following cultures. To avoid those risks, we have constructed a new capsular flow cytometer sorter which consists of a small chamber completely encasing the sorting mechanism. Data acquisition, analysis, and processing are accomplished by using a microcomputer-based pulse height analyser.  相似文献   

15.
Capillary blood sampling has been identified as a potentially suitable technique for use in diagnostic testing of the full blood count (FBC) at the point-of-care (POC), for which a recent need has been highlighted. In this study we assess the accuracy of capillary blood counts and evaluate the potential of a miniaturized cytometer developed for POC testing. Differential leukocyte counts in the normal clinical range from fingerprick (capillary) and venous blood samples were measured and compared using a standard hematology analyzer. The accuracy of our novel microfluidic impedance cytometer (MIC) was then tested by comparing same-site measurements to those obtained with the standard analyzer. The concordance between measurements of fingerprick and venous blood samples using the standard hematology analyzer was high, with no clinically relevant differences observed between the mean differential leukocyte counts. Concordance data between the MIC and the standard analyzer on same-site measurements presented significantly lower leukocyte counts determined by the MIC. This systematic undercount was consistent across the measured (normal) concentration range, suggesting that an internal correction factor could be applied. Differential leukocyte counts obtained from fingerprick samples accurately reflect those from venous blood, which confirms the potential of capillary blood sampling for POC testing of the FBC. Furthermore, the MIC device demonstrated here presents a realistic technology for the future development of FBC and related tests for use at the site of patient care.  相似文献   

16.
We propose a method which significantly shortens the time required for both the collection and analysis of data derived from multiple sample, flow cytometric kinetic assays. We have defined the term Time Interval Gating (TIG) to describe this method. TIG effectively allows one flow cytometer to concurrently monitor several samples over the course of a kinetic assay. Data for all samples are stored in a single FCS 2.0 compatible listmode data file which we refer to as the TIG data file. TIG is adaptable to most commerical flow cytometers. Standard listmode analysis software can be used to analyze the TIG data files and correlate any combination of tubes and/or time intervals from the assay. Results for the entire assay can be displayed on a single two parameter plot. This paper describes how TIG is applied to neutrophil oxidative burst measurement using a standard EPICS Elite flow cytometer. In this assay, 11 samples were each monitored for 30 min to identify the extent to which volatile organic chemicals (VOCs) inhibited the oxidation of DCFH in stimulated neutrophils. TIG makes the oxidative burst assay practical for high volume screening by reducing the overall flow cytometer and analysis time required by a factor of ten. In addition, TIG provides an organized approach to managing data acquisition on instruments equipped with automated sampling systems.  相似文献   

17.
Routine monitoring of Cryptosporidium oocysts in water using flow cytometry   总被引:10,自引:2,他引:8  
A flow cytometric method for the routine analysis of environmental water samples for the presence of Cryptosporidium oocysts has been developed. It uses a Coulter Epics Elite flow cytometer to examine water samples and to separate oocysts from contaminating debris by cell sorting. The sorted particles are then rapidly screened by microscopy. The method has been evaluated and compared with direct epifluorescence microscopy on 325 river, reservoir and drinking water samples. The technique was found to be more sensitive, faster and easier to perform than conventional epifluorescent microscopy for the routine examination of water samples for Cryptosporidium.  相似文献   

18.
Satoh K  Yatomi Y  Kubota F  Ozaki Y 《Cytometry》2002,48(4):194-201
BACKGROUND: Although cross-talks between platelets and other blood cells are important in vivo, laboratory platelet aggregation tests have been performed mainly with the use of platelet-rich plasma (PRP) as samples. Methods that enable an efficient and sensitive detection of platelet aggregates in whole blood are being developed. METHODS: A flow cytometer equipped with an imaging device, the flow imaging cytometer 2 (FIC2), was used to detect platelet aggregates in whole blood. RESULTS: The FIC2 provides a resolution that is high enough to differentiate platelet aggregates from single platelets or other blood cells. Epinephrine elicited platelet aggregate formation in hirudin plus argatroban-treated whole blood, but not in PRP. The reconstitution study revealed that a small amount of adenosine diphosphate (ADP) from erythrocytes may play an important role in epinephrine-induced platelet aggregation (in whole blood), through mediation of P2Y1 receptors. When the inhibitory effect of beraprost, an antiplatelet agent, on platelet aggregation was assessed, analysis of whole blood samples with FIC2 proved to be the most sensitive among the methods available. CONCLUSIONS: FIC2 is a promising device for detection of platelet aggregates in whole blood, with wide basic and clinical applications.  相似文献   

19.
Steen HB 《Cytometry》2002,49(2):70-72
BACKGROUND: The sample injection systems of flow cytometers employ either a pressure differential between the sample vial and the sheath fluid reservoir or volumetric injection of the sample from a syringe. The pressure differential method facilitates rapid and efficient flushing to eliminate carryover between samples, but does not allow accurate determination of the rate of sample flow and cell concentration. Volumetric injection, which comprises a valve for switching the sample flow, facilitates highly accurate measurement of the cell concentration, but requires a less efficient and more time-consuming flushing procedure. METHODS: Applying a removable syringe, which connects to the inlet of the sample tubing via a tight sealing, we eliminate the valve and obtain efficient flushing while maintaining the advantage of volumetric sample injection. RESULTS: This device gives highly constant sample flow rates strictly proportional to syringe velocity over the range 0.2-50 microl/min with a settling time of about 2 sec. CONCLUSION: This device has the same precision as the conventional sample injection system, whereas the speed and efficiency of flushing are improved greatly.  相似文献   

20.
流式细胞术是一种采用激光束激发单行流动的细胞,对它的散射光和携带的荧光进行探测,从而完成细胞分析和分选的技术。以流式细胞术为核心技术,流式细胞仪集光学、电子学、生物学、免疫学等多门学科和技术于一体,能够高效分析微小颗粒(如细胞,细菌)的先进科技设备。它对社会产生了深远的影响,成为了科学研究的必要工具。最近几年,流式细胞仪取得了长足进步。为了深入的了解它,本文从流式细胞仪的工作原理和技术指标,在临床医学、生物学、生殖学和制药学中的应用,以及它的世界格局、仪器功能的最新进展三方面,进行了简明、扼要的论述。展望未来:功能专业化、自动化,体积小型化,多色多参数分析能力提高和分析分选速度更快成为流式细胞仪发展的趋势。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号