首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The combination of capillary electrophoresis (CE) and mass spectrometry (MS) with solid-phase extraction (SPE) has been used for the identification of nicotine and eight of its metabolites in urine. The recovery of cotinine from cotinine-spiked urine, by C18 SPE, was found to be 98%. Smokers urine (200 ml) was preconcentrated 200-fold via SPE prior to analysis. The sample stacking mode of CE, when compared to capillary zone electrophoresis, was shown to improve peak efficiency by 132-fold. The combination of hydrodynamic and electrokinetic injection was studied with sample stacking/CE/MS. The on-column limits of detection (LOD) of nicotine and cotinine, by this technique, were found to be 0.11 and 2.25 microg/ml, respectively. Hence, LODs of nicotine and cotinine in urine after 200-fold preconcentration were 0.55 and 11.25 ng/ml, respectively.  相似文献   

2.
Capillary electrophoresis (CE) has become a useful analytical tool for the analysis of microdialysis samples. However, CE with UV detection (CE-UV) does not provide detection limits sufficient to quantify glutathione (GSH) and glutathione disulfide (GSSG) in biological samples such as liver microdialysates, because of the small optical path length in the capillary. To overcome this limitation, an on-column preconcentration technique, pH-mediated base stacking, was used in this study to improve the sensitivity of CE-UV. This stacking technique allowed large volumes of high ionic strength sample injection without deterioration of the separation efficiency and resolution. A 26-fold increase in sensitivity was achieved for both GSH and GSSG using the pH-mediated base stacking, relative to normal injection without stacking. The limit of detection for GSH and GSSG was found to be 0.75 microM (S/N=6) and 0.25 microM (S/N=6), respectively. The developed method was used to analyze GSH and GSSG in liver microdialysates of anesthetized Sprague Dawley male rats. The basal concentrations of GSH and GSSG in the liver microdialysates of male rats were found to be 4.73+/-2.08 microM (n=7) and 5.52+/-3.66 microM (n=7), respectively.  相似文献   

3.
A sensitive analytical method for gabapentin [1-(aminomethyl) cyclohexaneacetic acid] (GBP) in human plasma based on capillary electrophoretic separation and laser-induced fluorescence (LIF) detection has been developed. 6-Carboxyfluorescein succinimidyl ester (CFSE) was used for precolumn derivatization of the non-fluorescent drug in plasma. Optimal separation and detection were obtained with an electrophoretic buffer of 50mM sodium borate (pH 9.5) and an air-cooled argon-ion laser (excitation at 488 nm, emission at 520 nm). A calibration curve ranging from 0.3 to 150 microM was shown to be linear. The concentration limit of detection (LOD) in plasma was 60 nM. We also demonstrate how the detection limit can be enhanced by using acetonitrile stacking technique. With stacking, the limit of detection for gabapentin in plasma was 4.8 nM. A calibration curve ranging from 0.03 to 15 microM was shown to be linear. Both the within-day and day-to-day reproducibility and accuracy were 相似文献   

4.
In this paper, we describe a method for analyzing large-volume protein samples using capillary electrophoresis in conjunction with laser-induced fluorescence detection (CE-LIF). To improve the stacking and separation efficiencies of proteins, we added either 0.01% sodium dodecyl sulfate (SDS) or 0.01% poly(ethylene oxide) (PEO) to the Tris-borate solutions (pH 10.0) used to prepare the protein samples. After injection of the large-volume samples (ca. 1.0 microL, 0.1 microM), the proteins migrate against the electroosmotic flow (EOF) and enter the PEO zone; this process causes them to slow and stack at the boundary between the PEO and sample zones. As a result, the limits of detection (LODs) at a signal-to-noise (S/N) of 3 for most proteins are sub-nM to several nM. For instance, the LOD (S/N = 3) for alpha-lactalbumin is 0.48 nM, which is an 84-fold sensitivity enhancement over the traditional method. By applying a short plug of 0.2% SDS prior to sample injection, a greater number of peaks, representing the microheterogeneity of the proteins, were resolved and the stacking efficiency of the proteins increased slightly. This method allowed us to detect 12 peaks when injecting a large volume of sample containing six model proteins (0.1 microM). We also analyzed the microheterogeneities of the proteins by using CE with UV-Vis absorption detection when injecting a large volume of sample containing six model proteins (1.0 microM) in the presence of a 1.0% SDS plug. The practical method is validated by the detection of human serum albumin in a urine sample, obtained from a healthy female, without sample pretreatment; its concentration was 0.18 microM. We further demonstrate the capability of this method to detect low amounts of proteins through the detection of 45 nM hemoglobin after injecting ca. 1.0 microL of ultradilute lysed red blood cells. The experimental results indicate that our proposed method has great potential for use in diagnosis and proteomics applications.  相似文献   

5.
In this article, an antibiotic, lincomycin was determined in the urine sample by microchip capillary electrophoresis (CE) with integrated indium tin oxide (ITO) working electrode based on electrochemiluminescence (ECL) detection. This microchip CE-ECL system can be used for the rapid analysis of lincomycin within 40s. Under the optimized conditions, the linear range was obtained from 5 to 100 microM with correlation coefficient of 0.998. The limit of detection (LOD) of 3.1 microM was obtained for lincomycin in the standard solution. We also applied this method to analyzing lincomycin in the urine matrix. The limit of detection of 9.0 microM was obtained. This method can determine lincomycin in the urine sample without pretreatment, which demonstrated that it is a promising method of detection of lincomycin in clinical and pharmaceutical area.  相似文献   

6.
Large-volume sample stacking capillary electrophoresis (LVSS-CE) and conventional capillary electrophoresis (CE) are compared for the separation of drugs of significance to forensic and clinical analyses. LVSS-CE for cations requires the use of an electroosmotic flow (EOF) modifier in conjunction with polarity switching to effect on-column concentration of an analyte and its subsequent migration in the capillary. The run buffer consists of 0.05 mol dm−3 disodium tetraborate adjusted to pH 2.2 with orthophosphoric acid, and the EOF modifier is 0.002 mol dm−3 cetyltrimethylammonium bromide. CE investigations used an identical run buffer minus the EOF modifier. LVSS-CE and CE investigations used injection times of 30 s and 3 s, respectively. Both modes of capillary electrophoresis are compared in terms of their limits of detection, efficiency, resolution and reproducibility. LVSS-CE is also applied to the analysis of a spiked urine sample.  相似文献   

7.
Fast and efficient analysis of proteins in physiological fluids is of great interest to researchers and clinicians alike. Capillary electrophoresis (CE) has proven to be a potentially valuable tool for the separation of proteins in specimens. However, a generally acknowledged drawback of this technique is the limited sample volumes which can be loaded onto the CE capillary which results in a poor concentration limit of detection. In addition, matrix components in samples may also interfere with separation and detection of analytes. Membrane preconcentration–CE (mPC–CE) has proved to be effective in overcoming these problems. In this report, we describe the systematic evaluation of parameters affecting on-line preconcentration/clean-up and separation of protein mixtures by mPC–CE. Method development was carried out with a standard mixture of proteins (lysozyme, myoglobin, carbonic anhydrase, and human serum albumin). First, using MALDI-TOF-MS, membrane materials with cation-exchange (R-SO3H) or hydrophobic (C2, C8, C18, SDB) characteristics were evaluated for their potential to retain proteins in mPC cartridges. Hydrophobic membranes were found most suitable for this application. Next, all mPC–CE analysis of protein samples were performed in polybrene coated capillaries and parameters affecting sample loading, washing and elution, such as the composition and volume of the elution solvent were investigated. Furthermore, to achieve optimal mPC–CE performance for the separation of protein mixtures parameters affecting postelution focusing and electrophoresis, including the composition of the background electrolyte and a trailing stacking buffer were varied. Optimal conditions for mPC–CE analysis of proteins using a C2 impregnated membrane preconcentration (mPC) cartridge were achieved with a background electrolyte of 5% acetic acid and 2 mM ammonium acetate, 60 nl of 80% acetonitrile in H2O as an elution solvent, and 60 nl of 0.5% ammonium hydroxide as a trailing stacking buffer. The developed method was used successfully to separate proteins in aqueous humor, which contains numerous proteins in a complex matrix of salts.  相似文献   

8.
An on-column isotachophoretic (ITP)-capillary electrophoresis (CE) system capable of preconcentrating polyhydroxyl species is reported. The ITP-CE system utilizes borate complexation of the neutral diol species to form anionic compounds that can be directly separated by CE. Borate buffer fuctions as both the terminating electrolyte for the ITP preconcentration and the operating buffer for the subsequent CE separation. Isotachophoretic preconcentration allows injection volumes as large as 50% of the column volume, without compromising separation integrity, to yield detection limits about 70-fold lower than direct CE separation (with borate operating buffer). In this paper we also present an application of the ITP-CE system, with laser-induced fluorescence (LIF) detection, to the quantitative analysis of adenosine from urine. Nanomolar concentration levels of adenosine are successfully derivatized with chloroacetaldehyde (CAA) to form a fluorescent derivative whose spectral characteristics match the HeCd laser. The technique is shown to be capable of quantitative measurement of adenosine as low as 10−9 M, the levels expected in plasma and urine.  相似文献   

9.
A capillary electrophoretic (CE) method with contactless conductivity detection (CCD) has been developed for the determination of free amino acids (AAs) in the amniotic fluid. Apart from 20 proteinogenic AAs, 12 other biogenic compounds have been identified including ethanolamine, choline, beta-alanine, 2-aminobutyric acid, 4-aminobutyric acid, creatinine, ornithine, carnitine, citrulline, 4-hydroxyproline, 1-methylhistidine and 3-methylhistidine. The running electrolyte consisted of 1.7 M acetic acid and 0.1% hydroxyethyl-cellulose (pH 2.15). An addition of acetonitrile to the sample improved the separation of AAs significantly and permitted an increase in the amount of the sample injected. As a result, the sensitivity of the determination increased and the limit of detection (LOD) decreased by a factor of ca. 4, as compared with our previous study. The LOD values were between 1.5 microM (arginine) and 6.7 microM (aspartic acid). The CE/CCD method has then been applied to clinical analyses of the amniotic fluid collected from 20 pregnant women aged over 35 years and 24 pregnant women with whom abnormal foetus development was suspected. The latter group of women was found to exhibit systematically enhanced amniotic levels of most of the AAs studied.  相似文献   

10.
Powerful capillary electrophoresis (CE) methods were developed for monitoring the reaction of ecto-5'-nucleotidase (ecto-5'-NT, CD73), a (patho)biochemically important enzyme that hydrolyzes nucleoside-5'-monophosphates to the corresponding nucleosides. The enzymatic reaction was performed either before injection into the capillary (method A) or directly within the capillary (method B). In method A, separation of substrates and products was achieved within 8 min using an eCAP fused-silica capillary (20 cm effective length, 75 microM i.d., UV detection at 260 nm), 40 mM sodium borate buffer (pH 9.1), normal polarity, and a constant voltage of 15 kV. In method B, the sandwich technique was applied; substrate dissolved in reaction buffer (10mM Hepes [pH 7.4], 2mM MgCl2, and 1mM CaCl2) was hydrodynamically injected into a fused-silica capillary (30 cm, 75 microM i.d.), followed by enzyme (recombinant rat ecto-5'-NT) and subsequent injection of substrate solution. The reaction was initiated by the application of 1 kV voltage for 1 min. The voltage was turned off for 1 min and again turned on at a constant voltage of 15 kV to elute products (nucleosides) within 4 min using borate buffer (40 mM, pH 9.1). Thus, assays could be performed within 6 min, including enzymatic reaction, separation, and quantification of the formed nucleoside. The CE methods were used for measuring enzyme kinetics and for assaying inhibitors and substrates. In addition, the online assay was successfully applied to melanoma cell membrane preparations natively expressing the human ecto-5'-NT.  相似文献   

11.
Method for a direct determination of 8-hydroxy-2'-deoxyguanosine (8OHdG) in untreated urine samples by capillary electrophoresis with optical detection was developed. Optimisation of conditions resulted in a significant lowering of the limit of detection (LOD) by a factor of 400 as compared to our previous study. Optimum separation of 8OHdG from other urine components was achieved using the separation electrolyte containing 80 mM 2-(cyclohexylamino)ethanesulfonic acid, 9 mM LiOH (pH 8.6), and 0.1 mM cetyltrimethylammonium bromide ensuring the electro-osmotic flow inversion. In the model aqueous samples, these conditions allow separating 8OHdG and 2'-deoxyguanosine (dG) from other nucleosides/nucleotides including 2'-deoxycitidine 5'-monophosphate (dCMP), thymidine 5'-monophosphate (TMP), adenosine (A), and thymidine (T). On the other hand, 2'-deoxyadenosine 5'-monophosphate (dAMP) and 2'-deoxyguanosine 5'-monophosphate (dGMP) migrate together, and guanosine (G), 2'-deoxyadenosine (dA), 2'-deoxycytidine (dC) are transported as neutral species with the electro-osmotic flow. In the spiked urine samples, 8OHdG and dG are well separated from each other and from other urine components and exhibit a linear calibration over the concentration range of 0.1-2.0 microM for 8OHdG (LOD = 42 nM) and 0.2-5.0 microM for dG (LOD = 86 nM), but urine metabolites interfere with the determination of dCMP, TMP, A and T. Method is applicable to untreated urine samples with slightly enhanced levels of 8OHdG compared to that found in healthy individuals.  相似文献   

12.
Heng Liang  Jing Xue  Tian Li  Yayan Wu 《Luminescence》2005,20(4-5):287-291
A novel simultaneous determination method for free and total proline (Pro) and hydroxyproline (Hyp) in human urine was developed, based on capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection, using tris-(2,2'-bipyridyl) ruthenium(II). Experimental conditions, such as the Ru(bpy)(3)2+ concentration, detection potentials, buffer concentration and pH in CE or in the ECL cell, injection voltage and time were investigated in detail. Under optimized conditions, the linear range, detection limit and sample recoveries for the method were 0.01-2 mmol/L (correlation coefficient, 0.9970), 4 micromol/L and 96.4-101.2% in human urine, respectively. The results show that the method has potential applications in monitoring the level of Pro and Hyp in body fluids from patients with bone disease, tumours or chronic uraemia.  相似文献   

13.
A simple and rapid capillary electrophoresis (CE) with an acidic potassium permanganate chemiluminescence (CL) detection method was developed to determine three alkaloids (curine, sinomenine and magnoflorine) simultaneously. A laboratory‐built CE–CL detection interface was used. The field‐amplified sample stacking technique was applied to the online concentration of alkaloids. Experimental conditions for CE separation and CL detection were investigated in detail to acquire optimum conditions. Under optimal conditions, the three alkaloids were baseline separated within 6 min, and the detection limits (S/N = 3) ranged from 0.03 µg/mL to 0.49 µg/mL. This method was successfully applied to determine the above three alkaloids in Sinomenium acutum, and the result of the determination of sinomenine was in good agreement with those given by high‐performance liquid chromatography and CE methods. In addition, a possible CL reaction mechanism of sinomenine–KMnO4–H2SO4 was proposed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
We developed an isotope dilution HPLC-atmospheric pressure chemical ionization-tandem mass spectrometry (HPLC-APCI-MS/MS) method for the simultaneous determination of p-tyrosine, phenylalanine, o,o'-dityrosine, m-tyrosine, o-tyrosine, 3-chlorotyrosine and 3-nitrotyrosine and 8-hydroxy-2'-deoxyguanosine (8-OHdG) that requires no extensive sample pre-treatment. p-[(2)H(4)]Tyrosine and o,o'-[(2)H(6)]dityrosine were used as internal standards. Calibration curves of the method were linear (r(2)=0.990-0.999) over a concentration range of 0.03-10 microM for o-tyrosine; 0.04-10 microM for 3-nitrotyrosine and 3-chlorotyrosine; 0.05-10 microM for o,o'-dityrosine; and for m-tyrosine; 1.0-100 microM for p-tyrosine and for phenylalanine; and 0.01-10 microM for 8-OHdG. The detection limits were from 0.025 to 0.05 microM for the tyrosine derivatives; 0.01 microM for 8-OHdG; and 0.5 microM for p-tyrosine and for phenylalanine, respectively. Within-day coefficients of variation (CV) for spiked human urine samples ranged from 2.7 to 7.0%, except for 8-OHdG (13.7%). Between-day variations ranged from 7.9 to 13.0%, except for o-tyrosine (CV = 18.2%), and for 8-OHdG (CV = 24.7%).The background levels of p-tyrosine, phenylalanine, o,o'-dityrosine, and o-tyrosine in morning urine of eight healthy volunteers were 3890+/-590, 3420+/-730, 5.8+/-0.3, and 9.2+/-1.5 micromol/mol creatinine, respectively. Using the present HPLC-APCI-MS/MS method, the urinary background levels of m-tyrosine, 3-chlorotyrosine, 3-nitrotyrosine and 8-OHdG were below the limit of detection.  相似文献   

15.
Capillary electrophoresis (CE) coupled to tandem mass spectrometry was applied to the chiral separation of baclofen using sulfobutylether-beta-cyclodextrin chiral selector in partial filling counter current mode. On-line UV detection was simultaneously used. Method optimization was performed by studying the effect of cyclodextrin and BGE concentration as well as sheath liquid composition on analyte migration time and enantiomeric resolution. The cyclodextrin showed stereoselective complexation towards baclofen enantiomers, allowing chiral resolution at low concentration. The CE capillary protrusion from the ESI needle relevantly affected the chiral resolution and the analyte migration time. Complete enantiomeric separation was obtained by using 0.25 M formic acid BGE containing 1.75 mM of chiral selector and water/methanol (30:70, v/v) 3% formic acid as sheath liquid. The method exhibited a LOD of 0.1 microg/mL (racemic concentration) in MS3 product ion scan mode of detection and was applied to the analysis of racemic baclofen in pharmaceutical formulations.  相似文献   

16.
Solid phase extraction (SPE) was coupled at line to capillary electrophoresis (CE) for the determination of three basic and neutral diabetic drugs (metformin, phenformin and glyburide) in human plasma. The SPE procedure employed a C(18) cartridge to remove most of the water and proteins from the plasma sample. Analyte detectability was increased due to trace enrichment during the SPE process. Elution of metformin, phenformin and glyburide was achieved with methanol+3% acetic acid. CE analysis was performed using a non-aqueous buffer, acetonitrile+5mM ammonium acetate+5% acetic acid, which afforded rapid separation of metformin from phenformin within 3 min. Glyburide, with a migration time longer than 6 min, did not cause any interference. The present SPE-CE method, with an electrokinetic injection time of 6s and UV detection at 240 nm, was useful for monitoring down to 1 microg/mL of metformin and phenformin in human plasma. When the electrokinetic injection time was increased to 36s, the detection limits were improved to 12 ng/mL for metformin and 6 ng/mL for phenformin.  相似文献   

17.
Bisphosphonate compounds have been studied as a class of potential drugs for the treatment of various bone diseases. However, the analyses of these compounds are problematic because most of them do not contain strong chromophores. Based on the unique structures of these compounds, we have employed a capillary electrophoresis (CE) technique for the characterization of these compounds in pharmaceutical dosage formulations. In this study, two CE methods were developed for the determination of a bisphosphonate compound, 2-thioethane-1,1-bisphosphonic acid. The first method involved the use of an uncoated column, a phosphate buffer, and hydrostatic injection with direct UV absorbance detection. The method showed excellent resolution and precision with a reasonable detection limit of 30 μg/ml. Sensitivity was further improved using a glycerol-coated column, together with a phosphate buffer of higher concentration and electrokinetic injection under sample stacking conditions. This modified method revealed a significant improvement in sensitivity with a detection limit of about 50 ng/ml. Both methods demonstrated high simplicity and excellent reproducibility and were successfully applied to the quantitative analyses of pharmaceutical dosing solutions.  相似文献   

18.
Capillary electrophoresis (CE) was employed to analyze lactate dehydrogenase (LDH) in human erythrocytes using an amperometric detector with a carbon fiber micro-disk bundle electrode. LDH activity was measured by determining the amount of NADH generated by LDH through a enzyme-catalyzed reaction between NAD(+) and lithium lactate. The factors influencing the enzyme-catalyzed reaction, separation and detection were examined and optimized. The following conditions were suitable for the determination of LDH: running buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 7.5); separation voltage, 20.0 kV; detection potential, 1.00 V (versus saturated calomel electrode (SCE)). The conditions of enzyme-catalyzed reaction were: reaction buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 9.3); substrates, 5.0 x 10(-2)mol/l lithium lactate and 5.0 x 10(-3)mol/l NAD(+); reaction time, 10 min. The concentration limit of detection (LOD) of the method was 0.017 U/ml at a signal-to-noise (S/N) ratio of 3, which corresponded to 1.10 x 10(-10)mol/l, and the mass LOD was 2 x 10(-20)mol. The linear dynamic range was 0.039-4.65 U/ml for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the electrophoretic peak area. The method was applied to determine LDH in human erythrocytes. The recovery of the method was between 98 and 101%.  相似文献   

19.
3-Nitrotyrosine (NO(2)Tyr) is a potential biomarker of reactive-nitrogen species (RNS) including peroxynitrite. 3-Nitrotyrosine occurs in human plasma in its free and protein-associated forms and is excreted in the urine. Measurement of 3-nitrotyrosine in human plasma is invasive and associated with numerous methodological problems. Recently, we have described an accurate method based on gas chromatography (GC)-tandem mass spectrometry (MS) for circulating 3-nitrotyrosine. The present article describes the extension of this method to urinary 3-nitrotyrosine. The method involves separation of urinary 3-nitrotyrosine from nitrite, nitrate and l-tyrosine by HPLC, preparation of the n-propyl-pentafluoropropionyltrimethylsilyl ether derivatives of endogenous 3-nitrotyrosine and the internal standard 3-nitro-l-[(2)H(3)]tyrosine, and GC-tandem MS quantification in the selected-reaction monitoring mode under negative-ion chemical ionization conditions. In urine of ten apparently healthy volunteers (years of age, 36.5+/-7.2) 3-nitrotyrosine levels were determined to be 8.4+/-10.4 nM (range, 1.6-33.2 nM) or 0.46+/-0.49 nmol/mmol creatinine (range, 0.05-1.30 nmol/mmol creatinine). The present GC-tandem MS method provides accurate values of 3-nitrotyrosine in human urine at the basal state. After oral intake of 3-nitro-l-tyrosine by a healthy volunteer (27.6 microg/kg body weight) 3-nitro-l-tyrosine appeared rapidly in the urine and was excreted following a biphasic pharmacokinetic profile. Approximately one third of administered 3-nitro-l-tyrosine was excreted within the first 8 h. The suitability of the non-invasive measurement of urinary 3-nitrotyrosine as a method of assessment of oxidative stress in humans remains to be established.  相似文献   

20.
Sulpiride and tiapride are often used in the treatment of depression, schizophrenia and psychopathology of senescence, gastric or duodenal ulcers and are also partly excreted by kidney. This work developed a simple and sensitive method for their simultaneous monitoring in human urine based on capillary electrophoresis coupled with electrochemiluminescence detection by end-column mode. beta-Cyclodextrin (beta-CD) was used as an additive to the running buffer to obtain the absolute separation of sulpiride and tiapride. Under optimized conditions the proposed method displayed a linear range from 1.0 x 10(-7) to 1.0 x 10(-4) M for both sulpiride and tiapride with the correlation coefficients more than 0.995 (n = 6). Their limits of detection were 1.0 x 10(-8) M (45 amol) and 1.5 x 10(-8) M (68 amol) at a signal to noise ratio of 3, respectively. The relative standard deviations for six determinations of 2.0 microM sulpiride and 3.0 microM tiapride were 1.8 and 2.5%, respectively. For practical application an extract step with ethyl acetate at pH 11 was performed to eliminate the influence of ionic strength in sample. The recoveries of sulpiride and tiapride at different levels in human urine were between 84 and 95%, which showed that the method was valuable in clinical and biochemical laboratories for monitoring sulpiride and tiapride for various purposes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号