首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Magnetoresistive-based biosensors and biochips   总被引:5,自引:0,他引:5  
Over the past five years, magnetoelectronics has emerged as a promising new platform technology for biosensor and biochip development. The techniques are based on the detection of the magnetic fringe field of a magnetically labeled biomolecule interacting with a complementary biomolecule bound to a magnetic-field sensor. Magnetoresistive-based sensors, conventionally used as read heads in hard disk drives, have been used in combination with biologically functionalized magnetic labels to demonstrate the detection of molecular recognition. Real-world bio-applications are now being investigated, enabling tailored device design, based on sensor and label characteristics. This detection platform provides a robust, inexpensive sensing technique with high sensitivity and considerable scope for quantitative signal data, enabling magnetoresistive biochips to meet specific diagnostic needs that are not met by existing technologies.  相似文献   

2.
《IRBM》2008,29(2-3):105-127
The present review describes the multidisciplinary approach followed by the Chemistry and Nanobiotechnology group of INL since ten years, to develop a complete technological platform dedicated to molecular diagnosis using biochips and biosensors. This work, replaced in an international context, illustrates the importance to identify the various pitfalls inherent to molecular analysis throughout an elaboration and analysis line: choice of solid support, surface physicochemistry, immobilisation of biomolecules, biomolecular recognition, microfluidics and detection.  相似文献   

3.
Nanospheres lithographic (NSL) method has been used to fabricate nano-structured arrays (NAs) of hexagonally close-packed gold (Au) using polystyrene beads [PS, diameter ~300 nm] as mask. The developed NA was incorporated with a customized and cheap microfluidics system to demonstrate its applicability as an alternative easy and efficient platform for multiplex analysis and Lab-on-a-Chip applications. The chip functionality was demonstrated with horseradish peroxidase (HRP) and anti-HRP antibody as model for recognition system. The enzyme-linked immunosorbent assay (ELISA) performed on fabricated protein biochip had a detection limit 100 pg/mL for HRP. The antibody chip was also checked for the shelf-life and it was found that these chips could be stored for 50 days when stored at 4°C without any significant loss of activity. Therefore, NAs based protein biochip with the correct microfluidics could find huge potential application in diagnostics and biosensing technology.  相似文献   

4.
The current status and research trends of detection techniques for DNA-based analysis such as DNA finger printing, sequencing, biochips and allied fields are examined. An overview of main detectors is presented vis-à-vis these DNA operations. The biochip method is explained, the role of micro- and nanoelectronic technologies in biochip realization is highlighted, various optical and electrical detection principles employed in biochips are indicated, and the operational mechanisms of these detection devices are described. Although a diversity of biochips for diagnostic and therapeutic applications has been demonstrated in research laboratories worldwide, only some of these chips have entered the clinical market, and more chips are awaiting commercialization. The necessity of tagging is eliminated in refractive-index change based devices, but the basic flaw of indirect nature of most detection methodologies can only be overcome by generic and/or reagentless DNA sensors such as the conductance-based approach and the DNA-single electron transistor (DNA-SET) structure. Devices of the electrical detection-based category are expected to pave the pathway for the next-generation DNA chips. The review provides a comprehensive coverage of the detection technologies for DNA finger printing, sequencing and related techniques, encompassing a variety of methods from the primitive art to the state-of-the-art scenario as well as promising methods for the future.  相似文献   

5.
A rapid and accurate detection of molecular binding of antigen-antibody signaling in high throughput is of great importance for biosensing technology. We proposed a novel optical biochip with multichannels for the purpose of detection of biotin–streptavidin on the basis of localized surface plasmon resonance. The optical biochip was fabricated using photolithography to form the microarrays functioning with multichannels on glass substrate. There are different nanostructures in each microarray. Dry etching and nanosphere lithography techniques were applied to fabricate Ag nanostructures such as hemispheres, nanocylindricals, triangular, and rhombic nanostructures. We demonstrated that 100-nM target molecule (streptavidin) on these optical biochips can be easily detected by a UV-visible spectrometer. It indicated that period and shape of the nanostructures significantly affect the optical performance of the nanostructures with different shapes and geometrical parameters. Our experimental results demonstrated that the optical biochips with the multichannels can detect the target molecule using the microarrays structured with different shapes and periods simultaneously. Batch processing of immunoassay for different biomolecular through the different channels embedded on the same chip can be realized accordingly.  相似文献   

6.
几种新型生物芯片的研究进展   总被引:17,自引:0,他引:17  
随着生物芯片技术的迅速发展,一些新型生物芯片,如生物电子芯片、凝胶元件微阵列芯片、药物控释芯片、毛细管电泳或层析芯片、PCR芯片及生物传感芯片等应运而生,这些芯片不同于常规的分子微阵列芯片,而是以各种结构微阵列为基础,用于分子杂交与扩增,以检测突变、分析多态性及测序,通过电泳及层析分离生物样品,控制药物释放以治疗疾病,作为生物传感器检测分子行为等,具有分析速度快、效率高、样品消耗少等特点,将成为生命科学与医学领域的新工具.  相似文献   

7.
An aptamer-based biochip for protein detection and quantitation which combines the recent biochip technology and the conventional staining methods, is described. Using a model system comprising His-tagged proteins as the analyte and single-stranded RNA aptamers specific for His-tagged proteins as immobilized ligands on chips, we could demonstrate that aptamers were equivalent or superior to antibodies in terms of specificity and sensitivity, respectively. The sensor has the characteristics of good stability, reproducibility and reusability, with detection limit as low as 85 ng/mL His-tagged protein. It has been demonstrated that the sensor can be stored for at least 4 weeks and reused with reasonable reduction rate of staining intensity. In conclusion, we could show the suitability of nucleic acid aptamers as low molecular weight receptors on biochips for sensitive and specific protein detection and quantitation.  相似文献   

8.
This work describes an ultraviolet biosensing technique based on specific molecular absorption detected with a previously developed spectrally selective aluminum gallium nitride (AlGaN) based detector. Light absorption signal of DNA and proteins, respectively at 260 nm and 280 nm, is used to image biochips. To allow detection of protein or DNA monolayers at the surface of a biochip, we develop contrast-enhancing multilayer substrates. We analyze them through models and experiments and validate the possibility of measuring absorptions of the order of 10(-3). These multilayer structures display a high reflectivity, and maximize the interaction of the electric field with the biological element at the chip surface. Optimization of the experimental absorption, which includes effects such as roughness of the biochip, spectral and angular resolution of the optics, illumination, etc., is carried out with an inorganic ultraviolet absorber (titanium dioxide) deposit. We obtained an induced absorption contrast enhanced by a factor of 4.0, conferring enough sensitivity to detect monolayers of DNA or proteins. Experimental results on an Escherichia coli histidine-tagged methionyl-tRNA synthetase protein before and after complexation with an anti-polyHis specific antibody validate our biosensing technique. This label-free optical method may be helpful in controlling biochip coatings, and subsequent biological coupling at the surface of a biochip.  相似文献   

9.
A method for fluorescently labeled single-stranded DNA (ssDNA) production during single-stage polymerase chain reaction (PCR) for subsequent hybridization on a biochip was described. This approach, whose efficiency was confirmed in the case of DARC gene, is considered as an alternative to two-stage nested PCR, consisting of two separate reactions: symmetric and asymmetric. Implementation of PCR in a single stage was achieved due to the use of a truncated excess primer in the second stage that does not anneal on the matrix during the cycles of symmetric stage of PCR and that enters the reaction after decrease of the annealing temperature in asymmetric stage. As a result, high efficiency of genotyping by means of hybridization on biochips is maintained. The suggested approach will allow us to reduce the time, working hours, and risk of contamination when researching biochips.  相似文献   

10.
We describe the microfabrication and operational characteristics of a simple flow-through biochip sensor capable of detecting low abundant point mutations in K-ras oncogenes from genomic DNA, which carry high diagnostic value for colorectal cancers. The biochip consisted of an allele-specific ligase detection reaction (LDR) coupled to a universal array for interrogating multiple mutations simultaneously from a clinical sample. The integrated sensing platform was micro-manufactured from two different polymers, polycarbonate, PC, which was used for the LDRs, and poly(methyl methacrylate), PMMA, which was used to build the microarray. Passive elements were hot embossed into the PC and PMMA microchips and then, the chips assembled into a three-dimensional architecture with the interconnect fabricated from an elastomer, poly(dimethylsiloxane), PDMS, to produce a leak-free connection between the biochips. The array in PMMA was produced using a photomodification process, which involved three steps; (1) UV (254 nm) exposure of the polymer surface; (2) EDC coupling of amine-terminated oligonucleotide probes to the surface (via an amide bond) and; (3) washing of the surface. The LDR/hybridization flow-through biochip performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time=19.1 min) and could screen multiple mutations simultaneously for high throughput applications at a level of one mutant sequence in 100 wild-type sequences.  相似文献   

11.
Biomolecules, especially proteins and nucleic acids, have been widely studied to develop biochips for various applications in scientific fields ranging from bioelectronics to stem cell research. However, restrictions exist due to the inherent characteristics of biomolecules, such as instability and the constraint of granting the functionality to the biochip. Introduction of functional nanomaterials, recently being researched and developed, to biomolecules have been widely researched to develop the nanobiohybrid materials because such materials have the potential to enhance and extend the function of biomolecules on a biochip. The potential for applying nanobiohybrid materials is especially high in the field of bioelectronics. Research in bioelectronics is aimed at realizing electronic functions using the inherent properties of biomolecules. To achieve this, various biomolecules possessing unique properties have been combined with novel nanomaterials to develop bioelectronic devices such as highly sensitive electrochemical‐based bioelectronic sensing platforms, logic gates, and biocomputing systems. In this review, recently reported bioelectronic devices based on nanobiohybrid materials are discussed. The authors believe that this review will suggest innovative and creative directions to develop the next generation of multifunctional bioelectronic devices.  相似文献   

12.
Three-dimensional gel-based microchip allowing simultaneous quantitative detection of total (PSAtot) and free (PSAfree) forms of prostate specific antigen in human serum (in a format "one patient-one biochip") was developed. A method, which doesn't require preliminary construction of calibration curves when performing an assay, was applied for quantitative determination of PSAtot and PSAfree. Gel elements with immobilized antigen (PSA) in different concentration, forming an internal calibration curve, were included in a structure of the microchip, in addition to the elements with immobilized antibodies specific against PSAtot and PSAfree. The specialized software "ImaGelAssay" was used for data processing and interpretation. The sensitivity of the assay performed on biochips was 0.3 ng/ml for PSAtot and 0.2 ng/ml for PSAfree. Variation coefficient for the measurements inside one series of microchips didn't exceed 10%. Correlation coefficient between the results of measurements in human sera obtained on biochips and by the standard ELISA method was 0.988 for PSAtot and 0.987 for PSAfree.  相似文献   

13.
生物芯片在食品检测中的应用   总被引:1,自引:0,他引:1  
生物芯片是上世纪末发展起来的一种微量分析技术,因具有准确、快速、信息量大等特点而发展迅速。简要介绍了生物芯片的基本原理、种类及其X-作原理与应用前景,并深入探讨了生物芯片在食品检测中的应用,包括对转基因食品、食品微生物、食品营养成分、食品原料等的检测;对现今生物芯片应用中存在的问题与未来的发展前景做了分析展望。  相似文献   

14.
Understanding the biological processes in cells, tissues, and organisms requires the identification and analysis of multiple biological objects and the mechanisms of their functioning and regulation. The biological chip (biochip) technique is one of the most efficient tools for these tasks. Biochips are highly efficient and can quantitatively register multiple molecules simultaneously in samples of microscopic volume. Biochips allow the parallel genomic or proteomic analysis of normal or pathologically modified cells and tissues and a comparative analysis to elucidate disease-related changes. Fluorescent dyes used for signal readout from biochips have the following disadvantages: low photostability, low brightness, and the presence of a fluorescent background. It was recently shown that these limitations can be removed if fluorescent semiconductor nanocrystals (quantum dots) are used. Individual quantum dots in the form of colloid nanocrystals (QDs) are easily registered by conventional microscopic equipment due to their high brightness; they are extremely resistant to photobleaching and provide unique opportunities for multiplexing. QDs are ideal fluorophores for information readout from biochips and allow for the detection of single molecules. The present work is aimed at developing approaches for the use of QDs in biochip-based detection systems. The possibilities of using QDs in both planar (or matrix) biochips and suspension (or liquid) biochips, which are undergoing intensive development, are demonstrated. The use of the latter in analytical systems for the simultaneous identification of multiple objects in proteomics, genomics, drug testing, and clinical diagnostics is currently increasing. These systems are based on spectrally coded elements (usually polymer microspheres). An advantage of liquid biochips over matrix planar solid biochips is the possibility of the free movement of microspheres in three-dimensional space. Organic fluorophores allow the realization of a limited number of codes, i.e., objects analyzed simultaneously (multiplexing), while semiconductor QDs make possible a significant increase in both biochip multiplexing and the photostability and sensitivity of the biochips. In addition, the use of FRET (Foerster resonance energy transfer) in liquid biochips makes possible an increase in the detection specificity. The absence of a background signal from the fluorescent labels not bound to the microparticles increases the sensitivity of the analysis and provides additional opportunities for multiplex analysis and diagnostics. Thus, a combination of the biochip technique and semiconductor QDs makes it possible to increase the method’s sensitivity and the number of objects detected (the degree of multiplexing). This combination is likely to enable a significant breakthrough in proteomics, particularly in the development of new drugs, clinical diagnostics, identification of molecular markers, and elucidation of the intracellular processes.  相似文献   

15.
Recently in Russia biochips for rifampin resistance detection of M. tuberculosis were developed. To investigate the conformity between rifampin resistance results determined both by the routinely used absolute concentration method and USING the biochips, 272 DNA samples of M. tuberculosis isolated from TB patients at Novosibirsk and Tomsk regions in 2000-2005 were analyzed. The biochip can detect 30 mutations in rpoB gene. The mutations were also tested using the single stranded conformational polymorphism method (SSCP). In addition, 60 DNAs were randomly sampled and sequenced. The results of rifampin resistance detection using biochip and absolute concentration methods were congruent in 86% cases, and were different when analyzed samples consisted of the susceptible and resistant strains of M. tuberculosis mixture. The most frequent mutations in the rpoB gene were S531 (76.2%), H526 (7%), D516 (5.6%), and L511 (5.6%). In 94% of rifampin resistant strains, there was also resistance to isoniazid. Therefore, in Siberia the rifampin resistance is the reliable marker for MDR strains of M. tuberculosis, and biochips can be used also for their detection. To hybridize with biochip the fluorescent-labeled single-stranded DNAs were routinely synthesized by two PCR, and intermediary product after the first PCR should be transferred into another tube. The last stage included high risk of cross-contamination. To exclude the risk, primer concentrations and temperature-time profile of PCR reactions were improved, and both PCR were combined in one tube. The two methods were congruent in 100%. The one tube method would be especially attractive for the routine PCR laboratory.  相似文献   

16.
This study utilized the radio frequency (RF) technology to develop a multilayered polymeric DNA sensor with the help of gold and magnetic nanoparticles. The flexible polymeric materials, poly (p-xylylene) (Parylene) and polyethylene naphtholate (PEN), were used as substrates to replace the conventional rigid substrates such as glass and silicon wafers. The multilayered polymeric RF biosensor, including the two polymer layers and two copper transmission structure layers, was developed to reduce the total sensor size and further enhance the sensitivity of the biochip in the RF DNA detection. Thioglycolic acid (TGA) was used on the surface of the proposed biochip to form a thiolate-modified sensing surface for DNA hybridization. Gold nanoparticles (AuNPs) and magnetic nanoparticles (MNPs) were used to immobilize on the surface of the biosensor to enhance overall detection sensitivity. In addition to gold nanoparticles, the magnetic nanoparticles has been demonstrated the applicability for RF DNA detection. The performance of the proposed biosensor was evaluated by the shift of the center frequency of the RF biosensor because the electromagnetic characteristic of the biosensors can be altered by the immobilized multilayer nanoparticles on the biosensor. The experimental results show that the detection limit of the DNA concentration can reach as low as 10 pM, and the largest shift of the center frequency with triple-layer AuNPs and MNPs can approach 0.9 and 0.7 GHz, respectively. Such the achievement implies that the developed biosensor can offer an alternative inexpensive, disposable, and highly sensitive option for application in biomedicine diagnostic systems because the price and size of each biochip can be effectively reduced by using fully polymeric materials and multilayer-detecting structures.  相似文献   

17.
Near infrared spectroscopy is a rapid and nondestructive method for compositional analysis of biological material. The technology is widely used within bioreactors and possesses potential as a standardized method for quality control in miniaturized microfluidic cell culture systems. Here, we established a method for quantification of cell density and viability of adherent HepaRG cells cultured in a translucent, miniaturized cell culture biochip. The newly developed statistical models for interpretation of near infrared spectroscopy from biochips are the basis for a novel method of fast, continuous, and contact‐free analysis of cell viability and real‐time monitoring of cell growth. The technique thus paves the way for a robust and reliable high‐throughput analysis of biochip‐embedded cell cultures.  相似文献   

18.
Although biosensors detecting a great variety of toxicants have been developed during the last decades, the simultaneous detection and identification of several targets by one biosensor is not possible in the majority of the biosensor systems. In our study we proved the concept of the detection and identification of two different volatile toxic compounds with a non-selective biochip-based algal biosensor. For that purpose we produced array plate biochips to utilise three membrane-immobilised algal strains of genus Klebsormidium and Chlorella in one biosensor system. A novel IMAGING-PAM chlorophyll fluorometer was applied to measure the impact of volatile organic compounds (VOC) on photosynthesis of chip-immobilized algae in terms of quantum efficiency of electron transport (DeltaF/F'm). Formaldehyde (FA) vapour was detectable with statistical significance in concentrations relevant to human health from 10 ppb to 10 ppm. The biosensor response recorded within minutes was concentration-dependent and reversible. Moreover, vapours of formaldehyde (0.05-1 ppm) and methanol (MeOH) (200-1000 ppm) were significantly identified by the compound-specific response rate as a quotient of the biosensor responses of the respective algal strains. Using the IMAGING-PAM chlorophyll fluorometer, data sampling proved to be highly efficient. Based on our results we conclude that the principle of the algal sensor chip (ASC) suggests further research on the detection and identification of VOCs and other toxic substances in gaseous environment with that biochip system.  相似文献   

19.
Highly controlled supramolecular assemblies combining a genetically engineered redox protein, cytochrome b5, and modified oligonucleotides are presented. Modified b5 and DNA are covalently assembled through a hetero bifunctional cross-linker to give a unique hybrid molecular species. Moreover, the assembly includes a histidine tag head able to bind to modified phospholipids which lead to a new generation of self-assembled dynamic DNA chips. The interaction of the construction with a complementary oligonucleotide sequence can be monitored in real time by surface plasmon resonance using Biacore technology. The biochip, presented herein, features unique properties including tunable surface density of probes, very low non-specific interactions and optimization of hybridization efficiency. In addition, we demonstrated that the phase transition of the lipidic layer can modulate the dynamic of the association of the complex to the supported membrane. Potential applications of this new device are multiple including high sensitivity and high selectivity biochips, especially for studies of the DNA-ligands interactions in a biomimetic environment.  相似文献   

20.
Miniaturization of analytical benchtop procedures into the micro-scale provides significant advantages in regards to reaction time, cost, and integration of pre-processing steps. Utilizing these devices towards the analysis of DNA hybridization events is important because it offers a technology for real time assessment of biomarkers at the point-of-care for various diseases. However, when the device footprint decreases the dominance of various physical phenomena increases. These phenomena influence the fabrication precision and operation reliability of the device. Therefore, there is a great need to accurately fabricate and operate these devices in a reproducible manner in order to improve the overall performance. Here, we describe the protocols and the methods used for the fabrication and the operation of a microfluidic-based electrochemical biochip for accurate analysis of DNA hybridization events. The biochip is composed of two parts: a microfluidic chip with three parallel micro-channels made of polydimethylsiloxane (PDMS), and a 3 x 3 arrayed electrochemical micro-chip. The DNA hybridization events are detected using electrochemical impedance spectroscopy (EIS) analysis. The EIS analysis enables monitoring variations of the properties of the electrochemical system that are dominant at these length scales. With the ability to monitor changes of both charge transfer and diffusional resistance with the biosensor, we demonstrate the selectivity to complementary ssDNA targets, a calculated detection limit of 3.8 nM, and a 13% cross-reactivity with other non-complementary ssDNA following 20 min of incubation. This methodology can improve the performance of miniaturized devices by elucidating on the behavior of diffusion at the micro-scale regime and by enabling the study of DNA hybridization events.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号