首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
The dynamic behavior of polar molecules in egg phosphatidylcholine (PC) bilayers has been studied using a membrane fluorescent probe, 4'-dimethylaminochalcone (DMAC). Time and spectrally resolved fluorescence spectroscopy of DMAC incorporated in PC liposomes, as compared to studies of the probe in organic solvents, shows the existence of two independent populations, associated with different extent and speed of dipolar solvent relaxation. The first DMAC population represents approximately 69% of the fluorescence-emitting molecules, has a short fluorescence decay time (0.32 ns) and undergoes Stokes shift of 80 nm. The remaining 31% fraction of DMAC molecules has a decay time of 0.74 ns and undergoes a high (106 nm) Stokes shift. A fraction of the shift, ca. 24 nm for the first and 46 nm for the second population, is attributed to the fast (<0.1 ns) rotational relaxation of nearby dipolar molecules, which might be water. This two-state model accounts well for the detailed fluorescence properties of DMAC in egg PC, i.e. its broadened steady-state spectrum, its average fluorescence quantum yield and its complex wavelength-dependent fluorescence decays.  相似文献   

3.
A procedure is described by which the information available from nanosecond time-resolved fluorescence measurements can be used to study rates of reactions taking place on time scales of seconds to hours. A pulse fluorometer was modified so as to obtain a series of short sequential data collections which were rapidly stored on computer disk files. As an application of this new methodology, the unfolding of horse liver alcohol dehydrogenase under acid conditions was monitored by changes in the decay parameters of the intrinsic fluorescence. Although the individual decay curves each had relatively few counts (330 to 160 counts at the peak), a series of decay curves obtained as a function of time could be analyzed in terms of a biexponential function. It was found that the decrease in steady-state fluorescence could be explained most simply by a decrease in the amplitude associated with the longer of the two decay constants.  相似文献   

4.
The present study describes a novel fluorometer system which permits the simultaneous monitoring of the time and wavelength dependence of chlorophyll fluorescence in the picosecond time domain. The key element of this equipment is a microchannel-plate photomultiplier with delay-line anode. The comparatively short acquisition times in combination with full spectral and temporal resolution of this device are of high advantage, especially for measurements on photosynthetic samples at cryogenic temperatures. For a convenient numerical data evaluation of complex overlapping spectra a decay-associated gaussian deconvolution technique was installed by developing a fitting program with graphical user-interface. In order to illustrate the potential of the new set-up, surface plots and decay spectra gathered from measurements with anaerobically photoinhibited Photosystem II particles at 277 K and 10 K are presented.  相似文献   

5.
We describe the construction and performance of a variable-frequency phase-modulation fluorometer. This instrument, which provides modulation frequencies from 1 to 200 MHz, was constructed using commercially available components. To facilitate the introduction of these instruments into other laboratories we describe in detail the chosen components and the principles of operation. The present light source is a continuous-wave helium-cadmium laser, which provides convenient excitation wavelengths of 325 and 442 nm. Modulation of the incident light is provided by one of several electro-optic modulators. The extent of modulation ranges from 1.0 to 0.2 as the frequency increases from 1 to 200 MHz. Phase angles and demodulation factors are measured using the cross-correlation method. The closely spaced frequencies are provided by two direct frequency synthesizers. The phase and modulation measurements are accurate to 0.2 degrees and 0.002, respectively, from 1 to 200 MHz. This accuracy allows considerable resolution of complex decay laws. The usefulness of frequency-domain fluorometry for the resolution of multiexponential decays is illustrated by the analysis of several difficult mixtures. As examples, we resolved a two-component mixture of anthracene (4.1 ns) and 9,10-diphenylanthracene (6.3 ns), and confirmed that the intensity decay of NADH in aqueous buffer is at least a double exponential (0.2 and 0.86 ns). We also resolved an especially difficult mixture of anthracene (4.1 ns) and 9-methylanthracene (4.5 ns), and a three-component mixture with decay times of 1.3, 4.1 and 7.7 ns. Frequency-domain fluorometers appear to be particularly useful for determination of complex decays of fluorescence anisotropy. This capability is illustrated by the determination of rotational correlation times as short as 47 ps for p-bis[2-(5-phenyloxazolyl)]benzene (POPOP) in hexane at 40 degrees C, and by the resolution of the two correlation times of anisotropic rotators such as perylene and 9-aminoacridine. Resolution of two anisotropy decay times for 9-aminoacridine is a difficult test because these correlation times differ by less than 2-fold. The resolution of multiexponential decays of intensity and anisotropy possible with this instrument is at least equivalent to that obtained using state-of-the-art time-resolved instruments based on mode-locked laser sources. The ease and rapidity of frequency-domain measurements, the relative simplicity of the equipment, the accuracy of the measurements and the lack of significant systematic errors indicate that frequency-domain fluorometry will be widely useful in chemical and biochemical research.  相似文献   

6.
Urban  O.  Trtilek  M.  Feild  T.  Nedbal  L. 《Photosynthetica》1999,37(2):201-207
The earlier developed double-modulation chlorphyll (Chl) fluorometer was modified for measurements with intact leaves of higher plants. The Chl fluorometer is based on a non-periodic modulation of both actinic and measuring flashes. In addition, continuous orange actinic and far-red radiation were produced by separate arrays of light-emitting diodes (LEDs). Programmable timing of the flashes allows to cover a wide dynamic range from microseconds to minutes. We have demonstrated that the LEDs can produce single-turnover flashes that saturate QA reduction of intact leaves of Glyceria maxima and shoots of Picea abies. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

7.
Here, we report novel methods to measure rate constants for homodimer subunit exchange using double electron–electron resonance (DEER) electron paramagnetic resonance spectroscopy measurements and nuclear magnetic resonance spectroscopy based paramagnetic relaxation enhancement (PRE) measurements. The techniques were demonstrated using the homodimeric protein Dsy0195 from the strictly anaerobic bacterium Desulfitobacterium hafniense Y51. At specific times following mixing site-specific MTSL-labeled Dsy0195 with uniformly 15N-labeled Dsy0195, the extent of exchange was determined either by monitoring the decrease of MTSL-labeled homodimer from the decay of the DEER modulation depth or by quantifying the increase of MTSL-labeled/15N-labeled heterodimer using PREs. Repeated measurements at several time points following mixing enabled determination of the homodimer subunit dissociation rate constant, k ?1, which was 0.037 ± 0.005 min?1 derived from DEER experiments with a corresponding half-life time of 18.7 min. These numbers agreed with independent measurements obtained from PRE experiments. These methods can be broadly applied to protein–protein and protein-DNA complex studies.  相似文献   

8.
Measurements of homogeneous and heterogeneous fluorescence intensity decays using a hybrid time-correlated single photon counting/multifrequency phase fluorometer are reported. A trio of fluorophores exhibiting a range of decay profiles was selected. p-Terphenyl, 1,4-bis[2-(4-methyl-5-phenyloxazolyl)]benzene [(Me)2POPOP], and p-bis[2-(5-phenyloxazolyl)]benzene (POPOP), commonly used reference fluorophores, were analyzed initially; their emissions were characterized by monoexponential decay functions. Additionally, emissions from two single tryptophan proteins with different decay profiles were measured. Scorpion neurotoxin variant 3 required three exponentials to fit the emission decay properly (average lifetime approximately 500 ps). At pH 5.5, the fluorescence emission of ribonuclease T1 showed a monoexponential decay with a measured lifetime of approximately 4.0 ns. Thus, in each case, the results from both measurements were consistent between the two detection systems, confirming the view that the two approaches for measuring fluorescence lifetimes are equivalent.  相似文献   

9.
Cartilage is a vital organ to maintain joint function. Upon arthritis, proteolytic enzymes initiate degradation of cartilage extracellular matrix (ECM) resulting in eventual loss of joint function. However, there are only limited ways of non-invasively monitoring early chemical changes in cartilage matrix. Here we report that the autofluorescence decay profiles of cartilage tissue are significantly affected by proteolytic degradation of cartilage ECM and can be characterised by measurements of the autofluorescence lifetime (AFL). A compact multidimensional fluorometer coupled to a fibre-optic probe was developed for single point measurements of AFL and applied to cartilage that was treated with different proteinases. Upon treating cartilage with bacterial collagenase, trypsin or matrix metalloproteinase 1, a significant dose and time dependent decrease of AFL was observed. Our data suggest that AFL of cartilage tissue is a potential non-invasive readout to monitor cartilage matrix integrity that may contribute to future diagnosis of cartilage defects as well as monitoring the efficacy of anti-joint therapeutic agents.  相似文献   

10.
Ecosystems sometimes shift between different states or dynamic regimes. Theory attributes these shifts to multiple ecosystem attractors. However, documenting multiple ecosystem attractors is difficult, particularly at spatial and temporal scales relevant to ecosystem management. We manipulated the fish community of a lake with the goal of causing trophic cascades and shifting the food web from a planktivore-dominated state to an alternate piscivore-dominated state. We evaluated evidence that the shifts in the fish community comprise alternate attractors using two complementary approaches. First, we calculated phase space trajectories to visualize the shift between attractors. Second, we computed generalized autoregressive conditional heteroskedasticity (GARCH) models and the Brock–Dechert–Scheinkman (BDS) test for linearity. The reconstructed phase space trajectories show the system departing a point attractor, entering a limit cycle, and then shifting to a new point attractor. The GARCH and BDS results indicate that linear explanations are not sufficient to explain the observed patterns. The results provide evidence for alternate attractors based on high-frequency time series of field measurements.  相似文献   

11.
We report the first time-resolved fluorescence emission spectra and time-resolved fluorescence anisotropies obtained using frequency-domain fluorescence spectroscopy. We examined the fluorophore p-2-toluidinyl-6-naphthalenesulfonic acid (TNS) in viscous solvents and bound to the heme site of apomyoglobin using multifrequency phase fluorometers. Fluorescence phase shift and modulation data were obtained at modulation frequencies ranging from 1 to 200 MHz. For time-resolved emission spectra, the impulse response for the decay of intensity at each emission wavelength was obtained from the frequency response of the sample at the same emission wavelength. The decays have negative pre-exponential factors, consistent with a time-dependent spectral shift to longer wavelengths. These multiexponential decays were used to construct the time-resolved emission spectra, which were found to be in good agreement with earlier spectra obtained from time-domain measurements. Additionally, time-resolved anisotropies were obtained from the frequency-dependent phase angle differences between the parallel and perpendicularly polarized components of the emission. The rotational correlation times of TNS bound to apomyoglobin are consistent with those expected for this probe rigidly bound to the protein. TNS in propylene glycol also displayed a single exponential decay of anisotropy. These results, in conjunction with the previous successful resolution of multiexponential decays of fluorescence intensity (Lakowicz, J. R., Gratton, E., Laczko, G., Cherek, H., and Limkeman, M. (1984) Biophys. J., in press; Gratton, E., Lakowicz, J. R., Maliwal, B. P., Cherek, H., Laczko, G., and Limkeman, M. (1984) Biophys. J., in press) demonstrate that frequency-domain measurements provide information which is, at a minimum, equivalent to that obtainable from time-domain measurements.  相似文献   

12.
Apomyoglobin was labeled with the fluorescent probe 2-p-toluidinylnaphthalene-6-sulfonic acid (TNS). Apparent phase shift and demodulation lifetimes of bound TNS were measured at various emission wavelengths. The lifetimes increased with increasing wavelength. Similar results were obtained for TNS in the viscous solvent glycerol at 10°C but not for TNS in vitrified or fluid solvent. The wavelength-dependent lifetimes suggest apomyoglobin is relaxing around the TNS molecule during its fluorescent lifetime. Importantly, the apparent phase lifetimes exceeded the apparent modulation lifetimes on the long wavelength side of the emission for TNS in apomyoglobin at 3°C and for TNS in glycerol at 10°C. This result proves the increasing lifetimes are a result of an excited state reaction during the lifetime of the excited state and are not a result of heterogeneity in the fluorescence emission. From the lifetimes on the short wavelength side of the emission the relaxation time of apomyoglobin was estimated to be 18 nsec.  相似文献   

13.
An approach for the design of high-power, broadband 180° pulses and mixing sequences for generating dipolar and scalar coupling mediated 13C–13C chemical shift correlation spectra of isotopically labelled biological systems at fast magic-angle spinning frequencies without 1H decoupling during mixing is presented. Considering RF field strengths in the range of 100–120 kHz, as typically available in MAS probes employed at high spinning speeds, and limited B 1 field inhomogeneities, the Fourier coefficients defining the phase modulation profile of the RF pulses were optimised numerically to obtain broadband inversion and refocussing pulses and mixing sequences. Experimental measurements were carried out to assess the performance characteristics of the mixing sequences reported here.  相似文献   

14.
Lewis JW  Szundi I  Kazmi MA  Sakmar TP  Kliger DS 《Biochemistry》2004,43(39):12614-12621
The role of glutamic acid 181 in the bovine rhodopsin retinylidene chromophore pocket was studied by expressing E181 mutants in COS cells and measuring, as a function of time, the absorbance changes produced after excitation of lauryl maltoside pigment suspensions with 7 ns laser pulses. All mutants studied except E181D showed accelerated decay of bathorhodopsin compared to wild type. Even for E181D, an anomalously large blue shift was observed in the absorption spectrum of the bathorhodopsin decay product, BSI. These observations support the idea that E181 plays a significant role in the earliest stages of receptor activation. E181 mutations have a pronounced effect on the decay of the lumirhodopsin photointermediate, primarily affecting the size of the red shift that occurs in the lumirhodopsin I to lumirhodopsin II transition that takes place on the 10 micros time scale after wild-type photoexcitation. While the spectral change that occurs in the lumirhodopsin I to lumirhodopsin II transition in wild-type rhodopsin is very small ( approximately 2 nm), making it difficult to detect, it is larger in E181D ( approximately 6 nm), making it evident even in the lower signal-to-noise ratio measurements possible with rhodopsin mutants. The change seen is even larger for the E181F mutant where significant amounts of a deprotonated Schiff base intermediate are produced with the 10 micros time constant of lumirhodopsin II formation. The E181Q mutant shows lumirhodopsin decay more similar to wild-type behavior, and no lumirhodopsin I to lumirhodopsin II transition can be resolved. The addition of chloride ion to E181Q increases the lumirhodopsin I-lumirhodopsin II spectral shift and slows the deprotonation of the Schiff base. The latter result is consistent with the idea that a negative charge at position 181 contributes to protonated Schiff base stability in the later intermediates.  相似文献   

15.
The measurement of fluorescence lifetimes is known to be hindered by the wavelenght-dependent and photocathode area-dependent time response of photomultiplier tubes. A simple and direct method is described to minimize the effects in photomultiplier tubes for phase-modulation fluorometry. Reference fluorophores of known lifetime were used in place of the usual scattering reference. The emission wavelenghts of the reference and sample were matched by either filters or a monochromator, and the use of a fluorophore rather than a scatter decreases the differences in spatial distribution of light emanating from the reference and sample. Thus photomultiplier tube artifacts are minimized. Five reference fluorophores were selected on the basis of availability, ease of solution preparation, and constancy of lifetime with temperature and emission wavelenght. These compounds are p-terphenyl, PPO, PPD, POPOP and dimethyl POPOP. These compounds are dissolved in ethanol to give standard solutions that can be used over the temperature range from ?55 to +55°C. Purging with inert gas is not necessary. The measured phase and modulation of the reference solution is used, in conjunction with the known reference, lifetime, to calculate the actual phase and modulation of the exictation beam. The use of standard fluorophores does not require separate experiments to quantify photomultiplier effects, and does not increase the time required for the measurement of fluorescence lifetimes. Examples are presented which demonstrate the elimination of artifactual photomultiplier effects in measurements of the lifetimes of DADH (0.4 ns) and indole solutions quenched by iodide. In addition, the use of these reference solutions increases the accuracy of fluorescence lifetime measurements ranging ranging to 30 ns. We judge this method to provide more reliable lifetime measurements by the phase and modulation method. The test solutions and procedures we describe may be used by other laboratories to evaluate the performance of their phase fluorometers.  相似文献   

16.
The aim of this study was to determine the effects of the single intake of a high-energy and high-fat meal, of that of a moderate-energy and high-carbohydrate meal, and of fasting, which are major global eating patterns involving the combination of various levels of energy and nutrients, on heart rate variability in healthy young males. Participants were assigned to three groups: the high-energy and high-fat meal group, the moderate-energy and high-carbohydrate meal group, and the fasting group (no meal) in a randomized crossover design. The R-R intervals were continuously recorded before and after meals. Physiological and psychological data were obtained before and 30, 60, 90, and 120 min after meal intake. The main results were: (1) decreased sympathetic modulation of the heart and increased parasympathetic modulation of the heart in the fasting group, indicated by an unchanged heart rate, a decreased lowfrequency/high-frequency ratio, and increased high-frequency power of heart rate variability in the fasting group; (2) cardiac sympathetic activation or parasympathetic withdrawal after the intake of either a high-energy and high-fat meal or a moderate-energy and high-carbohydrate meal, indicated by increases in the heart rate and the low-frequency/high-frequency ratio of heart rate variability, and a decrease in the high-frequency power of heart rate variability in both the high-energy and high-fat meal group and the moderate-energy and high-carbohydrate meal group; and (3) the high-energy and high-fat meal group and the moderate-energy and high-carbohydrate meal group showed similar movement in physiological and psychological measurements after the meal intake. In conclusion, the intake of the high-energy and high-fat meal and the moderate-energy and high-carbohydrate meal similarly activated sympathetic modulation of the heart, whereas fasting suppressed sympathetic modulation of the heart compared with the other two eating groups in healthy young males.  相似文献   

17.
To investigate fluorescence lifetime spectroscopy in tissue-like scattering, measurements of phase modulation as a function of modulation frequency were made using two fluorescent dyes exhibiting single exponential decay kinetics in a 2% intralipid solution. To experimentally simulate fluorescence multiexponential decay kinetics, we varied the concentration ratios of the two dyes, 3,3-diethylthiatricarbocyanine iodide and indocynanine green (ICG), which exhibit distinctly different lifetimes of 1.33 and 0.57 ns, respectively. The experimental results were then compared with values predicted using the optical diffusion equation incorporating 1) biexponential decay, 2) average of the biexponential decay, as well as 3) stretched exponential decay kinetic models to describe kinetics owing to independent and quenched relaxation of the two dyes. Our results show that while all kinetic models could describe phase-modulation data in nonscattering solution, when incorporated into the diffusion equation, the kinetic parameters failed to likewise predict phase-modulation data in scattering solutions. We attribute the results to the insensitivity of phase-modulation measurements in nonscattering solutions and the inaccuracy of the derived kinetic parameters. Our results suggest the high sensitivity of phase-modulation measurements in scattering solutions may provide greater opportunities for fluorescence lifetime spectroscopy.  相似文献   

18.
We demonstrate that the sub-millisecond protein folding process referred to as "collapse" actually consists of at least two separate processes. We observe the UV fluorescence spectrum from naturally occurring tryptophans in three well-studied proteins, cytochrome c, apomyoglobin, and lysozyme, as a function of time in a microfluidic mixer with a dead time of approximately 20 mus. Single value decomposition of the time-dependent spectra reveal two separate processes: 1), a spectral shift which occurs within the mixing time; and 2), a fluorescence decay occurring between approximately 100 and 300 micros. We attribute the first process to hydrophobic collapse and the second process to the formation of the first native tertiary contacts.  相似文献   

19.
Analysis of fluorescence decay data for probes incorporated into model or biological membranes invariably requires fitting to more than one decay time even though the same probe exhibits nearly single-exponential decay in solution. The parinaric acids (cis and trans) are examples of this. Data are presented for both parinaric acid isomers in dimyristoylphosphatidylcholine membranes collected to higher precision than normally encountered, and the fluorescence decays are shown to be best described by a smooth distribution of decay times rather than by a few discrete lifetimes. The temperature dependence of the fluorescence decay reveals a clear shift in the distribution to longer lifetimes associated with the membrane phase transition at 23.5 degrees C. The physical significance is that fluorescence lifetime measurements appear to reflect a physical process with a distribution of lifetimes rather than several distinct physical processes.  相似文献   

20.
Theory is presented for the analysis of excited-state reactions by fluorescence phase shift and demodulation methods. Initially, a two-state model with spectral overlap is considered to illustrate most simply the effects of excited-state reactions on the expected phase and modulation values. Secondly, a multistate model is described to illustrate the probable effects of a fluorophore interacting with several solvent molecules. We note the following unique features of phase-modulation data expected from a fluorophore whose emission spectrum shifts during the lifetime of the excited state: (1) The modulation frequency dependence of the apparent phase (τp) and modulation (τm) lifetimes of the reacted species is opposite to that of a heterogeneous population of fluorophores. (2) For the reacted species τp > τm. For a heterogeneous sample τp < τm. (3) The phase angle of the reacted species can exceed 90°. For a heterogeneous sample phase angles are always less than 90°. Thus, phase and modulation measurements can distinguish between time-dependent processes and spectral heterogeneity by observation of any feature described above. Additionally: (4) The lifetime of the product species can be measured directly. (5) Reverse relaxation can be identified, and the reverse relaxation rates calculated. (6) The wavelength-dependent phase and modulation data can be used to resolve the individual spectra from a two-state reaction. (7) And finally, under favorable conditions, a two-state excited-stale process can be distinguished from a continuous multiple-state process. In each instance, model calculations are presented to illustrate the unique potentials of phase-modulation fluorometry for investigations of excited-state processes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号