首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Nanographene-based tyrosinase biosensor for rapid detection of bisphenol A   总被引:1,自引:0,他引:1  
Hydrophilic nanographene (NGP) prepared by ball milling of graphite was used as the support to construct a novel tyrosinase biosensor for determination of bisphenol A (BPA). The performances of the nanographene-based tyrosinase biosensor were systematically compared with those of multiwall carbon nanotubes (MWNTs) modified tyrosinase biosensors. The results indicated that the nanographene-based tyrosinase biosensor provided significant advantages over MWNTs-based tyrosinase biosensor in term of response, repeatability, background current and limit of detection (LOD), which could be attributed to its larger specific surface area and unique hierarchical tyrosinase-NGP nanostructures. The nanographene-based tyrosinase biosensor displayed superior analytical performance over a linear range from 100 nmol L(-1) to 2000 nmol L(-1), with LOD of 33 nmol L(-1) and sensitivity of 3108.4 mA cm(-2)M(-1). The biosensor was further used for detecting BPA (leaching from different vessels) in tap water, and the accuracy of the results was validated by high performance liquid chromatography (HPLC). The nanographene-based tyrosinase biosensor proved to be a promising and reliable tool for rapid detection of BPA leached from polycarbonate plastic products and for on-site rapid analysis of emergency pollution affairs of BPA.  相似文献   

2.
An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parathion to p-nitrophenol. The later is detected anodically at the carbon transducer with the oxidation current being proportional to the nerve-agent concentration. The sensor sensitivity was optimized with respect to the buffer pH and loading of cells immobilized using paraoxon as substrate. The best sensitivity was obtained using a sensor constructed with 10 mg of wet cell weight per 100 mg of carbon paste and operating in pH 8.5 buffer. Using these conditions, the biosensor was used to measure as low as 0.2 microM paraoxon and 1 microM methyl parathion with very good sensitivity, excellent selectivity and reproducibility. The microbial biosensor had excellent storage stability, retaining 100% of its original activity when stored at 4 degrees C for up to 45 days.  相似文献   

3.
A novel amperometric biosensor, based on electrodeposition of platinum nanoparticles onto multi-walled carbon nanotube (MWNTs) and immobilizing enzyme with chitosan-SiO(2) sol-gel, is presented in this article. MWNTs were cast on the glass carbon (GC) substrate directly. An extra Nafion coating was used to eliminate common interferents such as acetaminophen and ascorbic acids. The morphologies and electrochemical performance of the modified electrodes have been investigated by scanning electron microscopy (SEM) and amperometric methods, respectively. The synergistic action of Pt and MWNTs and the biocompatibility of chitosan-SiO(2) sol-gel made the biosensor have excellent electrocatalytic activity and high stability. The resulting biosensor exhibits good response performance to glucose with a wide linear range from 1 microM to 23 mM and a low detection limit 1 microM. The biosensor also shows a short response time (within 5s), and a high sensitivity (58.9 microAm M(-1)cm(-2)). In addition, effects of pH value, applied potential, rotating rate, electrode construction and electroactive interferents on the amperometric response of the sensor were investigated and discussed in detail.  相似文献   

4.
A sensitive, selective and stable amperometric glucose biosensor employing novel PtPd bimetallic nanoparticles decorated on multi-walled carbon nanotubes (PtPd-MWCNTs) was investigated. PtPd-MWCNTs were prepared by a modified Watanabe method, and characterized by XRD and TEM. The biosensor was constructed by immobilizing the PtPd-MWCNTs catalysts in a Nafion film on a glassy carbon electrode. An inner Na?on film coating was used to eliminate common interferents such as uric acid, ascorbic acid and fructose. Finally, a highly porous surface with an orderly three-dimensional network enzyme layer (CS-GA-GOx) was fabricated by electrodeposition. The resulting biosensor exhibited a good response to glucose with a wide linear range (0.062-14.07 mM) and a low detection limit 0.031 mM. The biosensor also showed a short response time (within 5 s), and a high sensitivity (112 μA mM(-1)cm(-2)). The Michaelis-Menten constant (K(m)) was determined as 3.3 mM. In addition, the biosensor exhibited high reproducibility, good storage stability and satisfactory anti-interference ability. The applicability of the biosensor to actual serum sample analysis was also evaluated.  相似文献   

5.
Dopamine, the most important neurotransmitter in the human brain, controls various functions. Dopamine deficiency causes fatal neurological disorders such as Parkinson’s disease. Even though various types of electrochemical sensors have been studied to measure dopamine levels, they often have poor selectivity for dopamine due to co-existence of interfering substances (e.g. ascorbic acid). Herein, we aimed to develop a highly sensitive dopamine detection method in the co-existence of ascorbic acid, a major interfering substance in real sample by designing an electrochemically pretreated and activated carbon/tyrosinase/Nafion®-modified GCE as an amperometric dopamine biosensor. To maximize the biosensor performance, pH, volume of Nafion®, and scan rate were optimized. This electrochemically pretreated and activated carbon/tyrosinase/ Nafion®-modified GCE could detect as low as 50 μM of dopamine with a wide linear range (50 ~ 1,000 μM) within a few seconds. In addition, it had a sensitivity of 103mAM/cm2, which was higher than all previously reported tyrosinasebased dopamine biosensors. In addition, interference effect caused by 4 mM of ascorbic acid was negligible in the co-existence of 1 mM of dopamine. Consequently, this electrochemically pretreated and activated carbon/tyrosinase/ Nafion®-modified GCE might be applicable as amperometric biosensor for selective detection of dopamine in real samples with interfering substances.  相似文献   

6.
An amperometric microbial biosensor for highly specific, sensitive and rapid quantitative determination of p-nitrophenol was developed. The biosensor takes advantage of the ability of Moraxella sp. to specifically degrade p-nitrophenol to hydroquinone, a more electroactive compound than p-nitrophenol. The electrochemical oxidation current of hydroquinone formed in biodegradation of p-nitrophenol was measured at Moraxella sp.-modified carbon paste electrode and correlated to p-phenol concentrations. The optimum response was realized by electrode constructed using 15 mg of dry cell weight per 1 g of carbon paste and operating at 0.3 V (versus Ag/AgCl reference) in pH 7.5, 20 mM sodium phosphate buffer. Operating at these optimum conditions the biosensor had excellent selectivity against phenol derivatives and was able to measure as low as 20 nM (2.78 ppb) p-nitrophenol with very good accuracy and reproducibility. The biosensor was stable for approximately 3 weeks when stored at 4 degrees C. The applicability of the biosensor to measure p-nitrophenol in lake water was demonstrated.  相似文献   

7.
A novel polyaniline-ionic liquid-carbon nanofiber (PANI-IL-CNF) composite was greenly prepared by in situ one-step electropolymerization of aniline in the presence of IL and CNF for fabrication of amperometric biosensors. The scanning electron micrographs confirmed that the PANI uniformly grew along with the structure of CNF and the PANI-IL-CNF composite film showed a fibrillar morphology with the diameter of around 95 nm. A phenol biosensor was constructed by immobilizing tyrosinase on the surface of the composite modified glassy carbon electrode via the cross-linking step with glutaraldehyde. The biosensor exhibited a wide linear response to catechol ranging from 4.0 x 10(-10) to 2.1 x 10(-6)M with a high sensitivity of 296+/-4 AM(-1)cm(-2), a limit of detection down to 0.1 nM at the signal to noise ratio of 3 and applied potential of -0.05 V. According to the Arrhenius equation, the activation energy for enzymatic reaction was calculated to be 38.8 kJmol(-1) using catechol as the substrate. The apparent Michaelis-Menten constants of the enzyme electrode were estimated to be 1.44, 1.33, 1.16, 0.65 microM for catechol, p-cresol, phenol, m-cresol, respectively. The functionalization of CNF with PANI in IL provided good biocompatible platform for biosensing and biocatalysis.  相似文献   

8.
A novel amperometric biosensor for hydrogen peroxide (H(2)O(2)) was developed by entrapping horseradish peroxidase (HRP) in a new ormosil composite doped with ferrocene monocarboxylic acid-bovine serum albumin conjugate and multiwall carbon nanotubes (MWNTs). The ormosil was prepared using 3-(aminopropyl)triethoxysilane and 2-(3,4 epoxycyclohexyl)-ethyltrimethoxy silane as monomers. The encapsulated conjugate showed excellent electrochemistry and acted as an electron transfer mediator. The presence of MWNTs improved the conductivity of the composite film. This matrix showed a biocompatible microenvironment for retaining the native activity of the entrapped HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H(2)O(2). The proposed H(2)O(2) biosensor exhibited a linear range of 0.02-4.0 mM with a detection limit of 5.0 microM (S/N = 3) and a K(M)(app) value of 2.0 mM. It could be used for flow injection analysis of hydrogen peroxide with a liner range from 0.02 to 4.5 mM, sensitivity of 0.042 microA/mM and analytical time of 20 s per sample. This biosensor possessed good analytical performance and storage stability.  相似文献   

9.
A bienzymatic glucose biosensor was proposed for selective and sensitive detection of glucose. This mediatorless biosensor was made by simultaneous immobilization of glucose oxidase (GOD) and horseradish peroxidase (HRP) in an electropolymerized pyrrole (PPy) film on a single-wall carbon nanotubes (SWNT) coated electrode. The amperometric detection of glucose was assayed by potentiostating the bienzymatic electrode at -0.1 versus Ag/AgCl to reduce the enzymatically produced H(2)O(2) with minimal interference from the coexisting electroactive compounds. The single-wall carbon nanotubes, sandwiched between the enzyme loading polypyrrole (PPy) layer and the conducting substrate (gold electrode), could efficiently promote the direct electron transfer of HRP. Operational characteristics of the bienzymatic sensor, in terms of linear range, detection limit, sensitivity, selectivity and stability, were presented in detail.  相似文献   

10.
In this work the sensitivity-increasing effect of single-walled carbon nanotubes (SWCNTs) in amperometric biosensors, depending on their average length distribution, was studied. For this purpose the SWCNTs were oxidatively shortened and subsequently length separated by size exclusion chromatography. Transmission electron micrographs of different fractions of SWCNTs were collected. Diaphorase "wired" to an osmium redox polymer was blended with the shortened SWCNTs of different lengths. Depending on the average length of the SWCNTs the sensitivity of the amperometric biosensor model system towards oxidation of 1,4-dihydronicotinamide adenine dinucleotide (NADH) was increased by a factor of five. The best performance was achieved with SWCNTs of medium length. The linear range for NADH detection was between 5muM and 7mM, the maximum sensitivity was 47nAmuM(-1)cm(-2), and the detection limit was 1muM. The biosensor exhibited excellent electrocatalytic properties. Even at relatively high NADH concentrations the oxidative current was limited by the diffusion rate of NADH.  相似文献   

11.
The properties of amperometric biosensors based on methanol dehydrogenase (MDH) Methylobacterium nodulans, cells, and the ferrocene-modified carbon paste electrode were investigated. It was shown that the addition of hydroxyapatite (HA) to a carbon paste increased the sensitivity and operating stability of MDH biosensors. The linear range of the electrode was 0.0135–0.5 and 0.032–1.5 mM for methanol and formaldehyde, respectively. The detection limit of methanol and formaldehyde was 4.5 and 11.0 μM, respectively. The loss of activity of the electrode within 10 days of storage in the presence of 2.0 mM KCN did not exceed 12%. Cyanide (10 mM) completely inhibited the sensor responses to formaldehyde (1.0 mM), which allowed for the selective determination of methanol in the presence of formaldehyde. The biosensor based on cells exhibited lower stability and sensitivity toward methanol and formaldehyde; the sensitivity coefficients were 980 and 21 nA/mM, respectively.  相似文献   

12.
A NADH and glucose biosensor based on thionine cross-linked multiwalled carbon nanotubes (MWNTs) and Au nanoparticles (Au NPs) multilayer functionalized indium-doped tin oxide (ITO) electrode were presented in this paper. The effect of light irradiation on the enhancement of bioelectrocatalytic processes of the biocatalytic systems by the photovoltaic effect was investigated. This bioelectrode exhibited excellent catalytic activity of the oxidation towards dihydronicotinamide adenine dinucleotide (NADH). Most interesting, the performance of this NADH sensor could be tuned by the visible light. When the biosensor was performed in the dark, the anodic current increased linearly with NADH concentration over the range from 0.5 to 237 microM with detection limit 0.1 microM and sensitivity 17 nA microM(-1). The sensitivity became 115 nA microM(-1) with detection limit 0.05 microM with the light irradiation. Compared with the reaction in dark, the sensitivity increased around 7 folds while the detection limit decreased 2 folds. The glucose biosensor also exhibited the same behavior. The linear range was from 10 microM to 2.56 mM with the sensitivity of 7.8 microAmM(-1) and detection limit 5.0 microM in the dark. After the light irradiation, the linear range was from 1 microM to 3.25 mM with the sensitivity of 18.5 microA mM(-1) and detection limit 0.7 microM. It indicated a potential to provide an operational access to develop new kinds of photocontrolled dehydrogenase enzyme-based bioelectronics.  相似文献   

13.
Zou Y  Sun LX  Xu F 《Biosensors & bioelectronics》2007,22(11):2669-2674
In this work, a novel route for fabrication polyaniline (PANI)-Prussian Blue (PB) hybrid composites is proposed by the spontaneous redox reaction in the FeCl(3)-K(3)[Fe(CN)(6)] and the aniline solution. With the introduction of multi-walled carbon nanotubes (MWNTs), the PANI-PB/MWNTs system shows synergy between the PANI-PB and MWNTs which amplified the H(2)O(2) sensitivity greatly. A linear range from 8 x1 0(-8) to 1 x 10(-5)M and a high sensitivity 508.1 8 microA microM cm(2) for H(2)O(2) detection are obtained. The composites also show good stability in neutral solution. A glucose biosensor was further constructed by immobilizing glucose oxidase (GOD) with Nafion and glutaraldehyde on the electrode surface. The performance factors influencing the resulted biosensor were studied in detail. The biosensor exhibits excellent response performance to glucose with the linear range from 1 to 11 mM and a detection limit of 0.01 mM. Furthermore, the biosensor shows rapid response, high sensitivity, good reproducibility, long-term stability and freedom of interference from other co-existing electroactive species.  相似文献   

14.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.  相似文献   

15.
A rapid and highly sensitive miniaturized amperometric biosensor for the detection of α-ketoglutarate (α-KG) based on a carbon fiber electrode (CFE) is presented. The biosensor is constructed by immobilizing the enzyme, glutamate dehydrogenase (GLUD) on the surface of single carbon fiber modified by co-deposition of ruthenium (Ru) and rhodium (Rh) nanoparticles. SEM and EDX shed useful insights into the morphology and composition of the modified microelectrode. The mixed Ru/Rh coating offers a greatly enhanced electrocatalytic activity towards the detection of β-nicotinamide adenine dinucleotide (NADH), with a substantial decrease in overpotential of ~ 400 mV compared to the unmodified CFE. It also imparts higher stability with minimal surface fouling, common to NADH oxidation. Further modification with the enzyme, GLUD leads to effective amperometric biosensing of α-KG through monitoring of the NADH consumption. A very rapid response to dynamic changes in the α-KG concentrations is observed with a response time of 6s. The current response is linear between 100 and 600 μM with a sensitivity of 42 μAM(-1) and a detection limit of 20 μM. This proof of concept study indicates that the GLUD-Ru/Rh-CFE biosensor holds great promise for real-time electrochemical measurements of α-KG.  相似文献   

16.
In this article, we describe a third-generation amperometric glucose biosensor working under physiological conditions. This glucose biosensor consists of a recently discovered cellobiose dehydrogenase from the ascomycete Corynascus thermophilus (CtCDH) immobilized on different commercially available screen-printed electrodes made of carbon (SPCEs), carboxyl-functionalized single-walled carbon nanotubes (SPCE-SWCNTs), or multiwalled carbon nanotubes (SPCE-MWCNTs) by simple physical adsorption or a combination of adsorption followed by cross-linking using poly(ethyleneglycol) (400) diglycidyl ether (PEGDGE) or glutaraldehyde (GA). The CtCDH-based third-generation glucose biosensor has a linear range between 0.025 and 30 mM and a detection limit of 10 μM glucose. Biosensors based on SWCNTs showed a higher sensitivity and catalytic response than the ones functionalized with MWCNTs and the SPCEs. A drastic increase in response was observed for all three electrodes when the adsorbed enzyme was cross-linked with PEGDGE or GA. The operational stability of the biosensor was tested for 7 h by repeated injections of 50 mM glucose, and only a slight decrease in the electrochemical response was found. The selectivity of the CtCDH-based biosensor was tested on other potentially interfering carbohydrates such as mannose, galactose, sucrose, and fucose that might be present in blood. No significant analytical response from any of these compounds was observed.  相似文献   

17.
A novel acetylcholinesterase (AChE)/choline oxidase (ChOx) bienzyme amperometric acetylcholine biosensor based on gold nanoparticles (AuNPs) and multi-walled carbon nanotubes (MWCNTs) has been successfully developed by self-assembly process in combination of sol-gel technique. A thiolated aqueous silica sol containing MWCNTs and ChOx was first dropped on the surface of a cleaned Pt electrode, and then AuNPs were assembled with the thiolated sol-gel network. Finally, the alternate deposition of poly (diallyldimethylammonium chloride) (PDDA) and AChE was repeated to assemble different layers of PDDA-AChE on the electrode for optimizing AChE loading. Among the resulting biosensors, the biosensor based on two layers of PDDA-AChE multilayer films showed the best performance. It exhibited a wide linear range, high sensitivity and fast amperometric response, which were 0.005-0.4mM, 3.395 μA/mM, and within 15s, respectively. The biosensor showed long-term stability and acceptable reproducibility. More importantly, this study could provide a simple and effective multienzyme immobilization platform for meeting the demand of the effective immobilization enzyme on the electrode surface.  相似文献   

18.
A novel amperometric phenol sensor was constructed by immobilizing tyrosinase in a titania sol-gel matrix. The tyrosinase entrapped sol-gel film was obtained with a vapor deposition method, which simplified the traditional sol-gel process and avoided the shrinkage and cracking of conventional sol-gel-derived glasses. This matrix provided a microenvironment for retaining the native structure and activity of the entrapped enzyme and a very low mass transport barrier to the enzyme substrates. Phenol could be oxidized by dissolving oxygen in presence of immobilized tyrosinase to form a detectable product, which was determined at -150 mV without any mediator. The phenol sensor exhibited a fast response (less than 5 s) and sensitivity as high as 103 microA/mM, which resulted from the porous structure and high enzyme loading of the sol-gel matrix. The linear range for phenol determination was from 1.2x10(-7) to 2.6x10(-4) M with a detection limit of 1.0x10(-7) M. The apparent Michaelis-Menten constant of the encapsulated tyrosinase was calculated to be (0.29+/-0.02) mM. The stability of the biosensor was also evaluated.  相似文献   

19.
A nanobiocomposite film consisted of polypyrrole (PPy), functionalized multiwalled carbon nanotubes (cMWNTs), and glucose oxidase (GOx) were electrochemically synthesized by electrooxidation of 0.1M pyrrole in aqueous solution containing appropriate amounts of cMWNTs and GOx. Potentiostatic growth profiles indicate that the anionic cMWNTs is incorporated within the growing PPy-cMWNTs nanocomposite for maintaining its electrical neutrality. The morphology of the PPy-cMWNTs nanocomposite was characterized by scanning electron microscopy (SEM). The PPy-cMWNTs nanocomposite was deposited homogeneously onto glassy carbon electrode. The amperometric responses vary proportionately to the concentration of hydrogen peroxide at the PPy-cMWNTs nanocomposite modified electrode at an operating potential of 0.7V versus Ag/AgCl (3M). The results indicate that the electroanalytical PPy-cMWNTs-GOx nanobiocomposite film was highly sensitive and suitable for glucose biosensor based on GOx function. The GOx concentration within the PPy-cMWNTs-GOx nanobiocomposite and the film thickness are crucial for the performance of the glucose biosensor. The amperometric responses of the optimized PPy-cMWNTs-GOx glucose biosensor (1.5 mgmL(-1) GOx, 141 mCcm(-2) total charge) displayed a sensitivity of 95 nAmM(-1), a linear range up to 4mM, and a response time of about 8s.  相似文献   

20.
An electrochemical biosensor based on a glassy carbon (GC) electrode chemically modified with the perfluorinated cation-exchange polymer Nafion and methyl viologen (MV) is described. The enzyme was immobilized by cross-linking with glutaraldehyde in the presence of bovine serum albumin (BSA), methyl viologen and Nafion. Operating variables such as the enzyme/BSA ratio, cross-linking time in glutaraldehyde vapor, methyl viologen and Nafion percentages were investigated with regard to their influence on the biosensor sensitivity by using glucose oxidase as the enzyme model due to its high stability and low cost. The glutamate biosensor was elaborated by using optimized parameters and its electrochemical properties were investigated by cyclic voltammetry, amperometry and by electrochemical impedance spectroscopy. The glutamate biosensor shows a detection limit of 20 microM and a linear range extended to 0.75 mM. Its selectivity was tested with 15 different amino acids, each with a concentration of 20 microM, 25 microM acetaminophen, 20 microM uric acid and 200 microM ascorbic acid. No amperometric response was observed for the interfering species. This good selectivity allows glutamate detection in biological media without previous separation of the analyte.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号