 共查询到20条相似文献,搜索用时 15 毫秒
1.
The mechanical environment around the healing of broken bone is very important as it determines the way the fracture will heal. Over the past decade there has been great clinical interest in improving bone healing by altering the mechanical environment through the fixation stability around the lesion. One constraint of preclinical animal research in this area is the lack of experimental control over the local mechanical environment within a large segmental defect as well as osteotomies as they heal. In this paper we report on the design and use of an external fixator to study the healing of large segmental bone defects or osteotomies. This device not only allows for controlled axial stiffness on the bone lesion as it heals, but it also enables the change of stiffness during the healing process in vivo. The conducted experiments have shown that the fixators were able to maintain a 5 mm femoral defect gap in rats in vivo during unrestricted cage activity for at least 8 weeks. Likewise, we observed no distortion or infections, including pin infections during the entire healing period. These results demonstrate that our newly developed external fixator was able to achieve reproducible and standardized stabilization, and the alteration of the mechanical environment of in vivo rat large bone defects and various size osteotomies. This confirms that the external fixation device is well suited for preclinical research investigations using a rat model in the field of bone regeneration and repair.  相似文献   

2.
Good mechanical fixation of an implant to the surrounding bone is important for its longevity, and is influenced by both biological and mechanical factors. This study parametrically evaluates the mechanics of the interface with a computationally efficient analytic structural model of the shear stress field and global shear stiffness of an axially loaded implant. The utility of the analytic model was first established by validating its assumptions with a case-specific finite element model. We then used the analytic model for a sensitivity analysis of the relationship between the pattern of tissue growth and shear properties of the interface for our previously reported loaded in vivo experimental micromotion device. The bone located directly at the implant surface was found to be the most effective site for increasing interface stiffness. This suggests that the implant surface is the most desirable site for bone growth, yet is also the most mechanically challenging environment due to its maximal shear stresses. Thus, these findings support the further investigation of osteo-conductive coatings and other biological stimuli to overcome the challenging mechanics, and to promote bone growth directly at the implant surface. The model also demonstrated that the mechanical contribution to the global implant shear stiffness of a commonly observed isolated sclerotic bone rim is very limited. The results of this sensitivity analysis agree with experimental studies with the micromotion device, and with clinical studies reporting good results with osteo-conductive coatings.  相似文献   

3.
Different fixation systems are used for fracture and defect treatment. A prerequisite for complication free healing is sufficient mechanical stability of the osteosynthesis. In vitro investigations offer the possibility of both analysing and assessing the pre-clinical fixation stability. Due to the complex loading environment in vivo, stiffness analysis should include a complete determination of the stiffness under standardised conditions. Based on a mathematical procedure to calculate the 3-D stiffness, a mechanical testing device for the 3-D loading of fixation systems was designed and integrated in the existing test set-up. The set-up consisted of a material testing machine to produce the necessary loads and an optical measurement device to detect the resulting inter-fragmentary movements. To validate the testing device, the 3-D stiffness matrices of different Ilizarov fixator configurations were determined and compared. The good reproducibility of the test was reflected in the small intra-individual variability of the stiffness components. A distinct direction dependence of the fixator stiffness was observed. Increasing the number of rings led to a stiffness increase of up to 50%, especially in bending. The presented testing device allows a complete standardised determination of the stiffness of different fixation systems. It considers the direction dependence of the stiffness and creates a prerequisite for a more direct implant comparison.  相似文献   

4.
There is little information about the influence of bone graft size, position and elasticity on the mechanical behavior of the lumbar spine. Intersegmental motion, intradiscal pressure and stresses in the lumbar spine were calculated using a three-dimensional, nonlinear finite element model which included an internal spinal fixation device and a bone graft. Cross-sectional area, position, and elastic modulus of the graft were varied in this study. Bone grafts, especially very stiff ones, increase stresses on adjacent endplates. Though larger grafts lead to less contact pressure, it is difficult to judge the quality of different bone graft positions. In general, ventral flexion results in lower maximum contact pressure than lateral bending. There is always little intersegmental rotation in the bridged region compared with that of an intact spine.A larger graft with low stiffness should be favored from a mechanical point of view. Patients should avoid lateral bending of the upper body shortly after surgery.  相似文献   

5.
This study was directed to the measurement of the mechanical response of fetal membranes to physiologically relevant loading conditions. Characteristic mechanical parameters were determined and their relation to the microstructural constituents collagen and elastin as well as to the pyridinium cross-link concentrations analyzed. 51 samples from twelve fetal membranes were tested on a custom-built inflation device, which allows mechanical characterization within a multiaxial state of stress. Methods of nonlinear continuum mechanics were used to extract representative mechanical parameters. Established biochemical assays were applied for the determination of the collagen and elastin content. Collagen cross-link concentrations were determined by high-performance liquid chromatography measurements. The results indicate a distinct correlation between the mechanical parameters of high stretch stiffness and membrane tension at rupture and the biochemical data of collagen content and pyridinoline as well as deoxypyridinoline concentrations. No correlation was observed between the mechanical parameters and the elastin content. Moreover, the low stretch stiffness is, with a value of 105 ± 31 × 10?3 N/ mm much higher for a biaxial state of stress compared to a uniaxial stress configuration. Determination of constitutive model equations leads to better predictive capabilities for a reduced polynomial hyperelastic model with only terms related to the second invariant, I 2, of the right Cauchy-Green deformation tensor. Relevant insights were obtained on the mechanical behavior of fetal membranes. Collagen and its cross-linking were shown to determine membrane’s stiffness and strength for multiaxial stress states. Their nonlinear deformation behavior characterizes the fetal membranes as I 2 material.  相似文献   

6.
Segmental bone defect animal models are often used for evaluating the bone regeneration performance of bone substituting biomaterials. Since bone regeneration is dependent on mechanical loading, it is important to determine mechanical load transfer after stabilization of the defect and to study the effects of biomaterial stiffness on the transmitted load. In this study, we assess the mechanical load transmitted over a 6 mm femur defect that is stabilized with an internal PEEK fixation plate. Subsequently, three types of selective laser melted porous titanium implants with different stiffness values were used to graft the defect (five specimens per group). In one additional group, the defect was left empty. Micro strain gauges were used to measure strain values at four different locations of the fixation plate during external loading on the femoral head. The load sharing between the fixation plate and titanium implant was highly variable with standard deviations of measured strain values between 31 and 93% of the mean values. As a consequence, no significant differences were measured between the forces transmitted through the titanium implants with different elastic moduli. Only some non-significant trends were observed in the mean strain values that, consistent with the results of a previous finite element study, implied the force transmitted through the implant increases with the implant stiffness. The applied internal fixation method does not standardize mechanical loading over the defect to enable detecting small differences in bone regeneration performances of bone substituting biomaterials. In conclusion, the fixation method requires further optimization to reduce the effects of the operative procedure and make the mechanical loading more consistent and improve the overall sensitivity of this rat femur defect model.  相似文献   

7.
BACKGROUND AND PURPOSE: Use of rabbits in orthopedic investigations is common. In this study, focus is on factors that influence bone healing and on distraction osteogenesis. Biomechanical characteristics of two external fixator systems (Orthofix device and Hoffmann device) for long bones were tested. METHODS: Twelve freshly dissected tibiae were obtained from six skeletally mature New Zealand White rabbits, and four-point bending stiffness in two planes (90 and 180 degrees to the fixator pins) and torsional stiffness and strength of the bone-fixator complex were evaluated by use of a material testing machine. RESULTS: In four-point bending, Orthofix device had higher stiffness and strength, compared with Hoffmann device. When the load was applied 180 degrees to the pins, both devices had higher stiffness, compared with that at 90 degrees. In torsional testing, Orthofix device had significantly higher stiffness and strength. CONCLUSIONS: Significant differences in structural properties between the two systems were evident. Loading direction and gap conditions were important factors in determining properties of the systems. Therefore, type of external fixation system and fixation technique should be considered when designing experiments, using the rabbit long bone model.  相似文献   

8.
Dynamic stabilization devices have been introduced to clinics as an alternative to rigid fixation. The stiffness of these devices varies widely, whereas the optimal stiffness, achieving a predefined stabilization of the spine, is unknown. This study was focused on the determination of stiffness values for posterior stabilization devices achieving a flexible, semi-flexible or rigid connection between two vertebrae.An extensively validated finite element model of a lumbar spinal segment L4-5 with an implanted posterior fixation device was used in this study. The model was exposed to pure moments of 7.5 and 20 Nm around the three principal anatomical directions, simulating flexion, extension, lateral bending and axial rotation. In parametrical studies, the influence of the axial and bending fixator stiffness on the spinal range of motion was investigated. In order to examine the validity of the computed results, an in-vitro study was carried out. In this, the influence of two posterior stabilization devices (DSS? and rigidly internal fixator) on the segmental stabilization was investigated.The finite element (FE)-model predicted that each load direction caused a pairing of stiffness relations between axial and bending stiffness. In flexion and extension, however, the bending stiffness had a neglectable effect on the segmental stabilization, compared to the axial stiffness. In contrast, lateral bending and axial rotation were influenced by both stiffness parameters. Except in axial rotation, the model predictions were in a good agreement with the determined in-vitro data. In axial rotation, the FE-model predicted a stiffer segmental behavior than it was determined in the in-vitro study.It is usually expected that high stiffness values are required for a posterior stabilization device to stiffen a spinal segment. We found that already small stiffness values were sufficient to cause a stiffening. Using these data, it may possible to develop implants for certain clinical indications.  相似文献   

9.
The stiffness of fracture fixation devices together with musculoskeletal loading defines the mechanical environment within a long bone fracture, and can be quantified by the interfragmentary movement. In vivo results suggested that this can have acceleratory or inhibitory influences, depending on direction and magnitude of motion, indicating that some complications in fracture treatment could be avoided by optimizing the fixation stiffness. However, general statements are difficult to make due to the limited number of experimental findings. The aim of this study was therefore to numerically investigate healing outcomes under various combinations of shear and axial fixation stiffness, and to detect the optimal configuration. A calibrated and established numerical model was used to predict fracture healing for numerous combinations of axial and shear fixation stiffness under physiological, superimposed, axial compressive and translational shear loading in sheep. Characteristic maps of healing outcome versus fixation stiffness (axial and shear) were created. The results suggest that delayed healing of 3 mm transversal fracture gaps will occur for highly flexible or very rigid axial fixation, which was corroborated by in vivo findings. The optimal fixation stiffness for ovine long bone fractures was predicted to be 1000–2500 N/mm in the axial and >300 N/mm in the shear direction. In summary, an optimized, moderate axial stiffness together with certain shear stiffness enhances fracture healing processes. The negative influence of one improper stiffness can be compensated by adjustment of the stiffness in the other direction.  相似文献   

10.
Tibial bone defect is a critical problem for revision knee arthroplasty. Instead of using metallic spacer or cement, biodegradable scaffolds could be an alternative solution. A numerical model of a revision knee arthroplasty was thus developed to estimate the mechanical resistance of the scaffold in this demanding situation. The tibia, scaffold, and prosthesis were represented by simplified parameterised geometries. The maximal gait cycle force was applied asymmetrically to simulate a critical loading. Several parameters were analysed: 1) inter-individual variability, 2) cortical bone stiffness, 3) cortical bone thickness, 4) prosthesis fixation quality, and 5) scaffold thickness. The calculated scaffold strain was compared to its experimental ultimate strain. Among the tested parameters, failure was only predicted with scaffold thickness below 5 mm. This study suggests that biodegradable bone scaffolds could be used to fill bone defects in revision knee arthroplasty, but scaffold size seems to be the limiting factor.  相似文献   

11.
The use of hybrid Ilizarov models around femoral area is gaining clinical popularity lately. Hybrid systems show different mechanical properties. The purpose of this report is to examine the stiffness characteristics of the C-arch and half-pins on the hybrid Ilizarov fixators. Eight models that included standard Ilizarov and hybrid models were applied to six femoral sawbones. The distal part of fixation was composed of a two-ring frame applied identically to all bones. The difference of the configuration was at the proximal part, where half-pins with or without C-arches were either added to the proximal two-ring frame or replaced the proximal one- or two-ring frame. Osteotomy was performed in the femoral diaphysis and the bone was distracted 2cm. The stability of the system was tested with the axial compression testing machine. Displacements between the adjacent fracture sides were measured with the video extensometer in three dimensions. We found that proximal half-pin applications alone had less stiffness, but half-pins with C-arch had more stiffness than the model including only half-pins. Additional half-pins onto one- or two-ring frames had more longitudinal stiffness, but this system showed weak resistance against transverse displacement.  相似文献   

12.
The present article describes a newly developed device for the quantitative assessment of torsional in vivo stiffness of regenerating bone under callus distraction. Both the design and function of this device, and its use during bony consolidation are discussed. The device exhibited an accuracy of +/- 18% for stiffness under 0.1 Nm/degree, and +/- 5% stiffness above 0.1 Nm/degree. The average accuracy was +/- 14%. The data scatter for the stiffness measurement ranged between +/- 1.43% and +/- 7.68% (average: +/- 3.99%). The precision of a test machine was between +/- 0.01% and +/- 11.3% (average: +/- 3.65%). The method has the following advantages over existing methods for investigating healing: 1. no need to dismantle the external fixation for measurement; 2. preservation of the bone axis with minimal risk of misalignment during the bone healing process; 3. minimal technical requirements, with easy, noninvasive measurement; 4. no exposure to X-radiation.  相似文献   

13.
目的:齿状突骨折是颈椎的严重损伤,其中大部分需要行前路螺钉内固定术治疗,齿状突的几何参数对螺钉的选择起决定性作用,其骨密度则影响螺钉对骨质的把持力,齿状突固有的生物力学性质对齿状突骨折固定效果进而对骨折愈合有较大影响,基于以上考虑,本课题分析并比较了几何参数、骨密度与生物力学性质的相关性,评价其指导临床应用的意义。方法:将15例经福尔马林浸泡的国人枢椎标本剔除周围软组织,分别测量并分析各个标本的几何参数、骨密度以及扭转刚度、剪切刚度、拉伸刚度等生物力学性质的特点,并比较它们之间的相关性。结果:齿状突为一椭球形结构,难以容纳两枚内固定螺钉,齿状突的几何参数、骨密度和生物力学性质之间没有相关性。结论:临床上在对齿状突骨折采用螺钉内固定前需要了解齿状突的解剖结构并据此选取适当尺寸的螺钉,应根据齿状突基底部的横径选择螺钉的直径,根据基底部到前唇的距离选择螺钉光滑段的长度,根据枢椎高度选择螺钉长度,齿状突的几何参数、骨密度和齿状突的生物力学性质之间并无相关性,并不能根据齿状突几何参数、骨密度来预测其生物力学强度进而预测内固定的初始稳定性。  相似文献   

14.
Surgical treatment of proximal humeral fractures remains challenging in elderly patients, primarily due to insufficient implant fixation. Both bone quality and physiological-like loading conditions are commonly overlooked during pre-clinical in vitro evaluation. However, this knowledge is necessary in order to improve surgical treatment of the proximal humerus and the mechanical behavior of implants, particularly in patients with complex fractures and weak bone stock. We hypothesize that the bone quality has a high influence on the bone straining, independent of the arm position. The goal of this study was to determine the straining of the intact and fractured proximal humerus under physiological-like loading conditions. Furthermore, the impact of augmentation on tissue straining was evaluated.

Two representative humeri were selected for this study, one osteoporotic and one reference quality, and scanned using both QCT and DEXA (average DEXA VALUE=0.26 and 0.49 g/cm2 respectively). Subcaptial defects were generated, then stabilized with a plate prior to mechanical stiffness testing. From the QCT data, finite element models were generated and the in vitro stiffness tests analytically simulated. Under physiological-like loading conditions, the straining of the bone and implant were analyzed for 0°, 90° forward flexion, and 90° abduction.

Maximal strain values were found for the intact and fractured bone at 90° abduction. This study demonstrates that the straining in a fractured bone of poor quality leads to considerably higher bone strains (up to +30%) than in a more healthy bone. Augmentation of a central void under physiological-like loading with commercial cement led to mechanical failure at the bone–cement interface.

New concepts for the surgical treatment of complex fractures of the proximal humerus should take bone distribution into account and thereby allow effective treatment of fractures in osteoporotic patients. The ultimate salvage procedure of augmentation has mechanical limitations as long as current cement materials are used in osteoporotic patients.  相似文献   


15.
The determining factors for the fixation of uncemented screws in bone are the bone-implant interface and the peri-implant bone. The goal of this work was to explore the role of the peri-implant bone architecture on the mechanics of the bone-implant system. In particular, the specific aims of the study were to investigate: (i) the impact of the different architectural parameters, (ii) the effects of disorder, and (iii) the deformations in the peri-implant region. A three-dimensional beam lattice model to describe trabecular bone was developed. Various microstructural features of the lattice were varied in a systematic way. Implant pull-out tests were simulated, and the stiffness and strength of the bone-implant system were computed. The results indicated that the strongest decrease in pull-out strength was obtained by trabecular thinning, whereas pull-out stiffness was mostly affected by trabecular removal. These findings could be explained by investigating the peri-implant deformation field. For small implant displacements, a large amount of trabeculae in the peri-implant region were involved in the load transfer from implant to bone. Therefore, trabecular removal in this region had a strong negative effect on pull-out stiffness. Conversely, at higher displacements, deformations mainly localized in the trabeculae in contact with the implant; hence, thinning those trabeculae produced the strongest decrease in the strength of the system. Although idealized, the current approach is helpful for a mechanical understanding of the role played by peri-implant bone.  相似文献   

16.
Mechanical conditions have a significant influence on the biological processes of bone healing. Small animal models that allow controlling the mechanical environment of fracture and bone defect healing are needed. The aim of this study was to develop a new animal model that allows to reliably control the mechanical environment in fracture and bone defect healing in rats using different implant materials. An external fixator was designed and mounted in vitro to rat femurs using four Kirschner-wires (titanium (T) or steel (S)) of 1.2mm diameter. The specimens were distracted to a gap of 1.5mm. Axial and torsional stiffness of the device was tested increasing the offset (distance between bone and fixator crossbar) from 5 to 15mm. In vivo performance (well-being, infection, breaking of wires and bone healing) was evaluated in four groups of 24 Sprague-Dawley rats varying in offset (7.5 and 15mm) and implant material (S/T) over 6 weeks. Torsional and axial stiffness were higher in steel compared to titanium setups. A decrease in all configurations was observed by increasing the offset. The offset 7.5mm showed a significantly higher torsional (S: p<0.01, T: p<0.001) and axial in vitro stiffness (S: p<0.001, T: p<0.001) compared to 15mm offset of the fixator. Although in vitro designed to be different in mechanical stiffness, no difference was found between the groups regarding complication rate. The overall-complication rate was 5.2%. In conclusion, we were able to establish a small animal model for bone defect healing which allows modeling the mechanical conditions at the defect site in a defined manner.  相似文献   

17.
The menisci are important biomechanical components of the knee. We developed and validated a finite element model of meniscal replacement to assess the effect of surgical fixation technique on contact behavior and knee stability. The geometry of femoral and tibial articular cartilage and menisci was segmented from magnetic resonance images of a normal cadaver knee using MIMICS (Materialise, Leuven, Belgium). A finite element mesh was generated using HyperWorks (Altair Inc, Santa Ana, CA). A finite element solver (Abaqus v6.9, Simulia, Providence, RI) was used to compute contact area and stresses under axial loading and to assess stability (reaction force generated during anteroposterior translation of the femur). The natural and surgical attachments of the meniscal horns and peripheral rim were simulated using springs. After total meniscectomy, femoral contact area decreased by 26% with a concomitant increase in average contact stresses (36%) and peak contact stresses (33%). Replacing the meniscus without suturing the horns did little to restore femoral contact area. Suturing the horns increased contact area and reduced peak contact stresses. Increasing suture stiffness correlated with increased meniscal contact stresses as a greater proportion of tibiofemoral load was transferred to the meniscus. A small incremental benefit was seen of simulated bone plug fixation over the suture construct with the highest stiffness (50 N/mm). Suturing the rim did little to change contact conditions. The nominal anteroposterior stiffness reduced by 3.1 N/mm after meniscectomy. In contrast to contact area and stress, stiffness of the horn fixation sutures had a smaller effect on anteroposterior stability. On the other hand suturing the rim of the meniscus affected anteroposterior stability to a much larger degree. This model emphasizes the importance of the meniscus in knee biomechanics. Appropriate meniscal replacement fixation techniques are likely to be critical to the clinical success of meniscal replacement. While contact conditions are mainly sensitive to meniscus horn fixation, the stability of the knee under anteroposterior shear loads appeared to be more sensitive to meniscal rim fixation. This model may also be useful in predicting the effect of biomaterial mechanical properties and meniscal replacement shape on knee contact conditions.  相似文献   

18.
In this paper, novel designs of porous acetabular cups are created and tested with 3D finite element analysis (FEA). The aim is to develop a porous acetabular cup with low effective radial stiffness of the structure, which will be near to the architectural and mechanical behavior of the natural bone. For the realization of this research, a 3D-scanner technology was used for obtaining a 3D-CAD model of the pelvis bone, a 3D-CAD software for creating a porous acetabular cup, and a 3D-FEA software for virtual testing of a novel design of the porous acetabular cup. The results obtained from this research reveal that a porous acetabular cup from Ti-based alloys with 60 ± 5% porosity has the mechanical behavior and effective radial stiffness (Young’s modulus in radial direction) that meet and exceed the required properties of the natural bone. The virtual testing with 3D-FEA of a novel design with porous structure during the very early stage of the design and the development of orthopedic implants, enables obtaining a new or improved biomedical implant for a relatively short time and reduced price.  相似文献   

19.
In this study, the homogenized anisotropic elastic properties of single bone lamellae are computed using a finite element unit cell method. The resulting stiffness tensor is utilized to calculate indentation moduli for multiple indentation directions in the lamella plane which are then related to nanoindentation experiments. The model accounts for different fibril orientation patterns in the lamellae—the twisted and orthogonal plywood pattern, a 5-sublayer pattern and an X-ray diffraction-based pattern. Three-dimensional sectional views of each pattern facilitate the comparison to transmission electron (TEM) images of real lamella cuts. The model results indicate, that the 5-sublayer- and the X-ray diffraction-based patterns cause the lamellae to have a stiffness maximum between 0° and 45° to the osteon axis. Their in-plane stiffness characteristics are qualitatively matching the experimental findings that report a higher stiffness in the osteon axis than in the circumferential direction. In contrast, lamellae owning the orthogonal or twisted plywood fibril orientation patterns have no preferred stiffness alignment. This work shows that the variety of fibril orientation patterns leads to qualitative and quantitative differences in the lamella elastic mechanical behavior. The study is a step toward a deeper understanding of the structure—mechanical function relationship of bone lamellae.  相似文献   

20.
Numerous experimental fracture healing studies are performed on rats, in which different experimental, mechanical parameters are applied, thereby prohibiting direct comparison between each other. Numerical fracture healing simulation models are able to predict courses of fracture healing and offer support for pre-planning animal experiments and for post-hoc comparison between outcomes of different in vivo studies. The aims of this study are to adapt a pre-existing fracture healing simulation algorithm for sheep and humans to the rat, to corroborate it using the data of numerous different rat experiments, and to provide healing predictions for future rat experiments. First, material properties of different tissue types involved were adjusted by comparing experimentally measured callus stiffness to respective simulated values obtained in three finite element (FE) models. This yielded values for Young’s moduli of cortical bone, woven bone, cartilage, and connective tissue of 15,750 MPa, 1,000 MPa, 5 MPa, and 1 MPa, respectively. Next, thresholds in the underlying mechanoregulatory tissue differentiation rules were calibrated by modifying model parameters so that predicted fracture callus stiffness matched experimental data from a study that used rigid and flexible fixators. This resulted in strain thresholds at higher magnitudes than in models for sheep and humans. The resulting numerical model was then used to simulate numerous fracture healing scenarios from literature, showing a considerable mismatch in only 6 of 21 cases. Based on this corroborated model, a fit curve function was derived which predicts the increase of callus stiffness dependent on bodyweight, fixation stiffness, and fracture gap size. By mathematically predicting the time course of the healing process prior to the animal studies, the data presented in this work provides support for planning new fracture healing experiments in rats. Furthermore, it allows one to transfer and compare new in vivo findings to previously performed studies with differing mechanical parameters.  相似文献   