1.
A method of computation of retention volumes of linear peptides of known composition that contain no more than 25 amino acids in gradient reversed phase HPLC was developed. The method is suitable for various acetonitrile gradient profiles. The calculations were carried out on the basis of a statistical model, the parameters of which were experimental dependences of the retention of individual amino acids on acetonitrile concentration. The method developed was used to predict the chromatographic behavior of 34 peptides in four different acetonitrile gradients. The correlation coefficients between the predicted and experimental retention volumes were more than 0.9, and the average relative error of prediction was less than 15%. The English version of the paper: Russiatn .lournal of Bioorganic Chemistry, 2008, vol. 34, no. 2; see also http://www.maik.ru.  相似文献   

2.
A method for calculating retention volumes of linear peptides with known primary structures and the values of their UV absorption at chosen wavelengths in reversed phase HPLC are described. These parameters are calculated for every peptide on the basis of the contributions of its amino acid residues determining its degree of retention and its UV spectrum. The contribution values are experimentally found from chromatograms of the free amino acids obtained by multiwavelength photometric detection under the conditions of the peptide chromatography. Thirty peptides have been chromatographed for the evaluation of the proposed method, and the correlation coefficients between the calculated and the experimental retention volumes have been found to be 0.95.  相似文献   

3.
A method for calculating retention volumes of linear peptides with known primary structures and the values of their UV absorption at chosen wavelengths in reversed phase HPLC are described. These parameters are calculated for every peptide on the basis of the contributions of its amino acid residues determining its degree of retention and its UV spectrum. The contribution values are experimentally found from chromatograms of the free amino acids obtained by multiwavelength photometric detection under the conditions of the peptide chromatography. Thirty peptides have been chromatographed for the evaluation of the proposed method, and the correlation coefficients between the calculated and the experimental retention volumes have been found to be 0.95.  相似文献   

4.
Oleg V. Krokhin  Vic Spicer 《Proteomics》2016,16(23):2931-2936
The emergence of data‐independent quantitative LC‐MS/MS analysis protocols further highlights the importance of high‐quality reproducible chromatographic procedures. Knowing, controlling and being able to predict the effect of multiple factors that alter peptide RP‐HPLC separation selectivity is critical for successful data collection for the construction of ion libraries. Proteomic researchers have often regarded RP‐HPLC as a “black box”, while vast amount of research on peptide separation is readily available. In addition to obvious parameters, such as the type of ion‐pairing modifier, stationary phase and column temperature, we describe the “mysterious” effects of gradient slope, column size and flow rate on peptide separation selectivity. Retention time variations due to these parameters are governed by the linear solvent strength (LSS) theory on a peptide level by the value of its slope S in the basic LSS equation—a parameter that can be accurately predicted. Thus, the application of shallower gradients, higher flow rates, or smaller columns will each increases the relative retention of peptides with higher S‐values (long species with multiple positively charged groups). Simultaneous changes to these parameters that each drive shifts in separation selectivity in the same direction should be avoided. The unification of terminology represents another pressing issue in this field of applied proteomics that should be addressed to facilitate further progress.  相似文献   

5.
Investigations into the parameters affecting the sensitivity of polarimetric detectors for the determination of enantiomeric excess by achiral HPLC are presented. The results obtained showed that the specific optical rotation of an analyte was highly sensitive to the methanol content of the mobile phase. The purpose of this short communication is to demonstrate that “off-line” optical rotation measurements are a necessary part of the method development process for successful use of polarimetric detectors. Chirality 9:122–125, 1997, © 1997 Wiley-Liss, Inc.  相似文献   

6.
反相高效液相色谱在发酵制备琥珀酸中的应用   总被引:19,自引:2,他引:19  
对于生物法制备琥珀酸的微生物发酵体系,利用Alltech反相Prevail C18色谱柱,以25mmol/L磷酸二氢钾(pH2.5)作为流动相,在流速1mL/min时,于210nm处紫外检测器检测,能将发酵液中琥珀酸、甲酸、乙酸和乳酸完全分离并准确定量。琥珀酸等有机酸的回收率在96%~104%之间。本方法能够快速、精确测定发酵样品中主产物琥珀酸与其它有机酸含量。  相似文献   

7.
8.
9.
Unquestionably, the purification of polypeptides by chromatographic methods is a considerable bottleneck in their preparation. Peptides synthesised by solid phase synthesis typically contain chromatographically similar impurities that complicate purification by reversed phase high performance liquid chromatography (HPLC) techniques. We report on the application of a slow gradient HPLC protocol that allows, in a single chromatographic step, the purification of hundreds of milligrammes of material. This technique was applied to an extensive collection of synthetic polypeptides some incorporating non‐proteinogenic functionality. In all cases examined, the peptides were not only obtained in high purity peptides but were also recovered in multi‐milligramme amounts. Copyright © 2012 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

10.
Prediction of lipoprotein signal peptides in Gram-negative bacteria   总被引:41,自引:0,他引:41  
A method to predict lipoprotein signal peptides in Gram-negative Eubacteria, LipoP, has been developed. The hidden Markov model (HMM) was able to distinguish between lipoproteins (SPaseII-cleaved proteins), SPaseI-cleaved proteins, cytoplasmic proteins, and transmembrane proteins. This predictor was able to predict 96.8% of the lipoproteins correctly with only 0.3% false positives in a set of SPaseI-cleaved, cytoplasmic, and transmembrane proteins. The results obtained were significantly better than those of previously developed methods. Even though Gram-positive lipoprotein signal peptides differ from Gram-negatives, the HMM was able to identify 92.9% of the lipoproteins included in a Gram-positive test set. A genome search was carried out for 12 Gram-negative genomes and one Gram-positive genome. The results for Escherichia coli K12 were compared with new experimental data, and the predictions by the HMM agree well with the experimentally verified lipoproteins. A neural network-based predictor was developed for comparison, and it gave very similar results. LipoP is available as a Web server at www.cbs.dtu.dk/services/LipoP/.  相似文献   

11.
12.
With water as the elution solvent, zwitterionic solutes and polyols were retained on HPLC columns, more than was water, by totally hydrophobic packing materials. Relative retentions were systematically affected by oxygen functional groups in the packing material, explicable as specific retention of water. Reproducible elution sequences of 20 solutes at a variety of hydrophobic surfaces (aromatic and both long- and short-alkyl aliphatic surfaces) showed there is a general process, consistent with interactions with hydration water at the surface having solvent properties distinct from bulk water. Early eluting solutes included glycine, sarcosine and taurine. Glycine betaine followed both these and N,N-dimethylglycine. The natural betaines propionobetaine and dimethylsulfoniopropionate also preceded glycine betaine. Dimethylsulfoxide was strongly retained, as (to a lesser extent) was proline betaine. Polyols eluted in the sequence sorbitol, trehalose, glycerol. Changes in the chemical nature of the surface or base material affected relative retentions of water and solutes. The presence of hydrogen-bonding functions increased retention of polyols, as well as water, relative to zwitterionic solutes. Specific effects with some solutes may be related to inconsistencies seen in biological systems. Pressures up to 8 MPa did not affect relative retention, constraining models based on the formation of low-density water.  相似文献   

13.
Detailed procedures are described for successfully digesting reasonably small quantities (i.e., usually >10 pmol) of proteins with a variety of proteases and for then isolating the resulting peptides by reversephase HPLC. Since sodium dodecyl sulfate-polyacrylamide, gel electrophoresis (SDS-PAGE) appears to be the current method of choice for final purification of proteins for structural analysis, special attention is given to carrying out in-gel proteolytic digests on SDS-PAGE-separated proteins that have usually been stained with Coomassie Blue. A compilation of data from nearly 200 “unknown” samples is used to help provide realistic expectations with respect to the results that are likely to be obtained from carrying out in-gel proteolytic digests on large numbers of proteins.  相似文献   

14.
F Ehrenstr?m 《Life sciences》1988,43(7):615-627
A method with improved sensitivity for detection of catechols (CA) in small volumes of plasma using an ion-pair reversed phase HPLC system with electromechemical detection is presented. Fast isocratic separations were obtained by using 7.5 cm x 4.6 mm (i.d.) reversed phase columns with 3C18 3 micron silica particles. The CA:s L-DOPA, Noradrenaline (NA), Adrenaline (A), Dihydroxybenzylamine (DHBA, i.s.), DOPAC and Dopamine (DA) were separated in less than 4 min. The performance of three different electrochemical cells was compared with respect to hydrodynamic voltammogram, band broadening effect, linearity and detection limit. The sample preparation procedure using alumina extraction of CA:s, was modified to improve recoveries and decrease dilution factors. A modified carbon paste cell (CP-O) gave a response 4-8 times higher than what is previously reported for GC cells. Detection limits were: L-DOPA 80, NA 1.25, A 1.25, DHBA 0.4, DOPAC 1.25 and DA 0.6 pg/injection. Application to plasma from rat and fish (cod) under rest, exercise and stress is reported. The method allows determination of CA:s in small volumes of plasma (less than 500 microliter) obtained several times a day from the same animal even if it is small (less than 1/2 kg), is under rest and parts of the plasma sample are to be used for analysis of other parameters than CA:s.  相似文献   

15.
Tjalsma H  van Dijl JM 《Proteomics》2005,5(17):4472-4482
The availability of complete bacterial genome sequences allows proteome-wide predictions of exported proteins that are potentially retained in the cytoplasmic membranes of the corresponding organisms. In practice, however, major problems are encountered with the computer-assisted distinction between (Sec-type) signal peptides that direct exported proteins into the growth medium and lipoprotein signal peptides or amino-terminal membrane anchors that cause protein retention in the membrane. In the present studies, which were aimed at improving methods to predict protein retention in the bacterial cytoplasmic membrane, we have compared sets of membrane-attached and extracellular proteins of Bacillus subtilis that were recently identified through proteomics approaches. The results showed that three classes of membrane-attached proteins can be distinguished. Two classes include 43 lipoproteins and 48 proteins with an amino-terminal transmembrane segment, respectively. Remarkably, a third class includes 31 proteins that remain membrane-retained despite the presence of typical Sec-type signal peptides with consensus signal peptidase recognition sites. This unprecedented finding indicates that unknown mechanisms are involved in membrane retention of this class of proteins. A further novelty is a consensus sequence indicative for release of certain lipoproteins from the membrane by proteolytic shaving. Finally, using non-overlapping sets of secreted and membrane-retained proteins, the accuracy of different signal peptide prediction algorithms was assessed. Accuracy for the prediction of protein retention in the membrane was increased to 82% using a majority-vote approach. Our findings provide important leads for future identification of surface proteins from pathogenic bacteria, which are attractive candidate infection markers and potential targets for drugs or vaccines.  相似文献   

16.
Parameters of statistical models of fully or partially protected peptides' retention on Zorbax ODS and Silasorb C18 have been compared. The proposed model can be used for non-protected linear and cyclic peptides. Special increments have to be introduced in calculation of hydrophobicity of these peptides.  相似文献   

17.
Downstream processing in the manufacturing biopharmaceutical industry is a multistep process separating the desired product from process- and product-related impurities. However, removing product-related impurities, such as product variants, without compromising the product yield or prolonging the process time due to extensive quality control analytics, remains a major challenge. Here, we show how mechanistic model-based monitoring, based on analytical quality control data, can predict product variants by modeling their chromatographic separation during product polishing with reversed phase chromatography. The system was described by a kinetic dispersive model with a modified Langmuir isotherm. Solely quality control analytical data on product and product variant concentrations were used to calibrate the model. This model-based monitoring approach was developed for an insulin purification process. Industrial materials were used in the separation of insulin and two insulin variants, one eluting at the product peak front and one eluting at the product peak tail. The model, fitted to analytical data, used one component to simulate each protein, or two components when a peak displayed a shoulder. This monitoring approach allowed the prediction of the elution patterns of insulin and both insulin variants. The results indicate the potential of using model-based monitoring in downstream polishing at industrial scale to take pooling decisions.  相似文献   

18.
Methodology is described here for the efficient parallel synthesis and cyclization of linear peptide libraries using intramolecular S-alkylation chemistry in combination with Multipin solid phase peptide synthesis (Multipin SPPS). The effective use of this methodology was demonstrated with the synthesis of a 72-member combinatorial library of cyclic thioether peptide derivatives of the conserved four-residue structural motif DD/EXK found in the active sites of the five crystallographically defined orthodox type II restriction endonucleases, EcoRV, EcoRI, PvuII, BamHI and BglI.  相似文献   

19.
A simple method for the sequence prediction of peptides capable of thein vivo stimulation of antibody production in mice without conjugation with protein carriers was proposed on the basis of literature data on the structure of T-helper epitopes active in vivo. According to this approach, a potentially active peptide should contain a nine-membered sequence with a hydrophobic amino acid residue in the first position and a positively charged residue in the ninth position. The efficiency of this approach was confirmed by the presence of such sequences in the previously described synthetic peptides with immune activities, by the application of this approach to the choice of immunogenic fragments within the sequences of various proteins that exhibited further the specific activity, and by the construction of immunogenic peptides on the basis of inactive natural sequences.  相似文献   

20.
The quantitative structure--retention relationship is one of the most actively studied topics in the field of chromatography. In this paper, retention parameters of components were used to discriminate the xanthones in a methanol extract of Swertia franchetiana The extract was analysed by HPLC under two different multistage linear gradient conditions and the retention parameters calculated from these retention data. It was found that the retention parameters of xanthones are in a specific region in the plot of log k(w) vs. S and the xanthones in the extract could be distinguished from other components by this feature. Furthermore, xanthone aglycones and xanthone glucosides could also be discriminated by retention parameters.  相似文献   