首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The Phenomenex EZ:faast™ amino acid analysis kit is available for gas (GC) or liquid (LC) chromatographic analysis of amino acids (AA) using mass spectrometry (MS) and other GC detectors. We used it for rapid GC determination of plasma tryptophan, its brain uptake competitors (Val, Leu, Ile, Phe and Tyr) and many other amino acids. Based on solid-phase extraction, this fast method enables one person to process two plasma samples in 8–10 min and six samples in ∼15 min up to GC injection and a 7-min GC run per plasma sample. Using a Perkin-Elmer Clarus 500 GC, a Total Chrome software, a flame-ionisation detector (FID) and norvaline as internal standard, we used this method to analyse ∼1,000 plasma samples from normal subjects undergoing acute tryptophan depletion and loading tests. The limit of detection for most amino acids is 1 nmol/ml (1 μM) and in many cases less. With manual injection, coefficients of variation for the above six amino acids were 1.5–6.2% (intra-assay) and 3.8–9.7% (inter-assay). This simple, rapid and elegant method will be valuable to the amino acid analyst and researcher, as it can save much manpower time and meet urgent emergency requests and the demands of a high-throughput laboratory.  相似文献   

2.
This paper describes a new approach for quantifying marennine, a blue-green pigment synthesized by the marine diatom Haslea ostrearia, which is known to be responsible for the greening of cultured oysters in French coastal areas. The method uses gel-filtration HPLC interfaced with a photodiode-array detector (PDA). Under the chromatographic conditions applied, the peak of marennine is identified on the dextran pattern at 674 nm by its elution time (ET = 21–22 min) and its UV-Visible absorption spectrum. After calibration with pure marennine sample as external standard, consisting in plotting peak area as a function of marennine concentration, one can back-calculate concentrations of unknown samples. Results for quantitative determination of marennine using this procedure are validated and discussed in relation to those obtained by the spectrophotometric methods, the most often employed until now.  相似文献   

3.
He X  Yuan R  Chai Y  Zhang Y  Shi Y 《Biotechnology letters》2007,29(1):149-155
A novel and sensitive immunosensor has been developed by electro-depositing gold nanoparticles on to a Prussian Blue-modified glassy carbon electrode for determination of hepatitis B surface antigen (HBsAg). After the developed immunosensor was incubated with different concentrations of HBsAg samples at 37°C for 15 min, the current response decreased with an increasing HBsAg concentration in the sample solution. The decreased percentage of the current was proportional to HBsAg concentration ranging from 2 to 300 ng HbsAg ml−1 with a detection limit of 0.42 ng HbsAg ml−1 (S/N = 3). Analytical results of 50 specimens using the developed immunosensor showed satisfactory agreement with those using ELISA, indicating the method to be a promising alternative for detecting HBsAg in clinical diagnosis.  相似文献   

4.
Photodynamic inactivation is a new promising approach to treat bacterial infections. Usually, the evaluation of the efficacy of this method is done through time-consuming and labor-intensive microbiological test methods. This paper describes the development and implementation of an optical method to evaluate the photodynamic inactivation of bacteria based on non-invasive diffuse reflectance measurements. Five Staphylococcus aureus cultures and 15 mice have been used in this study. A skin lesion was created on the back of all animals, and it was contaminated with S. aureus (5.16 ± 0.013 log CFU/ml). Toluidine Blue O (c = 8.67 × 10 − 3 M) has been used as a photosensitiser agent. The bacterial cultures and animals were exposed to laser radiation (λ = 635 nm, P = 15 mW, DE = 8.654 J/cm2) for 20 min. The photodynamic inactivation of bacteria was monitored by acquiring the wounds’ reflection spectra at different time points and by microbiological exams on the bioptical material. The good correlation between the diffuse reflectance and colony-forming units demonstrates the value of this optical method based on diffuse reflectance measurements as a rapid technique to monitor photodynamic bacterial inactivation.  相似文献   

5.
A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a “second-generation” biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent.  相似文献   

6.
A bioanalytical method for the determination of the anticancer drug chlorambucil (Leukeran™) and its phenyl acetic acid mustard metabolite in human serum and plasma is described. Automated solid-phase extraction of the analytes is carried out with C18 sorbent packed in a 96 well format microtitre plate using a robotic sample processor. The extracts are analysed by isocratic reversed-phase liquid chromatography using pneumatically and thermally assisted electrospray ionisation (TurboIonspray) with selected reaction monitoring. The method is specific and sensitive, with a range of 4–800 ng/ml in human serum and plasma for both parent drug and metabolite (sample volume 200 μl). The method is accurate and precise with intra-assay and inter-assay precision (C.V.) of <15% and bias <15% for both analytes. The automated extraction procedure is significantly faster than manual sample pre-treatment methods, a batch of 96 samples is extracted in 50 min allowing for faster sample turnaround. The method has been used to provide pharmacokinetic support to biocomparability studies of Leukeran™ following single doses of oral tablet formulations.  相似文献   

7.
The effects of temperatures, durations of treatment, and derivations from spermatophores or spermaries on in vitro acrosome reaction of the spermatozoa in the Chinese mitten crab Eriocheir sinensis were investigated. The results showed that the different temperatures resulted in extremely significant differences (p < 0.01) in the time of beginning acrosome reaction, the time of the maximum percentage of acrosome reaction, and the maximum percentage of acrosome reaction of the spermatozoa from spermatophores; and the low temperature (−20, −80 °C and liquid nitrogen) induced acrosome reaction of more than 90% spermatozoa while 15 and 4 °C didn’t. Similar results occur in the spermatozoa, treated with −80 °C for 15 min, from spermaries but the time of beginning acrosome reaction and the time of the maximum percentage of acrosome reaction were obviously longer than those from spermatophores. In conclusion, low temperature can induce acrosome reaction, which is a novel and efficient operating method of inducing acrosome reaction; the spermatozoa might be affected physiologically to capacitate with chilling. The study may be beneficial to new understandings of mechanism of acrosome reaction and provide the foundational material for artificial fertilization and breeding of this crab and other commercial aquatic crustaceans.  相似文献   

8.
To conduct studies of stable isotope incorporation and dilution in growing plants, a rapid microscale method for determination of amino acid profiles from minute amounts of plant samples was developed. The method involves solid-phase ion exchange followed by derivatization and analysis by gas chromatography–mass spectrometry (GC–MS). The procedure allowed the eluent to be derivatized directly with methyl chloroformate without sample lyophilization or other evaporation procedures. Sample extraction and derivatization required only ca. 30 min and quantification of the 19 amino acids eluted from the cation exchange solid-phase extraction step from a single cotyledon (0.4 mg fresh weight) or three etiolated 7-day-old Arabidopsis seedlings (0.1 mg fresh weight) was easily accomplished in the selected ion monitoring mode. This method was especially useful for monitoring mass isotopic distribution of amino acids as illustrated by Arabidopsis seedlings that had been labeled with deuterium oxide and 15N salts. Sample preparation was facile, rapid, economical, and the method is easily modified for integration into robotic systems for analysis with large numbers of samples.  相似文献   

9.
A method for simultaneous bioanalysis of the three cytotoxic drugs cytosine arabinoside, daunorubicin and etoposide in human plasma was developed and validated. A HPLC method with ultra-violet and fluorescence detection, preceded by mixed-mode cation-exchange solid phase extraction sample preparation, was used for the quantification of the analytes. The assay was used for the simultaneous measurement of cytosine arabinoside, daunorubicin and etoposide with linearity in the ranges of 13–1500 ng/mL, 15–1000 ng/mL and 52.5–3500 ng/mL, respectively. The chromatographic run-time was 15.5 min. The overall precision (% relative standard deviation) was within 0.2–13.5% and the recovery ranged between 86.1% and 110.1% for the three drugs at all concentrations tested. Plasma samples were stable for at least two months when stored at −20 °C. The method was successfully applied to quantification of the three drugs in blood samples from patients undergoing induction treatment for acute myeloid leukaemia, thus demonstrating its suitability for clinical studies.  相似文献   

10.
Light-induced fluorescence (LIF) was evaluated as a process analytical technology to monitor blend homogeneity and establish a relationship with high-performance liquid chromatography (HPLC). Secondary aims for this study included a determination of blend steady-state, acceptable mixing time interval, and mixing end point. Also, identification of potential “dead spots” in the 124 L intermediate bulk container mixing tote was explored. Individual samples from 13 sample locations were collected at 0.25, 0.5, 0.75, 1, 2, 5, 10, and 20 min and analyzed using LIF and HPLC. LIF and HPLC methods showed similar mixing profiles. A coefficient of determination (R 2) of 0.86 (p value < 0.0001) was obtained for a second-degree polynomial bivariate fit of LIF counts by HPLC percent label claim (%LC). A significant linear relationship was determined between LIF percent relative standard (%RSD) and HPLC %RSD (R 2 = 0.97, p < 0.0001). The LIF steady-state, acceptable mixing time interval, and mixing end point were determined to be 1–20, 2–20, and 2 min, respectively. The steady-state, acceptable mixing time interval, and mixing end point determined by HPLC were 1–20, 5–10, and 5 min, respectively. The Tukey–Kramer honestly significant difference analysis of HPLC %LC by sample location at 5 and 10 min mixing times showed that there was a statistical difference between the HPLC %LC group means at two blender locations.  相似文献   

11.
A new direct colorimetric assay of microcystin in water and algal samples is proposed consisting of two procedures as follows: 1) the elimination of phosphorus in the sample and concentration of microcystin using a C18 cartridge, 2) the detection of the released phosphorus by the ascorbic acid method and determination of protein phosphatase (PP) inhibition by microcystin. The optimum amounts of phosphorylase α and PP-1 in 50 μL concentrated sample were 50 μg/50 μL buffer and 1.0 unit/50 μL buffer, respectively, for the best assay. The pH for the maximum activity of PP-1 was 8. The minimum detectable concentration for this method was about 0.02 μg/L, which is sufficient to meet the proposed guideline level of 1 μg microcystin/L in drinking water. Consequently, it would seem that the proposed direct colorimetric assay using PP is a rapid, easy, and convenient method for the detection of microcystin in water and algal samples.  相似文献   

12.
This paper describes a simple and sensitive reversed-phase HPLC method for the determination of total homocysteine, total cysteine, total glutathione (GSH + GSSG), and neuroactive amino acids (Asp, Glu, Tau, GABA) using precolumn derivatization with ortho-phtaldialdehyde and fluorimetric detection at 360 and 470 nm for emission and excitation, respectively. Derivatization was performed with ortho-phthaldialdehyde in the presence of 2-mercaptoethanol after alkylation of free sulfhydryl groups with iodoacetic acid. For determination of total aminothiols, the disulfide bonds were reduced and protein-bound thiols were released by addition of dithiothreitol to the plasma sample. The advantage of this method is the simultaneous determination of both homocysteine/cysteine/glutathione and neuroactive amino acids in the sample. The plasma levels of studied compounds were determined in 14 healthy volunteers (20–45 years old) and 55 patients with chronic hepatitis C (20–49 years old) and the resulting values were in a good agreement with results published earlier. The calibration curves were linear over a concentration range of 5–100 μM in plasma (r 2 = 0.985−0.996). The intraday and interday coefficients of variation were 3–6% and 4–7%, respectively. The recovery of the standards added to the plasma samples ranged from 94 to 102%. The limits of detection (LOD) were 0.2–0.5 ng per 10 μl of the injection volume (signal-to-noise ratio of 3).  相似文献   

13.
A simple purge-and-trap gas chromatographic method with flame ionization detection was developed for the determination of styrene in urine and blood. Styrene present in a 5 ml sample at room temperature was swept by helium at 40 ml/min for 11 min, trapped on a Tenax trap, desorbed by heating, cryofocused, and injected by flash heating into a DB-5 capillary GC column. The oven temperature program was from 80°C, held for 8 min, to 120°C at 5°C/min, and then held for 2 min. The detector temperature was 250°C. The calibration curves were linear in the range of 2.5–15 ppb styrene in urine and 25–150 ppb in blood. The detection limits calculated were 0.4 μg/l in urine and 0.6 μg/l in blood. The coefficients of variations within the day and day-to-day were 3 and 3.1%, respectively, for 2.5 ppb of styrene in urine, and 1 and 1.6% for 25 ppb of styrene in blood. The results obtained from samples taken from workers exposed to styrene were reported.  相似文献   

14.
A new, simple, and fast method for preconcentration and determination of trace amount of lead from biological samples was developed by modified silver nanoparticle-based solid-phase extraction technique and graphite furnace atomic absorption spectrometry. In this study, morin was used as a complexing agent. Some factors influencing the recovery of lead including pH, sample flow rate, type, flow rate, and least amount of the eluent for elution of the lead from silver nanoparticles were studied and optimized. Under the optimum conditions, the detection limit of this method was 68 ng L−1, and the relative standard deviation was 4.1% (n = 10, c = 20 μg L−1). The developed procedure was validated by the analysis of certified reference material and applied to the recovery and determination of lead in biological samples.  相似文献   

15.
In this study, a solid-phase extraction method combined with atomic absorption spectrometry for extraction, preconcentration, and determination of iron (Fe3+), copper (Cu2+), and lead (Pb2+) ions at trace levels in water samples has been reported. The influences of effective parameters such as flow rate, pH, eluent conditions (type, volume, and concentration), sample volumes, and interference of matrix ions on metal ions recoveries were studied. Under optimized conditions, the limits of detection were found in the range of 0.7–2.2 μg L−1, while preconcentration factors for Fe3+, Cu2+, and Pb2+ ions were found to be 166, 200, and 250, respectively, and loading half time (t 1/2) values were less than 2 min for all analyte ions. The proposed procedure was applied for the determination of metal ions in different water samples with recovery of >94.4% and relative standard deviation less than 4.4% for N = 5.  相似文献   

16.
Aeromonas hydrophila and other aeromonads are ubiquitous organisms found in meat, vegetables, drinking water and various other food items. They cause diarrhea and extra-intestinal infections in normal and immunocompromised patients. The aim of the study was to develop a multiplex PCR assay for the detection of virulence-associated genes of Aeromonas including hemolysin (hlyA), aerolysin (aerA), glycerophospholipid-cholesterol acyl transferase (GCAT) alongwith a 16S rRNA gene. Internal amplification control (IAC), which was coamplified with aerA primers, was also included in this study. The results showed that all cultures of Aeromonas were accurately identified by the assay without showing non-specificity. A. hydrophila could be detected at a range of 10–50 CFU ml−1 from experimentally spiked fish, chicken and milk samples following overnight enrichment in alkaline peptone water supplemented with 10 μg/ml ampicillin (APW-A) by this multiplex PCR (mPCR). When evaluated on a total of 74 naturally occurring food samples, four samples were identified to contain Aeromonas by mPCR. All these results were compared to the conventional culture, isolation and biochemical identification procedures. The high throughput and cost-effective mPCR method developed in this study could provide a powerful tool for detection of pathogenic Aeromonas spp. from food and environmental samples and in addition, the method has advantages in terms of specificity, sensitivity and ease of use compared to other reported PCR methods and DNA hybridization assays.  相似文献   

17.
A flow injection-inductively coupled plasma-mass spectrometry (FI-ICP-MS) with a simple sample preparation procedure was developed for the determination of selenium, copper, and zinc in blood serum/plasma. A serum/plasma sample was filtered through a 0.45-μm membrane filter and diluted with a mixture of trace elements in a standard solution (9∶1, v/v). Measurement of the reference serum sample confirmed the accuracy of our method for selenium, copper, and zinc concentration. In the case of blood plasma samples obtained from six healthy adult males, the selenium, copper, and zinc concentrations were similar to those of a typical healthy male in Japan. These results suggest that the sample prepartive procedure coupled with FI-ICP-MS can be used for the routine determination of selenium, copper, and zinc in human blood serum/plasma.  相似文献   

18.
A column-switching method was developed for the determination of total 3-methoxy-4-hydroxy-phenylethyleneglycol (MHPG) in urine. This was performed by first treating samples with β-glucuronidase, followed by extraction with ethyl acetate. The reconstituted extracts with injected onto an HPLC system containing an amperometric detector and tandem Nucleosil C18 and C8 reversed-phase columns connected by a switching valve. The total analysis time for MHPG was 12 min. The limit of detection was 0.18 ng, or 9 μg/l for 20-μl injections of a 1.0-ml reconstituted extract prepared from 1.0 ml of urine. The linear range extended up to 80 mg/l. The within-day precision for a urine sample containing 170 μg/l total MHPG was ±6% and the day-to-day precision was ±15%. The average levels determined by this method for total MHPG in normal subjects showed good agreement with previous literature values. This approach could be modified for the determination of free MHPG by using only ethyl acetate extraction for sample pretreatment.  相似文献   

19.
A high-performance liquid chromatographic method using column switching was applied to the direct determination of two local anaesthetics, ropivacaine and bupivacaine, in human plasma. The method is intended to be used in a combined LC—GC system; here only the LC-part is described. After addition of internal standard, the samples were filtered and directly injected into a semipermeable surface (SPS) pre-column where the analytes were strongly retained and separated from many endogenous compounds by a short washing step. The retained analytes were transferred by a buffered methanol phase from the pre-column into a carbonaceous HPLC column and they were detected by UV detection at 254 nm. The SPS pre-column could withstand numerous (> 200) direct injections of plasma samples (10 μl). The method has a detection limit of 8.2 ng and requires a total assay time of 15 min per plasma sample. Quantitative recoveries were obtained over the range 3.3–114 μg/ml with inter-day precisions of 1.6–5.2% (C.V.).  相似文献   

20.
The effectiveness of capillary electrophoresis (CE) in the field of stereoselective determination of drugs in biological matrices is demonstrated by analyzing clenbuterol in human urine. Due to the very low therapeutical doses of 20–40 μg per day the total concentrations in urine are 1–10 ng/ml. The sample was extracted with hexane–tert.-butyl methyl ether (99.5:0.5). The reconstituted sample was injected electrokinetically (50 s, 10 kV). Using phosphate buffer, pH 3.3 and hydroxyethyl-β-cyclodextrin as chiral selector the total analysis time was below 15 min. The limit of determination was estimated as 0.5 ng/ml per enantiomer. S-(−)-Bupranolol was used as internal standard. Both precision and accuracy of the method were within the limits for biological samples. The application to human urine from patients having received therapeutical doses showed a slightly predominant excretion of the (+)-enantiomer to the (−)-enantiomer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号