Leucine-rich alpha-2-glycoprotein (LRG1) was found to be differentially expressed in sera from patients with Epithelial Ovarian Cancer (EOC). The aim of this study is to investigate the performance of LRG1 for detection of EOC, including early stage EOC, and to evaluate if LRG1 can complement CA125 in order to improve EOC detection using two independent blinded sample sets.

Methods and Results

Serum LRG1 and CA125 were measured by immunoassays. All assays were performed blinded to clinical data. Using the two independent sample sets (156 participants for sample set 1, and 233 for sample set 2), LRG1 was differentially expressed in EOC cases as compared to healthy, surgical, and benign controls, and its performance was not affected by the conditions of blood collection. The areas under the ROC curve (AUC) for LRG1 in differentiating EOC cases from non-cases were 0.797 and 0.786 for sample set 1 and 2. For differentiating EOC cases from healthy controls, the AUC values for LRG1 were 0.792 and 0.794. At a fixed specificity of 95%, LRG1 detects 52%, and 53.5% of EOC cases from healthy controls for sample set 1 and 2. When combining LRG1 and CA125, the AUC value increased to 0.927, which was improved compared to CA125 (AUC=0.916) (p=0.008) alone in distinguishing EOC cases from non-cases. More importantly, LRG1 also showed potential performance in differentiating early stage EOC from non-cases with an AUC of 0.715 for sample set 1, and 0.690 for sample set 2. The combination of LRG1 and CA125 resulted in an AUC of 0.838, which outperforms CA125 (AUC=0.785) (p=0.018) in detecting early stage EOC cases from non-cases using the larger sample set.

Conclusions

LRG1 could be a useful biomarker alone or in combination with CA125 for the diagnosis of ovarian cancer.  相似文献   

2.
BackgroundBreast cancer (BC) is the most common cancer for women all over the world. Great interests have been paid to discover accurate and noninvasive methods for breast cancer diagnosis and prognosis. Although the diagnostic and prognostic value of microRNA-200 (miRNA- 200, miR-200) family has been revealed in many studies, the results were inconsistent. Thus, this meta-analysis aims to assess the overall value of miRNA-200 family in breast cancer diagnosis and prognosis.MethodRelevant studies were searched from the following databases: PubMed, PMC, EMBASE, and ScienceDirect using key words: ("miRNA-200 family" or "miR-141" or "miR-200a" or "miR-200b" or "miR-200c" or "miR-429") and (“HER2” or “Luminal A” or “Luminal B” or “TNBC”) and ("breast cancers" or "breast carcinoma" or "breast malignancy" or "breast tumor"). The sensitivity, specificity, AUC were then calculated to estimate the diagnostic accuracy of the miR-200 family. As for the prognostic value of the miR-200 family, the pooled hazard ratio (HR) was assessed. Heterogeneity among individual studies was also examined by subgroup analyses.ResultA total of 24 articles were included in the meta-analysis. The diagnostic value of miR-200s in BC was presented by the pooled sensitivity was 0.86 (95% CI: 0.83-0.88); the pooled specificity was 0.82 (95% CI: 0.72-0.89); the pooled AUC was 0.931 (95% CI: 0.919-0.942). Besides, expression of miR-200s in metastatic breast cancer has sensitivity, specificity and AUC of 0.70 (95%CI: 0.56-0.81), 0.72 (95%CI: 0.61-0.81), and 0.814 (95%CI: 0.741-0.903), respectively. The meta-analysis then revealed that high expression of miR-200 family corresponded to poor OS (HR: 1.63, 95% CI: 1.03-2.52), poor DFS (HR: 1.55, 95% CI: 0.95-2.56) in BC patients while downregulation of miRNA-200s corresponded to poor OS (HR= 0.84, 95%CI: 0.46-1.63) in TNBC patients and poor OS (HR=0.49; 95%CI: 0.27-0.88) in luminal BC patient.ConclusionThe MiR-200 family has high diagnostic accuracy and can be used as an important biomarker to prognosticate breast cancer.  相似文献   

3.

Background

HIV increases women’s risk for high-risk human papillomavirus (hrHPV) infection and invasive cervical cancer. South Africa has a high HIV prevalence but low cervical cancer screening coverage. Self-collection of cervical specimens and hrHPV testing, including hrHPV messenger-RNA (mRNA) testing, are methods aimed at increasing screening rates. However, data are limited on the acceptability and accuracy of tampon-based self-collection for hrHPV mRNA testing in HIV-infected women.

Methods

We recruited 325 HIV-infected women seeking care at a government HIV clinic in Pretoria, South Africa. A clinician performed a pelvic examination and obtained an endocervical specimen. Study participants performed self-collection using a tampon. Both clinician- and self-collected specimens were tested for hrHPV mRNA. Acceptability of both collection methods was assessed, the prevalence of hrHPV mRNA in our study population was estimated, test positivity of the two collection methods were compared, and test agreement was assessed by calculating the κ-statistic, sensitivity, and specificity.

Results

Over 90% of women reported no difficulties self-collecting specimens and 82% were willing to perform the tampon-collection at home. Based on clinician-collection specimens, the prevalence of hrHPV mRNA in our study population was 36.7% (95% CI: 31.4%– 42.0%). There was no difference in test positivity between clinician-collection, 36.7%, and tampon-collection, 43.5% (p-value = 0.08). Using clinician-collection as the reference test, the sensitivity and specificity for hrHPV mRNA of tampon-collection were 77.4% (95% CI: 69.8–85.0%) and 77.8% (95% CI: 71.9–83.6%), respectively.

Conclusions

Tampon-based self-collection is acceptable to women and has similar hrHPV mRNA positivity rates as clinician-collection, but has reduced sensitivity and specificity compared to clinician-collection. The hrHPV mRNA prevalence in our study population is high, but similar to other high-risk populations, and highlights the need for improved cervical cancer screening. Further research into the optimal use of tampon-based collection as a cervical cancer screening tool is warranted.  相似文献   

4.

Background

Human pepsinogens are considered promising serological biomarkers for the screening of atrophic gastritis (AG) and gastric cancer (GC). However, there has been controversy in the literature with respect to the validity of serum pepsinogen (SPG) for the detection of GC and AG. Consequently, we conducted a systematic review and meta-analysis to assess the diagnostic accuracy of SPG in GC and AG detection.

Methods

We searched PubMed, Embase, and the Chinese National Knowledge Infrastructure (CNKI) for correlative original studies published up to September 30, 2014. The summary sensitivity, specificity, positive diagnostic likelihood ratio (DLR+), negative diagnostic likelihood ratio (DLR-), area under the summary receiver operating characteristic curve (AUC) and diagnostic odds ratio (DOR) were used to evaluate SPG in GC and AG screening based on bivariate random effects models. The inter-study heterogeneity was evaluated by the I2 statistics and publication bias was assessed using Begg and Mazumdar’s test. Meta-regression and subgroup analyses were performed to explore study heterogeneity.

Results

In total, 31 studies involving 1,520 GC patients and 2,265 AG patients were included in the meta-analysis. The summary sensitivity, specificity, DLR+, DLR-, AUC and DOR for GC screening using SPG were 0.69 (95% CI: 0.60–0.76), 0.73 (95% CI: 0.62–0.82), 2.57 (95% CI: 1.82–3.62), and 0.43 (95% CI: 0.34–0.54), 0.76 (95% CI: 0.72–0.80) and 6.01 (95% CI: 3.69–9.79), respectively. For AG screening, the summary sensitivity, specificity, DLR+, DLR-, AUC and DOR were 0.69 (95% CI: 0.55–0.80), 0.88 (95% CI: 0.77–0.94), 5.80 (95% CI: 3.06–10.99), and 0.35 (95% CI: 0.24–0.51), 0.85 (95% CI: 0.82–0.88) and 16.50 (95% CI: 8.18–33.28), respectively. In subgroup analysis, the use of combination of concentration of PGI and the ratio of PGI:PGII as measurement of SPG for GC screening yielded sensitivity of 0.70 (95% CI: 0.66–0.75), specificity of 0.79 (95% CI: 0.79–0.80), DOR of 6.92 (95% CI: 4.36–11.00), and AUC of 0.78 (95% CI: 0.72–0.81), while the use of concentration of PGI yielded sensitivity of 0.55 (95% CI: 0.51–0.60), specificity of 0.79 (95% CI: 0.76–0.82), DOR of 6.88 (95% CI: 2.30–20.60), and AUC of 0.77 (95% CI: 0.73–0.92). For AG screening, the use of ratio of PGI:PGII as measurement of SPG yielded sensitivity of 0.69 (95% CI: 0.52–0.83), specificity of 0.84 (95% CI: 0.68–0.93), DOR of 11.51 (95% CI: 6.14–21.56), and AUC of 0.83 (95% CI: 0.80–0.86), the use of combination of concentration of PGI and the ratio of PGI:PGII yield sensitivity of 0.79 (95% CI: 0.72–0.85), specificity of 0.89 (95% CI: 0.85–0.93), DOR of 24.64 (95% CI: 6.95–87.37), and AUC of 0.87 (95% CI: 0.81–0.92), concurrently, the use of concentration of PGI yield sensitivity of 0.46 (95% CI: 0.38–0.54), specificity of 0.93 (95% CI: 0.91–0.95), DOR of 19.86 (95% CI: 0.86–456.91), and AUC of 0.86 (95% CI: 0.52–1.00).

Conclusion

SPG has great potential as a noninvasive, population-based screening tool in GC and AG screening. In addition, given the potential publication bias and high heterogeneity of the included studies, further high quality studies are required in the future.  相似文献   

5.

Background

Women with low grade squamous intraepithelial lesions (LSIL) at cervical cancer screening are currently referred for further diagnostic work up despite 80% having no precancerous lesion. The primary purpose of this study is to measure the test characteristics of 3q26 chromosome gain (3q26 gain) as a host marker of carcinogenesis in women with LSIL. A negative triage test may allow these women to be followed by cytology alone without immediate referral to colposcopy.

Methods and Findings

A historical prospective study was designed to measure 3q26 gain from the archived liquid cytology specimens diagnosed as LSIL among women attending colposcopy between 2007 and 2009. 3q26 gain was assessed on the index liquid sample; and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were measured at immediate triage and at 6–16 months after colposcopic biopsy. The sensitivity of 3q26 gain measured at immediate triage from automated and manually reviewed tests in 65 non-pregnant unique women was 70% (95% CI: 35, 93) with a NPV of 89% (95% CI: 78, 96). The sensitivity and NPV increased to 80% (95% CI: 28, 99) and 98% (95% CI: 87, 100), respectively, when only the automated method of detecting 3q26 gain was used.

Conclusions

3q26 gain demonstrates high sensitivity and NPV as a negative triage test for women with LSIL, allowing possible guideline changes to routine surveillance instead of immediate colposcopy. Prospective studies are ongoing to establish the sensitivity, specificity, PPV and NPV of 3q26 gain for LSIL over time.  相似文献   

6.
This study was conducted to determine whether the ratio of estrogen-DNA adducts to their respective metabolites and conjugates in serum differed between women with early-onset breast cancer and those with average or high risk of developing breast cancer. Serum samples from women at average risk (n=63) or high risk (n=80) for breast cancer (using Gail model) and women newly diagnosed with early breast cancer (n=79) were analyzed using UPLC-MS/MS. Adduct ratios were statistically compared among the three groups, and the Area Under the Receiver Operating Characteristic Curve (AUC) was used to identify a diagnostic cut-off point. The median adduct ratio in the average-risk group was significantly lower than that of both the high-risk group and the breast cancer group (p values<0.0001), and provided good discrimination between those at average versus high risk of breast cancer (AUC=0.84, 95% CI 0.77-0.90). Sensitivity and specificity were maximized at an adduct ratio of 77. For women in the same age and BMI group, the odds of being at high risk for breast cancer was 8.03 (95% CI 3.46-18.7) times higher for those with a ratio of at least 77 compared to those with a ratio less than 77. The likelihood of being at high risk for breast cancer was significantly increased for those with a high adduct ratio relative to those with a low adduct ratio. These findings suggest that estrogen-DNA adducts deserve further study as potential biomarkers for risk of developing breast cancer.  相似文献   

7.
OBJECTIVE: To examine the diagnostic value (sensitivity and specificity of the ThinPrep Pap test in the detection of endometrial cancer and assess the morphologic features of endometrial cancer in ThinPrep tests. STUDY DESIGN: In a retrospective, case-controlled study, we identified 60 Pap slides performed within 12 months of the tissue diagnosis of endometrial carcinoma and 56 comparison slides from patients without known carcinoma. The slides were blindly reviewed by the authors without knowledge of the surgical diagnosis. An independent diagnosis was given for the tests based on 14 diagnostic criteria from the 2001 Bethesda System and 6 additional criteria proposed by the authors. RESULTS: The sensitivity of detecting endometrial carcinoma was 88.3% (95% CI 77.8-94.2%) and specificity was 87.5% (95% CI 76.4-93.8%). The positive likelihood ratio was 7.067 (95% CI 3.513-14.217) and negative likelihood ratio was 0.133 (95% CI 0.066-0.269). Enlarged nuclei and the presence of nucleoli in endometrial cells were the most reliable indicators of endometrial cancer or atypical endometrial cells. CONCLUSION: The ThinPrep Pap test has high sensitivity and specificity in detecting or suggesting the presence of endometrial cancer. Certain cytomorphologic features are helpful in distinguishing benign and malignant endometrial lesions.  相似文献   

8.
9.

Objective

To assess the value of anaplastic lymphoma kinase for the diagnosis of inflammatory myofibroblastic tumours using a comprehensive meta-analysis.

Methods

We searched the related literature using electronic databases and manual searches. Approximately 454 cases from several countries were included in this analysis. The quality of studies included was assessed by QUADAS (quality assessment of studies of diagnostic accuracy). The diagnostic odds ratio (DOR), positive likelihood ratio (PLR), negative likelihood ratio (NLR), sensitivity and specificity were calculated to assess the role of anaplastic lymphoma kinase in the diagnosis of inflammatory myofibroblastic tumours. The overall test performance was summarised by an SROC (summary receiver operating characteristic curve). The heterogeneity and publication bias were analysed using Meta-regression and Deeks'' test. All data were analysed by Stata 12.0 software.

Results

Eight studies were included according to our inclusion criteria. The overall results for the specificity, sensitivity, PLR, NLR, DOR and area under the curve (AUC) were 0.99 (95% CI 0.82-1.00), 0.67 (95% CI 0.46-0.83), 0.67 (95% CI 0.46-0.83), 60.6 (95% CI 3.3-1112.4), 0.33 (95% CI 0.19-0.60), 181 (95% CI 9-3684) and 0.95 (95% CI 0.93-0.97), respectively, while the specificity, sensitivity, PLR, NLR, DOR and AUC for bladder IMTs were 0.99 (95% CI 0.67-1.00), 0.86 (95% CI 0.58-0.96), 95.6 (95% CI 2.0-4616.2), 0.14 (95% CI 0.04-0.50), 671 (95% CI 16-28913) and 0.99 (95% CI 0.97-0.99), respectively.

Conclusion

The present meta-analysis indicated that anaplastic lymphoma kinase plays a significant role in the differential diagnosis of inflammatory myofibroblastic tumours, particularly for inflammatory myofibroblastic tumours of the urinary bladder.  相似文献   

10.
A metabolomics approach for prediction of bacteremic sepsis in patients in the emergency room (ER) was investigated. In a prospective study, whole blood samples from 65 patients with bacteremic sepsis and 49 ER controls were compared. The blood samples were analyzed using gas chromatography coupled to time-of-flight mass spectrometry. Multivariate and logistic regression modeling using metabolites identified by chromatography or using conventional laboratory parameters and clinical scores of infection were employed. A predictive model of bacteremic sepsis with 107 metabolites was developed and validated. The number of metabolites was reduced stepwise until identifying a set of 6 predictive metabolites. A 6-metabolite predictive logistic regression model showed a sensitivity of 0.91(95% CI 0.69–0.99) and a specificity 0.84 (95% CI 0.58–0.94) with an AUC of 0.93 (95% CI 0.89–1.01). Myristic acid was the single most predictive metabolite, with a sensitivity of 1.00 (95% CI 0.85–1.00) and specificity of 0.95 (95% CI 0.74–0.99), and performed better than various combinations of conventional laboratory and clinical parameters. We found that a metabolomics approach for analysis of acute blood samples was useful for identification of patients with bacteremic sepsis. Metabolomics should be further evaluated as a new tool for infection diagnostics.  相似文献   

11.
BACKGROUND: A number of noninvasive tests have been developed to establish the presence of Helicobacter pylori infection. Although polyclonal antibody-based stool antigen testing has a good sensitivity and specificity, it is less accurate than urea breath testing. Recently, a monoclonal antibody-based stool antigen test demonstrated an excellent performance in diagnosing H. pylori infection in adults and in pediatric populations. AIM: To evaluate the diagnostic accuracy of a novel stool test based on monoclonal antibodies to detect H. pylori antigens in frozen human stool in the pretreatment setting. PATIENTS AND METHODS: Stool specimens were prospectively collected from 78 patients undergoing gastroscopy and stored at -20 degrees C until tested. Helicobacter pylori infection was evaluated by histology, rapid urease testing and urea breath tests ((13)C-UBT). Positivity of the three tests was considered the gold standard for H. pylori active infection. Patients with no positive test were considered negative. The gold standard was compare to the results of the monoclonal antibody stool antigen test. Frozen stool specimens were tested using a novel monoclonal-antibody-based enzyme immunoassay (HePy-Stool, Biolife-Italiana, Milan, Italy). RESULTS: The sensitivity and specificity of the monoclonal stool antigen test were 97%[95% confidence interval, (CI) 86-100] and 94% (95% CI: 81-99), respectively. Negative and positive predictive values were 97% (95% CI: 85-99), and 95% (95% CI: 83-99), respectively. The diagnostic accuracy was 96% (95% CI: 88-99). The likelihood ratio for a positive test was 17 and for a negative test was 0. CONCLUSIONS: Although the (13)C-UBT is the most accurate among the available noninvasive tests, our results show that an H. pylori stool test using monoclonal antibody might be an excellent alternative.  相似文献   

12.

Objective

To determine the accuracy of MR imaging with gadoxetic acid disodium (Gd-EOB-DTPA) for the detection of hepatocelluar carcinoma (HCC).

Materials and Methods

A systematic search was performed in PUBMED, EMBASE, Web of Science, Cochrane Library and the Chinese Biomedical Literature Database up to March 2013 to identify studies about evaluation of Gd-EOB-DTPA enhanced MR imaging in patients suspected of having HCC. The data were extracted to perform heterogeneity test and threshold effect test and to calculate sensitivity, specificity, diagnostic odds ratio, predictive value, and areas under summary receiver operating characteristic curve (AUC).

Results

From 601 citations, 10 were included in the meta-analysis. The methodological quality of the 10 studies was good. Overall HCC: There was significant heterogeneity in the pooled analysis (I2 = 69.4%, P = 0.0005), and the pooled weighted values were determined to be sensitivity: 0.91 (95% confidence interval (CI): 0.89, 0. 93); specificity: 0.95 (95% CI: 0.94, 0.96); diagnostic odds ratio: 169.94 (95% CI: 108.84, 265.36); positive likelihood ratio: 15.75 (95% CI: 7.45, 33.31); negative likelihood ratio: 0.10 (95% CI: 0.06, 0.15). The AUC was 0.9778. HCC in cirrhosis: The estimates were to be sensitivity: 0.91 (95% CI: 0.88, 0.93); specificity: 0.93 (95% CI: 0.89, 0.95); diagnostic odds ratio: 234.24 (95% CI: 33.47, 1639.25); positive likelihood ratio: 15.08 (95% CI: 2.20, 103.40); negative likelihood ratio: 0.08 (95% CI: 0.03, 0.21). The AUC was 0.9814. ≤20 mm HCC: The AUC was 0.9936. There was no notable publication bias.

Conclusions

This meta-analysis suggests that MR imaging with Gd-EOB-DTPA has high diagnostic accuracy for the detection of HCC, especially for ≤20 mm HCC. This technique shows good prospect in diagnosis of HCC.  相似文献   

13.
BackgroundCervical cancer screening strategies using visual inspection or cytology may have suboptimal diagnostic accuracy for detection of precancer in women living with HIV (WLHIV). The optimal screen and screen–triage strategy, age to initiate, and frequency of screening for WLHIV remain unclear. This study evaluated the sensitivity, specificity, and positive predictive value of different cervical cancer strategies in WLHIV in Africa.Methods and findingsWLHIV aged 25–50 years attending HIV treatment centres in Burkina Faso (BF) and South Africa (SA) from 5 December 2011 to 30 October 2012 were enrolled in a prospective evaluation study of visual inspection using acetic acid (VIA) or visual inspection using Lugol’s iodine (VILI), high-risk human papillomavirus DNA test (Hybrid Capture 2 [HC2] or careHPV), and cytology for histology-verified high-grade cervical intraepithelial neoplasia (CIN2+/CIN3+) at baseline and endline, a median 16 months later. Among 1,238 women (BF: 615; SA: 623), median age was 36 and 34 years (p < 0.001), 28.6% and 49.6% ever had prior cervical cancer screening (p < 0.001), and 69.9% and 64.2% were taking ART at enrolment (p = 0.045) in BF and SA, respectively. CIN2+ prevalence was 5.8% and 22.4% in BF and SA (p < 0.001), respectively. VIA had low sensitivity for CIN2+ (44.7%, 95% confidence interval [CI] 36.9%–52.7%) and CIN3+ (56.1%, 95% CI 43.3%–68.3%) in both countries, with specificity for ≤CIN1 of 78.7% (95% CI 76.0%–81.3%). HC2 had sensitivity of 88.8% (95% CI 82.9%–93.2%) for CIN2+ and 86.4% (95% CI 75.7%–93.6%) for CIN3+. Specificity for ≤CIN1 was 55.4% (95% CI 52.2%–58.6%), and screen positivity was 51.3%. Specificity was higher with a restricted genotype (HPV16/18/31/33/35/45/52/58) approach (73.5%, 95% CI 70.6%–76.2%), with lower screen positivity (33.7%), although there was lower sensitivity for CIN3+ (77.3%, 95% CI 65.3%–86.7%). In BF, HC2 was more sensitive for CIN2+/CIN3+ compared to VIA/VILI (relative sensitivity for CIN2+ = 1.72, 95% CI 1.28–2.32; CIN3+: 1.18, 95% CI 0.94–1.49). Triage of HC2-positive women with VIA/VILI reduced the number of colposcopy referrals, but with loss in sensitivity for CIN2+ (58.1%) but not for CIN3+ (84.6%). In SA, cytology high-grade squamous intraepithelial lesion or greater (HSIL+) had best combination of sensitivity (CIN2+: 70.1%, 95% CI 61.3%–77.9%; CIN3+: 80.8%, 95% CI 67.5%–90.4%) and specificity (81.6%, 95% CI 77.6%–85.1%). HC2 had similar sensitivity for CIN3+ (83.0%, 95% CI 70.2%–91.9%) but lower specificity compared to HSIL+ (42.7%, 95% CI 38.4%–47.1%; relative specificity = 0.57, 95% CI 0.52–0.63), resulting in almost twice as many referrals. Compared to HC2, triage of HC2-positive women with HSIL+ resulted in a 40% reduction in colposcopy referrals but was associated with some loss in sensitivity. CIN2+ incidence over a median 16 months was highest among VIA baseline screen-negative women (2.2%, 95% CI 1.3%–3.7%) and women who were baseline double-negative with HC2 and VIA (2.1%, 95% CI 1.3%–3.5%) and lowest among HC2 baseline screen-negative women (0.5%, 95% CI 0.1%–1.8%). Limitations of our study are that WLHIV included in the study may not reflect a contemporary cohort of WLHIV initiating ART in the universal ART era and that we did not evaluate HPV tests available in study settings today.ConclusionsIn this cohort study among WLHIV in Africa, a human papillomavirus (HPV) test targeting 14 high-risk (HR) types had higher sensitivity to detect CIN2+ compared to visual inspection but had low specificity, although a restricted genotype approach targeting 8 HR types decreased the number of unnecessary colposcopy referrals. Cytology HSIL+ had optimal performance for CIN2+/CIN3+ detection in SA. Triage of HPV-positive women with HSIL+ maintained high specificity but with some loss in sensitivity compared to HC2 alone.

In this cohort study, Helen Kelly and colleagues explore cervical cancer screening strategies for women living with HIV.  相似文献   

14.

Background

Circulating microRNA-21 (miR-21) is known to be aberrantly expressed in hepatocellular carcinoma (HCC) patients, and this implies that microRNA-21 is a promising and novel indicator of HCC. However, a systematic evaluation of the performance of microRNA-21 as a diagnostic marker for HCC has yet to be conducted. Therefore, the test performance of circulating miR-21 for HCC was assessed in this study.

Methods

Three common international databases and a Chinese electronic database were used to search for literature on the diagnostic accuracy of microRNA-21 for HCC. The pooled results included the sensitivity and specificity of microRNA-21 for HCC detection and were analyzed with a random effect model. The area under summary receiver operating characteristic curve (AUC) was used to estimate overall test performance.

Results

A total of 339 HCC patients and 338 controls without HCC from four published studies were eligible for the meta-analysis and included in our study. The test performance of circulating miR-21 in HCC detection was assessed with the summary estimates of sensitivity and specificity, which were 81.2% (95% CI: 70.8% to 88.4%) and 84.8% (95% CI: 75.1% to 91.2%), respectively. The value of AUC was 0.90 (95% CI: 0.87 to 0.92). Significant inter-study heterogeneity was detected by our analysis, and sub-group analyses suggested that the type of control group was probably a source of heterogeneity.

Conclusions

Our current findings suggested that circulating miR-21 can serve as a potential co-biomarker for early-stage HCC diagnosis. Thorough large-scale studies are needed to confirm the generalizability of our findings.  相似文献   

15.
Cancer patients spontaneously generate autoantibodies (AAb) to tumor-derived proteins. To detect AAb, we have probed novel high-density custom protein microarrays (NAPPA) expressing 4988 candidate tumor antigens with sera from patients with early stage breast cancer (IBC), and bound IgG was measured. We used a three-phase serial screening approach. First, a prescreen was performed to eliminate uninformative antigens. Sera from stage I-III IBC (n = 53) and healthy women (n = 53) were screened for AAb to all 4988 protein antigens. Antigens were selected if the 95th percentile of signal of cases and controls were significantly different (p < 0.05) and if the number of cases with signals above the 95th percentile of controls was significant (p < 0.05). These 761 antigens were screened using an independent set of IBC sera (n = 51) and sera from women with benign breast disease (BBD) (n = 39). From these, 119 antigens had a partial area under the ROC curve (p < 0.05), with sensitivities ranging from 9-40% at >91% specificity. Twenty-eight of these antigens were confirmed using an independent serum cohort (n = 51 cases/38 controls, p < 0.05). Using all 28 AAb, a classifier was identified with a sensitivity of 80.8% and a specificity of 61.6% (AUC = 0.756). These are potential biomarkers for the early detection of breast cancer.  相似文献   

16.
BackgroundDetection of lung cancer at an early stage by sensitive screening tests could be an important strategy to improving prognosis. Our objective was to identify a panel of circulating microRNAs in plasma that will contribute to early detection of lung cancer.ResultsWe identified a panel of 24 microRNAs with optimum classification performance. The combination of these 24 microRNAs alone could discriminate lung cancer cases from non-cancer controls with an AUC of 0.92 (95% CI: 0.87-0.95). This classification improved to an AUC of 0.94 (95% CI: 0.90-0.97) following addition of sex, age and smoking status to the model. Internal validation of the model suggests that the discriminatory power of the panel will be high when applied to independent samples with a corrected AUC of 0.78 for the 24-miRNA panel alone.ConclusionOur 24-microRNA predictor improves lung cancer prediction beyond that of known risk factors.  相似文献   

17.
18.
19.
Lung cancer remains the leading cause of cancer deaths in the developed world. There is no widely accepted method to screen for this cancer. The most commonly used method remains conventional sputum cytology, but this method is hampered by low sensitivity. We tested the hypothesis that sensitivity of sputum cytology for early lung cancer can be greatly improved by using image analysis of sputum cells, at a modest reduction of specificity.The study was double-blinded and used sputum samples from subjects with well-characterized clinical diagnoses. There were 177 cancers, 98 dysplasias, and 558 normals. The study samples were separated into two independent sets: training set and test set. Sputum samples were collected prospectively from subjects with a high probability of having lung cancer. Seven institutions from five countries participated in the study. All subjects had complete clinical diagnoses which included, as a minimum, negative chest x-rays for all negative cancers, while all cancers had confirmed tissue pathology. Samples were prepared according to the Saccomanno method. For conventional cytology, slides were stained using Papanicolaou stain. For image analysis, slides were stained using a DNA-specific (Feulgen-Thionin) stain. An automated, high-resolution image cytometer was used for measurements.At 90% specificity, sensitivity of 60% can be achieved for adenocarcinoma, compared to only 14% sensitivity of conventional cytology (at 99% specificity). Similarly, 45% sensitivity at 90% specificity can be reached for stages 0 and I lung cancer, compared to only 14% (at 99% specificity) using conventional cytology.Cytometry combined with conventional cytology shows an increase in sensitivity to early-stage cancer and to adenocarcinomas compared to conventional cytology alone. While the results are encouraging, the sensitivity to detect early lung cancer should be further improved to 70-80% at 90-95% specificity before this test can be considered for screening of high-risk individuals for lung cancer. Cytometry (Clin. Cytometry) 50:168-176, 2002.  相似文献   

20.
上海市区女性肺癌的家族聚集性研究   总被引:9,自引:1,他引:8  
我们利用在上海市区所开展的一项关于女性肺癌的较大规模人群基础上的病例对照研究资料,分析和评价了一级亲属患肺癌史者其在肺癌发生中的作用。文中重点分析了女性非吸烟者肺癌的材料。结果表明,先证者家系一级亲属患肺癌的风险性是对照组家系一级亲属的近3倍(OR=2.80,95% CI1.68-4.67)。对非吸烟先证者家系而言,比数比为2.62(95%CI1.52-4.5 2)。其中,腺癌、鳞癌、其他类和不明分类的肺癌的OR分别为2.79(95%CI 1.53-5.10)、3.88 (95%CI1.42-10.63)、1.26(95%CI0.27-6.01)、2.52 (95%CI1.16-5.49)。按年龄组分层分析的结果显示,35-59岁组与60-69岁组的比数比分别为4.01 (95%CI1.71-8.97)、 1.89(95%CI0.89-3.98)。非吸烟女性研究对象经多因素非条件logistic回归模型的分析后,比数比OR为2.71(95%CI1.54-4.76),有高度统计学意义。在该多变量回归模型的基础上估计的调整人群归因风险度为5.31%。 Abstract:The data set of a large population-based case-control study of female lung cancer conducted in Shanghai urban was used to investigate the contribution of lung cancer in first-degree relatives to lung cancer risk.The analysis in the paper is emphasized on non-smoking women.The results indicates that the risk of first-degree relatives with lung cancer is increased about 30fold(OR=2.80,95% CI:1.68-4.67),and for non-smoking probands the OR is 2.62(95% CI:1.52-4.52).The odds ratios of adeno-carcinoma,squamous cell carcinoma,others unknown of lung cancer are 2.79(95% CI:1.53-5.10),3.88(95% CI:1.42-10.63),1.26(95% CI:0.27-6.01),2.52(95% CI:1.16-5.49),respectively.For cases of age groups of 35 to 59 and 60 to 69 years of probands,with ORs of 4.01(95% CI:1.79-8.97)and 1.89(95% CI:0.89-3.98)respectively.The odds ratio from multivariable unconditional logistic regression is 2.71(95% CI:1.54-4.76).The estimation of adjusted population attributable risk is 5.31% based on the multivariable logistic regression model analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号