首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 648 毫秒
1.
The interpretation of the electromyogram (EMG) of dynamic contractions might be difficult because the movement per se introduces additional factors that could affect its characteristics. There is a lack of studies concerning the reproducibility of surface EMG registrations during dynamic contractions. The aim was to investigate the during-the-day reproducibility (using intra-class correlation; ICC) of the peak torque (PT) and the EMG variables (without removing the electrodes) of dynamic contractions. Ten healthy subjects performed three sets of 10 dynamic maximum right-knee extensions with a one-hour interval in between, using an isokinetic dynamometer and the PT was determined. EMG signals were recorded from the right vastus lateralis, rectus femoris and vastus medialis muscles using surface electrodes and the mean frequency of the power spectrum (MNF [Hz]) and the signal amplitude (RMS [microV]), were computed. The ability to relax in-between the maximum extensions was calculated as a ratio of the RMS during the passive flexion phase and the RMS during the active extension phase of each contraction cycle: the signal amplitude ratio (SAR). Both PT (ICC = 0.99) and RMS (ICC = 0.83-0.98) had good reproducibility. The reproducibility of MNF was good for all muscles when the mean of contraction nos.: 1-10 was used. Vastus lateralis had the highest ICC among the three muscles. The reproducibility of SAR was generally poor (ICC < 0.60). The present study showed good reproducibility for common EMG variables (MNF and RMS) obtained during maximum isokinetic contractions.  相似文献   

2.
A number of studies have been published that have used variables of the electromyogram (EMG) power spectrum during dynamic exercise. Despite these studies there is a shortage of studies of the validity of surface EMG registrations during repetitive dynamic contractions with respect to fatigue. The aim of this study was to investigate if the surface EMG variables mean frequency (MNF [Hz]) and the signal amplitude (RMS [microV]) are valid indicators of muscular fatigue (defined as "any exercise-induced reduction in the capacity to generate force or power output") during maximum repeated isokinetic knee extensions (i.e. criterion validity using peak torque). Twenty-one healthy volunteers performed 100 isokinetic knee extensions at 90 degrees s(-1). EMG signals were recorded from the vastus lateralis, the rectus femoris and the vastus medialis of the right thigh by surface electrodes. MNF and RMS of the EMG together with peak torque (PT [Nm]) were determined for each contraction. MNF showed consequently higher correlation coefficients with PT than RMS did. Positive correlations generally existed between MNF and PT. The majority of the subjects had positive correlations between RMS and PT (i.e. decreases both in PT and in RMS).In conclusion, at the individual level MNF generally - in contrast to RMS - showed good criterion validity with respect to biomechanical fatigue during dynamic maximum contractions.  相似文献   

3.
The continuous wavelet transform (CWT), a time-frequency method, was used when calculating mean frequency of the power spectrum (MNF) and signal amplitude (RMS) of the surface EMG to investigate their relationships to force during a gradually increasing knee extension (ramp). Based upon the CWT, MNF was redefined to include time dependence on the EMG signal frequency contents, the short-time MNF (STMNF). Surface EMG was recorded from vastus lateralis, rectus femoris and vastus medialis in 21 clinically healthy subjects during a brief, gradually increasing contraction up to 100% of a maximum voluntary contraction (MVC), with a duration of approximately 10 s. The relationships between the EMG variables and force using linear regression were determined for each subject. For vastus lateralis, we also investigated if certain aspects of the muscle morphology (i.e., proportions and areas of different fibre types) influenced the EMG-force relationship.For the majority of subjects (17-18 out of 21 subjects) there were significant positive correlations between STMNF and force in the three muscles. No sex differences were found in intercepts or regression coefficients of STMNF. The muscle morphology had a significant influence on the STMNF-force intercept and the regression coefficient. Positive and highly significant linear correlations between RMS and force were found for all subjects and all three muscles.In conclusion, time frequency methods can be applied when investigating EMG during brief contractions associated with non-stationarity. In a great majority of the subjects, and in the three muscles, significant linear force dependencies were found for STMNF. Thus, when evaluating muscle fatigue, e.g., in ergonomic situations, it is important to consider the force level as one factor that can influence the results. Morphological variables (fibre proportions and fibre areas) influenced the STMNF-force relationship in vastus lateralis.  相似文献   

4.
The aim of this study was to investigate the reliability of peak torque and surface electromyography (EMG) variable's root mean square (RMS) and mean frequency (MNF) during an endurance test consisting of repetitive maximum concentric knee extensions. Muscle fatigue has been quantified in several ways, and in isokinetic testing it is based on a set of repetitive contractions. To assess test-retest reliability, two sets of 100 dynamic maximum concentric knee extensions were performed using an isokinetic dynamometer. The two series were separated by 7-8 days. The subjects relaxed during the passive flexion phase. Twenty (10 men and 10 women) clinically healthy subjects volunteered.Peak torque and EMG from rectus femoris, vastus medialis, vastus lateralis and biceps femoris were recorded. RMS and MNF were calculated from the EMG signal. The reliability was calculated with intraclass correlation coefficient ICC (1.1) and standard error of measurements (SEM). The reliability of peak torque was good (ICC=0.93) and SEM showed low values. ICC was good for absolute RMS of rectus femoris (ICC>/=0.80), vastus medialis (ICC>/=0.88) and vastus lateralis (ICC>/=0.82) and MNF of rectus femoris (ICC>/=0.82) and vastus medialis (ICC>/=0.83). Peak torque, and MNF and RMS of rectus femoris and vastus medialis are reliable variables obtained from an isokinetic endurance test of the knee extensors.  相似文献   

5.
We aimed to investigate fatigue-induced changes in the spectral parameters of slow (SMF) and fast fatigable muscle fiber (FMF) action potentials using discrete wavelet (DWT) and fast Fourier (FFT) transforms. Intracellular potentials were recorded during repetitive stimulation of isolated muscle fibers immersed in Ca2+-enriched medium, while extracellular potentials were obtained from muscle fibers pre-exposed to electromagnetic microwaves (MMW, 2.45 GHz, 20 mW/cm2). The changes in the frequency distribution of the action potentials during the period of uninterrupted fiber activity were used as criteria for fatigue assessment. The wavelet coefficients’ changes in the calculated frequency scales demonstrated a contribution of the increased [Ca2+]0 to an earlier compression of the frequency spectrum towards lower ranges. Root mean square (RMS) analysis of the wavelet coefficients calculated from SMF potentials showed a reduction of the higher frequencies (scale 1) by 90% in elevated [Ca2+]0 vs. 55% in controls and an increase of low frequencies (scale 5) by 323% vs. 187%, respectively. For FMF potentials a decrease of 71% vs. 59% for high frequencies (scale 1, elevated [Ca2+]0 vs. control) and an increase of 386% vs. 295% in scale 5, respectively, were observed. MMW pre-exposure resulted in increased muscle fiber resistance to fatigue. The fatigue-induced decrease of potential high frequencies (SMF: 59% vs. 96%, MMW vs. control; FMF: 30% vs. 92%, respectively), and the increase of low frequencies (SMF: 200% vs. 207%, MMW vs. control; FMF: 93% vs. 314%, respectively) were significantly smaller and delayed in exposed muscle fibers. Data from RMS analysis indicate that DWT provides a reliable method for estimation of muscle fatigue onset and progression.  相似文献   

6.
J Applequist  B K Lunde 《Biopolymers》1974,13(7):1341-1346
The circular dichroic spectrum of poly(Tyr,TyrBr) in trimethylphosphate from 180 to 320 nm is found to be a linear function of composition from 25 to 68% TyrBr, and the spectra of the Tyr and TyrBr components are resolved. For Tyr the resolved spectrum is in agreement with available CD spectra of poly(Tyr). These results are interpreted to mean that the side-chain conformations of Tyr and TyrBr are not affected by the other component, and that for Tyr the conformation is the same as in poly(Tyr). It is also concluded that poly(Tyr,TyrBr) is helical with the same helix sense as poly(Tyr). The restrictions on the side-chain conformations are discussed, and it is suggested that the Tyr and TyrBr side chains are all in the same χ1 region.  相似文献   

7.
The purpose of the study was to explore changes in the spatial distribution of erector spinae electromyography amplitude during static, sustained contractions and during contractions of increasing load. Surface electromyographic (EMG) signals were detected from nine healthy subjects using a grid of 13 × 5 electrodes placed unilaterally over the lumbar erector spinae musculature. Subjects stood in a 20° forward flexed position and performed: (1) six 20-s long contractions with loads ranging from 2.5 kg to 12.5 kg (2.5 kg increments) and (2) a 6 min sustained contraction with 7.5 kg load. Root mean square (RMS) and mean power spectral frequency (MNF) were computed from the recorded EMG signals. EMG RMS increased (P < 0.0001) and MNF remained constant during contractions of increased load. During the sustained contraction, MNF decreased (P < 0.0001) and RMS did not change over time. The centroid (center of activity) of the RMS map shifted caudally (P < 0.0001) with time during the sustained contraction but did not change with varying load. These results suggest a change in the distribution of erector spinae muscle activity with fatigue and a uniform distribution of muscle activation across loads.  相似文献   

8.
9.
PurposeTo establish intra- and inter-session reliability of high-density surface electromyography (HDEMG)-derived parameters from the thoracic erector spinae (ES) during static and dynamic goal-directed voluntary movements of the trunk, and during functional reaching tasks.MethodsTwenty participants performed: 1) static trunk extension, 2) dynamic trunk forward and lateral flexion, and 3) multidirectional functional reaching tasks on two occasions separated by 7.5 ± 1.2 days. Muscle activity was recorded bilaterally from the thoracic ES. Root mean square (RMS), coordinates of the barycentre, mean frequency (MNF), and entropy were derived from the HDEMG signals. Reliability was determined with intraclass correlation coefficient (ICC), coefficient of variation, and standard error of measurement.ResultsGood-to-excellent intra-session reliability was found for all parameters and tasks (ICC: 0.79-0.99), whereas inter-session reliability varied across tasks. Static tasks demonstrated higher reliability in most parameters compared to functional and dynamic tasks. Absolute RMS and MNF showed the highest overall reliability across tasks (ICC: 0.66-0.98), while reliability of the barycentre was influenced by the direction of the movements.ConclusionRMS and MNF derived from HDEMG show consistent inter-session reliability in goal-directed voluntary movements of the trunk and reaching tasks, whereas the measures of the barycentre and entropy demonstrate task-dependent reliability.  相似文献   

10.
J Greve  M F Maestre  A Levin 《Biopolymers》1977,16(7):1489-1504
Circular dichroism (CD) spectra of poly(dA), poly(dT), poly(dA)·poly(dT), and poly[d(A-T)]·poly[d(T-A)] have been measured as a function of temperature. From these data difference spectra have been calculated by subtracting the spectrum measured at low temperature from the spectra measured at higher temperatures. The CD difference spectra obtained upon melting of the two double-stranded polymers are very similar. From a comparison of these difference spectra with calculated ones it is shown that optical transitions near 272 nm (on A) and 288 nm (most probably on T) are present. The premelting changes of the CD spectrum of poly[d(A-t)]·poly[d(T-A)] are due to a change in conformation in which the secondary structure goes from a C- to B-type spectrum by increasing the A-type nature of the polymer. Such a change is not observed for poly(dA)·poly(dT). Instead, a transition between two different B-type geometries occurs.  相似文献   

11.
OBJECTIVE: To analyze nuclear image morphometry in fine needle aspiration cytology smears of different groups of malignant round cell tumors (MRCTs) to evaluate its diagnostic role. STUDY DESIGN: In this study there were 55 cases of MRCT, consisting of 18 Ewing's sarcoma (EW), 10 neuroblastoma (NB), 5 non-Hodgkin's lymphoma (NHL), 6 rhabdomyosarcoma (RMS), 4 peripheral neuroectodermal tumor (PNET), 8 Wilm's tumor (WT), 2 retinoblastoma (RB) and 2 undifferentiated round cell tumor (URCT). A Leica image cytometer with Quantimet 600 software (Leica, Cambridge, U.K) was used to measure nuclear area, nuclear diameter, nuclear perimeter, nuclear convex perimeter (CP), nuclear roundness and nuclear convex area on hematoxylin and eosin-stained cytologic smears. At least 100 cells were studied in each case. RESULTS: The RB group of tumors showed the highest mean nuclear area (NA), convex area (CA), CP, diameter (D), perimeter (P) and roundness (R). RMS had the highest mean CA, and URCT had the highest mean roundness. ANOVA was performed on the tumors and showed significant differences for all the variables in all the groups (P < .000). All the morphometric data (except roundness) were significantly different in RMS versus all other MRCTs except RB. Similarly, morphometric data on WT were also significantly different from that on NHL. Most of the morphometric data (except CA and R) showed significant differences between RB and all other MRCTs except RMS. PNET, EW and NB could not be differentiated with those variables. CONCLUSION: RMS and RB could successfully be differentiated from all other MRCTs with the help of morphometry. It was not possible to differentiate RMS and RB by image cytometry (ICM) since the ICM data overlapped in those two groups. It was possible to differentiate WT and NHL with ICM. Nuclear ICM was not significantly different in the NB, PNET and ES groups, and probably ICM would not be very helpful to differentiate these groups of MRCT.  相似文献   

12.
Several metrics from nonlinear dynamics and statistical mechanics have been characterized on computer-generated number series with various signal-to-noise ratios, demonstrating their individual reliability as a function of sample size and their relationships to each other. The root mean square (RMS) evaluates amplitude, and the power spectral density (PSD) provides a visual display of the frequency spectrum; both measures have very high reliability even for an N as low as 50. The Fractal Dimension (D) is shown to converge rapidly and also to be reliable when N is as low as 50. These three measures (RMS, PSD, and D) have been applied to the complex kinetics of tyrosine hydroxylase time courses (50-point curves) at various BH4 concentrations (near physiological, but far from equilibrium levels). Recently developed measures of spectral entropy and the Liapunov Exponent, -lambda are also characterized.  相似文献   

13.
Frequency analysis of myoelectric (ME) signals, using the mean power spectral frequency (MNF), has been widely used to characterize peripheral muscle fatigue during isometric contractions assuming constant force. However, during repetitive isokinetic contractions performed with maximum effort, output (force or torque) will decrease markedly during the initial 40-60 contractions, followed by a phase with little or no change. MNF shows a similar pattern. In situations where there exist a significant relationship between MNF and output, part of the decrease in MNF may per se be related to the decrease in force during dynamic contractions. This study estimated force effects on the MNF shifts during repetitive dynamic knee extensions. Twenty healthy volunteers participated in the study and both surface ME signals (from the right vastus lateralis, vastus medialis, and rectus femoris muscles) and the biomechanical signals (force, position, and velocity) of an isokinetic dynamometer were measured. Two tests were performed: (i) 100 repetitive maximum isokinetic contractions of the right knee extensors, and (ii) five gradually increasing static knee extensions before and after (i). The corresponding ME signal time-frequency representations were calculated using the continuous wavelet transform. Compensation of the MNF variables of the repetitive contractions was performed with respect to the individual MNF-force relation based on an average of five gradually increasing contractions. Whether or not compensation was necessary was based on the shape of the MNF-force relationship. A significant compensation of the MNF was found for the repetitive isokinetic contractions. In conclusion, when investigating maximum dynamic contractions, decreases in MNF can be due to mechanisms similar to those found during sustained static contractions (force-independent component of fatigue) and in some subjects due to a direct effect of the change in force (force-dependent component of fatigue). In order to compare MNF shifts during sustained static and repetitive dynamic contractions it is necessary to estimate the force-dependent component of fatigue of dynamic contractions. Our results are preliminary and have to be confirmed in larger experiments using single dynamic contractions when determining the MNF-force relationship of the unfatigued situation.  相似文献   

14.
Mi D  Lin S  Blankenship RE 《Biochemistry》1999,38(46):15231-15237
Picosecond transient absorption difference spectroscopy in the blue wavelength region (380-500 nm) was used to study the early electron acceptors in photosystem I. Samples were photosystem I core particles with about 100 chlorophylls per reaction center isolated from the cyanobacterium Synechocystis sp. PCC 6803. After excitation at 590 nm at room temperature, decay-associated spectra (DAS) were determined from global analysis in the blue region, yielding two transient components and one nondecaying component. A 3 ps decay phase is interpreted as primarily due to antenna excited-state redistribution. A 28 ps decay phase is interpreted as due to overall excited-state decay by electron transfer. The nondecaying component is ascribed to the difference spectrum of P(700) and the quinone or A(1) electron acceptor (P(700)(+)A(1)(-) - P(700)A(1)). Decay curves on the millisecond time scale at different wavelengths were measured with an autoxidizable artificial electron acceptor, benzyl viologen, and the (P(700)(+) - P(700)) difference spectrum was constructed. The (A(1)(-) - A(1)) difference spectrum was obtained by taking the difference between the above two difference spectra. A parallel picosecond experiment under strongly reducing conditions was also done as a control experiment. These conditions stabilize the electron on an earlier acceptor, A(0). The nondecaying component of the DAS at low potential was assigned to (P(700)(+)A(0)(-) - P(700)A(0)) since the electron-transfer pathway from A(0) to A(1) was blocked. The [(P(700)(+)A(0)(-) - P(700)A(0)) - (P(700)(+) - P(700))] subtraction gives a spectrum, interpreted as the (A(0)(-) - A(0)) difference spectrum of a chlorophyll a molecule, consistent with previous studies. The (A(1)(-) - A(1)) spectrum resolved on the picosecond time scale shows significant differences with similar spectra measured on longer time scales. These differences may be due to electrochromic effects and spectral evolution.  相似文献   

15.
This study investigated possible motor unit (MU) firing patterns underlying changes in biceps brachii (BB) surface electromyographic (SEMG) activity in 96 participants who performed isometric actions of the elbow flexors at 40%, 60%, 80%, and 100% of maximum voluntary contraction (MVC). We also conducted a modeling investigation to determine the extent to which a model would fit the experimental results. Experimentally, there was a linear increase (277%; p < 0.01) in root-mean-square (RMS) amplitude with increasing force. The mean power frequency (MNF) remained stable from 40% to 80% of MVC, but there was a decrease (8.2%; p < 0.01) between 80% and 100% of MVC. A modeling approach was taken wherein well-known recruitment and rate-coding schemes activated MUs whose basic building block was the muscle fibre action potential. Two conditions were investigated: (1) an increase in firing rate (rate-coding) and (2) synchronization. The levels of rate-coding and synchronization were selected to produce a linear RMS–force relationship as observed in the experimental data. Then, the impact of these two strategies on changes in MNF was assessed. The MNF remained stable from 40% to 80% of maximum excitation for both the rate-coding and synchronization conditions. There was a decrease in MNF between 80% and 100% of maximum excitation for both modeling conditions, similar to that observed for the experimental data. Thus, at these high forces at which experimental data are technically difficult to obtain, the model supports the idea that both rate-coding and synchronization are responsible for the changes observed in surface EMG amplitude and frequency characteristics.  相似文献   

16.
17.
We have obtained the ultraviolet circular dichroism spectra of two repeating trinucleotide DNAs, poly [d(A-G-G).d(C-C-T)] and poly[d(A-A-G).d(C-T-T)], that have all purines on one strand and all pyrimidines on the other. These spectra, together with spectra of other synthetic polymers, can be combined to give 3 first-neighbor calculations of the spectrum of poly[d(A).d(T)] and 2 first-neighbor calculations of the spectrum of poly [d(G).d(C)]. The results show (1) that first-neighbor calculations utilizing only spectra of homopurine.homopyrimidine DNA sequences are no more accurate than are similar calculations that involve spectra of mixed purine-pyrimidine sequences, demonstrating that double-stranded homopurine.homopyrimidine sequences do not obviously belong to a special class of secondary conformations, and (2) that the wavelength region above 250 nm in the CD spectra of synthetic DNAs is least predictable from first-neighbor equations, probably because this region is especially sensitive to sequence-dependent conformational differences.  相似文献   

18.
The heme environments of Met(95) and His(77) mutants of the isolated heme-bound PAS domain (Escherichia coli DOS PAS) of a direct oxygen sensing protein from E. coli (E. coli DOS) were investigated with resonance Raman (RR) spectroscopy and compared with the wild type (WT) enzyme. The RR spectra of both the reduced and oxidized WT enzyme were characteristic of six-coordinate low spin heme complexes from pH 4 to 10. The time-resolved RR spectra of the photodissociated CO-WT complex had an iron-His stretching band (nu(Fe-His)) at 214 cm(-1), and the nu(Fe-CO) versus nu(CO) plot of CO-WT E. coli DOS PAS fell on the line of His-coordinated heme proteins. The photodissociated CO-H77A mutant complex did not yield the nu(Fe-His) band but gave a nu(Fe-Im) band in the presence of imidazole. The RR spectrum of the oxidized M95A mutant was that of a six-coordinate low spin complex (i.e. the same as that of the WT enzyme), whereas the reduced mutant appeared to contain a five-coordinate heme complex. Taken together, we suggest that the heme of the reduced WT enzyme is coordinated by His(77) and Met(95), and that Met(95) is displaced by CO and O(2). Presumably, the protein conformational change that occurs upon exchange of an unknown ligand for Met(95) following heme reduction may lead to activation of the phosphodiesterase domain of E. coli DOS.  相似文献   

19.
20.
Conjugal crosses with Pseudomonas aeruginosa donors carrying the CAM-OCT and RP4::Tn7 plasmids result in transfer of the Tn7 trimethoprim resistance (Tp(r)) determinant independently of RP4 markers. All Tp(r) exconjugants which lack RP4 markers have CAM-OCT genes and therefore must have received CAM-OCT::Tn7 plasmids formed by transposition of Tn7 from RP4::Tn7 to CAM-OCT. Most crosses yield exconjugants carrying mutant CAM-OCT plasmids which no longer determine either camphor or alkane utilization and thus appear to carry Tn7 inserts in the cam or alk loci, respectively. Transduction and reversion experiments indicated that at least 13 alkane-negative, camphor-positive, Tp(r) CAM-OCT::Tn7 plasmids carry an alk::Tn7 mutation. Determination of linkage between the alk mutation and the Tp(r) determinant of Tn7 on these plasmids is complicated by the presence of multiple copies of the Tn7 element in the genome. Generalized transduction will remove Tn7 from a CAM-OCT alk::Tn7 plasmid to yield alk(+) cells which carry no Tp(r) determinant on the CAM-OCT plasmid (as shown by transfer of the plasmid to a second strain). But the transduction to alk(+) does not remove all Tp(r) determinants from the genome of the recipient cell because the alkane-positive transductants remain trimethoprim resistant. Thus, it appears that copies of Tn7 can accumulate in the genome of P. aeruginosa (CAM-OCT alk::Tn7) strains without leaving their original site. This result is consistent with transposition models that involve replication of the transposable element without excision from the original site.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号