首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Injection of Xenopus oocytes is a technique widely used in studies of gene expression for both qualitative and quantitative analysis of DNA and mRNA. Published methods for controlling and assessing volumes transferred into oocytes are tedious, time consuming, and require considerable expertise. We describe the construction of an apparatus which automatically controls nanoliter injection volumes. For injection volumes from 50 to 10 nl, the mean volume injected into 10 oocytes was within 10% of the expected value and often better, and even for 1-nl injections was within 20% of the expected value. The precision of volume dispensing into individual oocytes decreased with decreasing volume; the standard deviation was about 10–15% of the mean for volumes in the 30- to 50-nl range and about 30–40% of the mean for volumes in the 1- to 2-nl range.  相似文献   

2.
A simple technique was elaborated for the measurement of muscle lactate concentration. It was tested on samples of muscle vastus lateralis taken by the Bergstr?m (1962) needle biopsy technique at the end of 20 min exercise bouts corresponding to 60-70% of Vo2 max. The biopsies were freshly frozen in liquid nitrogen, powdered and weighed in a cryostat at -20 degrees C. The extraction were made by saponine and the lactate measured in the saponine solution by an electrochemical-enzymatic method (LA 640). The results concern: the time of taking the biopsies and the freezing time (27 +/- 11 s and 34 +/- 9 s respectively); the accuracy of weighing (inducing a 1% uncertainty in the final result); a comparison of the saponine extraction with the perchloric acid extraction and a checking of the extraction capacity of the former; the accuracy of the whole measurement (the mean relative confidence limits are +/- 8-10%; the reproducibility of the technique through measurement of the variation coefficient (18%) calculated on measurements performed at a 15 days interval in 6 trained subjects. The discussion of the results and their comparison with those of the literature lead to the conclusion that the described method is suitable for muscle lactate measurements.  相似文献   

3.
The purpose of this study was to evaluate right ventricular (RV) loading and cardiac output changes, by using the thermodilution technique, during the mechanical ventilatory cycle. Fifteen critically ill patients on mechanical ventilation, with 5 cmH(2)O of positive end-expiratory pressure, mean respiratory frequency of 18 breaths/min, and mean tidal volume of 708 ml, were studied with help of a rapid-response thermistor RV ejection fraction pulmonary artery catheter, allowing 5-ml room-temperature 5% isotonic dextrose thermodilution measurements of cardiac index (CI), stroke volume (SV) index, RV ejection fraction (RVEF), RV end-diastolic volume (RVEDV), and RV end-systolic volume (RVESV) indexes at 10% intervals of the mechanical ventilatory cycle. The ventilatory modulation of CI and RV volumes varied from patient to patient, and the interindividual variability was greater for the latter variables. Within patients also, RV volumes were modulated more by the ventilatory cycle than CI and SV index. Around a mean value of 3.95 +/- 1.18 l. min(-1). m(-2) (= 100%), CI varied from 87.3 +/- 5.2 (minimum) to 114.3 +/- 5.1% (maximum), and RVESV index varied between 61.5 +/- 17.8 and 149.3 +/- 34.1% of mean 55.1 +/- 17.9 ml/m(2) during the ventilatory cycle. The variations in the cycle exceeded the measurement error even though the latter was greater for RVEF and volumes than for CI and SV index. For mean values, there was an inspiratory decrease in RVEF and increase in RVESV, whereas a rise in RVEDV largely prevented a fall in SV index. We conclude that cyclic RV afterloading necessitates multiple thermodilution measurements equally spaced in the ventilatory cycle for reliable assessment of RV performance during mechanical ventilation of patients.  相似文献   

4.
Fifteen anesthetized mechanically ventilated patients recovering from multiple trauma were studied to compare the effects of high-frequency jet ventilation (HFJV) and continuous positive-pressure ventilation (CPPV) on arterial baroreflex regulation of heart rate. Systolic arterial pressure and right atrial pressure were measured using indwelling catheters. Electrocardiogram (ECG) and mean airway pressure were continuously monitored. Lung volumes were measured using two linear differential transformers mounted on thoracic and abdominal belts. Baroreflex testing was performed by sequential intravenous bolus injections of phenylephrine (200 micrograms) and nitroglycerin (200 micrograms) to raise or lower systolic arterial pressure by 20-30 Torr. Baroreflex regulation of heart rate was expressed as the slope of the regression line between R-R interval of the ECG and systolic arterial pressure. In each mode of ventilation the ventilatory settings were chosen to control mean airway pressure and arterial PCO2 (PaCO2). In HFJV a tidal volume of 159 +/- 61 ml was administered at a frequency of 320 +/- 104 breaths/min, whereas in CPPV a tidal volume of 702 +/- 201 ml was administered at a frequency of 13 +/- 2 breaths/min. Control values of systolic arterial pressure, R-R interval, mean pulmonary volume above apneic functional residual capacity, end-expiratory pulmonary volume, right atrial pressure, mean airway pressure, PaCO2, pH, PaO2, and temperature before injection of phenylephrine or nitroglycerin were comparable in HFJV and CPPV. Baroreflex regulation of heart rate after nitroglycerin injection was significantly higher in HFJV (4.1 +/- 2.8 ms/Torr) than in CPPV (1.96 +/- 1.23 ms/Torr).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
Eleven adult ferrets (Mustela putorius furo) were anesthetized with ketamine hydrochloride (25 mg/kg, IM) and xylazine hydrochloride (2 mg/kg, IM). Fifteen minutes post-ketamine/xylazine injection, ferrets were treated with yohimbine hydrochloride at a dose of 0.5 mg/kg, or an equal volume of physiologic saline, intramuscularly. Each ferret served as its own control by randomly receiving both treatments with a minimum interval of 2 weeks between treatments on any one ferret. At 15 minutes post-ketamine/xylazine injection, mean heart rate measurements for both treatment groups were 27% less than the mean heart rate measurement reported for unanesthetized ferrets. Intramuscular administration of yohimbine antagonized the ketamine/xylazine induced bradycardia in 10 of the 11 ferrets, (p = 0.0001). In yohimbine treated ferrets, an increase in mean heart rate measurement was noted 5 minutes after the intramuscular administration of yohimbine, and followed, over the next 15 minutes, by a progressive increase in mean heart rate. However, a corresponding decrease in mean heart rate measurement was observed in saline treated controls. Fifteen minutes after the injection of yohimbine, the mean heart rate measurement of yohimbine treated animals had increased to 194 beats per minute. This mean heart rate measurement is nearly 30% greater than the mean heart rate of 150 beats per minute measured at 15 minutes post-saline injection in saline treated controls. Also, yohimbine treatment significantly reduced duration of recumbency in 10 of 11 ferrets (p = 0.0001). Mean duration of recumbency for yohimbine treated ferrets was 41 +/- 9.7 minutes, whereas mean duration of recumbency for saline treated ferrets was determined to be 80 +/- 11.4 minutes.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
T P Broten  J E Zehr  A Livnat 《Life sciences》1988,42(17):1625-1633
This study assessed the statistical validity of short time-interval measurements as estimators of true 24 hour mean arterial pressure in unanesthetized, unrestrained dogs. 24 hour intra-arterial pressure recordings were obtained using a stable FM telemetry system. The 24 hour pressure measurements approximated a normal distribution whose variance was inversely related to the selected averaging interval. Given the variance of a normal distribution one can calculate the 95% confidence interval for any single random measurement. Conversely the number of random samples necessary to be within a prescribed confidence interval can be determined. In this study, the 95% confidence interval for a single, random 30 minute arterial pressure average was calculated to be 11.2 mmHg. Only 4.8 +/- 1.4% of 480 individual 30 minute arterial pressure measurements fell beyond this confidence interval. These outlying values were distributed throughout the 24 hour period. The data suggest that randomly chosen short time-interval measurements may be a valid index of true 24 hour mean pressure if the average variance of a population is known and confidence intervals are defined.  相似文献   

7.
Aim of the study was to determine practicality and to test accuracy of a new calibration technique firstly introduced in 1998 by Schmid and Bess for biomechanical human tests. This technique enables three-dimensional calibration of camera positions as well as the calculation of internal and external camera parameters. It can be performed unlike other three-dimensional calibration techniques as the first with a planar calibration grid and only one single video image (of each camera) to calculate all 3-D reconstruction parameters. The tests were performed using two albavision ACAM G-Cameras with a resolution of 480 (h) by 420 (v) pixels. The achievable accuracy of distance measurements in recent commercially available motion measurement systems usually ranges from about 0.09% to 1.77% and higher. Accuracy of 0.0373% was determined with the new calibration technique. The 95% confidence interval ranged at +/- 0.02322 mm, the RMS (root mean square) error at 0.18776 mm. Better accuracy, easier and faster calibration are features of this new calibration technique. Required time for complete calibration ranged below one minute. Anticipating this new method will have good practicality in gait analysis or in research and industry due to increased accuracy and ease of use.  相似文献   

8.
A change in heart rate at a controlled submaximal exercise intensity is used as a marker of training status. However, the standard error of measurement has not been studied systematically, and therefore a change in heart rate, which can be considered relevant, has not been determined. Forty-four subjects (26.5 +/- 5.4 years; mean +/- standard deviation) participated in a submaximal running test at the same time of day for 5 consecutive days. Heart rates were determined during each of the 4 exercise intensities (2 minutes each) of increasing intensity and during the 1-minute recovery period after each stage. The repeatability of the heart rate on a day-to-day basis during the stages and recovery periods were high (intraclass correlation coefficient: 95% confidence interval R = 0.94- 0.99). The lowest variation in heart rate occurred in the fourth stage ( approximately 90% maximum heart rate) with heart rate varying 5 +/- 2 b.min(-1) (95% confidence interval for coefficient of variation = 1.1-1.4%). In conclusion, the standard error of measurement of submaximal heart rate is 1.1-1.4%. This magnitude of measurement error needs to be considered when heart rate is used as a marker of training status.  相似文献   

9.
Determination of the dog's splenic storage volume without surgical procedures requires measurement of both circulating and total red cell volumes. The estimation of circulating red cell volume by radioisotope techniques is impeded by the rapid uptake of tagged cells in the spleen. The circulating cell volume might be calculated from plasma volume and large vessel hematocrit, provided that the latter is corrected for the unequal distribution of red cells in the circulatory system. However, the correction factor can only be estimated in the splenectomized dog. We describe here a method to determine the factor in the intact dog, "physiologically splenectomized" by the severe exercise. The values obtained by this method slightly exceed those in the resting dog, as shown by studies in splenectomized exercising beagles in which splenic function was simulated by infusion of packed cells. The method was tested in beagles exercised by swimming and treadmill running and it was concluded that in the unanesthetized resting beagle about one-third of all erythrocytes is stored in the spleen. Labeled cells are equilibrated with about one-half of the splenic storage volume within 10 min after their injection. During maximal exertion the mean increase in large vessel hematocrit was 38.6 +/- 3.3%, the mean decrease in plasma volume 13.6 +/- 1.7% and the mean increase in plasma osmolarity 2.8 +/- 0.9% (percentages of control values).  相似文献   

10.
Differences in breast volume and contour are subjectively estimated by surgeons. 3D surface imaging using 3D scanners provides objective breast volume quantification, but precision and accuracy of the method requires verification. Breast volumes of five test individuals were assessed using a 3D surface scanner. Magnetic resonance imaging (MRI) reference volumes were obtained to verify and compare the 3D scan measurements. The anatomical thorax wall curvature was segmented using MRI data and compared to the interpolated curvature of the posterior breast volume delimitation of 3D scan data. MRI showed higher measurement precision, mean deviation (expressed as percentage of volume) of 1.10+/-0.34% compared to 1.63+/-0.53% for the 3D scanner. Mean MRI [right (left) breasts: 638 (629)+/-143 (138) cc] and 3D scan [right (left) breasts: 493 (497)+/-112 (116) cc] breast volumes significantly correlated [right (left) breasts: r=0.982 (0.977), p=0.003 (0.004)]. The posterior thorax wall of the 3D scan model showed high agreement with the MRI thorax wall curvature [mean positive (negative) deviation: 0.33 (-0.17)+/-0.37 cm]. High correspondence and correlation of 3D scan data with MRI-based verifications support 3D surface imaging as sufficiently precise and accurate for breast volume measurements.  相似文献   

11.
A pilot-scale pasteurizer operating under validated turbulent flow (Reynolds number, 11,050) was used to study the heat sensitivity of Mycobacterium avium subsp. paratuberculosis added to raw milk. The ATCC 19698 type strain, ATCC 43015 (Linda, human isolate), and three bovine isolates were heated in raw whole milk for 15 s at 63, 66, 69, and 72 degrees C in duplicate trials. No strains survived at 72 degrees C for 15 s; and only one strain survived at 69 degrees C. Means of pooled D values (decimal reduction times) at 63 and 66 degrees C were 15.0 +/- 2.8 s (95% confidence interval) and 5.9 +/- 0.7 s (95% confidence interval), respectively. The mean extrapolated D72 degrees C was <2.03 s. This was equivalent to a >7 log10 kill at 72 degrees C for 15 s (95% confidence interval). The mean Z value (degrees required for the decimal reduction time to traverse one log cycle) was 8.6 degrees C. These five strains showed similar survival whether recovery was on Herrold's egg yolk medium containing mycobactin or by a radiometric culture method (BACTEC). Milk was inoculated with fresh fecal material from a high-level fecal shedder with clinical Johne's disease. After heating at 72 degrees C for 15 s, the minimum M. avium subsp. paratuberculosis kill was >4 log10. Properly maintained and operated equipment should ensure the absence of viable M. avium subsp. paratuberculosis in retail milk and other pasteurized dairy products. An additional safeguard is the widespread commercial practice of pasteurizing 1.5 to 2 degrees above 72 degrees C.  相似文献   

12.
The osmotic permeability coefficient (Pf) was measured with a stopped- flow light-scattering technique. There is an artifactual light- scattering signal produced by the initial mixing that decays with a half-time of approximately 0.2 s. This seriously interferes with the measurement of the osmotically induced change in cell volume, which has a similar half-time. This "injection artifact" is associated with the biconcave shape of the cells. It is negligible for cells that have been made nearly spherical by swelling them in 160 mosmol. The dependence of this artifact on the cell volume may explain the previously observed dependence of Pf on the cell volume. When cells are made echinocytic (and therefore spherically symmetric), this injection artifact becomes negligible at all cell volumes and Pf can be accurately measured. The Pf of echinocytic cells was nearly constant, varying by less than 10% with the direction of flow and the medium osmolarity (160-360 mosmol). The average value of Pf was 2.0 X 10(-2) cm/s (T = 23 degrees C).  相似文献   

13.
The Coulter Counter Hypo-Osmotic Swelling test (CC-HOS) was developed to provide insight into the membrane integrity (relative volume shift Vr) of sperm necessary for fertilization, and to identify the optimum buffer needed for the X/Y chromosome sorting process. Using the CC-HOS test on neat bovine semen, the mean relative volume shift Vr for July and August was 1.20 and 1.14, respectively, whereas mean Vr values ranged from 1.32 to 1.41 during September to November. There was an inverse relationship between Vr magnitude and environmental temperature; we inferred that this enhanced sperm viability during autumn relative to summer. A method was developed to measure the dynamics of volume change of sperm in the buffer (pH 6.5) used for the X/Y chromosome sorting process. When exposed to the buffer (4 mM K+, 153 mM Na+, 140 mM Cl(-)), sperm from Bull C had a mean modal volume of 22.8+/-0.2 fL during a 0-300 s time interval, which did not significantly vary from sperm volumes (21.88+/-0.66 fL for Bull A and 22.46+/-0.38 fL for Bull B) noted in isotonic Isoton II solution. However, when exposed to lower ionic concentrations (2 mM K+, 62 mM Na+, 47 mM Cl-), the mean volume of Bull C sperm increased to 29.2+/-1.5 fL and exhibited slower rates toward stabilized volumes relative to higher ionic concentration buffers. Utilization of volume swelling measurements for measuring the impact of ion concentrations in X/Y chromosome sorting process buffers illustrated the importance of its application for emerging sperm-based biotechnologies.  相似文献   

14.
Removal of pleural liquid and protein by lymphatics in awake sheep   总被引:1,自引:0,他引:1  
The contribution of the parietal pleural lymphatics to pleural liquid and protein removal is unclear. We asked two questions. What is the rate of removal of sterile, artificial hydrothoraxes in awake sheep? What percentage is removed through parietal pleural lymphatics? Three days after the placement of a rib capsule in 18 sheep, we instilled a 10 ml/kg 1.0 g/dl autologous protein solution with labeled albumin and erythrocytes through the capsule into the pleural space. Erythrocytes were used as a marker for lymphatic flow. We measured terminal pleural liquid volume and radioactivity at periods from 2 to 48 h. In three sheep, we obtained a third volume measurement at 6 h by the volume of dilution technique. We found that hydrothorax removal could be described by a linear function with a constant rate: 0.28 +/- 0.01 ml.kg-1.h-1 (mean +/- SE) for the grouped data, and 0.20, 0.28, and 0.31 ml.kg-1.h-1 for the individual sheep. At 24 h, erythrocyte clearance was 89 +/- 16% (mean +/- SD) that of liquid and albumin clearance. We conclude that in awake sheep with large hydrothoraxes, pleural liquid and protein are removed at a rate of 0.28 +/- 0.01 ml.kg-1.h-1 (mean +/- SE) and lymphatics are responsible for at least 89% of this removal.  相似文献   

15.
To quantify the inhomogeneity of alveolar pressures (PA) during cyclic changes in lung volume similar to those present during spontaneous breathing, inhomogeneity of PA was measured with an alveolar capsule technique in six excised canine lungs. The lungs were ventilated by a quasi-sinusoidal pump with a constant end-expiratory lung volume and tidal volumes of 10, 20, and 40% of vital capacity at breathing frequencies ranging from 5 to 45 breaths/min. Inhomogeneity of PA was quantified as the sample standard deviation of pressures measured in three capsules. A component of inhomogeneity in phase with flow and a smaller component out of phase with flow were present. The in-phase component increased approximately linearly with flow. The ratio of inhomogeneity to flow was smaller at large tidal volumes and, at the two higher tidal volumes studied, the ratio was greater during inspiration than during expiration. If these data are interpreted in terms of a simple circuit model, this degree of inhomogeneity implies an approximately twofold variation in regional time constants. Despite these considerable differences in time constants, the absolute amount of inhomogeneity as defined by the sample standard deviation of the three PA's was small (maximum 0.57 +/- 0.32 cmH2O at the highest breathing frequency and tidal volume) because airway resistance in the canine lung was small.  相似文献   

16.
The conductance catheter method has substantially enhanced the characterization of in vivo cardiovascular function in mice. Absolute volume determination requires assessment of parallel conductance (V(p)) offset because of conductivity of structures external to the blood pool. Although such a determination is achievable by hypertonic saline bolus injection, this method poses potential risks to mice because of volume loading and/or contractility changes. We tested another method based on differences between blood and muscle conductances at various catheter excitation frequencies (20 vs. 2 kHz) in 33 open-chest mice. The ratio of mean frequency-dependent signal difference to V(p) derived by hypertonic saline injection was consistent [0.095 +/- 0.01 (SD), n = 11], and both methods were strongly correlated (r(2) = 0.97, P < 0.0001). This correlation persisted when the ratio was prospectively applied to a separate group of animals (n = 12), with a combined regression relation of V(p(DF)) = 1.1 * V(p(Sal)) - 2.5 [where V(p(DF)) is V(p) derived by the dual-frequency method and V(p(Sal)) is V(p) derived by hypertonic saline bolus injection], r(2) = 0.95, standard error of the estimate = 1.1 microl, and mean difference = 0.6 +/- 1.4 microl. Varying V(p(Sal)) in a given animal resulted in parallel changes in V(p(DF)) (multiple regression r(2) = 0.92, P < 0.00001). The dominant source of V(p) in mice was found to be the left ventricular wall itself, since surrounding the heart in the chest with physiological saline or markedly varying right ventricular volumes had a minimal effect on the left ventricular volume signal. On the basis of V(p) and flow probe-derived cardiac output, end-diastolic volume and ejection fraction in normal mice were 28 +/- 3 microl and 81 +/- 6%, respectively, at a heart rate of 622 +/- 28 min(-1). Thus the dual-frequency method and independent flow signal can be used to provide absolute volumes in mice.  相似文献   

17.
The blood loss that accompanies liposuction procedures has always been a concern. Tumescent injection of the targeted area of liposuction with dilute lidocaine and epinephrine solution has minimized intraoperative blood loss. Proponents of a newer ultrasonically assisted lipoplasty technique have claimed many benefits over traditional suction-assisted lipoplasty. However, few quantitative data are available on the intraoperative blood loss and the significance of postoperative anemia using the ultrasonic method. A prospective clinical observational design was used to investigate 38 patients undergoing suction-assisted lipoplasty and 37 patients undergoing ultrasound-assisted lipoplasty in whom the liposuction aspirate was expected to be more than 1000 ml. These patients were investigated with preoperative measurement of hemoglobin, platelet count, prothrombin time, partial thromboplastin time, and postoperative measurement of hemoglobin on the seventh postoperative day. In addition, hemoglobin concentration and whole blood volume were calculated from the infranatant portion of the liposuction aspirate. The mean +/- SD volume of the liposuction aspirate was 2901 +/- 1471 ml for suction-assisted compared with 2741 +/- 1086 ml for ultrasound-assisted lipoplasty. The mean +/- SD of whole blood volume in liposuction aspirate per case was 36 +/- 50.82 ml for suction-assisted lipoplasty and 36 +/- 28.62 ml for ultrasound-assisted lipoplasty. The mean +/- SD of the preoperative hemoglobin concentration was 13.93 +/- 0.99 g/dl for suction-assisted lipoplasty and 14.05 +/- 1.16 g/dl for ultrasound-assisted lipoplasty, whereas the mean +/- SD of the postoperative hemoglobin concentration was 13 +/- 1.42 g/dl for suction-assisted lipoplasty and 13.05 +/- 1.32 g/dl for ultrasound-assisted lipoplasty. The mean decrease in hemoglobin on the seventh postoperative day was 0.93 +/- 0.92 g/dl for suction-assisted lipoplasty and 1 +/- 0.64 g/dl for ultrasound-assisted lipoplasty. The volume of whole blood loss was estimated to be 12.4 ml in each 1000 ml of liposuction aspirate when using suction-assisted lipoplasty versus 13.1 ml when using ultrasound-assisted lipoplasty. All procedures were done under general anesthesia, and patients were discharged home on the same day. No blood transfusion was required. This study shows that blood loss using the ultrasonic technique is slightly higher, though insignificant, than when using suction. However, this study did not demonstrate a difference in the postoperative hemoglobin decrease between the two techniques.  相似文献   

18.
The constant-volume hypothesis regarding the four-chambered heart states that total pericardial volume remains invariant throughout the cardiac cycle. Previous canine studies have indicated that the pericardial volume remains constant within 5%; however, this hypothesis has not been validated in humans using state-of-the-art technology. The constant-volume hypothesis has several predictable functional consequences, including a relationship between atrial ejection fraction and chamber equilibrium volumes. Using cardiac magnetic resonance (MR) imaging (MRI), we measured the extent to which the constant-volume attribute of the heart is valid, and we tested the accuracy of the predicted relationship between atrial ejection fraction and chamber equilibrium volumes. Eleven normal volunteers and one volunteer with congenital absence of the pericardium were imaged using a 1.5-T MR scanner. A short-axis cine-loop stack covering the entire heart was acquired. The cardiac cycle was divided into 20 intervals. For each slice and interval, pericardial volumes were measured. The slices were stacked and summed, and total pericardial volume as a function of time was determined for each subject. In the normal subjects, chamber volumes at ventricular end diastole, end systole, and diastasis were measured. Pericardial volume remained invariant within 5 +/- 1% in normal subjects; maximum variation occurred near end systole. In the subject with congenital absence of the pericardium, total heart volume, defined by the epicardial surface, varied by 12%. The predictions of the relationship between atrial ejection fraction and chamber equilibrium volumes were well fit by MRI data. In normal subjects, the four-chambered heart is a constant-volume pump within 5 +/- 1%, and constant-volume-based modeling accurately predicts previously unreported physiological relationships.  相似文献   

19.
The application of left ventricular pressure-volume analysis to transgenic mice to characterize the cardiac phenotype has been problematic due to the small size of the mouse heart and the rapid heartbeat. Conductance technology has been miniaturized for the mouse and can solve this problem. However, there has been no validation of this technique. Accordingly, we performed echocardiography followed by simultaneous ultrasonic crystals, flow probe, and conductance studies in 18 CD-1 mice. Raw conductance volumes were corrected for an inhomogenous electrical field (alpha) and parallel conductance (G(pi)) yielding a stroke volume of 14.1 +/- 3.7 microliter/beat, end-diastolic volume of 20.8 +/- 6.5 microliter, and end-systolic volume of 9.0 +/- 5.8 microliter. The mean conductance volumes were no different from those derived by flow probe and echocardiography but did differ from ultrasonic crystals. G(pi) was determined to be 14.9 +/- 8.7 microliter. However, hypertonic saline altered dimension and pressure in the mouse left ventricle. Although G(pi) can be determined by the hypertonic saline method, saline altered hemodynamics, questioning its validity in the mouse. Although mean measures of absolute volume may be similar among different techniques, individual values did not correlate.  相似文献   

20.
Use of either urine or saliva samples to estimate extracellular water volume was investigated in 10 men using nonradioactive bromide (Br) and in seven newborn piglets using radioactive Br (82Br) and chloride (36Cl). The relation to Br to Cl concentrations in urine enabled an estimation of Br dilution volume from human urine (267 +/- 42 ml/kg, mean +/- SD) that was not significantly different (P = 1.0) from the Br dilution volume calculated from plasma Br concentration (268 +/- 20 ml/kg). Although the Br dilution volume estimated from saliva was not different from that of plasma, the error in the estimates of Br dilution volume from saliva was too large (mean difference, -36 +/- 64 ml/kg) to make its use practical. The data from piglets showed good agreement between 82Br and 36Cl dilution volumes calculated from 4-hr plasma samples (356 +/- 14 ml/kg and 347 +2- 12 ml/kg; P greater than 0.1) and between 82Br dilution volumes calculated from urine 82Br:36Cl and plasma 82Br (360 +/- 31 ml/kg and 356 +/- 14 ml/kg; P greater than 0.1). Extracellular water volume can be estimated in both adult and young animals using the Br dilution volume calculated from urine samples. It requires (i) two urine collections: one before and one 4 to 8 hr after administration of Br; (ii) a measurement or estimate of plasma Cl concentration; and (iii) a correction factor that describes the relationship of the ratio of Br to Cl in urine to that ratio in plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号