首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
In this study, we reported on the design of a multiplex real-time PCR assay based on SYBR Green I, incorporating dual priming adenine-thymine (AT)-rich primers for direct detection of MRSA from nasal samples. The multiplex real-time polymerase chain reaction (RT-PCR) assay reported in this study is based on SYBR Green I with incorporation of six dual priming AT-rich primers designed from the SCCmec/orf junction. A string (4–6 bp) of low-melting bases, such as adenine and thymine, was incorporated into the primers, which virtually divided a single primer in two functional regions, thus decreasing non-specific PCR products. The analytical sensitivity and specificity of the RT-PCR assay was determined with genomic DNA of reference strains (MRSA, MSSA, and MRCoNS). RT-PCR assay was performed for analysis of 72 nasal swab specimens, and the results were confirmed by use of a culture method. Furthermore, the results of RT-PCR were compared with LightCycler MRSA advance test. The multiplex RT-PCR assay reproducibly detected a minimum of 1 pg genomic DNA (31.5 copy of genome) of MRSA reference strains and clinical isolates, with a specific melting peak at 83.5 ± 1.5°C, and neither fluorescence nor a melting peak was detected in non-target isolates. The concordance rate between RT-PCR assay and culture method was 87.5% with Cohen's kappa value (κ) 0.75, which showed good agreement between the two assays. The sensitivity, specificity, positive predictive value, and negative predictive value of the assay were 93.5%, 82.9%, 80.5%, and 94.4%, respectively. In a comparative study for the detection of 72 nasal samples, the sensitivity, specificity, positive predictive value, and negative predictive value of the multiplex RT-PCR assay with respect to LightCycler MRSA advance test was 84.2%, 88.2%, 89%, and, 83.3%, respectively. The results of RT-PCR assay demonstrated high specificity (88.2%) and positive predictive value (89%) for the direct detection of MRSA from nasal samples.  相似文献   

2.
Human herpesvirus 5 (HHV-5, formerly known as CMV) is a beta-herpesvirus widely spread within a population. Thus, HHV-5 infections are a serious matter of concern in a group of immunocompromised patients. The goal of the study was modification and optimization of conventional PCR method developed for the detection of HHV-5 DNA to the real-time variant (RTmPCR) and determination of analytical resolution of the modified methods. Thirty plasma samples were tested for the presence of HHV-5 DNA using the LightCycler system with two different methods--one with SYBR Green I fluorochrome method and second one using TaqMan fluorescent probes and a qualitative in-house gel-stained PCR assay using primers that amplify part of HHV-5 MIE gene. The analytical sensitivity of real-time PCR assay was tested using serial dilutions of HHV-5 DNA in range between 10(0) and 10(-6). For comparison typical end-point detected PCR for cytomegalovirus detection with the same DNA dilutions was made. The sensitivity of novel method was about 100-fold higher than older one. Both LightCycler assays detected HHV-5 DNA in 27 samples, also which were negative by the gel-stained PCR. Analysis of the available clinical and serological data associated with these samples suggested that the real-time results in all of these cases were true positive. The conclusion is that real-time PCR methods are more sensitive than the conventional PCR used in this study. The additional sensitivity was valuable for detection of patients with low-copy viremia. The high level of sensitivity, specificity, accuracy, and rapidity provided by the LightCycler instrument are favorable for the use of this system in the detection of HHV-5 DNA in clinical specimens.  相似文献   

3.

Background

Methicillin-resistant Staphylococcus aureus (MRSA) nasal colonization among inpatients is a well-established risk factor for MRSA infection during the same hospitalization, but the long-term risk of MRSA infection is uncertain. We performed a retrospective cohort study to determine the one-year risk of MRSA infection among inpatients with MRSA-positive nasal polymerase chain reaction (PCR) tests confirmed by positive nasal culture (Group 1), patients with positive nasal PCR but negative nasal culture (Group 2), and patients with negative nasal PCR (Group 3).

Methodology/Principal Findings

Subjects were adults admitted to a four-hospital system between November 1, 2006 and March 31, 2011, comprising 195,255 admissions. Patients underwent nasal swab for MRSA PCR upon admission; if positive, nasal culture for MRSA was performed; if recovered, MRSA was tested for Panton-Valentine Leukocidin (PVL). Outcomes included MRSA-positive clinical culture and skin and soft tissue infection (SSTI). Group 1 patients had a one-year risk of MRSA-positive clinical culture of 8.0% compared with 3.0% for Group 2 patients, and 0.6% for Group 3 patients (p<0.001). In a multivariable model, the hazard ratios for future MRSA-positive clinical culture were 6.52 (95% CI, 5.57 to 7.64) for Group 1 and 3.40 (95% CI, 2.70 to 4.27) for Group 2, compared with Group 3 (p<0.0001). History of MRSA and concurrent MRSA-positive clinical culture were significant risk factors for future MRSA-positive clinical culture. Group 1 patients colonized with PVL-positive MRSA had a one-year risk of MRSA-positive clinical culture of 10.1%, and a one-year risk of MRSA-positive clinical culture or SSTI diagnosis of 21.7%, compared with risks of 7.1% and 12.5%, respectively, for patients colonized with PVL-negative MRSA (p = 0.04, p = 0.005, respectively).

Conclusions/Significance

MRSA nasal colonization is a significant risk factor for future MRSA infection; more so if detected by culture than PCR. Colonization with PVL-positive MRSA is associated with greater risk than PVL-negative MRSA.  相似文献   

4.
This prospective study compared PCR and culture techniques in the diagnosis of prosthetic joint infection (PJI). We obtained joint fluid samples (JFS; n=115) from patients who had failed total joint arthroplasty between January 2003 and June 2005; 49 were positive for PJI according to established strict criteria. JFS were analyzed by PCR (n=35; control n=66) or culture (n=46, control n=48). PCR was positive in 71% of PJI cases, resulting in sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and likelihood ratio for positive results as follows: 0.71; 0.97; 0.88; 0.93; 0.87 and 23.6, respectively. Culture was positive in 44% of PJI samples. Corresponding statistics were 0.44; 0.94; 0.69; 0.87; 0.63 and 7.0, respectively. Significantly higher sensitivity, accuracy and negative predictive values were calculated for PCR versus culture, and there was 83% concordance between the results of intraoperative culture and PCR detection of causative bacteria. Therefore, we conclude that PCR analysis of synovial fluid increases the utility of pre-operative aspiration for patients who require revision total joint surgery.  相似文献   

5.
The human polyomavirus BK (BKV) is wide-spread pathogen, associated with urogenital tract disorders or even nephropathy in immunosuppressed patients. Nowadays molecular detection by real-time PCR (qPCR) is recognized as a method-of-choice for detecting human polyomaviruses in clinical samples. The aim of the study was development of real-time PCR assay for detection and quantification of polyomavirus BK DNA in clinical samples, using specific primers targeting a viral DNA VP3 gene and a TaqMan hydrolyzing probe. The analytical sensitivity of assay was tested using serial dilutions of BKV DNA in range between 13500 and 15 copies/ml. 27 urine samples and 23 plasma samples taken from a group of 22 adult recipients of allogeneic HSCT were tested for the presence of polyomavirus BK in the LightCycler system. Described in-house real-time PCR assay detected BKV DNA in 8 specimens (6 urine and 2 plasma). Detected average viral load was 170 copies/ml for plasma and 1250 copies/ml for urine samples, respectively. The results of this study show that developed TaqMan-based probe qPCR assay is very reliable and valuable for detection and quantification of BKV DNA, both in urine and plasma samples. These data, combined with its rapid turnaround time for results and decreased hands-on time, make the LightCycler PCR assay highly suitable for the rapid diagnostics of polyomavirus BK infections in the clinical laboratory.  相似文献   

6.
The laboratory diagnosis of dermatophytosis is usually based on direct microscopic examination and culturing of clinical specimens. A commercial polymerase chain reaction kit (Dermatophyte PCR) has had favorable results when used for detection of dermatophytes and identification of Trichophyton rubrum in nail specimens. This study investigated the efficacy of the Dermatophyte PCR kit for detecting dermatophytosis in 191 hair or skin specimens from patients with suspected dermatophytosis. PCR was positive for 37 % of samples, whereas 31 and 39 % of the specimens were positive by culturing and direct microscopy, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value for PCR analysis were 83, 84, 71, and 91 %, respectively. The sensitivity of the PCR test was higher in specimens obtained from skin (88 %) than in those obtained from hair (58 %), while the specificity remained almost the same (84 and 86 % for skin and hair, respectively). Our results show that the Dermatophyte PCR kit is a promising diagnostic tool for detection of dermatophytosis in skin samples, providing clinicians with a rapid diagnosis.  相似文献   

7.
Colorectal cancer (CRC) is the second leading cause of cancer-related death in developed countries. Early detection of CRC leads to decreased CRC mortality. A blood-based CRC screening test is highly desirable due to limited invasiveness and high acceptance rate among patients compared to currently used fecal occult blood testing and colonoscopy. Here we describe the discovery and validation of a 29-gene panel in peripheral blood mononuclear cells (PBMC) for the detection of CRC and adenomatous polyps (AP). Blood samples were prospectively collected from a multicenter, case-control clinical study. First, we profiled 93 samples with 667 candidate and 3 reference genes by high throughput real-time PCR (OpenArray system). After analysis, 160 genes were retained and tested again on 51 additional samples. Low expressed and unstable genes were discarded resulting in a final dataset of 144 samples profiled with 140 genes. To define which genes, alone or in combinations had the highest potential to discriminate AP and/or CRC from controls, data were analyzed by a combination of univariate and multivariate methods. A list of 29 potentially discriminant genes was compiled and evaluated for its predictive accuracy by penalized logistic regression and bootstrap. This method discriminated AP >1cm and CRC from controls with a sensitivity of 59% and 75%, respectively, with 91% specificity. The behavior of the 29-gene panel was validated with a LightCycler 480 real-time PCR platform, commonly adopted by clinical laboratories. In this work we identified a 29-gene panel expressed in PBMC that can be used for developing a novel minimally-invasive test for accurate detection of AP and CRC using a standard real-time PCR platform.  相似文献   

8.
9.
目的:改进现有的检测表皮生长因子受体(EGFR)基因突变的荧光PCR法并开发出新的试剂盒,将其与直接测序法和ARMS法进行对比,验证该试剂盒用于临床诊断的敏感性、特异性和准确性。方法:收集2013年6月至2015年8月手术确诊的141例非小细胞肺癌(NSCLC)的石蜡包埋组织标本。采用盲法分别使用直接测序法、ARMS法和新试剂盒检测EGFR突变,比较新试剂盒与其他两种检测方法的差异,结果不一致时采用三种方法分别重复检验一次。结果:三种方法检测成功率均为100%,新试剂盒与直接测序法测得结果完全一致的比率达75.9%(107/141),在直接测序法测得的96例突变阳性中,92例在新试剂盒检测中得到验证(95.8%)。而直接测序法显示突变阴性的45例中,新试剂盒检测发现了23例突变阳性,两种检测方法的结果存在统计学差异(x2=40.745,P0.05)。与直接测序法进行比较,新试剂盒检测EGFR突变的敏感性、特异性分别为95.8%、48.9%,阳性预测值、阴性预测值分别为80.0%、84.6%,检测准确度为80.9%。以ARMS检测法为金标准,新试剂盒测得结果完全一致的比率达84.4%(119/141),两者的一致性比较好(K=0.749,P0.05),敏感性、特异性分别为94.1%、86.4%。结论:改进后EGFR基因突变检测的试剂盒在技术上较好地控制了检测结果的假阳性和假阴性,该检测方法较直接测序法具有更好的敏感性和准确性,与现有的ARMS法一致性较高。  相似文献   

10.
11.
Twelve (46%) of the 26 patients had human herpesvirus 6 (HHV-6) viremia after bone marrow transplant (BMT). All isolates were recovered from the samples obtained at 2 weeks after BMT. The sensitivity and the specificity of detection of viral DNA in plasma by qualitative polymerase chain reaction (PCR) for monitoring active virus replication were 92% and 97% respectively. Moreover, the positive (85%) and negative (99%) predictive values were also high. The patients with HHV-6 viremia showed a clear peak in HHV-6 DNA in peripheral blood mononuclear cells (PBMCs) at 2 weeks after BMT, which was measured by real time PCR. The virus DNA level in PBMCs between the two groups (patients with viremia and patients without viremia) was statistically different at 2 weeks after BMT (P = 0.033). In patients with HHV-6 viremia, mean HHV-6 DNA copy number was higher in the samples collected at 2 weeks after BMT than the samples collected at any other time period.  相似文献   

12.
A novel method, which involves a nested PCR in a single closed tube, was developed for the sensitive detection of Erwinia amylovora in plant material. The external and internal primer pairs used had different annealing temperatures and directed the amplification of a specific DNA fragment from plasmid pEA29. The procedure involved two consecutive PCRs, the first of which was performed at a higher annealing temperature that allowed amplification only by the external primer pair. Using pure cultures of E. amylovora, the sensitivity of the nested PCR in one tube was similar to that of a standard nested PCR in two tubes. The specificity and sensitivity were greater than those of standard PCR procedures that used a single primer pair. The presence of inhibitors in plant material, very common in E. amylovora hosts, is overcome with this system in combination with a simple DNA extraction protocol because it eliminates many of the inhibitory compounds. In addition, it needs a very small sample volume (1 microl of DNA extracted). With 83 samples of naturally infected material, this method achieved better results than any other PCR technique: standard PCR detected 55% of positive samples, two-tube nested PCR detected 71% of positive samples, and nested PCR in a single closed tube detected 78% of positive samples. When analyzing asymptomatic plant material, the number of positive samples detected by the developed nested PCR was also the highest, compared with the PCR protocols indicated previously (17, 20, and 25% of 251 samples analyzed, respectively). This method is proposed for the detection of endophytic and epiphytic populations of E. amylovora in epidemiological studies and for routine use in quarantine surveys, due to its high sensitivity, specificity, speed, and simplicity.  相似文献   

13.
14.
We combined real-time RT-PCR and real-time PCR (R/P) assays using a hydrolysis probe to detect Mycobacterium tuberculosis complex (MTBC)-specific 16S rRNA and its rRNA gene (rDNA). The assay was applied to 28 nonrespiratory and 207 respiratory specimens from 218 patients. Total nucleic acids (including RNA and DNA) were extracted from samples, and results were considered positive if the repeat RT-PCR threshold cycle was < or =35 and the ratio of real-time RT-PCR and real-time PCR load was > or =1.51. The results were compared with those from existing methods, including smear, culture, and real-time PCR. Following resolution of the discrepant results between R/P assay and culture, the overall sensitivity, specificity, positive predictive values (PPV), and negative predictive values (NPV) of all samples (including nonrespiratory and respiratory specimens) were 98.2%, 97.2%, 91.7%, and 99.4%, respectively, for R/P assay, and 83.9%, 89.9%, 72.3%, and 94.7%, respectively, for real-time PCR. Furthermore, the R/P assay of four patient samples showed a higher ratio before treatment than after several days of treatment. We conclude that the R/P assay is a rapid and accurate method for direct detection of MTBC, which can distinguish viable and nonviable MTBC, and thus may guide patient therapy and public health decisions.  相似文献   

15.
The need for rapid methods in order to precisely detect methicillin-resistant Staphylococcus aureus (MRSA) is extensively acknowledged. This study evaluated a quantitative real-time PCR assay targeting mecA (encoding high level resistance to methicillin) and femB (a specific genomic marker for S. aureus) genes to detect MRSA from broth culture, from serum seeded with MRSA and straight from the patient''s serum. One hundred and thirty-five clinical isolates of MRSA strains and different species were utilised in this study. In addition, a pilot study with 9 patients'' serum samples was performed. The sensitivity and specificity values for this assay were 99% and 100% respectively. The detection limit for this method was 1.23×102 CFU/ml from the serum seeded with MRSA cells and the limiting concentration of DNA for detection was 18 fg, which equates to 5.14 genomic DNA copies. In addition, this assay detected MRSA from patient''s serum (7 out of 9) with sensitivity of 77.8%. Overall, the assay was rapid, efficient, sensitive and easy to perform.  相似文献   

16.
Mycoplasma suis cannot be cultivated in vitro. Therefore, PCR-based methods are irreplaceable for the diagnosis of M. suis infections especially when clinical symptoms are not evident. Currently, no easy and reliable method allowing the quantitative detection of M. suis is available. This report describes the development of a quantitative LightCycler PCR assay based on the msg1 gene of M. suis (LC MSG1 PCR). No PCR signals were obtained with closely related haemotrophic and non-haemotrophic mycoplasmas, with other bacteria, and with M. suis-free blood and tissue arguing for a high analytical specificity. Test sensitivity was found to be 100%, and test specificity 96.7%. To test the diagnostic suitability of the LC MSG1 PCR, 25 pigs with clinical porcine eperythrozoonosis and 25 healthy pigs were investigated. All ill pigs revealed a positive real-time PCR result whereas only one healthy pig was detected to be M. suis-infected. M. suis was quantitatively detected in 19 blood specimens of 100 sows from Switzerland and in 17 of 160 post-weaning piglets from Germany. In conclusion, this new LC MSG1 PCR assay represents a powerful tool for the improvement of the current M. suis diagnosis and for prevalence and pathogenesis studies.  相似文献   

17.
【目的】为对当前爆发的手足口病进行快速准确的检测, 【方法】本研究建立了含内标的同时检测EV71和CA16的多重荧光RT-PCR方法,对该方法的特异性、灵敏度等进行评估,并对400多份临床样品进行了检测。【结果】实验结果表明,该检测方法特异性强,对10株EV71病毒、8株CA16病毒和25株其他人类病毒进行了检测,特异性为100%;该检测方法对EV71和CA16的检测灵敏度分别达到0.1 TCID50和1 TCID50;将0.1-104TCID50/ml EV71和CA16样本进行重复性实验,其变异系数分别为0.9-2.0%和0.9-2.3%。对400多份临床样品分别进行荧光RT-PCR检测和传统方法检测,结果显示,荧光RT-PCR对EV71和CA16的阳性检出率平均为46.1%和14.2%,比传统方法(34.5%和12.8%)的阳性检测率高。另外,实验数据显示,在粪便、直肠拭子、咽喉拭子样本中,PCR抑制物存在的比例为1.8%-3.4%,表明内标对监控PCR抑制物的存在具有重要作用。【结论】本方法能同时对EV71和CA16进行快速检测,并且灵敏度高,特异性好,由于加入了内标,能有效地监控假阴性的出现,适合于手足口病的临床检测。  相似文献   

18.
Contamination of hospital water systems with legionellae is a well-known cause of nosocomial legionellosis. We describe a new real-time LightCycler PCR assay for quantitative determination of legionellae in potable water samples. Primers that amplify both a 386-bp fragment of the 16S rRNA gene from Legionella spp. and a specifically cloned fragment of the phage lambda, added to each sample as an internal inhibitor control, were used. The amplified products were detected by use of a dual-color hybridization probe assay design and quantified with external standards composed of Legionella pneumophila genomic DNA. The PCR assay had a sensitivity of 1 fg of Legionella DNA (i.e., less than one Legionella organism) per assay and detected 44 Legionella species and serogroups. Seventy-seven water samples from three hospitals were investigated by PCR and culture. The rates of detection of legionellae were 98.7% (76 of 77) by the PCR assay and 70.1% (54 of 77) by culture; PCR inhibitors were detected in one sample. The amounts of legionellae calculated from the PCR results were associated with the CFU detected by culture (r = 0.57; P < 0.001), but PCR results were mostly higher than the culture results. Since L. pneumophila is the main cause of legionellosis, we further developed a quantitative L. pneumophila-specific PCR assay targeting the macrophage infectivity potentiator (mip) gene, which codes for an immunophilin of the FK506 binding protein family. All but one of the 16S rRNA gene PCR-positive water samples were also positive in the mip gene PCR, and the results of the two PCR assays were correlated. In conclusion, the newly developed Legionella genus-specific and L. pneumophila species-specific PCR assays proved to be valuable tools for investigation of Legionella contamination in potable water systems.  相似文献   

19.
Direct sequencing remains the most widely used method for the detection of epidermal growth factor receptor (EGFR) mutations in lung cancer; however, its relatively low sensitivity limits its clinical use. The objective of this study was to investigate the sensitivity of detecting an epidermal growth factor receptor (EGFR) mutation from peptide nucleic acid-locked nucleic acid polymerase chain reaction (PNA-LNA PCR) clamp and Ion Torrent Personal Genome Machine (PGM) techniques compared to that by direct sequencing. Furthermore, the predictive efficacy of EGFR mutations detected by PNA-LNA PCR clamp was evaluated. EGFR mutational status was assessed by direct sequencing, PNA-LNA PCR clamp, and Ion Torrent PGM in 57 patients with non-small cell lung cancer (NSCLC). We evaluated the predictive efficacy of PNA-LNA PCR clamp on the EGFR-TKI treatment in 36 patients with advanced NSCLC retrospectively. Compared to direct sequencing (16/57, 28.1%), PNA-LNA PCR clamp (27/57, 47.4%) and Ion Torrent PGM (26/57, 45.6%) detected more EGFR mutations. EGFR mutant patients had significantly longer progressive free survival (14.31 vs. 21.61 months, P = 0.003) than that of EGFR wild patients when tested with PNA-LNA PCR clamp. However, no difference in response rate to EGFR TKIs (75.0% vs. 82.4%, P = 0.195) or overall survival (34.39 vs. 44.10 months, P = 0.422) was observed between the EGFR mutations by direct sequencing or PNA-LNA PCR clamp. Our results demonstrate firstly that patients with EGFR mutations were detected more frequently by PNA-LNA PCR clamp and Ion Torrent PGM than those by direct sequencing. EGFR mutations detected by PNA-LNA PCR clamp may be as a predicative factor for EGFR TKI response in patients with NSCLC.  相似文献   

20.
Herpes simplex viruses types 1 and 2 are members of the Alphaherpesviridae subfamily, as they can infect both skin and nerves and develop latent infection within the dorsal root and trigeminal ganglia. Infections with these viruses are common worldwide and cause wide range of clinical syndromes. Although HSV-1/2 infect healthy children and adults, disease is more severe and extensive in the immunocompromised individuals and/or during neuroinfections. The aim of the study was development of real-time PCR assay for detection and differentiation of herpes simplex viruses type 1 and 2. DNA in clinical samples, using specific dual-channel HybProbe chemistry. The nalytical sensitivity of assay was tested using serial dilutions of HSV-1 and HSV-2 DNA in range between 10 degrees and 10(-5). (4.35 x 10(5)-4.00 x 10(2) copies/ml and 4.18 x 10(5)-3.82 x 10(2) copies/ml, respectively). Thirty four cell line isolates and sixteen clinical samples taken from a group of adult patients with neurological signs were tested for the presence of HSV-1/2 DNA in the LightCycler instrument. Described in-house real-time PCR assay detected herpesviral DNA in all cell line isolates (31 of them were HSV-1 positive; 3 were HSV-2 positive) and in 10 clinical samples (positive only for HSV-1). The conclusion is that developed HybProbe-based real-time PCR test is very reliable and valuable tool for detection and differentiation of HSV-1/2 viremia in different kind of samples. The high level of sensitivity and accuracy provided by this assay is favorable for the quantification of herpes simplex virus 1 and 2 DNA in clinical specimens, especially during low-copy infections.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号