首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A wire patch cell has been designed for exposing cell cultures during in vitro experiments studying possible effects of mobile radio telephone. It is based on the wire patch antenna which works at 900 MHz with a highly homogeneous field inside the antenna cavity. The designed cell structure is symmetric and provides a rather homogeneous field distribution in a large area around its centre. Moreover, the exposure cell can irradiate equally up to eight 35 mm Petri dishes at the same time, which enhances the statistical biological studies. To improve the specific absorption rate (SAR) homogeneity inside each sample, each dish is placed into another 50 mm dish. This way, SAR inhomogeneity is always proper for biological studies (below 30%). The main advantage of this new device is that it can provide SAR levels 20 times higher than those induced by classical Crawford transverse electromagnetic (TEM) cell. Moreover, this small open device is easy to construct and fits into an incubator. However, to be used for in vitro, the wire patch cell is a radiating element with the same radiating pattern as a dipole, and thus some absorbing materials are necessary around the system when used for in vitro experiments. Secondly, because of its narrow bandwidth, it is difficult to maintain its working frequency. To overcome this problem, a matching device is integrated into the test cell. In this paper, we present a detailed explanation of the cell behavior and dosimetric assessments for eight 35 mm Petri dishes exposed. Simulations using the Finite Difference Time Domain technique and experimental investigations have been carried out to design the cell at 900 MHz. The numerical dosimetry was validated by dosimetric measurements. These investigations estimated the dosimetric precision at 11%.  相似文献   

2.
A beam formed radiofrequency (RF) exposure-incubator employing a horn antenna, a dielectric lens, and a culture case in an anechoic chamber is developed for large scale in vitro studies. The combination of an open type RF exposure source and a culture case through which RF is transmitted realizes a uniform electric field (+/-1.5 dB) in a 300 x 300 mm area that accommodates 49 35 mm diameter culture dishes. This large culture dish area enables simultaneous RF exposure of a large number of cells or various cell lines. The RF exposure source operates at 2142.5 MHz corresponding to the middle frequency of the downlink band of the International Mobile Telecommunication 2000 (IMT-2000) cellular system. The dielectric lens, which has a gain of 7 dB, focuses RF energy in the direction of the culture case and provides a uniform electric field. The culture case is sealed and connected to the main unit for environmental control, located outside the anechoic chamber, via ducts. The temperature at the center of the tray, which contains the culture dishes in the culture room, is maintained at 37.0 +/- 0.2 degrees C by air circulation. In addition, the appropriate CO2 density and humidity supplied to the culture case realizes stable long-term culture conditions. Specific absorption rate (SAR) dosimetry is performed using an electric field measurement technique and the Finite Difference Time Domain (FDTD) calculation method. The results indicate that the mean SAR of the culture fluid at the bottom of the 49 (7 x 7 array) culture dishes used in the in vitro experiments is 0.175 W/kg for an antenna input power of 1 W and the standard deviation of the SAR distribution is 59%. When only 25 culture dishes (5 x 5 array) are evaluated, the mean SAR is 0.139 W/kg for the same antenna input power and the standard deviation of the SAR distribution is 47%. The proliferation of the H4 cell line in 72 h in a pair of RF exposure-incubators reveals that the culture conditions are equivalent to those of a common CO2 incubator.  相似文献   

3.
A sub‐acute electromagnetic field (EMF) biological effect study was carried out on rats exposed in the Transverse ElectroMagnetic exposure chamber at 171 MHz Continuous Wave (CW). The experiments involved three exposure levels (15, 25, and 35 V/m) for 15 days with triplicate parallel sham‐exposed controls in each series. All exposure conditions were simulated for the evaluation of the electromagnetic energy distribution and specific absorption rate (SAR) in the rat phantoms. Studies have shown a biphasic biological response depending on time and absorbed electromagnetic energy. Under low SAR, approximately 0.006 W/kg, EMF exposure leads to the stimulation of adrenal gland activity. This process is accompanied by an initial increase of daily excretion of corticosterone and Na+, which is seen as a higher Na+/K+ ratio, followed by a decrease of these parameters over time. It is possible that EMF exposure causes a stress response in animals, which is seen as an increased adrenal activity. Bioelectromagnetics. 2019;40:578–587. © 2019 Bioelectromagnetics Society.  相似文献   

4.
Shallow penetration of millimeter waves (MMW) and non‐uniform illumination in in vitro experiments result in a non‐uniform distribution of the specific absorption rate (SAR). These SAR gradients trigger convective currents in liquids affecting transient and steady‐state temperature distributions. We analyzed the effect of convection on temperature dynamics during MMW exposure in continuous‐wave (CW) and pulsed‐wave (PW) amplitude‐modulated regimes using micro‐thermocouples. Temperature rise kinetics are characterized by the occurrence of a temperature peak that shifts to shorter times as the SAR of the MMW exposure increases and precedes initiation of convection in bulk. Furthermore, we demonstrate that the liquid volume impacts convection. Increasing the volume results in earlier triggering of convection and in a greater cooling rate after the end of the exposure. In PW regimes, convection strongly depends on the pulse duration that affects the heat pulse amplitude and cooling rate. The latter results in a change of the average temperature in PW regime. Bioelectromagnetics. 2019;40:553–568. © 2019 Bioelectromagnetics Society.  相似文献   

5.
A novel exposure facility for exposing cell monolayers to centimeter and millimeter waves (18–40.5 GHz) used by future 5G mobile communication technology and similar applications has been developed. A detailed dosimetric characterization of the apparatus for frequencies of 27 and 40.5 GHz and 60 mm petri dishes, used in a presently ongoing study on human dermal fibroblasts and keratinocytes, was carried out. The exposure facility enables a well-defined, randomized, and blinded application of sham exposure and exposure with selectable values of incident power flux density, and additionally provides the possibility of continuous monitoring of the sample temperature during exposure while it does not require significant deviations from routine in vitro handling procedures, i.e. petri dishes are not required to be placed inside waveguides or TEM cells. Mean specific absorption rate (SAR) values inside the cell monolayer of 115 W/kg (27 GHz) and 160 W/kg (40.5 GHz) per watt antenna input power and corresponding transmitted power density (St) values at the bottom of the cell monolayer of 65 W/m2 (27 GHz) and 70 W/m2 (40.5 GHz) per watt antenna input power can be achieved, respectively. For reasonable amounts of harvested cells (80% of petri dish bottom area), the variation (max/min) of SAR and St over the cell monolayer remains below 3.7 dB (27 GHz) and 3.0 dB (40.5 GHz), respectively. © 2021 Bioelectromagnetics Society.  相似文献   

6.
In occupational environments, an increasing number of electromagnetic sources emitting complex magnetic field waveforms in the range of intermediate frequencies is present, requiring an accurate exposure risk assessment with both in vitro and in vivo experiments. In this article, an in vitro exposure system able to generate complex magnetic flux density B‐fields, reproducing signals from actual intermediate frequency sources such as magnetic resonance imaging (MRI) scanners, for instance, is developed and validated. The system consists of a magnetic field generation system and an exposure apparatus realized with a couple of square coils. A wide homogeneity (99.9%) volume of 210 × 210 × 110 mm3 was obtained within the coils, with the possibility of simultaneous exposure of a large number of standard Petri dishes. The system is able to process any numerical input sequence through a filtering technique aimed at compensating the coils' impedance effect. The B‐field, measured in proximity to a 1.5 T MRI bore during a typical examination, was excellently reproduced (cross‐correlation index of 0.99). Thus, it confirms the ability of the proposed setup to accurately simulate complex waveforms in the intermediate frequency band. Suitable field levels were also attained. Moreover, a dosimetry index based on the weighted‐peak method was evaluated considering the induced E‐field on a Petri dish exposed to the reproduced complex B‐field. The weighted‐peak index was equal to 0.028 for the induced E‐field, indicating an exposure level compliant with the basic restrictions of the International Commission on Non‐Ionizing Radiation Protection. Bioelectromagnetics 34:211–219, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

7.
This paper presents the design of a resonant system for in vitro studies to emulate the exposure of a monolayer of cells to a wireless power transfer system operating at 13.56 MHz. The design procedure targets a system, which maximizes the specific absorption rate (SAR) uniformity on the plane where the layer is cultured, as well as SAR efficiency (defined as SAR over the input power), within the size constraints of a standard incubator. Three resonant wireless power transfer systems with different commonly used loop/coil geometries (cylindrical with circular and square cross-sections and annular) were compared with assess the configuration maximizing the considered design criteria. The system performance in terms of reflection and transmission coefficients, as well as generated E- and H-fields, was characterized numerically and experimentally inside the incubator. Moreover, SAR was computed at the monolayer level. The system equipped with cylindrical coils with square cross-sections led to a high electromagnetic field uniformity in in vitro biological samples. In particular, the uniformities in E and SAR at the layer level were within 7.9% and 5.5%, respectively. This was achieved with the variation in H below the usually considered ±5% limit. © 2020 Bioelectromagnetics Society  相似文献   

8.
Due to the expected mass deployment of millimeter‐wave wireless technologies, thresholds of potential millimeter‐wave‐induced biological and health effects should be carefully assessed. The main purpose of this study is to propose, optimize, and characterize a near‐field exposure configuration allowing illumination of cells in vitro at 60 GHz with power densities up to several tens of mW/cm2. Positioning of a tissue culture plate containing cells has been optimized in the near‐field of a standard horn antenna operating at 60 GHz. The optimal position corresponds to the maximal mean‐to‐peak specific absorption rate (SAR) ratio over the cell monolayer, allowing the achievement of power densities up to 50 mW/cm2 at least. Three complementary parameters have been determined and analyzed for the exposed cells, namely the power density, SAR, and temperature dynamics. The incident power density and SAR have been computed using the finite‐difference time‐domain (FDTD) method. The temperature dynamics at different locations inside the culture medium are measured and analyzed for various power densities. Local SAR, determined based on the initial rate of temperature rise, is in a good agreement with the computed SAR (maximal difference of 5%). For the optimized exposure setup configuration, 73% of cells are located within the ±3 dB region with respect to the average SAR. It is shown that under the considered exposure conditions, the maximal power density, local SAR, and temperature increments equal 57 mW/cm2, 1.4 kW/kg, and 6 °C, respectively, for the radiated power of 425 mW. Bioelectromagnetics 33:55–64, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

9.
A head exposure setup for efficient and precisely defined exposure of human subjects equipped with a near‐infrared imaging (NIRI) sensor is presented. In a partially shielded anechoic chamber the subjects were exposed to Universal Mobile Telecommunications System (UMTS)‐like electromagnetic fields (EMF) by using a patch antenna at a distance of 4 cm from the head. The non‐contact design of the exposure setup enabled NIRI sensors to easily attach to the head. Moreover, different regions of the head were chosen for localised exposure and simultaneous NIRI investigation. The control software enabled the simple adaptation of the test parameters during exploratory testing as well as the performance of controlled, randomised, crossover and double‐blind provocation studies. Four different signals with a carrier frequency of 1900 MHz were chosen for the exposure: a simple continuous wave signal and three different UMTS signals. Furthermore, three exposure doses were available: sham, low (spatial peak specific absorption rate (SAR) = 0.18 W/kg averaged over 10 g) and high (spatial peak SAR = 1.8 W/kg averaged over 10 g). The SAR assessment was performed by measurement and simulation. Direct comparison of measurement and numerical results showed good agreement in terms of spatial peak SAR and SAR distribution. The variability analysis of the spatial peak SAR over 10 g was assessed by numerical simulations. Maximal deviations of ?22% and +32% from the nominal situation were observed. Compared to other exposure setups, the present setup allows for low exposure uncertainty, combined with high SAR efficiency, easy access for the NIRI sensor and minimal impairment of test subjects. Bioelectromagnetics 33:124–133, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

10.
In this article, the exposure to radio frequency electromagnetic fields was studied in close proximity (distances of 10, 100, 300, and 600 mm) to six base station antennas. The specific absorption rate (SAR) in 800 mm × 500 mm × 200 mm box phantom as well as unperturbed electric field (E) in air was measured. The results were used to determine whether the measurement of local maximum of unperturbed electric field can be used as a compliance check for local exposure. Also, the conservativeness of this assessment method compared to the ICNIRP basic restriction was studied. Moreover, the assessment of whole‐body exposure was discussed and the distance ranges presented in which the ICNIRP limit for local exposure could be exceeded before the limit for whole‐body SAR. These results show that the electric field measurement alone can be used for easy compliance check for the local exposure at all distances and for all antenna types studied. However, in some cases when the local peak value of E was compared directly to the ICNIRP reference level for unperturbed E, the exposure was overestimated only very slightly (by factor 1.1) compared to the basic restriction for localized SAR in a human, and hence these results can not be generalized to all antenna types. Moreover, it was shown that the limit for localized exposure could be exceeded before the limit for the whole‐body average SAR, if the distance to the antenna was less than 240 mm. Bioelectromagnetics 30:307–312, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

11.
Despite much research, gaps remain in knowledge about the potential health effects of exposure to radiofrequency (RF) fields. This study investigated the effects of early‐life exposure to pulsed long term evolution (LTE) 1,846 MHz downlink signals on innate mouse behavior. Animals were exposed for 30 min/day, 5 days/week at a whole‐body average specific energy absorption rate (SAR) of 0.5 or 1 W/kg from late pregnancy (gestation day 13.5) to weaning (postnatal day 21). A behavioral tracking system measured locomotor, drinking, and feeding behavior in the home cage from 12 to 28 weeks of age. The exposure caused significant effects on both appetitive behaviors and activity of offspring that depended on the SAR. Compared with sham‐exposed controls, exposure at 0.5 W/kg significantly decreased drinking frequency (P ≤ 0.000) and significantly decreased distance moved (P ≤ 0.001). In contrast, exposure at 1 W/kg significantly increased drinking frequency (P ≤ 0.001) and significantly increased moving duration (P ≤ 0.005). In the absence of other plausible explanations, it is concluded that repeated exposure to low‐level RF fields in early life may have a persistent and long‐term effect on adult behavior. Bioelectromagnetics. 2019;40:498–511. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.  相似文献   

12.
Several authors have reported that the meniscus as occurring at the walls of Petri dishes and flasks (solid-liquid interface) can significantly affect the SAR distribution in the entire dish and flask, while others have ignored this effect. In this study, this effect has been comprehensively analyzed by numerical means supported by theoretical considerations. The focus is on E polarization, which results in the most homogeneous exposure for monolayer cell cultures and therefore is the most often applied polarization in exposure setups for risk assessment studies. This includes setups based on TEM cells, waveguides, radial transmission lines (RTL), and HF chambers. The conclusion of this study is that the meniscus and its size have a significant effect on the strength and homogeneity of the induced SAR distribution. Hence, the meniscus needs to be accounted for in the determination of the averaged SAR as well as in the uncertainty assessment. It has also been demonstrated that a voxel size of less than 0.2 mm is needed to predict the SAR values for a monolayer of cells accurately.  相似文献   

13.
In a previous article we developed an in vitro 23 kHz magnetic field (MF) exposure system that generated an MF of 532 µTrms. Using this system, the biological effects of 23 kHz MFs on cell functions have been reported. To further clarify the biological effect of intermediate‐frequency (IF) MFs and investigate the dose–response relationship in cell lines, an exposure system that generates stronger MFs is required. To meet this requirement, we developed a 6.25 mTrms MF exposure system for in vitro study. This level is 1000 times the reference level for the general public in the ICNIRP guidelines. This system provides an MF of 6.25 mTrms at 23 kHz with a uniformity within ±5%. To verify that in vitro experimental conditions are maintained, we examined the temperature, environmental MF, and MF leakage for a sham exposure system. In addition, we examined the harmonics, coil shape, and heat generated in the medium by the high‐strength MF. As a result, it was confirmed that this system can be used to evaluate the biological effects of IF MFs. This article presents the design and successful construction of the in vitro exposure system. Bioelectromagnetics 31:156–163, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

14.
This study investigates occupational exposure to electromagnetic fields in front of a multi‐band base station antenna for mobile communications at 900, 1800, and 2100 MHz. Finite‐difference time‐domain method was used to first validate the antenna model against measurement results published in the literature and then investigate the specific absorption rate (SAR) in two heterogeneous, anatomically correct human models (Virtual Family male and female) at distances from 10 to 1000 mm. Special attention was given to simultaneous exposure to fields of three different frequencies, their interaction and the additivity of SAR resulting from each frequency. The results show that the highest frequency—2100 MHz—results in the highest spatial‐peak SAR averaged over 10 g of tissue, while the whole‐body SAR is similar at all three frequencies. At distances >200 mm from the antenna, the whole‐body SAR is a more limiting factor for compliance to exposure guidelines, while at shorter distances the spatial‐peak SAR may be more limiting. For the evaluation of combined exposure, a simple summation of spatial‐peak SAR maxima at each frequency gives a good estimation for combined exposure, which was also found to depend on the distribution of transmitting power between the different frequency bands. Bioelectromagnetics 32:234–242, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

15.
A new head exposure system for double‐blind provocation studies investigating possible effects of terrestrial trunked radio (TETRA)‐like exposure (385 MHz) on central nervous processes was developed and dosimetrically analyzed. The exposure system allows localized exposure in the temporal brain, similar to the case of operating a TETRA handset at the ear. The system and antenna concept enables exposure during wake and sleep states while an electroencephalogram (EEG) is recorded. The dosimetric assessment and uncertainty analysis yield high efficiency of 14 W/kg per Watt of accepted antenna input power due to an optimized antenna directly worn on the subject's head. Beside sham exposure, high and low exposure at 6 and 1.5 W/kg (in terms of maxSAR10g in the head) were implemented. Double‐blind control and monitoring of exposure is enabled by easy‐to‐use control software. Exposure uncertainty was rigorously evaluated using finite‐difference time‐domain (FDTD)‐based computations, taking into account anatomical differences of the head, the physiological range of the dielectric tissue properties including effects of sweating on the antenna, possible influences of the EEG electrodes and cables, variations in antenna input reflection coefficients, and effects on the specific absorption rate (SAR) distribution due to unavoidable small variations in the antenna position. This analysis yielded a reasonable uncertainty of <±45% (max to min ratio of 4.2 dB) in terms of maxSAR10g in the head and a variability of <±60% (max to min ratio of 6 dB) in terms of mass‐averaged SAR in different brain regions, as demonstrated by a brain region‐specific absorption analysis. Bioelectromagnetics 33:594–603, 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

16.
Zhao J  Wei Z 《Bioelectromagnetics》2005,26(6):481-488
Experimental studies on effects of millimeter wave (MMW) exposure on cells cultured in Petri dishes have attracted interest in recent decades. To improve the quantification of the biological responses toward the MMW energy, an accurate and precise MMW dosimetry is to be provided. By using the finite difference time domain (FDTD) method, the numerical dosimetry is performed for a typical 35 mm Petri dish under 46 GHz continuous MMW exposure from an irradiator of a specified power pattern. With the aim of building a precise model, the meniscus at the interface between the culture solution and the Petri dish sidewall is taken into account, followed by the modeling of smooth edges of the Petri dish. The trilinear interpolation is introduced to assist the FDTD method to obtain a more precise dosimetric assessment. The specific absorption rate (SAR) distributions in the cornea cells covered by culture solution in the Petri dish are calculated and compared to display the effects of using Petri dish models of various precision and the trilinear interpolation on dosimetry results. In addition, the SAR distribution in the cells is analyzed to study its homogeneity. The results indicate that the precise Petri dish model and the application of the trilinear interpolation are helpful in improving the precision of numerical dosimetry. It is also revealed that the inhomogeneity of the SAR distribution is well beyond neglect, which deserves cautious consideration in experiments investigating MMW effects on cells in vitro.  相似文献   

17.
An applicator for in vitro cell culture exposure was developed based on a circularly polarized, cylindrical waveguide for the 1.9-GHz frequency band used by Personal Communications Services (PCS) in Canada. The applicator consists of two coaxial Petri dishes that sit on the open end of the cylindrical waveguide. The inner 60-mm Petri dish contains the cell culture while the outer 150-mm dish contains coolant water, which is circulated from a pump. A dosimetric evaluation was made using thermometric and E-field probe techniques. The latter allowed the entire inner dish to be scanned to determine the range of specific absorption rates (SARs) pertinent to the expected position of the cells. A representative SAR rate (SAR per unit of input power) of 8.6 +/- 2.1 W/kg/W (95th percentile) was determined 1 mm from the bottom, for a 10 ml sample volume of standard medium. Evaluation of the cooling system demonstrated that following an initial 0.3 degrees C temperature increase, a constant temperature was maintained for 24 h when the waveguide was energized to achieve an average sample SAR of 10 W/kg. These properties enable both acute and sub-acute in vitro bio-effect studies to be performed on a variety of cell culture samples.  相似文献   

18.
Wireless wearable and implantable devices are continuing to grow in popularity, and as this growth occurs, so too does the need to consider the safety of such devices. Wearable and implantable devices require the transmitting and receiving of electromagnetic waves near and through the body, which at high enough exposure levels may damage proximate tissues. The specific absorption rate (SAR) is the quantity commonly used to enumerate exposure levels, and various national and international organizations have defined regulations limiting exposure to ensure safe operation. In this paper, we comprehensively review dosimetric studies reported in the literature up to the year 2019 for wearables and implants. We discuss antenna designs for wearables and implants as they relate to SAR values and field and thermal distributions in tissue, present designs that have made steps to reduce SAR, and then review SAR considerations as they relate to applied devices. As compared with previous review papers, this paper is the first review to focus on dosimetry aspects relative to wearable and implantable devices. Bioelectromagnetics. 2020;41:3–20 © 2019 The Authors. Bioelectromagnetics published by Wiley Periodicals, Inc.  相似文献   

19.
A new head exposure system for double-blind provocation studies investigating possible effects of 2.45 GHz Wi-Fi exposure on human sleep was developed and dosimetrically analyzed. The exposure system includes six simultaneously radiating directional antennas arranged along a circle (radius 0.6 m) around the test subject's head, and enables a virtually uniform head exposure, i.e. without any preferred direction of incidence, during sleep. The system is fully computer-controlled and applies a real wireless local area network (WLAN) signal representing different transmission patterns as expected in real WLAN scenarios, i.e. phases of “beacon only” as well as phases of different data transmission rates. Sham and verum are applied in a double-blind crossover study design and all relevant exposure data, i.e. forward and reverse power at all six antenna inputs, are continuously recorded for quality control. For a total antenna input power (sum of all antennas) of 220 mW, typical specific absorption rate (SAR) in cortical brain regions is approximately 1–2 mW/kg (mass average SAR over respective brain region), which can be seen as a realistic worst-case exposure level in real WLAN scenarios. Taking into account variations of head positions during the experiments, the resulting exposure of different brain regions may deviate from the given average SAR levels up to 10 dB. Peak spatial 10 g average SAR in all brain and all head tissues is between 1.5–3.5 and 10.4–25 mW/kg, respectively. Bioelectromagnetics. © 2020 Bioelectromagnetics Society.  相似文献   

20.
The aim of this project was to develop an animal exposure system for the biological effect studies of radio frequency fields from handheld wireless telephones, with energy deposition in animal brains comparable to those in humans. The finite‐difference time‐domain (FDTD) method was initially used to compute specific absorption rate (SAR) in an ellipsoidal rat model exposed with various size loop antennas at different distances from the model. A 3 × 1 cm rectangular loop produced acceptable SAR patterns. A numerical rat model based on CT images was developed by curve‐fitting Hounsfield Units of CT image pixels to tissue dielectric properties and densities. To design a loop for operating at high power levels, energy coupling and impedance matching were optimized using capacitively coupled feed lines embedded in a Teflon rod. Sprague Dawley rats were exposed with the 3 × 1 cm loop antennas, tuned to 837 or 1957 MHz for thermographically determined SAR distributions. Point SARs in brains of restrained rats were also determined thermometrically using fiberoptic probes. Calculated and measured SAR patterns and results from the various exposure configurations are in general agreement. The FDTD computed average brain SAR and ratio of head to whole body absorption were 23.8 W/kg/W and 62% at 837 MHz, and 22.6 W/kg/W and 89% at 1957 MHz. The average brain to whole body SAR ratio was 20 to 1 for both frequencies. At 837 MHz, the maximum measured SAR in the restrained rat brains was 51 W/kg/W in the cerebellum and 40 W/kg/W at the top of the cerebrum. An exposure system operating at 837 MHz is ready for in vivo biological effect studies of radio frequency fields from portable cellular telephones. Two‐tenths of a watt input power to the loop antenna will produce 10 W/kg maximum SAR, and an estimated 4.8 W/kg average brain SAR in a 300 g medium size rat. Bioelectromagnetics 20:75–92, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号