The aim of this study was to evaluate the use of dose difference maps with a convolutional neural network (CNN) to detect multi-leaf collimator (MLC) positional errors in patient-specific quality assurance for volumetric modulated radiation therapy (VMAT). A cylindrical three-dimensional detector (Delta4, ScandiDos, Uppsala, Sweden) was used to measure 161 beams from 104 clinical prostate VMAT plans. For the simulation used error-free plans plus plans with two types of MLC error were introduced: systematic error and random error. A total of 483 dose distributions in a virtual cylindrical phantom were calculated with a treatment planning system. Dose difference maps were created from two planar dose distributions from the measured and calculated dose distributions, and these were used as the input for the CNN, with 375 datasets assigned for training and 108 datasets assigned for testing. The CNN model had three convolution layers and was trained with five-fold cross-validation. The CNN model classified the error types of the plans as “error-free,” “systematic error,” or “random error,” with an overall accuracy of 0.944. The sensitivity values for the “error-free,” “systematic error,” and “random error” classifications were 0.889, 1.000, and 0.944, respectively, and the specificity values were 0.986, 0.986, and 0.944, respectively. This approach was superior to those based on gamma analysis. Using dose difference maps with a CNN model may provide an effective solution for detecting MLC errors for patient-specific VMAT quality assurance.  相似文献   

2.
IntroductionPrevious literature has shown general trade-offs between plan complexity and resulting quality assurance (QA) outcomes. However, existing solutions for controlling this trade-off do not guarantee corresponding improvements in deliverability. Therefore, this work explored the feasibility of an optimization framework for directly maximizing predicted QA outcomes of plans without compromising the dosimetric quality of plans designed with an established knowledge-based planning (KBP) technique.Materials and MethodsA support vector machine (SVM) was developed – using a database of 500 previous VMAT plans – to predict gamma passing rates (GPRs; 3%/3mm percent dose-difference/distance-to-agreement with local normalization) based on selected complexity features. A heuristic, QA-based optimization (QAO) framework was devised by utilizing the SVM model to iteratively modify mechanical treatment features most commonly associated with suboptimal GPRs. Specifically, leaf gaps (LGs) <50 mm were widened by random amounts, which impacts all aperture-based complexity features. 13 prostate KBP-guided VMAT plans were optimized via QAO using user-specified maximum LG displacements before corresponding changes in predicted GPRs and dose were assessed.ResultsPredicted GPRs increased by an average of 1.14 ± 1.25% (p = 0.006) with QAO using a 3 mm maximum random LG displacement. There were small differences in dose, resulting in similarly small changes in tumor control probability (maximum increase = 0.05%) and normal tissue complication probabilities in the bladder, rectum, and femoral heads (maximum decrease = 0.2% in the rectum).ConclusionThis study explored the feasibility of QAO and warrants future investigations of further incorporating QA endpoints into plan optimization.  相似文献   

3.
PurposeWhen using volumetric modulated arc therapy (VMAT) for head and neck cancer, setup errors regarding the shoulders can create loss of target coverage or increased organ-at-risk doses. This study created variations of realistic shoulder deformations to understand the associated VMAT dosimetric effects and investigated water-equivalent thickness (WET) differences using in-house software.MethodsTen patients with head and neck cancer with lower neck involvement were retrospectively and randomly enrolled. Their retrospective analysis comprised treatment planning using RayStation 5.0 (RaySearch Laboratories, Stockholm, Sweden), shoulder deformation of 5–15 mm in three-dimensional axes using the ImSimQA package (Oncology Systems Limited, Shrewsbury, Shropshire, UK), and evaluation of the clinical impact of the dose distribution after recalculating the dose distribution using computed tomography images of deformed shoulders and deforming the dose distribution. Additionally, our in-house software program was used to measure WET differences for shoulder deformation.ResultsWET differences were greater in the superoinferior (SI) direction than in the other directions (the WET difference was >20 mm for 15-mm SI deformation). D99%, D98%, and D95% for all clinical target volumes were within 3%. Local dose differences of more than ±10% were found for normal tissues at the level of the shoulder for 15-mm movement in the SI direction.ConclusionsShoulder deformation of >6 mm could cause large dose variations delivered to the targeted tissue at the level of the shoulder. Thus, to ensure delivery of appropriate treatment coverage to the targeted tissue, shoulder deformation should be taken into consideration during the planning stage.  相似文献   

4.
PurposeA log file-based method cannot detect dosimetric changes due to linac component miscalibration because log files are insensitive to miscalibration. Herein, clinical impacts of dosimetric changes on a log file-based method were determined.Methods and materialsFive head-and-neck and five prostate plans were applied. Miscalibration-simulated log files were generated by inducing a linac component miscalibration into the log file. Miscalibration magnitudes for leaf, gantry, and collimator at the general tolerance level were ±0.5 mm, ±1°, and ±1°, respectively, and at a tighter tolerance level achievable on current linac were ±0.3 mm, ±0.5°, and ±0.5°, respectively. Re-calculations were performed on patient anatomy using log file data.ResultsChanges in tumor control probability/normal tissue complication probability from treatment planning system dose to re-calculated dose at the general tolerance level was 1.8% on planning target volume (PTV) and 2.4% on organs at risk (OARs) in both plans. These changes at the tighter tolerance level were improved to 1.0% on PTV and to 1.5% on OARs, with a statistically significant difference.ConclusionsWe determined the clinical impacts of dosimetric changes on a log file-based method using a general tolerance level and a tighter tolerance level for linac miscalibration and found that a tighter tolerance level significantly improved the accuracy of the log file-based method.  相似文献   

5.
6.
7.
PurposeTo quantify relative merit of MU deprived plans against freely optimized plans in terms of plan quality and report changes induced by progressive resolution optimizer algorithm (PRO3) to the dynamic parameters of RapidArc.Materials and methodsTen cases of carcinoma hypopharynx were retrospectively planned in three phases without using MU tool. Replicas of these baseline plans were reoptimized using “Intermediate dose” feature and “MU tool” to reduce MUs by 20%, 35%, and 50%. Overall quality indices for target and OAR, integral dose, dose-volume spread were assessed. All plans were appraised for changes induced in RapidArc dynamic parameters and pre-treatment quality assurance (QA).ResultsWith increasing MU reduction strength (MURS), MU/Gy values reduced, for all phases with an overall range of 8.6–34.7%; mean dose rate decreased among plans of each phase, phase3 plans recorded greater reductions. MURS20% showed good trade-off between MUs and plan quality. Dose-volume spread below 5 Gy was higher for baseline plans while lower between 20 and 35 Gy. Integral dose was lower for MURS0%, not exceeding 1.0%, compared against restrained plans. Mean leaf aperture and control point areas increased systematically, correlated negatively with increasing MURS. Absolute delta dose rate variations were least for MURS0%. MU deprived plans exhibited GAI (>93%), better than MURS0% plans.ConclusionBaseline plans are superior to MU restrained plans. However, MURS20% offers equivalent and acceptable plan quality with mileage of MUs, improved GAI for complex cases. MU tool may be adopted to tailor treatment plans using PRO3.  相似文献   

8.

Background

IMRT provides highly conformal dose distributions creating non uniform spatial intensity using different segments in the beam.

Material & Methods and Results

Different retrospective studies have shown a high capability of IMRT to treat tumours close to the base of skull. Prospective studies have shown a decrease in xerostomia compared with conventional 3D conformal treatment (3DCRT). Modulation of intensity is performed by the movement of the multileaf collimator (MLC) that can deliver the radiation in different ways, such as static field segments, dynamic field segments and rotational delivery (arc therapy and tomotherapy). There are slight differences among the different techniques in terms of homogeneity, dose conformity and treatment delivery time.

Conclusions

The best method to deliver IMRT will depend on multiple factors such as deliverability, practicality, user training and plan quality.  相似文献   

9.
BackgroundWith full access to both helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT), we compared locally advanced non-small cell lung cancer (LA-NSCLC) treatment plans and verified the plans using patient-specific pretreatment quality assurance (PSQA).Materials and methodsFor each of the seventeen patients included in the study, two treatment plans (i.e. HT and VMAT) were created. Optimized plans were evaluated following the ICRU 83 criteria. Planned quality indexes and dosimetric parameters were compared. Lastly, all plans were subjected to PSQA assessment by determining the gamma passing rate (GPR).ResultsAll dosimetry results obtained from the planning target volume passed the ICRU 83 criteria. With regard to similar homogeneity indices, VMAT produced better conformity number values than HT (0.78 vs. 0.64), but differences in the values were insignificant. Furthermore, VMAT was associated with a significantly shorter mean treatment time (1.91 minutes vs. 6.66 minutes). For PSQA assessment, both techniques resulted in adequate GPR values (> 90% at the 3%/3 mm criteria).ConclusionBoth HT and VMAT techniques led to the generation of clinically satisfactory and reliable radiotherapy plans. However, the VMAT plan was associated with a non-significantly better degree of conformity and a significantly shorter treatment time. Thus, VMAT was determined to be a better choice for LA-NSCLC.  相似文献   

10.
BackgroundWe investigated the change of dose distributions in volumetric modulated arc therapy (VMAT) under baseline drift (BD) during breath holding.Materials and methodsTen VMAT plans recalculated to a static field at a gantry angle of 0° were prepared for measurement with a 2D array device and five original VMAT plans were prepared for measurement with gafchromic films. These measurement approaches were driven by a waveform reproducing breath holding with BD. We considered breath holding times of 15 and 10 s, and BD at four speeds; specifically, BD0 (0 mm/s), BD0.2 (0.2 mm/s), BD0.3 (0.3 mm/s), and BD0.4 (0.4 mm/s). The BD was periodically reproduced from the isocenter along the craniocaudal direction and the shift during breath holding (ShiftBH) ranged 0–6 mm.The dose distribution of BD0.2, BD0.3 and BD0.4 were compared to that of BD0 using gamma analysis with the criterion of 2%/2 mm.ResultsThe mean pass rates of each ShiftBH were 99.8% and 98.9% at 0 mm, 96.8% and 99.4% at 2 mm, 94.9% and 98.6% at 3 mm, 91.5% and 98.4% at 4 mm, 70.8% and 94.1% at 4.5 mm, and 55.0% and 83.6% at 6 mm for the array and film measurements, respectively.ConclusionWe found significant differences in ShiftBH above 4 mm (ρ < 0.05). Hence, it is recommended that breath holding time should be shortened for patients to preserve the reproducibility of dose distributions.  相似文献   

11.

Aim

The RapidArc commissioning and Acceptance Testing program will test and ensure accuracy in DMLC position, precise dose-rate control during gantry rotation and accurate control of gantry speed.

Background

Recently, we have upgraded our linear accelerator capable of performing IMRT which was functional from 2007 with image guided RapidArc facility. The installation of VMAT in the existing linear accelerator is a tedious process which requires many quality assurance procedures before the proper commissioning of the facility and these procedures are discussed in this study.

Materials and methods

Output of the machine at different dose rates was measured to verify its consistency at different dose rates. Monitor and chamber linearity at different dose rates were checked. DMLC QA comprising of MLC transmission factor measurement and dosimetric leaf gap measurements were performed using 0.13 cm3 and 0.65 cm3 Farmer type ionization chamber, dose 1 dosimeter, and IAEA 30 cm × 30 cm × 30 cm water phantom. Picket fence test, garden fence test, tests to check leaf positioning accuracy due to carriage movement, calibration of the leaves, leaf speed stability effects due to the acceleration and deceleration of leaves, accuracy and calibration of leaves in producing complex fields, effects of interleaf friction, etc. were verified using EDR2 therapy films, Vidar scanner, Omnipro accept software, amorphous silicon based electronic portal imaging device and EPIQA software.1–8

Results

All the DMLC related quality assurance tests were performed and evaluated by film dosimetry, portal dosimetry and EPIQA.7

Conclusion

Results confirmed that the linear accelerator is capable of performing accurate VMAT.  相似文献   

12.
BackgroundPatients with brain metastases (BM) live longer due to improved diagnosis and oncologic treatments. The association of volumetric modulated arc therapy (VMAT) and image-guided radiation therapy (IGRT) with brain radiosurgery (SRS) allows complex dose distributions and faster treatment delivery to multiple lesions.Materials and methodsThis study is a retrospective analysis of SRS for brain metastasis using VMAT. The primary endpoints were local disease-free survival (LDFS) and overall survival (OS). The secondary outcomes were intracranial disease-free survival (IDFS) and meningeal disease-free survival (MDFS).ResultsThe average number of treated lesions was 5.79 (range: 2–20) per treatment in a total of 113 patients. The mean prescribed dose was 18 Gy (range: 12–24 Gy). The median LDFS was 46 months. The LDFS in 6, 12, and 24 months was for 86%, 79%, and 63%, respectively. Moreover, brain progression occurred in 50 patients. The median overall survival was 47 months. The OS in 75%, 69%, and 61% patients was 6, 12, and 24 months, respectively. IDFS was 6 and 24 months in 35% and 14% patients, respectively. The mean MDFS was 62 months; it was 6 and 24 months for 87% and 83% of patients. Acute severe toxicity was relatively rare. During follow-up, the rates of radionecrosis and neurocognitive impairment were low (10%).ConclusionThe use of VMAT–SRS for multiple BM was feasible, effective, and associated with low treatment-related toxicity rates. Thus, treatment with VMAT is a safe technique to plan to achieve local control without toxicity.  相似文献   

13.
PurposeAccelerated partial breast irradiation (APBI) is alternative treatment option for patients with early stage breast cancer. The interplay effect on volumetric modulated arc therapy APBI (VMAT-APBI) has not been clarified. This study aimed to evaluate the feasibility of VMAT-APBI for patients with small breasts and investigate the amplitude of respiratory motion during VMAT-APBI delivery that significantly affects dose distribution.MethodsThe VMAT-APBI plans were generated with 28.5 Gy in five fractions. We performed patient-specific quality assurance using Delta4 phantom under static conditions. We also measured point dose and dose distribution using the ionization chamber and radiochromic film under static and moving conditions of 2, 3 and 5 mm. We compared the measured and calculated point doses and dose distributions by dose difference and gamma passing rates.ResultsA total of 20 plans were generated; the dose distributions were consistent with those of previous reports. For all measurements under static conditions, the measured and calculated point doses and dose distributions showed good agreement. The dose differences for chamber measurement were within 3%, regardless of moving conditions. The mean gamma passing rates with 3%/2 mm criteria in the film measurement under static conditions and with 2 mm, 3 mm, and 5 mm of amplitude were 95.0 ± 2.0%, 93.3 ± 3.3%, 92.1 ± 6.2% and 84.8 ± 7.8%, respectively. The difference between 5 mm amplitude and other conditions was statistically significant.ConclusionsRespiratory management should be considered for the risk of unintended dose distribution if the respiratory amplitude is >5 mm.  相似文献   

14.
AimThe aim of the analysis was to compare doses obtained for temporal lobes in patients being irradiated for meningiomas of the brain using the conformal technique and volumetric modulated arc therapy (VMAT). We try to answer the question whether the application of VMAT would lead to higher doses within temporal lobes.BackgroundIn recent years a significant increase in the detection of meningiomas and effectiveness of treatment has been observed. Hence quality of life should be considered as an important aspect after a treatment course.Materials and methodsTreatment plans of 27 patients were evaluated retrospectively. Radiotherapy procedures were carried out from 2007 until 2016 at the Department of Radiation Oncology in Wroclaw, Poland. For individual patients, alternative treatment plans were generated in relation to the ones originally used, wherein from dynamic techniques, volumetric modulated arc therapy was selected for analysis. Evaluated dosimetric parameters for temporal lobes were: mean dose, V10 Gy, V20 Gy, V45 Gy.ResultsStatistically significant differences were observed for V45 Gy for both temporal lobes (p = 0.023) and for V45 Gy for the right (p = 0.001) and the left temporal lobe (p = 0.016) considered for VMAT. The mean values of the V45 Gy for both temporal lobes, for the right temporal lobe and for the left temporal lobe were lower for VMAT than for 3D, respectively: 7.54% and 7.90%, 6.82% and 9.47%, 5.67% and 7.14%.Analysis of the remaining results found no statistical differences.ConclusionApplication of VMAT in patients treated for meningioma of the brain is not related to higher doses of radiation in the temporal lobe area, compared with the conformal technique.  相似文献   

15.
PurposeTo predict the impact of optimization parameter changes on dosimetric plan quality criteria in multi-criteria optimized volumetric-modulated-arc therapy (VMAT) planning prior to optimization using machine learning (ML).MethodsA data base comprising a total of 21,266 VMAT treatment plans for 44 cranial and 18 spinal patient geometries was generated. The underlying optimization algorithm is governed by three highly composite parameters which model a combination of important aspects of the solution. Patient geometries were parametrized via volume- and shape properties of the voxel objects and overlap-volume histograms (OVH) of the planning-target-volume (PTV) and a relevant organ-at-risk (OAR). The impact of changes in one of the three optimization parameters on the maximally achievable value range of five dosimetric properties of the resulting dose distributions was studied. To predict the extent of this impact based on patient geometry, treatment site, and current parameter settings prior to optimization, three different ML-models were trained and tested. Precision-recall curves, as well as the area-under-curve (AUC) of the resulting receiver-operator-characteristic (ROC) curves were analyzed for model assessment.ResultsSuccessful identification of parameter regions resulting in a high variability of dosimetric plan properties depended on the choice of geometry features, the treatment indication and the plan property under investigation. AUC values between 0.82 and 0.99 could be achieved. The best average-precision (AP) values obtained from the corresponding precision/recall curves ranged from 0.71 to 0.99.ConclusionsMachine learning models trained on a database of pre-optimized treatment plans can help finding relevant optimization parameter ranges prior to optimization.  相似文献   

16.
We evaluated the absorbed dose to critical organs, as well as the image quality, at different partial angles in kV-CBCT (Cone Beam Computed Tomography) scanning of the head and neck region. CBCT images of phantom from a 200° rotation were performed by using three different scanning paths, anterior, posterior, and right lateral with Catphan504 and RANDO phantoms. Critical organ dose was measured using TLD 100H in the RANDO phantom. The image quality of those phantoms was evaluated, using HU uniformity, HU linearity, contrast-to-noise ratio, low contrast visibility and spatial resolution with the Catphan504 dataset; and 5-point grading scales for the RANDO phantom dataset by five radiation oncologists. The image qualities from Catphan504 and RANDO phantom of every scanning path were comparable, with no statistically significant difference (p ≥ 0.05). However, there was a significant difference in the critical organ dose in all paths (p < 0.05), depending on the critical organ location and the scanning direction. Scanning directions show no effects on the image quality. Differences in absorbed dose to critical organs should were evaluated. The posterior scanning path for the CBCT was deemed preferable due because of considerably lower doses to several critical organs of the head and neck region.  相似文献   

17.
PurposeTo evaluate the feasibility of the use of iterative cone-beam computed tomography (CBCT) for dose calculation in the head and neck region.MethodsThis study includes phantom and clinical studies. All acquired CBCT images were reconstructed with Feldkamp–Davis–Kress algorithm-based CBCT (FDK-CBCT) and iterative CBCT (iCBCT) algorithm. The Hounsfield unit (HU) consistency between the head and body phantoms was determined in both reconstruction techniques. Volumetric modulated arc therapy (VMAT) plans were generated for 16 head and neck patients on a planning CT scan, and the doses were recalculated on FDK-CBCT and iCBCT with Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB). As a comparison of the accuracy of dose calculations, the absolute dosimetric difference and 1%/1 mm gamma passing rate analysis were analyzed.ResultsThe difference in the mean HU values between the head and body phantoms was larger for FDK-CBCT (max value: 449.1 HU) than iCBCT (260.0 HU). The median dosimetric difference from the planning CT were <1.0% for both FDK-CBCT and iCBCT but smaller differences were found with iCBCT (planning target volume D50%: 0.38% (0.15–0.59%) for FDK-CBCT, 0.28% (0.13–0.49%) for iCBCT, AAA; 0.14% (0.04–0.19%) for FDK-CBCT, 0.07% (0.02–0.20%) for iCBCT). The mean gamma passing rate was significantly better in iCBCT than FDK-CBCT (AAA: 98.7% for FDK-CBCT, 99.4% for iCBCT; AXB: 96.8% for FDK_CBCT, 97.5% for iCBCT).ConclusionThe iCBCT-based dose calculation in VMAT for head and neck cancer was accurate compared to FDK-CBCT.  相似文献   

18.
PurposeThis study evaluated the dose distribution and homogeneity of four different types of intensity-modulated radiotherapy (IMRT) in comparison with standard wedged tangential-beam three-dimensional conformal radiotherapy (3DCRT) of the left breast in patients who had undergone lumpectomy.Materials and methodsFive radiotherapy treatment plans, including 3DCRT, forward-planned IMRT (for-IMRT), inverse IMRT (inv-IMRT), helical tomotherapy (HT) and volumetric-modulated arc therapy (VMAT), were created for 15 consecutive patients.ResultsAll modalities presented similar target coverage. Target max doses were reduced with for-IMRT compared to 3DCRT, and these doses were further reduced with inv-IMRT and HT. HT resulted in the lowest max doses delivered to the heart, left anterior descending artery (LAD), and ipsilateral lung, but had higher mean, max, and low doses delivered to contralateral breast. HT resulted in increased low doses to a large volume of healthy tissue. Compared to other techniques, all inverse-planned modalities significantly improved conformity number; however, VMAT had worse homogeneity. The for-IMRT plan significantly lowered monitor unit (MU) compared to the inverse-planned techniques.ConclusionAll modalities evaluated provide adequate coverage of the whole breast. For-IMRT improves target homogeneity compared with 3DCRT, but to a lesser degree than the inverse-planned inv-IMRT and HT. HT decreases the ipsilateral OAR volumes receiving higher and mean doses with an increase in the volumes receiving low doses, which is known to lead to an increased rate of radiation-induced secondary malignancies.  相似文献   

19.
AimThis study compared volumetric-modulated arc therapy (VMAT) plans for head and neck cancers with and without an external body contour extended technique (EBCT).BackgroundDose calculation algorisms for VMAT have limitations in the buildup region.Materials and methodsThree VMAT plans were enrolled, with one case having a metal artifact from an artificial tooth. The proper dose was calculated using Eclipse version 11.0. The body contours were extended 2 cm outward from the skin surface in three-dimensional space, and the dose was recalculated with an anisotropic analytical algorithm (AAA) and Acuros XB (AXB). Monitor units (MUs) were set, and the dose distributions in the planning target volume (PTV), clinical target volume, and organ at risk (OAR) and conformity index (CI) with and without an EBCT were compared. The influence of a metal artifact outside of the thermoplastic head mask was also compared.ResultsThe coverage of PTV by the 95% dose line near the patient’s skin was increased drastically by using an EBCT. Plan renormalization had a negligible impact on MUs and doses delivered to OARs. CI of PTV with a 6-MV photon beam was closer to 1 than that with a 10-MV photon beam when both AAA and AXB were used in all cases. Metal artifacts outside the head mask had no effect on dose distribution.ConclusionsAn EBCT is needed to estimate the proper dose at object volumes near the patient’s skin and can improve the accuracy of the calculated dose at target volumes.  相似文献   

20.
AimThe purpose of this study was to investigate the dosimetric characteristics of three stereotactic ablative body radiotherapy (SABR) techniques using the anisotropic analytical algorithm (AAA) and Acuros XB algorithm. The SABR techniques include coplanar volumetric modulated arc therapy (C-VMAT), non-coplanar intensity modulated radiation therapy (NC-IMRT) and non-coplanar three-dimensional conformal radiotherapy (NC-3D CRT).BackgroundSABR is a special type of radiotherapy where a high dose of radiation is delivered over a short time. The treatment outcome and accuracy of the dose delivered to cancer patients highly depend on the dose calculation algorithm and treatment technique.Materials and methodsTwelve lung cancer patients underwent 4D CT scanning, and three different treatment plans were generated: C-VMAT, NC-IMRT, NC-3D CRT. Dose calculation was performed using the AAA and Acuros XB algorithm. The dosimetric indices, such as conformity index (CI), homogeneity index, dose fall-off index, doses received by organs at risk and planning target volume, were used to compare the plans. The accuracy of AAA and Acuros XB (AXB) algorithms for the lung was validated against measured dose on a CIRS thorax phantom.ResultsThe CIs for C-VMAT, NC-IMRT and NC-3D CRT were 1.21, 1.28 and 1.38 for the AAA, respectively, and 1.17, 1.26 and 1.36 for the Acuros XB algorithm, respectively. The overall dose computed by AcurosXB algorithm was close to the measured dose when compared to the AAA algorithm. The overall dose computed by the AcurosXB algorithm was close to the measured dose when compared to the AAA algorithm.ConclusionThis study showed that the treatment planning results obtained using the Acuros XB algorithm was better than those using the AAA algorithm in SABR lung radiotherapy.  相似文献   