1.

Background

Buruli ulcer (BU) caused by Mycobacterium ulcerans (M. ulcerans) has emerged as an important public health problem in several rural communities in sub-Saharan Africa. Early diagnosis and prompt treatment are important in preventing disfiguring complications associated with late stages of the disease progression. Presently there is no simple and rapid test that is appropriate for early diagnosis and use in the low-resource settings where M. ulcerans is most prevalent.

Methodology

We compared conventional and pocket warmer loop mediated isothermal amplification (LAMP) methods (using a heat block and a pocket warmer respectively as heat source for amplification reaction) for the detection of M. ulcerans in clinical specimens. The effect of purified and crude DNA preparations on the detection rate of the LAMP assays were also investigated and compared with that of IS2404 PCR, a reference assay for the detection of M. ulcerans. Thirty clinical specimens from suspected BU cases were examined by LAMP and IS2404 PCR.

Principal Findings

The lower detection limit of both LAMP methods at 60°C was 300 copies of IS2404 and 30 copies of IS2404 for the conventional LAMP at 65°C. When purified DNA extracts were used, both the conventional LAMP and IS2404 PCR concordantly detected 21 positive cases, while the pocket warmer LAMP detected 19 cases. Nine of 30 samples were positive by both the LAMP assays as well as IS2404 PCR when crude extracts of clinical specimens were used.

Conclusion/Significance

The LAMP method can be used as a simple and rapid test for the detection of M. ulcerans in clinical specimens. However, obtaining purified DNA, as well as generating isothermal conditions, remains a major challenge for the use of the LAMP method under field conditions. With further improvement in DNA extraction and amplification conditions, the pwLAMP could be used as a point of care diagnostic test for BU  相似文献   

2.

Background

The loop-mediated isothermal amplification (LAMP) assay, with its advantages of simplicity, rapidity and cost effectiveness, has evolved as one of the most sensitive and specific methods for the detection of a broad range of pathogenic microorganisms including African trypanosomes. While many LAMP-based assays are sufficiently sensitive to detect DNA well below the amount present in a single parasite, the detection limit of the assay is restricted by the number of parasites present in the volume of sample assayed; i.e. 1 per µL or 103 per mL. We hypothesized that clinical sensitivities that mimic analytical limits based on parasite DNA could be approached or even obtained by simply adding detergent to the samples prior to LAMP assay.

Methodology/Principal Findings

For proof of principle we used two different LAMP assays capable of detecting 0.1 fg genomic DNA (0.001 parasite). The assay was tested on dilution series of intact bloodstream form Trypanosoma brucei rhodesiense in human cerebrospinal fluid (CSF) or blood with or without the addition of the detergent Triton X-100 and 60 min incubation at ambient temperature. With human CSF and in the absence of detergent, the LAMP detection limit for live intact parasites using 1 µL of CSF as the source of template was at best 103 parasites/mL. Remarkably, detergent enhanced LAMP assay reaches sensitivity about 100 to 1000-fold lower; i.e. 10 to 1 parasite/mL. Similar detergent-mediated increases in LAMP assay analytical sensitivity were also found using DNA extracted from filter paper cards containing blood pretreated with detergent before card spotting or blood samples spotted on detergent pretreated cards.

Conclusions/Significance

This simple procedure for the enhanced detection of live African trypanosomes in biological fluids by LAMP paves the way for the adaptation of LAMP for the economical and sensitive diagnosis of other protozoan parasites and microorganisms that cause diseases that plague the developing world.  相似文献   

3.

Background

Cystic echinococcosis is highly prevalent in northwest China. A cost-effective, easy to operate diagnostic tool with high sensitivity and specificity would greatly facilitate the monitoring of Echinococcus infections in canine definitive hosts.

Methods

The primers used in the LAMP assay were based on the mitochondrial nad5 gene of E. granulosus sensu stricto (E. granulosus s.s., or E.g.s.s.) and were designed using Primer Explorer V4 software. The developed LAMP assay was compared with a conventional PCR method, copro-ELISA and microscopy, using the faeces of dogs experimentally infected with E.g.s.s., and field-collected faeces of domestic dogs including 190 from Qinghai province highly endemic for E.g.s.s. and 30 controls from an area in Gansu, where a domestic dog de-worming program was in operation.

Results

The positivity rates obtained for the field-collected faecal samples were 12.6%, 1.6% and 2.1% by the LAMP, PCR and copro-ELISA assays, respectively. All samples obtained from the control dogs were negative. Compared with the conventional PCR, the LAMP assay provided 88.8% specificity and 100% sensitivity. The higher sensitivity of the LAMP method was also shown by the fact that it could detect the presence of laboratory challenge dog infections of E. granulsous s.s. four days earlier than the PCR method. Three copro-samples shown positive by the commercial copro-ELISA were all negative by LAMP, PCR and microscopy, which suggests these samples may have originated from another infection rather than E. granulsous s.s., possibly E. shiquicus or E. Canadensis, which is also present in China.

Conclusions

We have developed a potentially useful surveillance tool for determining the prevalence of canine E. granulosus s.s. infections in the field. The LAMP assay may lead to a more cost-effective and practicable way of tracking Echinococcus infections in canids, especially when combined with the copro-ELISA.  相似文献   

4.

Background

Human schistosomiasis, mainly due to Schistosoma mansoni species, is one of the most prevalent parasitic diseases worldwide. To overcome the drawbacks of classical parasitological and serological methods in detecting S. mansoni infections, especially in acute stage of the disease, development of cost-effective, simple and rapid molecular methods is still needed for the diagnosis of schistosomiasis. A promising approach is the loop-mediated isothermal amplification (LAMP) technology. Compared to PCR-based assays, LAMP has the advantages of reaction simplicity, rapidity, specificity, cost-effectiveness and higher amplification efficiency. Additionally, as results can be inspected by the naked eye, the technique has great potential for use in low-income countries.

Methodology/Principal findings

A sequence corresponding to a mitochondrial S. mansoni minisatellite DNA region was selected as a target for designing a LAMP-based method to detect S. mansoni DNA in stool samples. We used a S. mansoni murine model to obtain well defined stool and sera samples from infected mice with S. mansoni cercariae. Samples were taken weekly from week 0 to 8 post-infection and the Kato-Katz and ELISA techniques were used for monitoring the infection. Primer set designed were tested using a commercial reaction mixture for LAMP assay and an in house mixture to compare results. Specificity of LAMP was tested using 16 DNA samples from different parasites, including several Schistosoma species, and no cross-reactions were found. The detection limit of our LAMP assay (SmMIT-LAMP) was 1 fg of S. mansoni DNA. When testing stool samples from infected mice the SmMIT-LAMP detected S. mansoni DNA as soon as 1 week post-infection.

Conclusions/Significance

We have developed, for the first time, a cost-effective, easy to perform, specific and sensitive LAMP assay for early detection of S. mansoni in stool samples. The method is potentially and readily adaptable for field diagnosis and disease surveillance in schistosomiasis-endemic areas.  相似文献   

5.

Background

Carrion'' disease, caused by Bartonella bacilliformis, remains truly neglected due to its focal geographical nature. A wide spectrum of clinical manifestations, including asymptomatic bacteremia, and lack of a sensitive diagnostic test can potentially lead to a spread of the disease into non-endemic regions where competent sand fly vectors may be present. A reliable test capable of detecting B. bacilliformis is urgently needed. Our objective is to develop a loop-mediated isothermal amplification (LAMP) assay targeting the pap31 gene to detect B. bacilliformis.

Methods and Findings

The sensitivity of the LAMP was evaluated in comparison to qPCR using plasmid DNA containing the target gene and genomic DNA in the absence and presence of human or sand fly DNA. The detection limit of LAMP was 1 to 10 copies/µL, depending on the sample metrics. No cross-reaction was observed when testing against a panel of various closely related bacteria. The utility of the LAMP was further compared to qPCR by the examination of 74 Lutzomyia longipalpis sand flies artificially fed on blood spiked with B. bacilliformis and harvested at days (D) 1, 3, 5, 7 and 9 post feeding. Only 86% of sand flies at D1 and 63% of flies at D3 were positive by qPCR. LAMP was able to detect B. bacilliformis in all those flies confirmed positive by qPCR. However, none of the flies after D3 were positive by either LAMP or qPCR. In addition to demonstrating the sensitivity of the LAMP assay, these results suggest that B. bacilliformis cannot propagate in artificially fed L. longipalpis.

Conclusions

The LAMP assay is as sensitive as qPCR for the detection of B. bacilliformis and could be useful to support diagnosis of patients in low-resource settings and also to identify B. bacilliformis in the sand fly vector.  相似文献   

6.
DW Kim  PE Kilgore  EJ Kim  SA Kim  DD Anh  BQ Dong  JS Kim  M Seki 《PloS one》2012,7(8):e42954

Background

Streptococcus pneumoniae is a leading cause of invasive bacterial disease in developed and developing countries. We studied the loop-mediated isothermal amplification (LAMP) technique to assess its suitability for detecting S. pneumoniae nucleic acid in cerebrospinal fluid (CSF).

Methodology/Principal Findings

We established an improved LAMP assay targeting the lytA gene (Streptococcus pneumoniae [Sp] LAMP). The analytical specificity of the primers was validated by using 32 reference strains (10 Streptococcus and seven non-Streptococcus species) plus 25 clinical alpha-hemolytic streptococcal strains, including four S. pneumoniae strains and 21 other strains (3 S. oralis, 17 S. mitis, and one Streptococcus species) harboring virulence factor-encoding genes (lytA or ply). Within 30 minutes, the assay could detect as few as 10 copies of both purified DNA and spiked CSF specimens with greater sensitivity than conventional polymerase chain reaction (PCR). The linear determination range for this assay is 10 to 1,000,000 microorganisms per reaction mixture using real-time turbidimetry. We evaluated the clinical sensitivity and specificity of the Sp LAMP assay using 106 randomly selected CSF specimens from children with suspected meningitis in Korea, China and Vietnam. For comparison, CSF specimens were also tested against conventional PCR and culture tests. The detection rate of the LAMP method was substantially higher than the rates of PCR and culture tests. In this small sample, relative to the LAMP assay, the clinical sensitivity of PCR and culture tests was 54.5% and 33.3%, respectively, while clinical specificity of the two tests was 100%.

Conclusions/Significance

Compared to PCR, Sp LAMP detected S. pneumoniae with higher analytical and clinical sensitivity. This specific and sensitive LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.  相似文献   

7.

Background

Lymphatic filariasis is a neglected tropical disease leading to profound disfiguring causing socio economic burden in the tropics. Current diagnosis strategies available during field surveys and epidemics are based on traditional microscopic detections and a few antigen/antibody assays. We have compared different sampling methodologies and standardized the highly sensitive and reliable rWbSXP-1 antigen detection assay to our new sampling methodology.

Methodology

Samples collected as serum, whole blood, whole blood on filter paper and whole blood on microscopic slides from patients belonging to various clinical groups of filariasis [endemic normal(EN), chronic pathology(CP), microfilaraemic(MF) and non-endemic normal(NEN)] were collected and standardized the rWbSXP-1 antigen detection assay using monoclonal antibody raised against rWbSXP-1 protein. The whole blood collected on microscopic slide based sampling method was employed in the field and the presence of circulating filarial antigen (CFA) was assessed using the rWbSXP-1 assay.

Principal Findings

The sampling methods were compared and no significant difference was observed for the detection of CFA (MF, P = 0.304, EN, P = 0.675, CP, P = 0.5698, NEN, P = 0.4494). Further the optimized sampling method was utilized to collect the 1106 samples from Polur, Tiruvannamalai. The rWbSXP-1 assay gave 98 antigen positive results whereas the microscopic method gave only 17.

Conclusions

Four sampling methodologies were analyzed and the new sampling methodology of whole blood collected on microscopic slide was found to be convenient for the detection of CFA using rWbSXP-1 antigen detection assay. The 1106 samples from Polur were collected using the new method. The rWbSXP-1 antigen assay perceived a 7.32% increased result which was read as false negatives on the conventional microscopic staining method. This new sampling methodology coupled with the rWbSXP-1 antigen assay can be used in epidemiological surveys for lymphatic filariasis and the same sampling methodology can be expanded to other antigen based high affinity assays.  相似文献   

8.

Background

Current available methods for diagnosis of schistosomiasis mansoni lack sufficient sensitivity, which results in underreporting of infectious in areas of low endemicity.

Methodology/Principal Findings

We developed three novel diagnostic methodologies for the direct detection of schistosome infection in serum samples. These three new methods were evaluated with positive patients from a low endemicity area in southeast Brazil. The basis of the assay was the production of monoclonal antibodies against the protein backbone of heavily glycosylated Circulating Cathodic Antigen (CCA). The antibodies were also selected for having no specificity to repeating poly-Lewis x units. Assays based on the detection CCA-protein should not encounter a limitation in sensitivity due to a biological background of this particular epitope. Three diagnostic methodologies were developed and validated, (i) Immunomagnetic Separation based on improved incubation steps of non-diluted serum, (ii) Direct Enzyme-linked Immunosorbent Assay and (iii) Fluorescent Microscopy Analysis as a qualitative assay. The two quantitative assays presented high sensitivity (94% and 92%, respectively) and specificity (100%), equivalent to the analysis of 3 stool samples and 16 slides by Kato-Katz, showing promising results on the determination of cure.

Conclusions/Significance

The Immunomagnetic Separation technique showed excellent correlation with parasite burden by Cohen coefficient. The qualitative method detected 47 positive individuals out of 50 with the analysis of 3 slides. This easy-to-do method was capable of discriminating positive from negative cases, even for patients with low parasite burden.  相似文献   

9.

Background

Loop mediated isothermal amplification (LAMP) provides an opportunity for improved, field-friendly detection of malaria infections in endemic areas. However data on the diagnostic accuracy of LAMP for active case detection, particularly low-density parasitaemias, are lacking. We therefore evaluated the performance of a new LAMP kit compared with PCR using DNA from filter paper blood spots.

Methods and Findings

Samples from 865 fever patients and 465 asymptomatic individuals collected in Zanzibar were analysed for Pan (all species) and Pf (P. falciparum) DNA with the Loopamp MALARIA Pan/Pf kit. Samples were amplified at 65°C for 40 minutes in a real-time turbidimeter and results were compared with nested PCR. Samples with discordant results between LAMP and nested PCR were analysed with real-time PCR. The real-time PCR corrected nested PCR result was defined as gold standard. Among the 117 (13.5%) PCR detected P. falciparum infections from fever patients (mean parasite density 7491/µL, range 6–782,400) 115, 115 and 111 were positive by Pan-LAMP, Pf-LAMP and nested PCR, respectively. The sensitivities were 98.3% (95%CI 94–99.8) for both Pan and Pf-LAMP. Among the 54 (11.6%) PCR positive samples from asymptomatic individuals (mean parasite density 10/µL, range 0–4972) Pf-LAMP had a sensitivity of 92.7% (95%CI 80.1–98.5) for detection of the 41 P. falciparum infections. Pan-LAMP had sensitivities of 97% (95%CI 84.2–99.9) and 76.9% (95%CI 46.2–95) for detection of P. falciparum and P. malariae, respectively. The specificities for both Pan and Pf-LAMP were 100% (95%CI 99.1–100) in both study groups.

Conclusion

Both components of the Loopamp MALARIA Pan/Pf detection kit revealed high diagnostic accuracy for parasite detection among fever patients and importantly also among asymptomatic individuals of low parasite densities from minute blood volumes preserved on filter paper. These data support LAMPs potential role for improved detection of low-density malaria infections in pre-elimination settings.  相似文献   

10.

Background

Molecular methods have great potential for sensitive parasite detection in the diagnosis of human African trypanosomiasis (HAT), but the requirements in terms of laboratory infrastructure limit their use to reference centres. A recently developed assay detects the Trypanozoon repetitive insertion mobile element (RIME) DNA under isothermal amplification conditions and has been transformed into a ready-to-use kit format, the Loopamp Trypanosoma brucei. In this study, we have evaluated the diagnostic performance of the Loopamp Trypanosoma brucei assay (hereafter called LAMP) in confirmed T.b. gambiense HAT patients, HAT suspects and healthy endemic controls from the Democratic Republic of the Congo (DRC).

Methodology/Principal findings

142 T.b. gambiense HAT patients, 111 healthy endemic controls and 97 HAT suspects with unconfirmed status were included in this retrospective evaluation. Reference standard tests were parasite detection in blood, lymph or cerebrospinal fluid. Archived DNA from blood of all study participants was analysed in duplicate with LAMP. Sensitivity of LAMP in parasitologically confirmed cases was 87.3% (95% CI 80.9–91.8%) in the first run and 93.0% (95% CI 87.5–96.1%) in the second run. Specificity in healthy controls was 92.8% (95% CI 86.4–96.3%) in the first run and 96.4% (95% CI 91.1–98.6%) in the second run. Reproducibility was excellent with a kappa value of 0.81.

Conclusions/Significance

In this laboratory-based study, the Loopamp Trypanosoma brucei Detection Kit showed good diagnostic accuracy and excellent reproducibility. Further studies are needed to assess the feasibility of its routine use for diagnosis of HAT under field conditions.  相似文献   

11.

Background

There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy.

Methodology/Principal Findings

In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand.A robust reference comparator set comprising following ‘scrub typhus infection criteria’ (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the ‘gold standard’ indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays.Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96–99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%.

Conclusions/Significance

The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.  相似文献   

12.

Background

Acinetobacter baumannii is an increasingly multidrug-resistant (MDR) cause of hospital-acquired infections, often associated with limited therapeutic options. We investigated A. baumannii isolates at a New York hospital to characterize genetic relatedness.

Methods

Thirty A. baumannii isolates from geographically-dispersed nursing units within the hospital were studied. Isolate relatedness was assessed by repetitive sequence polymerase chain reaction (rep-PCR). The presence and characteristics of integrons were assessed by PCR. Metabolomic profiles of a subset of a prevalent strain isolates and sporadic isolates were characterized and compared.

Results

We detected a hospital-wide group of closely related carbapenem resistant MDR A. baumannii isolates. Compared with sporadic isolates, the prevalent strain isolates were more likely to be MDR (p = 0.001). Isolates from the prevalent strain carried a novel Class I integron sequence. Metabolomic profiles of selected prevalent strain isolates and sporadic isolates were similar.

Conclusion

The A. baumannii population at our hospital represents a prevalent strain of related MDR isolates that contain a novel integron cassette. Prevalent strain and sporadic isolates did not segregate by metabolomic profiles. Further study of environmental, host, and bacterial factors associated with the persistence of prevalent endemic A. baumannii strains is needed to develop effective prevention strategies.  相似文献   

13.

Background

Serotype-specific PCR assays targeting Salmonella enterica serotypes Typhi and Paratyphi A, the causal agents of typhoid and paratyphoid fevers, are required to accelerate formal diagnosis and to overcome the lack of typing sera and, in some situations, the need for culture. However, the sensitivity and specificity of such assays must be demonstrated on large collections of strains representative of the targeted serotypes and all other bacterial populations producing similar clinical symptoms.

Methodology

Using a new family of repeated DNA sequences, CRISPR (clustered regularly interspaced short palindromic repeats), as a serotype-specific target, we developed a conventional multiplex PCR assay for the detection and differentiation of serotypes Typhi and Paratyphi A from cultured isolates. We also developed EvaGreen-based real-time singleplex PCR assays with the same two sets of primers.

Principal findings

We achieved 100% sensitivity and specificity for each protocol after validation of the assays on 188 serotype Typhi and 74 serotype Paratyphi A strains from diverse genetic groups, geographic origins and time periods and on 70 strains of bacteria frequently encountered in bloodstream infections, including 29 other Salmonella serotypes and 42 strains from 38 other bacterial species.

Conclusions

The performance and convenience of our serotype-specific PCR assays should facilitate the rapid and accurate identification of these two major serotypes in a large range of clinical and public health laboratories with access to PCR technology. These assays were developed for use with DNA from cultured isolates, but with modifications to the assay, the CRISPR targets could be used in the development of assays for use with clinical and other samples.  相似文献   

14.

Background

Detection of Acinetobacter baumannii has been relying primarily on bacterial culture that often fails to return useful results in time. Although DNA-based assays are more sensitive than bacterial culture in detecting the pathogen, the molecular results are often inconsistent and challenged by doubts on false positives, such as those due to system- and environment-derived contaminations. In addition, these molecular tools require expensive laboratory instruments. Therefore, establishing molecular tools for field use require simpler molecular platforms. The loop-mediated isothermal amplification method is relatively simple and can be improved for better use in a routine clinical bacteriology laboratory. A simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in the same platform has been developed in recent years. This method is referred to as real-time loop-mediated isothermal amplification. In this study, we attempted to utilize this method for rapid detection of A. baumannii.

Methodology and Significant Findings

Species-specific primers were designed to test the utility of this method. Clinical samples of A. baumannii were used to determine the sensitivity and specificity of this system compared to bacterial culture and a polymerase chain reaction method. All positive samples isolated from sputum were confirmed to be the species of Acinetobacter by 16S rRNA gene sequencing. The RealAmp method was found to be simpler and allowed real-time detection of DNA amplification, and could distinguish A. baumannii from Acinetobacter calcoaceticus and Acinetobacter genomic species 3. DNA was extracted by simple boiling method. Compared to bacterial culture, the sensitivity and specificity of RealAmp in detecting A. baumannii was 98.9% and 75.0%, respectively.

Conclusion

The RealAmp assay only requires a single unit, and the assay positivity can be verified by visual inspection. Therefore, this assay has great potential of field use as a molecular tool for detection of A. baumannii.  相似文献   

15.

Background

The LightCycler® Mycobacterium Detection Kit based on real-time PCR technology for the detection of Mycobacterium tuberculosis, Mycobacterium avium and Mycobacterium kansasii was recently developed. This study evaluated its analytical sensitivity, specificity and reproducibility.

Methodology/Principal Findings

Plasmid standards were prepared and used to determine the limit of detection. The assay was also performed against organisms other than mycobacteria, other mycobacterial strains and interfering substances to exclude cross-reactivity and interference. Reference standards were prepared and tested to assess the assay''s reproducibility. All PCR assays were performed using the LightCycler® 2.0 Instrument. The detection limit for M. tuberculosis was 28 copies per microlitre. Neither cross-reactivity nor interference occurred with non-mycobacterial organisms and substances tested. Overall reproducibility for consecutive measurements, run-to-run, lot-to-lot, day-to-day and laboratory-to-laboratory achieved a coefficient of variance of less than two percent.

Significance

The LightCycler® Mycobacterium Detection kit has shown to be a robust and accurate assay with the potential to be used as a rapid TB diagnostic test.  相似文献   

16.

Background

Detection of enzyme activity or transgene expression offers potential insight into developmental biology, disease progression, and potentially personalized medicine. Historically, the lacZ gene encoding the enzyme β-galactosidase has been the most common reporter gene and many chromogenic and fluorogenic substrates are well established, but limited to histology or in vitro assays. We now present a novel approach for in vivo detection of β-galactosidase using optical imaging to detect light emission following administration of the chemiluminescent 1,2-dioxetane substrate Galacto-Light PlusTM.

Methodology and Principal Findings

B-gal activity was visualized in stably transfected human MCF7-lacZ tumors growing in mice. LacZ tumors were identified versus contralateral wild type tumors as controls, based on two- to tenfold greater light emission following direct intra tumoral or intravenous administration of reporter substrate. The 1,2-dioxetane substrate is commercially available as a kit for microplate-based assays for β-gal detection, and we have adapted it for in vivo application. Typically, 100 µl substrate mixture was administered intravenously and light emission was detected from the lacZ tumor immediately with gradual decrease over the next 20 mins. Imaging was also undertaken in transgenic ROSA26 mice following subcutaneous or intravenous injection of substrate mixture.

Conclusion and Significance

Light emission was detectable using standard instrumentation designed for more traditional bioluminescent imaging. Use of 1,2-dioxetane substrates to detect enzyme activity offers a new paradigm for non-invasive biochemistry in vivo.  相似文献   

17.

Background

The current spread of pandemic influenza A(H1N1)v virus necessitates an intensified surveillance of influenza virus infections worldwide. So far, in many laboratories routine diagnostics were limited to generic influenza virus detection only. To provide interested laboratories with real-time PCR assays for type and subtype identification, we present a bundle of PCR assays with which any human influenza A and B virus can be easily identified, including assays for the detection of the pandemic A(H1N1)v virus.

Principal Findings

The assays show optimal performance characteristics in their validation on plasmids containing the respective assay target sequences. All assays have furthermore been applied to several thousand clinical samples since 2007 (assays for seasonal influenza) and April 2009 (pandemic influenza assays), respectively, and showed excellent results also on clinical material.

Conclusions

We consider the presented assays to be well suited for the detection and subtyping of circulating influenza viruses.  相似文献   

18.

Background

Patients with end-stage renal disease (ESRD) and latently infected with Mycobacterium tuberculosis (LTBI) are at higher risk to develop tuberculosis (TB) than healthy subjects. Interferon-gamma release assays (IGRAs) were reported to be more sensitive than tuberculin skin tests for the detection of infected individuals in dialysis patients.

Methods

On 143 dialysis patients prospectively enrolled, we compared the results from the QuantiFERON®-TB Gold assay (QFT), to those of an IGRA in response to in vitro stimulation of circulating mononuclear cells with the mycobacterial latency antigen Heparin-Binding Haemagglutinin purified from Mycobacterium bovis BCG (native HBHA, nHBHA).

Results

Seven patients had a past history of active TB and 1 had an undetermined result with both IGRAs. Among the other 135 patients, 94 had concordant results with the QFT and nHBHA-IGRA, 40.0% being negative and therefore not latently infected, and 29.6% being positive and thus LTBI. Discrepant results between these tests were found for 36 patients positive only with the nHBHA-IGRA and 5 only with the QFT.

Conclusions

The nHBHA-IGRA is more sensitive than the QFT for the detection of LTBI dialysis patients, and follow-up of the patients will allow us to define the clinical significance of discrepant results between the nHBHA-IGRA and the QFT.  相似文献   

19.
20.

Background

Selection of drug-resistant strains may lead to failure of HBV antiviral therapy. There is little information whether there is detection difference in drug resistant mutations between different viral load assays of HBV.

Objectives

This study is aimed to investigate whether there is drug-resistant strains related detection difference between Abbott RealTime HBV (RealTime) and CobasAmpliPrep/CobasTaqMan HBV assays 2.0 (TaqMan).

Study Design

One hundred and thirty-four CHB patients who received HBV anti-viral therapy were enrolled. HBV virological markers were tested 3 months apart regularly. Serum HBV DNA levels were determined using the TaqMan and RealTime. YMDD (rt180M and rt204V) mutation was checked in patients who experienced virologic breakthrough (VBT).

Results

The correlation of HBV DNA observed between the RealTime and TaqMan was good for all 571 samples (R2 = 0.797; P<0.001). However, the correlation in the 434 samples with HBV DNA level <3 log10 IU/ml was not as good as in all samples (R2 = 0.457). Overall, 21.5% of samples had a detection difference of ≥1 log10 IU/ml with 91.9% of these having HBV DNA level <3 log10 IU/ml. Twenty-four patients experiencedVBT. Three of these patients had acquired the YMDD mutation and exhibited discordant viral load results between the two methods tested. In each case, persistent HBV DNA was detected by RealTime and undetectable with TaqMan. Of the patients who experienced a VBT and had acquired YMDD mutation, 4.7% had undetectable HBV DNA by TaqMan while all were detectable with RealTime.

Conclusions

RealTime assay is more sensitive and is little impacted by the development of drug resistant mutation.  相似文献   