首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Dmitrenko  G. N.  Konovalova  V. V.  Shum  O. A. 《Microbiology》2003,72(3):327-330
Non-nitrate-reducing collection bacteria from the genus Pseudomonas were found to be able to use hexavalent chromium as a terminal electron acceptor. The reduction of Cr(VI) was accompanied by an increase in the cell biomass. At Cr(VI) concentrations in the medium lower than 15 mg/l, the non-nitrate-reducing pseudomonads reduced Cr(VI) less efficiently than did denitrifying pseudomonads. In contrast, at Cr(VI) concentrations higher than 30 mg/l, Cr(VI) was reduced more efficiently by the non-nitrate-reducing pseudomonads than by the denitrifying pseudomonads.  相似文献   

2.
Microbial reduction is a promising strategy for chromium remediation, but the effects of competing electron acceptors are still poorly understood. We investigated chromate (Cr(VI)) reduction in batch cultures of Shewanella oneidensis MR-1 under aerobic and denitrifying conditions and in the absence of an additional electron acceptor. Growth and Cr(VI) removal patterns suggested a cometabolic reduction; in the absence of nitrate or oxygen, MR-1 reduced Cr(VI), but without any increase in viable cell counts and rates gradually decreased when cells were respiked. Only a small fraction (1.6%) of the electrons from lactate were transferred to Cr(VI). The 48-h transformation capacity (Tc) was 0.78 mg (15 micromoles) Cr(VI) reduced. [mg protein](-1) for high levels of Cr(VI) added as a single spike. For low levels of Cr(VI) added sequentially, Tc increased to 3.33 mg (64 micromoles) Cr(VI) reduced. [mg protein](-1), indicating that it is limited by toxicity at higher concentrations. During denitrification and aerobic growth, MR-1 reduced Cr(VI), with much faster rates under denitrifying conditions. Cr(VI) had no effect on nitrate reduction at 6 microM, was strongly inhibitory at 45 microM, and stopped nitrate reduction above 200 microM. Cr(VI) had no effect on aerobic growth at 60 microM, but severely inhibited growth above 150 microM. A factor that likely plays a role in Cr(VI) toxicity is intracellular reduced chromium. Transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) of denitrifying cells exposed to Cr(VI) showed reduced chromium precipitates both extracellularly on the cell surface and, for the first time, as electron-dense round globules inside cells.  相似文献   

3.
The chromate-reducing ability of Pseudomonas aeruginosa A2Chr was compared in batch culture, with cells entrapped in a dialysis sac, and with cells immobilized in an agarose-alginate film in conjunction with a rotating biological contactor. In all three systems, the maximum Cr(VI) reduction occurred at 10 mg Cr(VI)/l. Whereas at 50 mg Cr(VI)/l concentration, only 16% of the total Cr(VI) was reduced, five spikings with 10 mg chromate/l at 2-h intervals led to 96% reduction of the total input of 50 mg Cr(VI)/l. Thus maximum Cr(VI) reduction was achieved by avoiding Cr(VI) toxicity to the cells by respiking with lower Cr(VI) concentrations. At 10 mg Cr(VI)/l, the pattern of chromate reduction in dialysis-entrapped cells was almost similar to that of batch culture and 86% of the bacterially reduced chromium was retained inside the dialysis sac. In electroplating effluent containing 100 mg Cr(VI)/l, however, the amount of Cr(VI) reduced by the cells immobilized in agarose-alginate biofilm was twice and thrice the amount reduced by batch culture and cells entrapped in a dialysis sac, respectively.  相似文献   

4.
Chen Y  Gu G 《Bioresource technology》2005,96(15):1713-1721
The long-term continuous chromium(VI) removal from synthetic wastewater affected by influent hexavalent chromium (Cr(VI)) and glucose concentrations were studied with an anaerobic-aerobic activated sludge process. It was observed that before activated sludge was acclimated, the chromium in the effluent increased immediately as the influent chromium increased. However, both Cr(VI) and total chromium (TCr) in the effluent significantly decreased after acclimation. In the acclimated activated sludge, the chromium removal efficiency was 100% Cr(VI) and 98.56% TCr at influent Cr(VI) levels of 20 mg/day, 100% Cr(VI) and 98.92% TCr at influent Cr(VI) levels of 40 mg/day, and 98.64% Cr(VI) and 97.16% TCr at influent Cr(VI) levels of 60 mg/day. The corresponding effluent Cr(VI) and TCr concentrations were 0 and 0.012 mg/l, 0 and 0.018 mg/l, and 0.034 mg/l and 0.071 mg/l, respectively. When the influent glucose increased from 1125 to 1500 mg/l at influent Cr(VI) dosage of 60 mg/day, the Cr(VI) and TCr removal efficiency with the acclimated activated sludge improved from 98.64% and 97.16% to 100% and 98.48%, respectively, and the chromium concentration in the effluent decreased from 0.034 mg/l of Cr(VI) and 0.071 mg/l of TCr to 0 (Cr(VI)) and 0.038 mg/l (TCr). The effluent COD and turbidity was around 40 mg/l and 0, respectively, after the activated sludge was acclimated. Further studies showed that after the activated sludge was acclimated, its specific dehydrogenases activity (SDA) and protein contents increased. The SDA and protein increased respectively 15% and 10% when influent Cr(VI) increased from 20 to 60 mg/day.  相似文献   

5.
Enrichment mixed cultures tolerating relatively high concentrations of chromium and salt ions were isolated and their bioaccumulation properties improved by adaptation. Mixed cultures were enriched in Nutrient Broth media containing 25-300 mg l(-1) Cr(VI) and 0%, 2%, 4%, 6% (w/v) NaCl. Bioaccumulation of Cr(VI) was studied in a batch system as a function of initial pH (7, 8 and 9), Cr(VI) and NaCl concentrations. Increasing NaCl and Cr(VI) concentrations led to significant decreases in percentage uptake and dried weight of mixed cultures but increased maximum specific chromium uptake. The maximum specific chromium uptake value at pH 8 was 58.9 mg g(-1) for 316.1 mg l(-1) Cr(VI) in the absence of NaCl, while at pH 9 it was 130.1 mg g(-1) in media including 194.5 mg l(-1) Cr(VI) and 2% NaCl concentrations. At 4% NaCl, the maximum Cr(VI) uptake of 127.0 mg g(-1) for 221.1 mg l(-1) Cr(VI) occurred at pH 9, while at 6% NaCl the maximum Cr(VI) uptake of 114.9 mg g(-1) for 278.1 mg l(-1) Cr(VI) was found at pH 7.  相似文献   

6.
Chromium(VI) was reduced by Enterobacter cloacae strain HO1 grown with sucrose as a carbon source and nitrate as the initial terminal electron acceptor. Under excess substrate conditions, the Cr(VI) concentration, initially at 5 and 10 mg/l, was reduced to less than 100 mg/l.  相似文献   

7.
Natural habitats are often characterized by the coexistence of Zn and Cr. This study assessed the potential of two Gram-positive, Cr(VI)-reducing, aerobic bacterial strains belonging to Arthrobacter genera, which were isolated from basalt samples taken from the most polluted region of the Republic of Georgia, to remediate Cr(VI) in environments in the presence of Zn(II). Our batch experiments revealed that the addition of Zn(II) to the tested bacterial cells significantly enhanced the accumulation of Cr. According to electron spin resonance (ESR) measurements, the presence of Zn(II) ions did not change the nature of Cr(V) and Cr(III) complexes generated during the microbial reduction of Cr(VI). The efficiency of Cr(VI) reduction also remained unchanged after the addition of 50 mg/l of Zn(II) to the bacterial cells. However, at high concentrations of Zn(II) (higher than 200 mg/l), the transformation of Cr(VI) to Cr(V) and Cr(III) complexes decreases significantly. In addition, it was shown that the accumulation pattern of Zn in the tested bacterial species in the presence of 100 mg/l of Cr(VI) fits the Langmuir–Freundlich model well. The two tested bacterial strains exhibited different characteristics of Zn accumulation.  相似文献   

8.
Hexavalent chromium reduction and accumulation by Acinetobacter AB1 isolated from Fez tanneries effluents were tested. The effects of some environmental factors such as pH, temperature, and exposure time on Cr(VI) reduction and resistance were investigated. We found that this strain was able to resist to concentrations as high as 400 mg/l of Cr(VI). Moreover, pH 10 and the temperature 30°C constitute favourable conditions to the growth and reduction of Acinetobacter AB1. Complete reduction of Cr(VI) was observed at low initial Cr(VI) concentrations of 50 mg/l after 72 h of incubation. Furthermore, Transmission electron microscope (TEM) analysis showed morphological changes in AB1 strain due 48H exposure to 100 mg/l chromate concentration and revealed circular electron dense (dark black point) inclusion within the cell cytoplasm suggesting chromium deposition within the cells.  相似文献   

9.
This study reported the hexavalent chromium removal by untreated Mucor racemosus biomass and the possible mechanism of Cr (VI) removal to the biomass. The optimum pH, biomass dose, initial Cr (VI) concentration and contact time were investigated thoroughly to optimize the removal condition. The metal removal by the biomass was strongly affected by pH and the optimum pH ranged from 0.5 to 1.0. The residual total Cr was determined. It was found that dichromate reduction occurred at a low very low pH value. At biomass dose 6 g/l, almost all the Cr (VI) ions were removed in the optimum condition. Higher removal percentage was observed at lower initial concentrations of Cr (VI) ions, while the removal capacity of the biomass linearly depended on the initial Cr (VI) concentration. More than half of Cr (VI) ions were diminished within 1 h of contact and removal process reached a relative equilibrium in approximately 8 h. Almost all of the Cr (VI) ions were removed in 24 h when initial concentrations were below 100 mg/l. The equilibrium data were fitted in to the Langmuir and the Freundlich isotherm models and the correlated coefficients were gained from the models. A Fourier transform infrared spectra was employed to elucidate clearly the possible biosorption mechanism as well.  相似文献   

10.
Cr-B2, a Gram-negative hexavalent chromium [Cr(VI)] reducing bacteria, was isolated from the aerator water of an activated sludge process in the wastewater treatment facility of a dye and pigment based chemical industry. Cr- B2 exhibited a resistance for 1,100 mg/l Cr(VI) and, similarly, resistance against other heavy metal ions such as Ni2+ (800 mg/l), Cu2+ (600 mg/l), Pb2+ (1,100 mg/l), Cd2+ (350 mg/l), Zn2+ (700 mg/l), and Fe3+ (1,000 mg/l), and against selected antibiotics. Cr-B2 was observed to efficiently reduce 200 mg/l Cr(VI) completely in both nutrient and LB media, and could convert Cr(VI) to Cr(III) aerobically. Cr(VI) reduction kinetics followed allosteric enzyme kinetics. The Km values were found to be 43.11 mg/l for nutrient media and 38.05 mg/l for LB media. Vmax values of 13.17 mg/l/h and 12.53 mg/l/h were obtained for nutrient media and LB media, respectively, and the cooperativity coefficients (n) were found to be 8.47 and 3.49, respectively, indicating positive cooperativity in both cases. SEM analysis showed the formation of wrinkles and depressions in the cells when exposed to an 800 mg/l Cr(VI) concentration. The organism was seen to exhibit pleomorphic behavior. Cr-B2 was identified on the basis of morphological, biochemical, and partial 16S rRNA gene sequencing chracterizations and found to be Acinetobacter sp.  相似文献   

11.
In recent years, more and more attentions are put on the remediation of Cr(VI) contamination with chromate resistant bacteria. Leucobacter sp. CRB1 was a novel chromate reducing bacteria isolated from the soil of chromite ore processing residue (COPR) disposal site in Changsha, China. The objectives of this study were to evaluate the Cr(VI) tolerance of Leucobacter sp. CRB1 as well as its tolerant mechanism, and Cr(VI) reduction ability. The results showed that Leucobacter sp. CRB1 was able to tolerate 4,000 mg/l of hexavalent chromium with 34.5% reduction efficiency. At the optimum pH 9.0, the maximum concentration of chromate be reduced completely was 1,818 mg/l in growing cells and 2,100 mg/l in resting cells. Scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDAX) showed that extracellular Cr(VI) reduction of Leucobacter sp. CRB1 contributed to its high tolerance and high reduction ability. With repeating spiking, 2,490 mg/l hexavalent chromium was reduced totally within 17 h. The results suggest Leucobacter sp. CRB1 has potential application for remediation of high concentration of Cr(VI) contamination.  相似文献   

12.
The contamination of soil and wastewaters with Cr(VI) is a major problem. It has been suggested that microbial methods for Cr(VI) reduction are better than chemical methods, as they do not add other ions or toxic chemicals to the environment. In this study an aerobic reduction of Cr(VI) to Cr(III) by employing mixed Pseudomonas cultures isolated from a marshy land has been reported. The role of chromium concentration, temperature, pH and additives on the microbial reduction of Cr(VI) has been investigated. NADH was found to enhance the rate of reduction of Cr(VI). Complete reduction of chromium(VI) has been possible even at chromium(VI) concentrations of 300 ppm. Ions like SO(4)(2-) and poly-phenols inhibited the metabolic activity relating to Cr(VI) reduction. Under optimal conditions 100 mg/L of Cr(VI) was completely reduced within 180 min.  相似文献   

13.
Two chromium-resistant bacteria (IFR-2 and IFR-3) capable of reducing/transforming Cr(VI) to Cr(III) were isolated from tannery effluents. Isolates IFR-2 and IFR-3 were identified as Staphylococcus aureus and Pediococcus pentosaceus respectively by 16S rRNA gene sequence analyses. Both isolates can grow well on 2,000 mg/l Cr(VI) (as K2Cr2O7) in Luria-Bertani (LB) medium. Reduction of Cr(VI) was found to be growth-associated in both isolates and IFR-2 and IFR-3 reduced 20 mg/l Cr(VI) completely in 6 and 24 h respectively. The Cr(VI) reduction due to chromate reductase activity was detected in the culture supernatant and cell lysate but not at all in the cell extract supernatant of both isolates. Whole cells of IFR-2 and IFR-3 converted 24 and 30% of the initial Cr(VI) concentration (1 mg/l) in 45 min respectively at 37°C. NiCl2 stimulated the growth of IFR-2 whereas HgCl2 and CdCl2 significantly inhibited the growth of both isolates. Optimum temperature and pH for growth of and Cr(VI) reduction by both isolates were found to be between 35 and 40°C and pH 7.0 to 8.0. The two bacterial isolates can be good candidates for detoxification of Cr(VI) in industrial effluents.  相似文献   

14.
Chrome mining activity has contributed intensively towards pollution of hexavalent chromium around Sukinda Valley, Orissa, India. In an attempt to study the specific contribution of exopolysaccharides (EPS) extracted from indigenous isolates towards Cr(VI) reduction, three chromium (VI) tolerant strains were isolated from the effluent mining sludge. Based on the tolerance towards Cr(VI) and EPS production capacity, one of them was selected for further work. The taxonomic identity of the selected strain was confirmed to be Enterobacter cloacae (showing 98% similarity in BLAST search to E. cloacae) through 16S rRNA analysis. The EPS production was observed to increase with increasing Cr(VI) concentration in the growth medium, highest being 0.078 at 100?mg/l Cr(VI). The extracted EPS from Enterobacter cloacae SUKCr1D was able to reduce 31.7% of Cr(VI) at 10?mg/l concentration, which was relevant to the prevailing natural concentrations at Sukinda mine effluent sludge. The FT-IR spectral studies confirmed the surface chemical interactions of hexavalent chromium with EPS.  相似文献   

15.
A bacterial isolate (G161) with high Cr(VI)-reducing capacity was isolated from Cr(VI)-contaminated soil and identified as Leucobacter sp. on the basis of 16S rRNA gene sequence analysis. The isolate was a Gram-positive, aerobic rod. The hexavalent chromate-reducing capability of the isolate was investigated under three conditions of oxygen stress. The isolate was found to reduce Cr(VI) under all conditions but performed most effectively during aerobic growth followed by facultative anaerobic incubation. Under these conditions, the isolate tolerated K2Cr2O7 concentrations up to 1,000 mg/l and completely reduced 400 mg/l K2Cr2O7 within 96 h. The strain reduced Cr(VI) over a wide range of pH (6.0–11.0) and temperatures (15–45 °C) with optimum performance at pH?8.0 and 35 °C. The presence of other metals, such as Ca2+, Co2+, Cu2+, Mn2+, Ni2+, and Zn2+, induced no effect or else played a stimulatory role on Cr(VI)-reduction activity of the strain. The strain was tested for Cr(VI) removal in wastewaters and proved capable of completely reducing the contained Cr(VI). This is the novel report of a bacterial growth and Cr(VI)-reduction process under sequential aerobic growth and facultative anaerobic conditions. The study suggested that the isolate possesses a distinct capability for Cr(VI) reduction which could be harnessed for the detoxification of chromate-contaminated wastewaters.  相似文献   

16.
真菌还原Cr(VI)的研究   总被引:7,自引:0,他引:7  
从不同来源的样品中分离筛选出几株抗Cr(VI)的真菌,他们能在含300 ̄500mg/LK2Cr2O7的蔗糖合成培养基中生长,其中BS-1菌株抗K2Cr2O7达900mg/L.BS-1等4株真菌在含200mg/L K2Cr2O7的培养基中生长4 ̄6d后,培养液中的Cr(VI)已全部消失。这些真菌经鉴定为青霉菌BS-1和BS-3,黑曲霉BR-4和黄曲霉BX-1。经紫外可见光扫描及化学分析证实,高毒的C  相似文献   

17.
The anaerobic digestion of cattail by rumen cultures in the presence of Cu(II), Cd(II) or Cr(VI) was investigated in this study. Three cases were respectively observed for the different metal dosages: promoted cattail degradation and methane production at a low heavy metal concentration, e.g., Cu(II) 2.4 mg/l, Cd(II) 1.6 mg/l, Cr(VI) 4.0 mg/l; reduced cattail degradation efficiency and methane production at a middle metal level; a severe inhibition to the cattail degradation at a high heavy metal dosage. The inhibition kinetics of Cu(II) on the digestion of cattail by rumen cultures was also analyzed and a simplified Andrews equation was used to describe such an inhibition. The inhibition constants for Cu(II) on the degradation of cattail, production of volatile fatty acids and formation of methane were estimated as 7.4, 9.5 and 6.4 mg/l, respectively. Comparative experimental results suggest that the order of toxicity degree of the tested metals on the rumen cultures was: Cd(II) > Cu(II) > Cr(VI).  相似文献   

18.
A chromium-reducing strain QH-1, identified as Bacillus sp., was isolated from soil under chromium-containing slag heap in Qinghai high altitude area, China. The strain was found to resist 200 mg/L Cr(VI), and Cr(VI) negatively affects the metabolic activity of the cells, as well as the cell morphology of Bacillus sp. QH-1. The reduction efficiency of Cr(VI) at concentrations of Cr(VI) 25 mg/L, 50 mg/L, 100 mg/L and 200 mg/L were 99.48 %, 65.99 %, 23.22 % and 6.99 %, respectively, decreasing with increasing initial Cr(VI) concentration. This indicates that the toxicity of Cr(VI) increased with concentration. Energy dispersive X-ray analysis revealed that there was insoluble Cr(III) generated during Cr(VI) reduction. In order to apply strain QH-1 to remove Cr(VI) from groundwater, factors of concentration of electron donors (glucose) and temperature were investigated in a synthetic medium. The results demonstrated that glucose could promote the reduction of Cr(VI) by this strain, and the general trend of Cr(VI) reduction increased with temperature within the range of 4 to 37 °C. Cr(VI) was reduced effectively at 25 °C and 37 °C, and all of Cr(VI) was reduced after 96 h at 37 °C, while the reduction was slow at 4 °C and 15 °C, and it almost ceased after about 120 h. These results could be potentially useful for the bioremediation of Cr(VI) in groundwater.  相似文献   

19.
Based on the kinetics of Cr(VI) reduction by Escherichia coli ATCC 33456 and phenol degradation by Pseudomonas putida DMP-1, a mathematical model is developed to describe simultaneous Cr(VI) reduction and phenol degradation in the coculture of the two species. The developed model incorporates the toxicity effects of Cr(VI) and phenol on phenol degradation and Cr(VI) reduction in the coculture. The model illustrates the inhibitory effects of phenol on Cr(VI) reduction and Cr(VI) toxicity toward phenol degradation. The model also reveals the recoveries of the activities of the repressed bacterial cells with continuous Cr(VI) reduction and phenol degradation in the coculture. The model is capable of predicting simultaneous Cr(VI) reduction and phenol degradation within a broad range of Cr(VI) and phenol concentrations and under an appropriate composition of populations. However, the model simulates lower concentrations of phenol than experimental observations once Cr(VI) is reduced to a low level (<7 mg/L). The model simulation for Cr(VI) also deviates from experimental data when P. putida is outnumbered by E. coli by a ratio of 1:5. (c) 1995 John Wiley & Sons, Inc.  相似文献   

20.
In this study, a combination of inductively coupled plasma optical emission spectroscopy and X-ray absorption spectroscopy (XAS) was used to study the uptake and speciation of chromium in Parkinsonia aculeata, commonly known as Mexican Palo Verde. Plants were treated for 14 days in a modified Hoagland solution containing chromium(III) or chromium(VI) at several concentrations. The results showed that plants treated with 70 mg Cr(III) L(-1) and 30 mg Cr(VI) L(-1) had similar Cr concentrations in leaves (~200 mg kg(-1) dry weight, DW). The results also showed that neither Cr(III) nor Cr(VI) affected the uptake of phosphorus and sulfur. However, the concentration of calcium in the stems of plants treated with Cr(VI) at 40 mg L(-1) (about 6000 mg Ca kg(-1) DW) was significantly higher compared to the Ca concentration (about 3000 mg kg(-1) DW) found in the stems of plants treated with 150 mg Cr(III) L(-1). However, no differences were observed in potassium and magnesium concentrations. The iron concentration (about 1000 mg kg(-1) DW) in roots treated with 40 mg Cr(VI) L(-1) was similar to the iron concentration found in the roots of plants treated with 110 mg Cr(III) L(-1). The XAS data showed that Cr(VI) was reduced to Cr(III) in/on the plant roots and transported as Cr(III) to the stems and leaves. The XAS studies also showed that Cr(III) within plants was present as an octahedral complex.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号