首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Numerous models used to investigate the causes of low back pain are based upon the concept of the lever model that considers equilibrium of forces and moments about a single intervertebral joint. Consideration of forces and moments at each intervertebral joint is essential if a more realistic idea of the loading on the spine is to be obtained. This will also allow the role of the curvature of the spine to be investigated. A distributed loading pattern for forces due to body weight for the whole spine has not been investigated before. In this paper, a distributed loading pattern for the whole spine for various postures is investigated and the potential impact on the calculations is discussed.  相似文献   

2.
Research concerning forefoot strike pattern (FFS) versus rearfoot strike pattern (RFS) running has focused on the ground reaction force even though internal joint contact forces are a more direct measure of the loads responsible for injury. The main purpose of this study was to determine the internal loading of the joints for each strike pattern. A secondary purpose was to determine if converted FFS and RFS runners can adequately represent habitual runners with regards to the internal joint loading. Using inverse dynamics to calculate the net joint moments and reaction forces and optimization techniques to estimate muscle forces, we determined the axial compressive loading at the ankle, knee, and hip. Subjects consisted of 15 habitual FFS and 15 habitual RFS competitive runners. Each subject ran at a preferred running velocity with their habitual strike pattern and then converted to the opposite strike pattern. Plantar flexor muscle forces and net ankle joint moments were greater in the FFS running compared to the RFS running during the first half of the stance phase. The average contact forces during this period increased by 41.7% at the ankle and 14.4% at the knee joint during FFS running. Peak ankle joint contact force was 1.5 body weights greater during FFS running (p<0.05). There was no evidence to support a difference between habitual and converted running for joint contact forces. The increased loading at the ankle joint for FFS is an area of concern for individuals considering altering their foot strike pattern.  相似文献   

3.
The exact loads acting on the lumbar spine during standing remain hitherto unknown. It is for this reason that different loads are applied in experimental and numerical studies. The aim of this study was to compare intersegmental rotations, intradiscal pressures and facet joint forces for different loading modes simulating standing in order to ascertain, the results for which loading modes are closest to data measured in vivo.A validated osseoligamentous finite element model of the lumbar spine ranging from L1 to the disc L5–S1, was used. Six load application modes were investigated as to how they could simulate standing. This posture was simulated by applying a vertical force of 500 N at the centre of the L1 vertebral endplate with different boundary conditions, by applying a follower load, and by applying upper body weight and muscle forces. The calculated intersegmental rotations and intradiscal pressures were compared to in vivo values.Intersegmental rotations at one level vary by up to 8° for the different loading modes simulating standing. The overall rotation in the lumbar spine varies between 2.2° and 19.5°. With a follower load, the difference to the value measured in vivo is 3.3°. For all other loading cases studied, the difference is greater than 6.6°. Intradiscal pressures vary slightly with the loading mode. Calculated forces in the facet joints vary between 0 and nearly 80 N.Applying a follower load of 500 N is the only loading mode simulating standing for which the calculated values for intervertebral rotations and intradiscal pressures agreed well with in vivo data from literature.  相似文献   

4.
Spine biomechanics   总被引:2,自引:0,他引:2  
Current trends in spine research are reviewed in order to suggest future opportunities for biomechanics. Recent studies show that psychosocial factors influence back pain behaviour but are not important causes of pain itself. Severe back pain most often arises from intervertebral discs, apophyseal joints and sacroiliac joints, and physical disruption of these structures is strongly but variably linked to pain. Typical forms of structural disruption can be reproduced by severe mechanical loading in-vitro, with genetic and age-related weakening sometimes leading to injury under moderate loading. Biomechanics can be used to quantify spinal loading and movements, to analyse load distributions and injury mechanisms, and to develop therapeutic interventions. The authors suggest that techniques for quantifying spinal loading should be capable of measurement "in the field" so that they can be used in epidemiological surveys and ergonomic interventions. Great accuracy is not required for this task, because injury risk depends on tissue weakness as much as peak loading. Biomechanical tissue testing and finite-element modelling should complement each other, with experiments establishing proof of concept, and models supplying detail and optimising designs. Suggested priority areas for future research include: understanding interactions between intervertebral discs and adjacent vertebrae; developing prosthetic and tissue-engineered discs; and quantifying spinal function during rehabilitation. "Mechanobiology" has perhaps the greatest future potential, because spinal degeneration and healing are both mediated by the activity of cells which are acutely sensitive to their local mechanical environment. Precise characterisation and manipulation of this environment will be a major challenge for spine biomechanics.  相似文献   

5.
Different modes of load applications are used to simulate flexion and extension of the upper body. It is not clear which loading modes deliver realistic results and allow the comparison of different studies.In a numerical study, a validated finite element model of the lumbar spine, ranging from the vertebra L1 to the disc L5–S1 was employed. Each of six different loading modes was studied for simulating flexion and extension, including pure moments, an eccentric axial force, using a wedged fixture, and applying upper body weight plus follower load plus muscle forces. Intersegmental rotations, intradiscal pressures and facet joint contact forces were calculated. Where possible, results were compared to data measured in vivo.The results of the loading modes studied show a large variance for some values. Outcome measures such as flexion angle and intradiscal pressure differed at a segment by up to 44% and 88%, respectively, related to their maximum values. Intradiscal pressure is mainly determined by the magnitude of the applied compressive force. For flexion maximum contact forces between 0 and 69 N are predicted in each facet joint for different loading modes. For both flexion and extension, applying upper body weight plus follower load plus muscle forces as well as a follower load together with a bending moment delivers results which agreed well with in vivo data from the literature.Choosing an adequate loading mode is important in spine biomechanics when realistic results are required for intersegmental rotations, intradiscal pressure and facet joint contact forces. Only then will results of different studies be comparable.  相似文献   

6.
Diurnal changes of intervertebral disc height are caused by high compressive loading during the day, which expulses fluid from the disc, and by osmotic pressure, which imbibes fluid into the disc at low loading. The aim of the present study was to determine the magnitude of diurnal changes in spine flexibility, intradiscal pressures and contact forces in the facet joints. A validated osseoligamentous finite element model of the lumbar spine was used to determine these quantities for morning and evening situations. Disc height varied by 10% for these two situations. Spine flexibility and facet joint forces were markedly higher in the evening than in the morning. Intradiscal pressures were higher in the morning than in the evening. The different spine flexibilities in the morning and evening should be taken into account during kinematical measurements. Predicted facet joint forces may be used for the designing and pre-clinical testing of artificial facet joint replacements.  相似文献   

7.
PurposeExternal knee moments are reliable to measure knee load but it does not take into account muscle activity. Considering that muscle co-activation increases compressive forces at the knee joint, identifying relationships between muscle co-activations and knee joint load would complement the investigation of the knee loading in subjects with knee osteoarthritis. The purpose of this study was to identify relationships between muscle co-activation and external knee moments during walking in subjects with medial knee osteoarthritis.Methods19 controls (11 males, aged 56.6 ± 5, and BMI 25.2 ± 3.3) and 25 subjects with medial knee osteoarthritis (12 males, aged 57.3 ± 5.3, and BMI 28.2 ± 4) were included in this study. Knee adduction and flexion moments, and co-activation (ratios and sums of quadriceps, hamstring, and gastrocnemius) were assessed during walking and compared between groups. The relationship between knee moments and co-activation was investigated in both groups.FindingsSubjects with knee osteoarthritis presented a moderate and strong correlation between co-activation (ratios and sums) and knee moments.InterpretationMuscle co-activation should be used to measure the contribution of quadriceps, hamstring, and gastrocnemius on knee loading. This information would cooperate to develop a more comprehensive approach of knee loading in this population.  相似文献   

8.
Background: Knee injuries are common during landing activities. Greater landing height increases peak ground reaction forces (GRFs) and loading at the knee joint. As major muscles to stabilize the knee joint, Quadriceps and Hamstring muscles provide internal forces to attenuate the excessive GRF. Despite the number of investigations on the importance of muscle function during landing, the role of landing height on these muscles forces using modeling during landing is not fully investigated. Methods: Participant-specific musculoskeletal models were developed using experimental motion analysis data consisting of anatomic joint motions and GRF from eight male participants performing double-leg drop landing from 30 and 60 cm. Muscle forces were calculated in OpenSim and their differences were analyzed at the instances of high risk during landing i.e. peak GRF for both heights. Results: The maximum knee flexion angle and moments were found significantly higher from a double-leg landing at 60 cm compared to 30 cm. The results showed elevated GRF, and mean muscle forces during landing. At peak GRF, only quadriceps showed significantly greater forces at 60 cm. Hamstring muscle forces did not significantly change at 60 cm compared to 30 cm. Conclusions: Quadriceps and hamstring muscle forces changed at different heights. Since hamstring forces were similar in both landing heights, this could lead to an imbalance between the antagonist muscles, potentially placing the knee at risk of injury if combined with small flexion angles that was not observed at peak GRF in our study. Thus, enhanced neuromuscular training programs strengthening the hamstrings may be required to address this imbalance. These findings may contribute to enhance neuromuscular training programs to prevent knee injuries during landing.  相似文献   

9.
High anterior intervertebral shear loads could cause low back injuries and therefore the neuromuscular system may actively counteract these forces. This study investigated whether, under constant moment loading relative to L3L4, an increased externally applied forward force on the trunk results in a shift in muscle activation towards the use of muscles with more backward directed lines of action, thereby reducing the increase in total joint shear force. Twelve participants isometrically resisted forward forces, applied at several locations on the trunk, while moments were held constant relative to L3L4. Surface EMG and lumbar curvature were measured, and an EMG-driven muscle model was used to calculate compression and shear forces at all lumbar intervertebral joints. Larger externally applied forward forces resulted in a flattening of the lumbar lordosis and a slightly more backward directed muscle force. Furthermore, the overall muscle activation increased. At the T12L1 to L3L4 joint, resulting joint shear forces remained small (less than 200N) because the average muscle force pulled backward relative to those joints. However, at the L5S1 joint the average muscle force pulled the trunk forward so that the increase in muscle force with increasing externally applied forward force caused a further rise in shear force (by 102.1N, SD=104.0N), resulting in a joint shear force of 1080.1N (SD=150.4N) at 50Nm moment loading. It is concluded that the response of the neuromuscular system to shear force challenges tends to increase rather than reduce the shear loading at the lumbar joint that is subjected to the highest shear forces.  相似文献   

10.
Evaluation of the loads on lumbar intervertebral discs (IVD) is critically important since it is closely related to spine biomechanics, pathology and prosthesis design. Non-invasive estimation of the loads in the discs remains a challenge. In this study, we proposed a new technique to estimate in vivo loads in the IVD using a subject-specific finite element (FE) model of the disc and the kinematics of the disc endplates as input boundary conditions. The technique was validated by comparing the forces and moments in the discs calculated from the FE analyses to the in vitro experiment measurements of three corresponding lumbar discs. The results showed that the forces and moments could be estimated within an average error of 20%. Therefore, this technique can be a promising tool for non-invasive estimation of the loads in the discs and may be extended to be used on living subjects.  相似文献   

11.
Abstract

The current paper aims at assessing the sensitivity of muscle and intervertebral disc force computations against potential errors in modeling muscle attachment sites. We perturbed each attachment location in a complete and coherent musculoskeletal model of the human spine and quantified the changes in muscle and disc forces during standing upright, flexion, lateral bending, and axial rotation of the trunk. Although the majority of the muscles caused minor changes (less than 5%) in the disc forces, certain muscle groups, for example, quadratus lumborum, altered the shear and compressive forces as high as 353% and 17%, respectively. Furthermore, percent changes were higher in the shear forces than in the compressive forces. Our analyses identified certain muscles in the rib cage (intercostales interni and intercostales externi) and lumbar spine (quadratus lumborum and longissimus thoracis) as being more influential for computing muscle and disc forces. Furthermore, the disc forces at the L4/L5 joint were the most sensitive against muscle attachment sites, followed by T6/T7 and T12/L1 joints. Presented findings suggest that modeling muscle attachment sites based on solely anatomical illustrations might lead to erroneous evaluation of internal forces and promote using anatomical datasets where these locations were accurately measured. When developing a personalized model of the spine, certain care should also be paid especially for the muscles indicated in this work.  相似文献   

12.
In biomechanics, musculoskeletal models are typically redundant. This situation is referred to as the distribution problem. Often, static, non-linear optimisation methods of the form “min: φ(f) subject to mechanical and muscular constraints” have been used to extract a unique set of muscle forces. Here, we present a method for validating this class of non-linear optimisation approaches where the homogeneous cost function, φ(f), is used to solve the distribution problem. We show that the predicted muscle forces for different loading conditions are scaled versions of each other if the joint loading conditions are just scaled versions. Therefore, we can calculate the theoretical muscle forces for different experimental conditions based on the measured muscle forces and joint loadings taken from one experimental condition and assuming that all input into the optimisation (e.g., moment arms, muscle attachment sites, size, fibre type distribution) and the optimisation approach are perfectly correct. Thus predictions of muscle force for other experimental conditions are accurate if the optimisation approach is appropriate, independent of the musculoskeletal geometry and other input required for the optimisation procedure. By comparing the muscle forces predicted in this way to the actual muscle forces obtained experimentally, we conclude that convex homogeneous non-linear optimisation approaches cannot predict individual muscle forces properly, as force-sharing among synergistic muscles obtained experimentally are not just scaled versions of joint loading, not even in a first approximation.  相似文献   

13.
Pedicle-screw-based motion preservation systems are often used to support a slightly degenerated disc. Such implants are intended to reduce intradiscal pressure and facet joints forces, while having a minimal effect on the motion patterns.In a probabilistic finite element study with subsequent sensitivity analysis, the effects of 10 input parameters, such as elastic modulus and diameter of the elastic rod, distraction of the segment, level of bridged segments, etc. on the output parameters intervertebral rotations, intradiscal pressures, and facet joint forces were determined. A validated finite element model of the lumbar spine was employed. Probabilistic studies were performed for seven loading cases: upright standing, flexion, extension, left and right lateral bending and left and right axial rotation.The simulations show that intervertebral rotation angles, intradiscal pressures and facet joint forces are in most cases reduced by a motion preservation system. The influence on intradiscal pressure is small, except in extension. For many input parameter combinations, the values for intervertebral rotations and facet joint forces are very low, which indicates that the implant is too stiff in these cases. The output parameters are affected most by the following input parameters: loading case, elastic modulus and diameter of the elastic rod, distraction of the segment, and angular rigidity of the connection between screws and rod.The designated functions of a motion preservation system can best be achieved when the longitudinal rod has a low stiffness, and when the connection between rod and pedicle screws is rigid.  相似文献   

14.
Abstract

The purpose of this paper is an investigation of the peculiarities of biarticular muscles by means of modelling and analytical solution of the indeterminate problem. The basic model includes 10 muscle elements performing flexio/extensio in the shoulder, elbow and wrist. Four of them are biarticular muscles. Two modifications of the model with only monoarticular muscles are developed. The indeterminate problem is solved analytically using the objective criterion σciFi 2 where F( is the module of the i-th muscle force and Cj is a weight coefficient. The predicted muscle forces, joint reactions and moments are compared in-between the basic model and its two modifications for different joint angles, external loading and weight coefficients. The main conclusions are: it is impossible to formulate strict advantages of the biarticular muscles under quasistatical conditions, their peculiarities depend on limb position, external loading and neural control; in general, monoarticular muscles are more powerful than biarticular ones; the biarticular muscles fine tune muscle coordination, their control is more precise and graceful; the presence of biarticular muscles leads to an increase of the joint reactions and moments, thus stabilizing the limb.  相似文献   

15.
The human spinal segment is an inherently complex structure, a combination of flexible and semi-rigid articulating elements stabilised by seven principal ligaments. An understanding of how mechanical loading is shared among these passive elements of the segment is required to estimate tissue failure stresses. A 3D rigid body model of the complete lumbar spine has been developed to facilitate the prediction of load sharing across the passive elements. In contrast to previous multibody models, this model includes a non-linear, six degrees of freedom intervertebral disc, facet bony articulations and all spinal ligaments. Predictions of segmental kinematics and facet joint forces, in response to pure moment loading (flexion–extension), were compared to published in vitro data. On inclusion of detailed representation of the disc and facets, the multibody model fully captures the non-linear flexibility response of the spinal segment, i.e. coupled motions and a mobile instantaneous centre of rotation. Predicted facet joint forces corresponded well with reported values. For the loading case considered, the model predicted that the ligaments are the main stabilising elements within the physiological motion range; however, the disc resists a greater proportion of the applied load as the spine is fully flexed. In extension, the facets and capsular ligaments provide the principal resistance. Overall patterns of load distribution to the spinal ligaments are in agreement with previous predictions; however, the current model highlights the important role of the intraspinous ligament in flexion and the potentially high risk of failure. Several important refinements to the multibody modelling of the passive elements of the spine have been described, and such an enhanced passive model can be easily integrated into a full musculoskeletal model for the prediction of spinal loading for a variety of daily activities.  相似文献   

16.
A possibility to simulate the mechanical behaviour of the human spine is given by modelling the stiffer structures, i.e. the vertebrae, as a discrete multi-body system (MBS), whereas the softer connecting tissue, i.e. the softer intervertebral discs (IVD), is represented in a continuum-mechanical sense using the finite-element method (FEM). From a modelling point of view, the mechanical behaviour of the IVD can be included into the MBS in two different ways. They can either be computed online in a so-called co-simulation of a MBS and a FEM or offline in a pre-computation step, where a representation of the discrete mechanical response of the IVD needs to be defined in terms of the applied degrees of freedom (DOF) of the MBS. For both methods, an appropriate homogenisation step needs to be applied to obtain the discrete mechanical response of the IVD, i.e. the resulting forces and moments. The goal of this paper was to present an efficient method to approximate the mechanical response of an IVD in an offline computation. In a previous paper (Karajan et al. in Biomech Model Mechanobiol 12(3):453–466, 2012), it was proven that a cubic polynomial for the homogenised forces and moments of the FE model is a suitable choice to approximate the purely elastic response as a coupled function of the DOF of the MBS. In this contribution, the polynomial chaos expansion (PCE) is applied to generate these high-dimensional polynomials. Following this, the main challenge is to determine suitable deformation states of the IVD for pre-computation, such that the polynomials can be constructed with high accuracy and low numerical cost. For the sake of a simple verification, the coupling method and the PCE are applied to the same simplified motion segment of the spine as was used in the previous paper, i.e. two cylindrical vertebrae and a cylindrical IVD in between. In a next step, the loading rates are included as variables in the polynomial response functions to account for a more realistic response of the overall viscoelastic intervertebral disc. Herein, an additive split into elastic and inelastic contributions to the homogenised forces and moments is applied.  相似文献   

17.
ObjectiveInvestigate shoulder joint kinetics over a range of daily activity and mobility tasks associated with manual wheelchair propulsion to characterize demands placed on the shoulder during the daily activity of manual wheelchair users.DesignCase series.SubjectsTwelve individuals who were experienced manual wheelchair users.MethodsUpper extremity kinematics and handrim wheelchair kinetics were measured over level propulsion, ramp propulsion, start and stop over level terrain, and a weight relief maneuver. Shoulder intersegmental forces and moments were calculated from inverse dynamics for all conditions.ResultsWeight relief resulted in significantly higher forces and ramp propulsion resulted in significantly higher moments than the other conditions. Surprisingly, the start condition resulted in large intersegmental moments about the shoulder equivalent with that of the ramp propulsion, while the demand imparted by the stop condition was shown to be equivalent to level propulsion across all forces and moments.ConclusionsThis study provides characterization of daily living and mobility activities associated with manual wheelchair propulsion not previously reported and identifies activities that result in higher shoulder kinetics when compared to standard level propulsion.  相似文献   

18.
Little work has been done to examine the deep squat position (>130° sagittal knee flexion). In baseball and softball, catchers perform this squat an average of 146 times per nine-inning game. To alleviate some of the stress on their knees caused by this repetitive loading, some catchers wear foam knee supports.ObjectivesThis work quantifies the effects of knee support on lower-body joint kinematics and kinetics in the deep squat position.MethodsSubjects in this study performed the deep squat with no support, foam support, and instrumented support. In order to measure the force through the knee support, instrumented knee supports were designed and fabricated. We then developed an inverse dynamic model to incorporate the support loads. From the model, joint angles and moments were calculated for the three conditions.ResultsWith support there is a significant reduction in the sagittal moment at the knee of 43% on the dominant side and 63% on the non-dominant side compared to without support. These reductions are a result of the foam supports carrying approximately 20% of body weight on each side.ConclusionKnee support reduces the moment necessary to generate the deep squat position common to baseball catchers. Given the short moment arm of the patella femoral tendon, even small changes in moment can have a large effect in the tibial-femoral contact forces, particularly at deep squat angles. Reducing knee forces may be effective in decreasing incidence of osteochondritis dissecans.  相似文献   

19.
Presently, there is little consensus about how, or even if, axial preload should be incorporated in spine flexibility tests in order to simulate the compressive loads naturally present in vivo. Some preload application methods are suspected of producing unwanted “artefact” forces as the specimen rotates and, in doing so, influencing the resulting kinematics. The objective of this study was to quantitatively compare four distinct types of preload which have roots in contemporary experimental practice. The specific quantities compared were the reaction moments and forces resulting at the intervertebral disc and specimen kinematics. The preload types incorporated increasing amounts of caudal constraint on the preload application vector ranging from an unconstrained dead-load arrangement to an apparatus that allowed the vector to follow rotations of the specimen. Six human cadaveric spine segments were tested (1-L1/L2, 3-L2/L3, 1-L3/L4 and 1-L4/L5). Pure moments were applied to the specimens with each of the four different types of compressive preload. Kinematic response was measured using an opto-electronic motion analysis system. A six-axis load cell was used to measure reaction forces and moments. Artefact reaction moments and shear forces were significantly affected by preload application method and magnitude. Unconstrained preload methods produced high artefact moments and low artefact shear forces while more constrained methods did the opposite. A mechanical trade-off is suggested by our results, whereby unwanted moment can only be prevented at the cost of shear force production. When comparing spine flexibility studies, caution should be exercised to ensure preload was applied in a similar manner for all studies. Unwanted moments or forces induced as a result of preload application method may render the comparison of two seemingly similar studies inappropriate.  相似文献   

20.
《Endocrine practice》2014,20(12):1315-1318
ObjectiveWe hypothesized that variability from year to year in how much of the bone map was filled in at the bottom of the spine region of interest (ROI) contributes substantially to variability in measurement of spine bone mineral density (BMD).MethodsA total of 110 spine BMDs with defects in the bone mapping at the bottom were reanalyzed, with the only change being manually drawing a straight line across the bottom of the ROI and filling in the bone map.ResultsThe mean (SD) change in area, bone mineral content, and BMD for total spine when the bottom of the bone map was filled in was 0.919 (0.411) cm2, 0.201 (0.121) g, and -0.0098 (0.0043) g/cm2, respectively, and all changes were significant (P < .0001). The largest individual change in total spine BMD with reanalysis was 0.0238 g/ cm2, close to the least significant change (LSC) of 0.026 g/cm2 in our center. To quantify variability due to this change in analysis, we calculated an LSC(fill), in which the pairs of scans consisted of the same scan before and after filling in the bottom of the spine bone map, without any other change. The LSC(fill) attributable just to the reanalysis of missing bone map at the bottom of the spine was 0.021 g/cm2, suggesting substantial variance due to variability in mapping the bottom of the spine.ConclusionWhen there is a noticeable defect in the bottom of the spine bone map, filling this defect in consistently eliminates a significant source of variability in analysis of spine BMDs and might allow us to achieve smaller LSCs. (Endocr Pract. 2014;20:1315-1318)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号