共查询到20条相似文献,搜索用时 15 毫秒
1.
Mateus Bertolini Fernandes dos Santos Gabriel de Oliveira Meloto Ataís Bacchi Lourenço Correr-Sobrinho 《Computer methods in biomechanics and biomedical engineering》2017,20(8):893-900
Factors related to micromovements at bone-implant interface have been studied because they are considered adverse to osseointegration. Simplifications are commonly observed in these FEA evaluations. The aim of this study was to clarify the influence of FEA parameters (boundary conditions and bone properties) on the stress distribution in peri-implant bone tissue when micromovements are simulated in implants with different geometries. Three-dimensional models of an anterior section of the jaw with cylindrical or conical titanium implants (4.1 mm in width and 11 mm in length) were created. Micromovement (50, 150, or 250 μm) was applied to the implant. The FEA parameters studied were linear vs. non-linear analyses, isotropic vs. orthogonal anisotropic bone, friction coefficient (0.3) vs. frictionless bone-implant contact. Data from von Mises, shear, maximum, and minimum principal stresses in the peri-implant bone tissue were compared. Linear analyses presented a relevant increase of the stress values, regardless of the bone properties. Frictionless contact reduced the stress values in non-linear analysis. Isotropic bone presented lower stress than orthogonal anisotropic. Conical implants behave better, in regard to compressive stresses (minimum principal), than cylindrical ones, except for nonlinear analyses when micromovement of 150 and 250 μm were simulated. The stress values raised as the micromovement amplitude increased. Non-linear analysis, presence of frictional contact and orthogonal anisotropic bone, evaluated through maximum and minimum principal stress should be used as FEA parameters for implant-micromovement studies. 相似文献
2.
Bruno Salles Sotto-Maior Emílio Graciliano Ferreira Mercuri Plinio Mendes Senna Neuza Maria Souza Picorelli Assis Carlos Eduardo Francischone Altair Antoninha Del Bel Cury 《Computer methods in biomechanics and biomedical engineering》2016,19(7):699-706
Algorithmic models have been proposed to explain adaptive behavior of bone to loading; however, these models have not been applied to explain the biomechanics of short dental implants. Purpose of present study was to simulate bone remodeling around single implants of different lengths using mechanoregulatory tissue differentiation model derived from the Stanford theory, using finite elements analysis (FEA) and to validate the theoretical prediction with the clinical findings of crestal bone loss. Loading cycles were applied on 7-, 10-, or 13-mm-long dental implants to simulate daily mastication and bone remodeling was assessed by changes in the strain energy density of bone after a 3, 6, and 12 months of function. Moreover, clinical findings of marginal bone loss in 45 patients rehabilitated with same implant designs used in the simulation (n = 15) were computed to validate the theoretical results. FEA analysis showed that although the bone density values reduced over time in the cortical bone for all groups, bone remodeling was independent of implant length. Clinical data showed a similar pattern of bone resorption compared with the data generated from mathematical analyses, independent of implant length. The results of this study showed that the mechanoregulatory tissue model could be employed in monitoring the morphological changes in bone that is subjected to biomechanical loads. In addition, the implant length did not influence the bone remodeling around single dental implants during the first year of loading. 相似文献
3.
Wei Xiao Zhiyong Li Shiqian Shen Shaowu Chen Sulin Chen 《Computer methods in biomechanics and biomedical engineering》2016,19(3):240-247
Few studies are performed to evaluate the influence of connection type on the stress distribution of distal extension mandibular removable partial dentures (RPDs) supported by both implants and natural teeth. In this study, five three-dimensional finite element models were prepared to simulate mandibular bilateral partially edentulous arches. Four were RPDs supported by both implants and natural teeth, and the other one was RPDs supported only by natural teeth. The maximum equivalent (EQV) stress values of bone around implants, the abutments, and the mucosa displacements of the related supporting structures were measured. It was found that a non-rigid telescopic coping was more favorable to protect the implant than a rigid telescopic coping. Compared with other connection types, the easy resilient attachment (ERA) system seemed to be effective to associate implant without complications. However, the results obtained in the present study should be cautiously interpreted in the clinic. 相似文献
4.
Shih-Hao Chang Shiang-Rung Huang Shao-Fu Huang 《Computer methods in biomechanics and biomedical engineering》2016,19(8):911-921
This study investigates the bone/implant mechanical responses in an implant overdenture retained by ball attachments on two conventional regular dental implants (RDI) and four mini dental implants (MDI) using finite element (FE) analysis. Two FE models of overdentures retained by RDIs and MDIs for a mandibular edentulous patient with validation within 6% variation errors were constructed by integrating CT images and CAD system. Bone grafting resulted in 2 mm thickness at the buccal side constructed for the RDIs-supported model to mimic the bone augmentation condition for the atrophic alveolar ridge. Nonlinear hyperelastic material and frictional contact element were used to simulate characteristic of the ball attachment-retained overdentures. The results showed that a denture supported by MDIs presented higher surrounding bone strains than those supported by RDIs under different load conditions. Maximum bone micro strains were up to 6437/2987 and 13323/5856 for MDIs/RDIs under single centric and lateral contacts, respectively. Corresponding values were 4429/2579 and 9557/5774 under multi- centric and lateral contacts, respectively. Bone micro strains increased 2.06 and 1.96-folds under single contact, 2.16 and 2.24-folds under multiple contacts for MDIs and RDIs when lateral to axial loads were compared. The maximum RDIs and MDIs implant stresses in all simulated cases were found by far lower than their yield strength. Overdentures retained using ball attachments on MDIs in poor edentulous bone structure increase the surrounding bone strain over the critical value, thereby damaging the bone when compared to the RDIs. Eliminating the occlusal single contact and oblique load of an implant-retained overdenture reduces the risk for failure. 相似文献
5.
Victor Eduardo de Souza Batista Fellippo Ramos Verri Daniel Augusto de Faria Almeida Joel Ferreira Santiago Junior Cleidiel Aparecido Araújo Lemos Eduardo Piza Pellizzer 《Computer methods in biomechanics and biomedical engineering》2017,20(6):663-670
The aim of this study was to evaluate the influence of pontic and cantilever designs (mesial and distal) on 3-unit implant-retained prosthesis at maxillary posterior region verifying stress and strain distributions on bone tissue (cortical and trabecular bones) and stress distribution in abutments, implants and fixation screws, under axial and oblique loadings, by 3D finite element analysis. Each model was composed of a bone block presenting right first premolar to the first molar, with three or two external hexagon implants (4.0 × 10 mm), supporting a 3-unit splinted dental fixed dental prosthesis with the variations: M1 – three implants supporting splinted crowns; M2 – two implants supporting prosthesis with central pontic; M3 – two implants supporting prosthesis with mesial cantilever; M4 – two implants supporting prosthesis with distal cantilever. The applied forces were 400 N axial and 200 N oblique. The von Mises criteria was used to evaluate abutments, implants and fixation screws and maximum principal stress and microstrain criteria were used to evaluate the bone tissue. The decrease of the number of implants caused an unfavorable biomechanical behavior for all structures (M2, M3, M4). For two implant-supported prostheses, the use of the central pontic (M2) showed stress and strain distributions more favorable in the analyzed structures. The use of cantilever showed unfavorable biomechanical behavior (M3 and M4), mainly for distal cantilever (M4). The use of three implants presented lower values of stress and strain on the analyzed structures. Among two implant-supported prostheses, prostheses with cantilever showed unfavorable biomechanical behavior in the analyzed structures, especially for distal cantilever. 相似文献
6.
V. Demenko I. Linetsky V. Nesvit L. Linetska A. Shevchenko 《Computer methods in biomechanics and biomedical engineering》2014,17(16):1751-1761
Extreme stresses in surrounding bone are among the most important reasons for implant failure. Bone density (quality) is a variable that plays a decisive role in achieving predictable osseointegration and long-term survival of implants. The magnitudes of ultimate occlusal load, which generate ultimate von Mises stress at the critical point of peri-implant area for the spectrum of implants inserted into mandible with four different bone qualities (Lekholm and Zarb classification), were calculated. Geometric models of mandible segment were generated from computed tomography images and analysed with osseointegrated cylindrical implants of various dimensions. Occlusal loads were applied in their natural direction. All materials were assumed to be linearly elastic and isotropic. The investigation suggests that an implant's ultimate occlusal load indicates its load-carrying capacity. As a result, bone loss can be predicted, and viable implants can be selected by comparing the values of their ultimate occlusal load in different clinical conditions. 相似文献
7.
Fellippo Ramos Verri Ronaldo Silva Cruz Cleidiel Aparecido Araújo Lemos Victor Eduardo de Souza Batista Daniel Augusto Faria Almeida Ana Caroline Gonçales Verri 《Computer methods in biomechanics and biomedical engineering》2017,20(2):193-200
The aim of study was to evaluate the stress distribution in implant-supported prostheses and peri-implant bone using internal hexagon (IH) implants in the premaxillary area, varying surgical techniques (conventional, bicortical and bicortical in association with nasal floor elevation), and loading directions (0°, 30° and 60°) by three-dimensional (3D) finite element analysis. Three models were designed with Invesalius, Rhinoceros 3D and Solidworks software. Each model contained a bone block of the premaxillary area including an implant (IH, Ø4 × 10 mm) supporting a metal-ceramic crown. 178 N was applied in different inclinations (0°, 30°, 60°). The results were analyzed by von Mises, maximum principal stress, microstrain and displacement maps including ANOVA statistical test for some situations. Von Mises maps of implant, screws and abutment showed increase of stress concentration as increased loading inclination. Bicortical techniques showed reduction in implant apical area and in the head of fixation screws. Bicortical techniques showed slight increase stress in cortical bone in the maximum principal stress and microstrain maps under 60° loading. No differences in bone tissue regarding surgical techniques were observed. As conclusion, non-axial loads increased stress concentration in all maps. Bicortical techniques showed lower stress for implant and screw; however, there was slightly higher stress on cortical bone only under loads of higher inclinations (60°). 相似文献
8.
Wirley Gonçalves Assunçāo Valentim Adelino Ricardo Barāo Lucas Fernando Tabata Edson Antonio Capello De Sousa Erica Alves Gomes Juliana Aparecida Delben 《Gerodontology》2009,26(4):273-281
Background: The effect of different mucosa characteristics on stress distribution of complete dentures and overdentures remains unknown. Objective: The aim of this study was to evaluate the effect of different mucosa thickness and resiliency on the stress distribution of complete dentures and implant‐retained overdentures using a two‐dimensional finite element analysis. Material and methods: Representative models of the edentulous mandible were constructed on AutoCAD software according to the groups’ characteristics. In group CD, a model of the edentulous mandible supporting a complete denture was obtained while in group IO, a model of edentulous mandible supporting an overdenture over two unsplinted implants with an o’ ring system was constructed. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) corresponding to the resiliencies hard, resilient and soft respectively. Evaluation was performed on Ansys software with 100N vertical load applied on central incisor teeth. The principal stress was used as analysis criteria. Results: Group IO showed higher stress values than group CD regardless of mucosal thickness and resiliency. Stress decreased at the supporting tissues in both groups as the thickness and resiliency of mucosa increased. In relation to the supporting tissues, cortical bone showed the highest stress values. Conclusion: It was concluded that the use of an attachment system increases stress values and the thickness and resiliency of mucosa influence more on these values. 相似文献
9.
K. Solberg F. Heinemann P. Pellikaan L. Keilig C. Bourauel 《Computer methods in biomechanics and biomedical engineering》2017,20(7):770-782
The effect of implants’ number on overdenture stability and stress distribution in edentulous mandible, implants and overdenture was numerically investigated for implant-supported overdentures. Three models were constructed. Overdentures were connected to implants by means of ball head abutments and rubber ring. In model 1, the overdenture was retained by two conventional implants; in model 2, by four conventional implants; and in model 3, by five mini implants. The overdenture was subjected to a symmetrical load at an angle of 20 degrees to the overdenture at the canine regions and vertically at the first molars. Four different loading conditions with two total forces (120, 300 N) were considered for the numerical analysis. The overdenture displacement was about 2.2 times higher when five mini implants were used rather than four conventional implants. The lowest stress in bone bed was observed with four conventional implants. Stresses in bone were reduced by 61% in model 2 and by 6% in model 3 in comparison to model 1. The highest stress was observed with five mini implants. Stresses in implants were reduced by 76% in model 2 and 89% increased in model 3 compared to model 1. The highest implant displacement was observed with five mini implants. Implant displacements were reduced by 29% in model 2, and increased by 273% in model 3 compared to model 1. Conventional implants proved better stability for overdenture than mini implants. Regardless the type and number of implants, the stress within the bone and implants are below the critical limits. 相似文献
10.
M. R. Matson H. R. Lewgoy R. Amore A. Anido-Anido R. C.B. Alonso 《Computer methods in biomechanics and biomedical engineering》2013,16(8):795-800
The aim of this study was to investigate the stress distribution generated in a veneer restoration of an upper central incisor compared to intact teeth using the finite element analysis after applying a lingual buccal loading at the incisal edge. Methods: Two models were developed: one model contained enamel, dentine, cementum, periodontal ligament, cortical and trabecullar bones, and the other model was a veneer restoration; both models were developed using MSC/Nastran software (MacNeal-Schwendler Corporation, Los Angeles, CA, USA) as the pre- and post-processor. A 10-N load was applied at the incisal edge from the lingual to the buccal side to simulate oral conditions in this area (protrusion). Results: Von Mises stresses were then analysed for three different regions: A-B (enamel elements under the veneer or second enamel layer), A′-B′ (buccal enamel and/or veneer element layer) and C-D (lingual enamel elements layer). A higher stress mode was observed for both models at the lingual cervical region. Conclusions: The presence of a veneer restoration on the incisors is a good alternative to mimic the behaviour of enamel under protrusion loading conditions. The use of veneers to replace enamel during rehabilitations is recommended. 相似文献
11.
Eduardo Borie Eduardo Leal Iara Augusta Orsi Carlos Salamanca Fernando José Dias Benjamin Weber 《Computer methods in biomechanics and biomedical engineering》2018,21(1):91-97
The aim of this study was to analyze the influence of three different transmucosal heights of the abutments in single and multiple implant-supported prostheses through the finite element method. External hexagon implants, MicroUnit, and EsthetiCone abutments were scanned and placed in an edentulous maxillary model obtained from a tomography database. The simulations were divided into two groups: (1) one implant with 3.75 × 10 mm placed in the upper central incisor, simulating a single implant-supported fixed prosthesis with an EsthetiCone abutment; and (2) two implants with 3.75 × 10 mm placed in the upper lateral incisors with MicroUnit abutments, simulating a multiple implant-supported prosthesis. Subsequently, each group was subdivided into three models according to the transmucosal height (1, 2, and 3 mm). A static oblique load at an angle of 45 degrees to the long axis of the implant in palatal-buccal direction of 150 and 75 N was applied for multiple and single implant-supported prosthesis, respectively. The implants and abutments were assessed according to the equivalent Von Mises stress analyses while the bone and ceramics were analyzed through maximum and minimum principal stresses. The total deformation values increased in all models, while the transmucosal height was augmented. The transmucosal height of the abutments influences the stress values at the bone, ceramics, implants, and abutments of both the single and multiple implant-supported prostheses, with the transmucosal height of 1 mm showing the lowest stress values. 相似文献
12.
Immediate loading(IL)increases the risk of marginal bone loss.The present study investigated the biomechanical response of peri-implant bone in rabbits after IL,aiming at optimizing load management.Ninety-six implants were installed bilaterally into femurs of 48 rabbits.Test implants on the left side created the maximal initial stress of 6.9 and 13.4 MPa in peri-implant bone and unloaded implants on the contralateral side were controls.Bone morphology and bone-implant interface strength were measured with histological examination and push-out testing during a 12-week observation period.Additionally,the animal data were incorporated into finite element(FE)models to calculate the bone stress distribution at different levels of osseointegration.Results showed that the stress was concentrated in the bone margin and the bone stress gradually decreased as osseointegration proceeded.A stress of about 2.0 MPa in peri-implant bone had a positive effect on new bone formation,osseointegration and bone-implant interface strength.Bone loss was observed in some specimens with stress exceeding 4.0 MPa.Data indicate that IL significantly increases bone stress during the early postoperative period,but the load-bearing capacity of peri-implant bone increases rapidly with an increase of bone-implant contact.Favorable bone responses may be continually promoted when the stress in peri-implant bone is maintained at a definite level.Accordingly,the progressive loading mode is recommended for IL implants. 相似文献
13.
Sercan Küçükkurt Gökhan Alpaslan Ahmet Kurt 《Computer methods in biomechanics and biomedical engineering》2017,20(3):284-293
Objective: In this study, we compared the success of sinus lifting and alternative treatment methods in applying dental implants in cases lacking adequate bone due to pneumatization of the maxillary sinus. Methods: In a computer environment, 3D models were created using computerized tomography data from a patient. Additionally, implants and abutments were scanned at the macroscopic level, and the resulting images were transferred to the 3D models. Five different models were examined: a control model, lateral sinus lifting (LSL), short dental implant placement (SIP), tilted implant placement (TIP) and distal prosthetic cantilever (DC) use. Vertical and oblique forces were applied in each model. The compression, tension and von Mises stresses in each model were analyzed by implementing a finite element analysis method. Results: In our study, the LSL method was observed to be the closest to the control model. The TIP model showed high stress values under conditions of oblique forces but showed successful results under conditions of vertical forces, and the opposite results were observed in the SIP model. The DC model provided the least successful results among all models. Conclusions: Based on the results of this study, the LSL method should be the first choice among treatment options. Considering its successful results under conditions of oblique forces, the SIP method may be preferable to the TIP method. In contrast, every effort should be made to avoid the use of DCs. 相似文献
14.
B. R. da Silva J. J.S. Moreira Neto F. I. da Silva Jr A. S.W. de Aguiar 《Computer methods in biomechanics and biomedical engineering》2013,16(2):158-164
Dental trauma is one of the most common events in dental practice. However, few studies have investigated the biomechanical characteristics of these injuries. The objective of this study was to analyse the stress distribution in the dentoalveolar structures of a maxillary central incisor subjected to two situations of impact loading. The following loading forces were applied using a 3D finite element model: a force of 2000 N acting at an angle of 90°on the buccal surface of the crown and a vertical 2000 N force acting in the cleidocranial direction on the incisal surface of the tooth. Harmful stresses were observed in both situations, causing damage to both the tooth and adjacent tissue. However, the damage found in soft tissues such as periodontal ligament and dental pulp was negligible. In conclusion, injuries resulting from the traumatic situations were more damaging to the integrity of the tooth and its associated hard-tissue structures. 相似文献
15.
I. Hasan L. Keilig S. Reimann F. Heinemann 《Computer methods in biomechanics and biomedical engineering》2013,16(12):1113-1116
It is always recommended to use more implants for supporting a prosthesis in the immediate loading condition than in the classical two-stage treatment procedure. By means of the finite element (FE) method, the influence of the number of implants used in immediately loaded fixed partial prosthesis (FPP) on the load distribution was investigated, considering the abutment geometry. Two 3D FE models were studied employing four implants to support a FPP in the premaxilla. One model was designed with straight abutments and the other with 20°-angled abutments. The results concerning implant displacements, stresses and strains were compared with those of two implant-supported FPPs, obtained in a previous study. A noticeable reduction in the determined biomechanical bone loading was observed with the use of more implants in supporting an immediately loaded prosthesis. This study confirms that the use of additional numbers of implants in an immediately loaded prosthesis is highly recommended. 相似文献
16.
Francesco Genna Corrado Paganelli Stefano Salgarello Pierluigi Sapelli 《Computer methods in biomechanics and biomedical engineering》2013,16(5-6):305-318
We consider a non-standard design for a fixed dental implant, incorporating a soft layer which simulates the presence of the periodontal ligament (PDL). Instead of being aimed at causing an a priori defined stress/strain field within the surrounding bone, upon loading, such a design simply tries to better reproduce the natural tooth–PDL configuration. To do this, the mechanical properties of the internal layer match those of the PDL, determined experimentally to be strongly nonlinear. Three-dimensional finite element analyses show that the presence of such a layer produces (i) a prosthesis mobility very similar to that of a healthy tooth, for several loading conditions, and (ii) a stress/strain distribution substantially different from that arising, upon loading, around a conventional implant. The lack of knowledge of the real mechanical fields existing, under loading, in the bone around a healthy tooth makes it very difficult to state that the stress distribution produced by the modified implant is “better” than that produced by the standard one. Nevertheless, the comparison of the results obtained here, with those of previous refined analyses of the tooth–PDL–bone system, indicates that the modified implant tends to produce a stress distribution in the bone, upon loading, closer to “natural” than that given by the standard one, within the limits imposed by the presence of threads coupling the implant with the bone. 相似文献
17.
Amilcar Chagas Freitas Júnior Paulo Henrique dos Santos Ching-Chang Ko Manoel Martín Júnior Erika Oliveira de Almeida 《Computer methods in biomechanics and biomedical engineering》2013,16(5):515-521
This study aimed to evaluate the influence of loading on a maxillary central incisor with the periodontal ligament (PDL) represented by 2D elastic beam elements using a 2D finite element analysis. Two models (M) were built varying the PDL representation: Mh (homogeneous PDL) and Mht (heterogeneous PDL with beam3 elements). Stress and displacements were determined for three loading conditions (L): Ll, lingual face loading at 45° with the tooth long axis; Li, perpendicular to the incisal edge; and Lip, on the incisal edge, parallel to the tooth long axis. Evaluation was performed on ANSYS software. Lip provided lower stress variation on the tooth and support structures when compared to Ll and Li. PDL's influence on stress values was lower for Lip. Oblique loading showed stress and displacement not observed in parallel loading condition through PDL's heterogeneous representation and it is probably incompatible with the in vivo condition. 相似文献
18.
Jianyu Chen Xianshuai Chen Xiao Zhang 《Computer methods in biomechanics and biomedical engineering》2017,20(6):636-644
Due to the increasing adoption of immediate implantation strategies and the rapid development of the computer aided design/computer aided manufacturing technology, a therapeutic concept based on patient-specific implant dentistry has recently been reintroduced by many researchers. However, little information is available on the designs of custom-made dental implant systems, especially their biomechanical behavior. The influence of the custom-made implant designs on the biomechanical performance for both an immediate and a delayed loading protocol in the maxillary esthetic zone was evaluated by means of the finite element (FE) method. FE models of three dental implants were considered: a state of the art cylindrical implant and two custom-made implants designed by reverse engineering technology, namely a root-analogue implant and a root-analogue threaded implant. The von Mises stress distributions and micro-motions around the bone-implant interfaces were calculated using ANSYS software. In a comparison of the three implant designs for both loading protocols, a favorable biomechanical performance was observed for the use of root-analogue threaded implant which approximated the geometry of natural anterior tooth and maintained the original long-axis. The results indicated that bone-implant interfacial micro-motion was reduced and a favorable stress distribution after osseointegration was achieved. 相似文献
19.
Elder Michael Andrango Castro Svatava Konvickova Matej Daniel Zdenek Horak 《Computer methods in biomechanics and biomedical engineering》2017,20(14):1494-1501
The aim of our study was to identify potential critical levels of implantation of an osseointegrated prosthesis for above-knee amputees. The implant used was the OPRA system. It was inserted in the femur at four different amputation heights, characterized by their residual limb ratios (0.299, 0.44, 0.58 and 0.73). The stress and strain distribution was evaluated in the bone-implant system during walking, considering a body mass of 100 kg. Considerably high stimulus (11,489 με) in the tissue near the tip was found at the highest implantation level. All models presented small non-physiologic stress values in the tissue around the implant. The results revealed that the implantation level has a decisive effect on bone-implant performance. Mainly, the analysis indicates adverse biomechanical conditions for implantations in very short residual limbs. 相似文献
20.
Zhan Liu Yingli Qian Yuanli Zhang 《Computer methods in biomechanics and biomedical engineering》2016,19(2):137-143
The aim of this study was to evaluate stress distributions in the temporomandibular joints (TMJs) with temporomandibular disorders (TMDs) for comparison with healthy TMJs. A model of mandible and normal TMJs was developed according to CT images. The interfaces between the discs and the articular cartilages were treated as contact elements. Nonlinear cable elements were used to simulate disc attachments. Based on this model, seven models of various TMDs were established. The maximum stresses of the discs with anterior, posterior, medial and lateral disc displacement (ADD, PDD, MDD and LDD) were 12.09, 9.33, 10.71 and 6.07 times magnitude of the identically normal disc, respectively. The maximum stresses of the posterior articular eminences in ADD, PDD, MDD, LDD, relaxation of posterior attachments and disc perforation models were 21, 59, 46, 21, 13 and 15 times greater than the normal model, respectively. TMDs could cause increased stresses in the discs and posterior articular eminences. 相似文献