1.
Objective: To evaluate the practical use of the mandibular advancement device (MAD) for treatment of sleep apnoea (SA) in patients with congestive heart failure (CHF) over 1 year. Subjects: Twenty‐five patients aged 66 ± 8 years (mean ± SD) met the inclusion criteria and were included in the study. Design: In a prospective, clinical trial, the apnoea‐hypopnoea index (AHI), a measure of SA, was determined with a portable device. Failure to enter treatment and compliance, adverse events and signs and symptoms of temporomandibular disorders (TMD) were examined before intervention and 4–6 weeks, 6 months, and 1 year after intervention. Results: Six patients had removable dentures of whom four had complete dentures. Before treatment, eight patients reported minor symptoms of TMD. The AHI fell from 19.3 ± 12.1 to 11.8 ± 9.5 (p = 0.004) with use of the device. In most patients, use of the MAD had no severe effects on the signs and symptoms of TMD. Adverse events such as pain in the temporomandibular joints, soreness in the teeth, and tiredness in the jaws were reported by 10 patients. Dental complications were observed in two patients. Sixty‐four per cent of the patients were still using the MAD at the 1‐year follow‐up. Conclusions: Both the general and oral health of CHF patients were important in treatment with a MAD. The MAD therapy had no severe effect on the masticatory system and edentulous patients could be treated.  相似文献   

2.
Vascular access methods, performed by the insertion of cannulae into vessels, may disturb the physiological flow of blood, giving rise to non-physiological pressure variations and shear stresses. To date, the hydrodynamic behaviour of the cannulae has been evaluated comparing their pressure loss–flow rate relationships, as obtained from in vitro experiments using a monodimensional approach; this methodology neither furnish information about the local fluid dynamics nor the established flow field in specific clinical work conditions. Since the shear stress is a critical factor in the design of artificial circulatory devices, more knowledge should be necessary about the local values assumed by the haemodynamic parameters during cannulation. An alternative way to investigate the fluid dynamic as accurately as possible is given by numeric studies. A 3D model of cannula concentrically placed in a rigid wall vessel is presented, with the finite element methodology used to numerically simulate the steady-state flow field in two different venous cannulation case studies, with two cannulae having a central hole and two or four side holes, respectively, with the same boundary conditions. Lower velocity and shear stress peak values have been computed for the model with four side holes upstream of the central hole, in the region of the cannula where the inlet flows meet and towards cannula's outlet, due to the increased flow symmetry and inlet area with respect to the model with two side holes. Starting from the investigation of different cannula designs, numerically assessing the local fluid dynamics, indications can be drawn to support both the design phase and the device optimal clinical use, in order to limit risks of biomechanical origin. Thus the presence of four side holes implied, as a consequence of the greater inlet area and of the increased symmetry, a less disturbed blood flow, together with reduced shear stress values. Furthermore, results show that the numerical simulations furnished useful informations on the interaction between vessel and cannula, e.g. on the fluid dynamics establishing in the free luminal space left, in the vessel, by the inserted cannula.  相似文献   

3.
Medial knee osteoarthritis is a debilitating disease. Surgical and conservative interventions are performed to manage its progression via reduction of load on the medial compartment or equivalently its surrogate measure, the external adduction moment. However, some studies have questioned a correlation between the medial load and adduction moment. Using a musculoskeletal model of the lower extremity driven by kinematics–kinetics of asymptomatic subjects at gait midstance, we aim here to quantify the relative effects of changes in the knee adduction angle versus changes in the adduction moment on the joint response and medial/lateral load partitioning. The reference adduction rotation of 1.6° is altered by ±1.5° to 3.1° and 0.1° or the knee reference adduction moment of 17 N m is varied by ±50% to 25.5 N m and 8.5 N m. Quadriceps, hamstrings and tibiofemoral contact forces substantially increased as adduction angle dropped and diminished as it increased. The medial/lateral ratio of contact forces slightly altered by changes in the adduction moment but a larger adduction rotation hugely increased this ratio from 8.8 to a 90 while in contrast a smaller adduction rotation yielded a more uniform distribution. If the aim in an intervention is to diminish the medial contact force and medial/lateral load ratio, a drop of 1.5° in adduction angle is much more effective (causing respectively 12% and 80% decreases) than a reduction of 50% in the adduction moment (causing respectively 4% and 13% decreases). Substantial role of changes in adduction angle is due to the associated alterations in joint nonlinear passive resistance. These findings explain the poor correlation between knee adduction moment and tibiofemoral compartment loading during gait suggesting that the internal load partitioning is dictated by the joint adduction angle.  相似文献   

4.
Irritable bowel syndrome (IBS) is a highly prevalent gastrointestinal disorder characterized by periods of remission and exacerbation. Among the risk factors to develop IBS, psychosocial stress is widely acknowledged. The water avoidance stress repeatedly applied (rWAS) is considered effective to study IBS etio-pathogenesis. Otilonium bromide (OB), a drug with multiple mechanisms of action, is largely used to treat IBS patients. Orally administered, it concentrates in the large bowel and significantly ameliorates the IBS symptomatology. Presently, we tested whether rWAS rats developed neuro-muscular abnormalities in the distal colon and whether OB treatment prevented them. The investigation was focussed on the nitrergic neurotransmission by combining functional and morphological methodologies. The results confirm rWAS as reliable animal model to investigate the cellular mechanisms responsible for IBS: exposure to one-hour psychosocial stress for 10 days depressed muscle contractility and increased iNOS expression in myenteric neurons. OB treatment counteracted these effects. We hypothesize that these effects are due to the corticotropin-releasing factor (CRF) release, the main mediator of the psychosocial stress, followed by a CRF1receptor activation. OB, that was shown to prevent CRF1r activation, reasonably interrupted the cascade events that bring to the mechanical and immunohistochemical changes affecting rWAS rat colon.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号