首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Development and application of advanced mechanical models of soft tissues and their growth represent one of the main directions in modern mechanics of solids. Such models are increasingly used to deal with complex biomedical problems. Prediction of in-stent restenosis for patients treated with coronary stents remains a highly challenging task. Using a finite element method, this paper presents a mechanistic approach to evaluate the development of in-stent restenosis in an artery following stent implantation. Hyperelastic models with damage, verified with experimental results, are used to describe the level of tissue damage in arterial layers and plaque caused by such intervention. A tissue-growth model, associated with vessel damage, is adopted to describe the growth behaviour of a media layer after stent implantation. Narrowing of lumen diameter with time is used to quantify the development of in-stent restenosis in the vessel after stenting. It is demonstrated that stent designs and materials strongly affect the stenting-induced damage in the media layer and the subsequent development of in-stent restenosis. The larger the artery expansion achieved during balloon inflation, the higher the damage introduced to the media layer, leading to an increased level of in-stent restenosis. In addition, the development of in-stent restenosis is directly correlated with the artery expansion during the stent deployment. The correlation is further used to predict the effect of a complex clinical procedure, such as stent overlapping, on the level of in-stent restenosis developed after percutaneous coronary intervention.

  相似文献   

2.

Background  

The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary artery might give insights in the understanding of the process of restenosis.  相似文献   

3.

Balloon pre-dilation is usually performed before implantation of a nitinol stent in a femoropopliteal artery in a case of severe blockage or calcified plaque. However, its effect on performance of the nitinol stent in a diseased femoropopliteal artery has not been studied yet. This study compares the outcomes of stenting with pre-dilation and without it by modelling the entire processes of stent deployment. Fatigue deformation of the implanted stent is also modelled under diastolic–systolic blood pressure, repetitive bending, torsion, axial compression and their combination. Reduced level of stress in the stent occurs after stenting with pre-dilation, but causing the increased damage in the media layer, i.e. the middle layer of the arterial wall. Generally, pre-dilation increases the risk of nitinol stent’s fatigue failure. Additionally, the development of in-stent restenosis is predicted based on the stenting-induced tissue damage in the media layer, and no severe mechanical irritation is induced to the media layer by pre-dilation, stent deployment or fatigue loading.

  相似文献   

4.
Cardiovascular stent design and vessel stresses: a finite element analysis   总被引:19,自引:0,他引:19  
Intravascular stents of various designs are currently in use to restore patency in atherosclerotic coronary arteries and it has been found that different stents have different in-stent restenosis rates. It has been hypothesized that the level of vascular injury caused to a vessel by a stent determines the level of restenosis. Computational studies may be used to investigate the mechanical behaviour of stents and to determine the biomechanical interaction between the stent and the artery in a stenting procedure. In this paper, we test the hypothesis that two different stent designs will provoke different levels of stress within an atherosclerotic artery and hence cause different levels of vascular injury. The stents analysed using the finite-element method were the S7 (Medtronic AVE) and the NIR (Boston Scientific) stent designs. An analysis of the arterial wall stresses in the stented arteries indicates that the modular S7 stent design causes lower stress to an atherosclerotic vessel with a localized stenotic lesion compared to the slotted tube NIR design. These results correlate with observed clinical restenosis rates, which have found higher restenosis rates in the NIR compared with the S7 stent design. Therefore, the testing methodology outlined here is proposed as a pre-clinical testing tool, which could be used to compare and contrast existing stent designs and to develop novel stent designs.  相似文献   

5.
The success of stents to restore blood flow in atherosclerotic peripheral arteries is low relative to coronary arteries. It has been shown that joint flexion induces a mechanical environment that makes stent placement in these arteries highly incompatible, and damage and destruction of stents has been recorded. However, the effect of this environment on the stresses in the arteries is unknown. It is hypothesised that the stresses induced in arteries as a result of this mechanical environment could be sufficient to explain the relatively low success rates. To investigate this hypothesis, a finite element model of the stent-artery interaction was developed. Following stent expansion, bending was simulated by applying a displacement boundary condition to the artery. It is found that high stresses occur at the proximal/distal ends of the stent. As high stress and vascular injury are hypothesised to cause restenosis, the results presented here suggest that the mechanical environment of peripheral arteries could be the predominant cause of high restenosis rates.  相似文献   

6.
One way to restore physiological blood flow to occluded arteries involves the deformation of plaque using an intravascular balloon and preventing elastic recoil using a stent. Angioplasty and stent implantation cause unphysiological loading of the arterial tissue, which may lead to tissue in-growth and reblockage; termed "restenosis." In this paper, a computational methodology for predicting the time-course of restenosis is presented. Stress-induced damage, computed using a remaining life approach, stimulates inflammation (production of matrix degrading factors and growth stimuli). This, in turn, induces a change in smooth muscle cell phenotype from contractile (as exists in the quiescent tissue) to synthetic (as exists in the growing tissue). In this paper, smooth muscle cell activity (migration, proliferation, and differentiation) is simulated in a lattice using a stochastic approach to model individual cell activity. The inflammation equations are examined under simplified loading cases. The mechanobiological parameters of the model were estimated by calibrating the model response to the results of a balloon angioplasty study in humans. The simulation method was then used to simulate restenosis in a two dimensional model of a stented artery. Cell activity predictions were similar to those observed during neointimal hyperplasia, culminating in the growth of restenosis. Similar to experiment, the amount of neointima produced increased with the degree of expansion of the stent, and this relationship was found to be highly dependant on the prescribed inflammatory response. It was found that the duration of inflammation affected the amount of restenosis produced, and that this effect was most pronounced with large stent expansions. In conclusion, the paper shows that the arterial tissue response to mechanical stimulation can be predicted using a stochastic cell modeling approach, and that the simulation captures features of restenosis development observed with real stents. The modeling approach is proposed for application in three dimensional models of cardiovascular stenting procedures.  相似文献   

7.
The purpose of the study was to assess the areas of balloon angioplasty (BAP) and stenting of lower extremity arteries and femoral, popliteal, mainly, in situ autovenous shunts, by using color duplex scanning (CDS) in the late period of a follow-up. Materials and methods. The CDS technique could diagnose 344 (64%) areas of BAP and stenting of lower extremity arteries and shunts. The echosemiotics of complications typical of a late period was determined. Based on the specified echosemiotics of late complications, the author detected 99 (28.8%) cases of hemodynamically significant complications: BAP and stenting area stenosis (n=25 (7.3%)); BAP area restenosis (reocciusion) (n=33 (9.6%)); stent restenosis (n=19 (5.5%), arterial stenosis proximal and distal to a stent (n=17 4.9%)), and stent breakage (n=5 (1.5%)). Hemodynamically insignificant complications were revealed in 90 (26.2%) cases: intimal dissection in 16 (4.7%) cases, BAP area restenosis in 35 (10%), stent restenosis in 15 (4.4%), and arterial stenosis proximal or distal to the stent and between the stents. In the late period following BAP and stenting aortoiliac patency was 87.50 + 3.18% during a mean follow-up o 27.58 + 1.50 months. In the late period, the patency of the superficial femoral artery (SFR) was 55.41 + 14.43% during a mean follow-up of 22.60 + 2.73 months, that of the popliteal artery (PA) was 67.34 + 15.98% during a mean follow-up of 43.08 + 5.81 months, that of shin arteries was 44.96 + 19.77% during a mean follow-up of 18.76 + 2.58 months, and that of shunts, was 40.89 + 18.47% during a mean follow-up of 23.32 + 2.29 months. Thus, changes caused by the progression of the underlying disease--atherosclerosis were found in the areas of BAP and stenting of lower extremity arteries and shunts. Stent breakage may be due to "metal deterioration" and the presence of a stent in the superficial femoral artery with greatest functional load on extremity movement and flexion. The blood flow spectrum mode recording a local hemodynamic shift with > 2.0-2.5-fold linear blood flow velocity increase in the complication area was leading in the operation of an ultrasound apparatuses in the differential diagnosis of hemodynamically significant and insignificant complications. The results of good late patency of the areas of BAP and stentming of SFR and PA may be accounted for by strict criteria for selecting patients for endovascular surgery, by taking into account the indications for and contraindications to TASC (2001). In our study, 20 endovascular reinterventions (repeated balloon angioplasty, additional stenting stent balloon angioplasty) in complicated areas were performed, which maintained and prolonged the function of segments. The detection of hemodynamically insignificant complications revealed patients who need further meticulous follow-up ultrasound studies.  相似文献   

8.

Percutaneous coronary intervention (PCI) has become the primary treatment for patients with coronary heart disease because of its minimally invasive nature and high efficiency. Anatomical studies have shown that most coronary vessels gradually shrink, and the vessels gradually become thinner from the proximal to the distal end. In this paper, the effects of different stent expansion methods on the mechanical and hemodynamic behaviors of coronary vessels and stents were studied. To perform a structural-mechanical analysis of stent implantation, the coronary vessels with branching vessels and the coronary vessels with large bending curvature are selected. The two characteristic structures are implanted in equal diameter expansion mode and conical expansion mode, and the stress and mechanical behaviors of the coronary vessels and stents are analyzed. The results of the structural-mechanical analysis showed that the mechanical behaviors and fatigue performance of the cobalt-chromium alloy stent were good, and the different expansion modes of the stent had little effect on the fatigue performance of the stent. However, the equal diameter expansion mode increased distal coronary artery stress and the risk of vascular injury. The computational fluid dynamics analysis results showed that different stent expansion methods had varied effects on coronary vessel hemodynamics and that the wall shear stress distribution of conical stent expansion is more uniform compared with equal diameter expansion. Additionally, the vortex phenomenon is not apparent, the blood flow velocity is slightly increased, the hydrodynamic environment is more reasonable, and the risk of coronary artery injury is reduced.

  相似文献   

9.
Wu W  Wang WQ  Yang DZ  Qi M 《Journal of biomechanics》2007,40(11):2580-2585
Coronary restenosis after angioplasty has been reduced by stenting procedure, but in-stent restenosis (ISR) has not been eliminated yet, especially in tortuous vessels. In this paper, we proposed a finite element method (FEM) to study the expansion of a stent in a curved vessel (the CV model) and their interactions. A model of the same stent in a straight vessel (the SV model) was also studied and mechanical parameters of both models were researched and compared, including final lumen area, tissue prolapse between stent struts and stress distribution. Results show that in the CV model, the vessel was straightened by stenting and a hinge effect can be observed at extremes of the stent. The maximum tissue prolapse of the CV model was more severe (0.079 mm) than the SV model (0.048 mm); and the minimum lumen area of the CV was decreased (6.10 mm(2)), compared to that of the SV model (6.28 mm(2)). Tissue stresses of the highest level were concentrated in the inner curvature of the CV model. The simulations offered some explanations for the clinical results of ISR in curved vessels and gave design suggestions of the stent and balloon for tortuous vessels. This FEM provides a tool to study mechanisms of stents in curved vessels and can improve new stent designs especially for tortuous vessels.  相似文献   

10.
Carotid artery stenting (CAS) has emerged as a minimally invasive alternative to endarterectomy but its use in clinical treatment is limited due to the post-stenting complications. Haemodynamic actors, related to blood flow in the stented vessel, have been suggested to play a role in the endothelium response to stenting, including adverse reactions such as in-stent restenosis and late thrombosis. Accessing the flow-related shear forces acting on the endothelium in vivo requires space and time resolutions which are currently not achievable with non-invasive clinical imaging techniques but can be obtained from image-based computational analysis. In this study, we present a framework for accurate determination of the wall shear stress (WSS) in a mildly stenosed carotid artery after the implantation of a stent, resembling the commercially available Acculink (Abbott Laboratories, Abbott Park, Illinois, USA). Starting from angiographic CT images of the vessel lumen and a micro-CT scan of the stent, a finite element analysis is carried out in order to deploy the stent in the vessel, reproducing CAS in silico. Then, based on the post-stenting anatomy, the vessel is perfused using a set of boundary conditions: total pressure is applied at the inlet, and impedances that are assumed to be insensitive to the presence of the stent are imposed at the outlets. Evaluation of the CAS outcome from a geometrical and haemodynamic perspective shows the presence of atheroprone regions (low time-average WSS, high relative residence time) colocalised with stent malapposition and stent strut interconnections. Stent struts remain unapposed in the ostium of the external carotid artery disturbing the flow and generating abnormal shear forces, which could trigger thromboembolic events.  相似文献   

11.
Clinical trials have reported different restenosis rates for various stent designs. It is speculated that stent-induced strain concentrations on the arterial wall lead to tissue injury, which initiates restenosis. This hypothesis needs further investigations including better quantifications of non-uniform strain distribution on the artery following stent implantation. A non-contact surface strain measurement method for the stented artery is presented in this work. ARAMIS stereo optical surface strain measurement system uses two optical high speed cameras to capture the motion of each reference point, and resolve three dimensional strains over the deforming surface. As a mesh stent is deployed into a latex vessel with a random contrasting pattern sprayed or drawn on its outer surface, the surface strain is recorded at every instant of the deformation. The calculated strain distributions can then be used to understand the local lesion response, validate the computational models, and formulate hypotheses for further in vivo study.  相似文献   

12.
Despite technical and mechanical improvement in coronary stents the incidence of restenosis caused by in-stent neointimal hyperplasia remains high. Oral administration of numerous pharmacological agents has failed to reduce restenosis after coronary stenting in humans, possibly owing to insufficient local drug concentration. Therefore, drug-eluting stents were developed as a vehicle for local drug administration. The authors developed a new drug-eluting polymer stent that is made of poly-l-lactic acid polymer mixed with tranilast, an anti-allergic drug that inhibits the migration and proliferation of vascular smooth muscle cells induced by platelet-derived growth factor and transforming growth factor->1. Polymer stents might be superior to polymer-coated metallic stents as local drug delivery stents in terms of biodegradation and the amount of loaded drug. Drug-mixed polymer stents can be loaded with a larger amount of drug than can drug-coated metallic stents because the polymer stent struts can contain the drug. Clinical application is required to assess the safety and efficacy of drug-eluting polymer stents against stent restenosis.  相似文献   

13.
To clarify the role of vascular endothelial growth factor (VEGF) in the process of restenosis, a Palmaz-Schatz stent was implanted in the left anterior descending coronary artery of male pigs at 2 weeks after balloon injury (balloon/artery ratio 1.2:1). The animals were euthanized at 1, 2, and 4 weeks after stenting, and western blot and immunohistochemical analysis were performed using VEGF, fms-like tyrosine kinase (flt)-1, and platelet-derived growth factor (PDGF) antibodies. The expressions of VEGF and flt-1 protein in the neointima were observed as early as 1 week after stenting and remained for up to 4 weeks, while re-endothelialization was complete at 2 weeks. These protein expressions were demonstrated in proliferated smooth muscle cells throughout the entire period after stenting and, in addition, they were observed in the macrophages and endothelial cells of microvessels around stent struts at 4 weeks. The expression pattern of VEGF corresponded with that of PDGF, a growth factor well-known to induce neointimal proliferation. The cell proliferative activity, measured by the proliferating cell nuclear antigen index, around the struts remained high until 4 weeks after stenting, while that in the other areas declined at 4 weeks. These results suggest that VEGF is involved in the process of restenosis not only through its angiogenic properties and induction of monocyte chemotaxis, but also by a synergistic effect with PDGF.  相似文献   

14.
Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.  相似文献   

15.
The paper assesses the immediate and long-term results of direct stenting (without the stage of predilation) and compares with the outcomes of conventional stent implantation. A prospective study included 183 patients. All the patients were divided into two groups according to the procedure of stent implantation. In 85 (46.7%) patients, the stent was implanted without preliminary predilation of stenosis (direct stenting). These patients formed Group 1. Group 2 comprised 97 (53.3%) patients in whom the stent was placed by using the routine procedure. All the patients enrolled into the study had types A, B1, and B2 stenoses according to the ACC/AHA classification and received the conventional antiaggregatory and anticoagulant therapy. The technical success of direct stenting was 97.7%. There were no cases of stent dislocation and loss during direct stenting or expansion of a balloon and stent. Analyzing the immediate results in all the patients of the both groups showed a positive angiographic success. Thus, a primary angiographic and clinical success of direct stenting was achieved in all (100%) patients. Recurrent angina pectoris with restenosis was observed in 8 (9.4%) patients in Group 1 and in 21 (21.6%) in Group 2 (p < 0.05). Direct stenting significantly differs from the routine stent implantation in all procedure parameters. Thus, direct stenting in patients with uncomplicated stenoses is a safe and feasible procedure.  相似文献   

16.

Introduction

Coronary stenting has previously been considered to be less feasible in children under 12 years old due to the limitation of vascular access. We report the case of a six-year-old boy who successfully underwent stent implantation for his totally occluded right coronary artery.

Case presentation

A Taiwanese boy aged six years and nine months old was found to have giant aneurysms after an acute episode of Kawasaki disease. An angiography revealed that his middle right coronary artery was totally occluded. A 0.014-inch guidewire was advanced to cross the totally occluded site. After pre-dilating the middle portion of his right coronary artery with a 1.5 mm balloon, stenting of his right coronary artery was accomplished using a 2.5 × 28 mm and a 2.5 × 18 mm bare metal stent. A final angiography demonstrated no residual stenosis or dissection.

Conclusion

Coronary stenting could be a therapeutic option for children as young as six years old. Close follow-up is mandatory because the long-term outcome is still unclear, especially in a small child.  相似文献   

17.
BACKGROUND: Coronary artery stenting is particularly useful during percutaneous coronary intervention for long lesions previously associated with a low procedural success rate and a high complication rate of dissection and occlusion. Current treatment options include implantation of a single long stent, multiple contiguous stents, or 'spot' stenting. However, multiple stent implantation may result in sections of overlapping stent or gaps of unstented segments and is an independent predictor of restenosis. The early and intermediate clinical outcome of single and multiple long stent (>/= 30 mm) implantation is not established. METHODS AND RESULTS: The authors retrospectively identified 123 consecutive patients who had undergone stenting using one or more long coronary stents. Baseline clinical data, procedural outcomes and completed clinical follow-up to 52 weeks were obtained by case-note review. The majority (69%) required intervention for stable coronary disease. Seventy-seven per cent of lesions were either type B2 or C and only 2% were in saphenous vein grafts. The procedural success rate was 94%. A total of 15 major events occurred in 13 patients (11%). Ten acute events occurred and five events were during the follow-up period from 30 days to 52 weeks. Two patients died, one from uncontrolled bleeding secondary to the use of antithrombotic agents and one at four weeks due to sudden death. One patient had a postprocedural infarct. Two patients required in-hospital repeat revascularization for acute vessel closure and eight required revascularization during follow-up (three cases of occlusion/thrombosis and five cases of restenosis). CONCLUSIONS: The use of long coronary stents (>/= 30 mm) for the treatment of long diffuse native vessel disease, saphenous vein graft disease and long coronary dissections is associated with a reasonable procedural success rate and acceptable early and intermediate-term clinical outcomes.  相似文献   

18.
Two different stent configurations (i.e. the well known Palmaz–Schatz (PS) and a new stent configuration) are mechanically investigated. A finite element model was used to study the two geometries under combining loads and a computational fluid dynamic model based on fluid structure interaction was developed investigating the plaque and the artery wall reactions in a stented arterial segment. These models determine the stress and displacement fields of the two stents under internal pressure conditions. Results suggested that stent designs cause alterations in vascular anatomy that adversely affect arterial stress distributions within the wall, which have impact in the vessel responses such as the restenosis. The hemodynamic analysis shows the use of new stent geometry suggests better biofluid mechanical response such as the deformation and the progressive amount of plaque growth.  相似文献   

19.

Endovascular therapy in patients suffering from peripheral arterial disease shows high rates of restenosis. The poor clinical outcomes are commonly explained by the demanding mechanical environment due to leg movements, but the mechanisms responsible for restenosis remain unknown. In this study, we hypothesized that restenosis following revascularization is associated with hemodynamical markers derived from blood flow during leg flexion. Therefore, we performed personalized computational fluid dynamics (CFD) analyses of 20 patients, who underwent routine endovascular femoro-popliteal interventions. The CFD analyses were conducted using 3D models of the arterial geometry in straight and flexed positions, which were reconstructed from 2D angiographic images. Based on restenosis rates reported at 6-month follow-up, logistic regression analyses were performed to predict restenosis from hemodynamical parameters. Results showed that severe arterial deformations, such as kinking, induced by leg flexion in stented arteries led to adverse hemodynamic conditions that may trigger restenosis. A logistic regression analysis based solely on hemodynamical markers had an accuracy of 75%, which showed that flow parameters are sufficient to predict restenosis (p = 0.031). However, better predictions were achieved by adding the treatment method in the model. This suggests that a more accurate image acquisition technique is required to capture the localized modifications of blood flow following intervention, especially around the stented artery. This approach, based on the immediate postoperative configuration of the artery, has the potential to identify patients at increased risk of restenosis. Based on this information, clinicians could take preventive measures and more closely follow these patients to avoid complications.

  相似文献   

20.
Since their first introduction, stents have revolutionised the treatment of atherosclerosis; however, the development of in-stent restenosis still remains the Achilles' heel of stent deployment procedures. Computational modelling can be used as a means to model the biological response of arteries to different stent designs using mechanobiological models, whereby the mechanical environment may be used to dictate the growth and remodelling of vascular cells. Changes occurring within the arterial wall due to stent-induced mechanical injury, specifically changes within the extracellular matrix, have been postulated to be a major cause of activation of vascular smooth muscle cells and the subsequent development of in-stent restenosis. In this study, a mechanistic multi-scale mechanobiological model of in-stent restenosis using finite element models and agent-based modelling is presented, which allows quantitative evaluation of the collagen matrix turnover following stent-induced arterial injury and the subsequent development of in-stent restenosis. The model is specifically used to study the influence of stent deployment diameter and stent strut thickness on the level of in-stent restenosis. The model demonstrates that there exists a direct correlation between the stent deployment diameter and the level of in-stent restenosis. In addition, investigating the influence of stent strut thickness using the mechanobiological model reveals that thicker strut stents induce a higher level of in-stent restenosis due to a higher extent of arterial injury. The presented mechanobiological modelling framework provides a robust platform for testing hypotheses on the mechanisms underlying the development of in-stent restenosis and lends itself for use as a tool for optimisation of the mechanical parameters involved in stent design.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号