共查询到20条相似文献,搜索用时 15 毫秒
1.
T. Oktenoglu A. Kiapour A.F. Ozer I. Lazoglu T. Kaner 《Computer methods in biomechanics and biomedical engineering》2013,16(11):1252-1261
Pedicle screw-based dynamic constructs either benefit from a dynamic (flexible) interconnecting rod or a dynamic (hinged) screw. Both types of systems have been reported in the literature. However, reports where the dynamic system is composed of two dynamic components, i.e. a dynamic (hinged) screw and a dynamic rod, are sparse. In this study, the biomechanical characteristics of a novel pedicle screw-based dynamic stabilisation system were investigated and compared with equivalent rigid and semi-rigid systems using in vitro testing and finite element modelling analysis. All stabilisation systems restored stability after decompression. A significant decrease in the range of motion was observed for the rigid system in all loadings. In the semi-rigid construct the range of motion was significantly less than the intact in extension, lateral bending and axial rotation loadings. There were no significant differences in motion between the intact spine and the spine treated with the dynamic system (P>0.05). The peak stress in screws was decreased when the stabilisation construct was equipped with dynamic rod and/or dynamic screws. 相似文献
2.
Fabio Galbusera Hendrik Schmidt Cornelia Neidlinger-Wilke Hans-Joachim Wilke 《Computer methods in biomechanics and biomedical engineering》2013,16(8):729-739
Intervertebral disc degeneration involves changes in the spinal anatomical structures. The mechanical relevance of the following changes was investigated: disc height, endplate sclerosis, disc water content, permeability and depressurisation. A poroelastic nonlinear finite element model of the L4–L5 human spine segments was employed. Loads represented a daily cycle (500 N compression combined with flexion–extension motion for 16 h followed by 200 N compression for 8 h). In non-degenerative conditions, the model predicted a diurnal axial displacement of 1.32 mm and a peak intradiscal pressure of 0.47 MPa. Axial displacement, facet force and range of motion in flexion–extension are decreased by decreasing disc height. By decreasing the initial water content, axial displacement, facet force and fluid loss were all reduced. Endplate sclerosis did not have a significant influence on the calculated results. Depressurisation determined an increase of the disc effective stress, possibly inducing failure. Degenerative instability was not calculated in any simulations. 相似文献
3.
Shaobai Wang Won Man Park Hemanth R. Gadikota Jun Miao Yoon Hyuk Kim Kirkham B. Wood 《Computer methods in biomechanics and biomedical engineering》2013,16(12):1278-1286
Evaluation of the loads on lumbar intervertebral discs (IVD) is critically important since it is closely related to spine biomechanics, pathology and prosthesis design. Non-invasive estimation of the loads in the discs remains a challenge. In this study, we proposed a new technique to estimate in vivo loads in the IVD using a subject-specific finite element (FE) model of the disc and the kinematics of the disc endplates as input boundary conditions. The technique was validated by comparing the forces and moments in the discs calculated from the FE analyses to the in vitro experiment measurements of three corresponding lumbar discs. The results showed that the forces and moments could be estimated within an average error of 20%. Therefore, this technique can be a promising tool for non-invasive estimation of the loads in the discs and may be extended to be used on living subjects. 相似文献
4.
Mitchell S. Hortin 《Computer methods in biomechanics and biomedical engineering》2016,19(14):1505-1518
Data has been published that quantifies the nonlinear, anisotropic material behaviour and pre-strain behaviour of the anterior longitudinal, supraspinous (SSL), and interspinous ligaments of the human lumbar spine. Additionally, data has been published on localized material properties of the SSL. These results have been incrementally incorporated into a previously validated finite element model of the human lumbar spine. Results suggest that the effects of increased ligament model fidelity on bone strain energy were moderate and the effects on disc pressure were slight, and do not justify a change in modelling strategy for most clinical applications. There were significant effects on the ligament stresses of the ligaments that were directly modified, suggesting that these phenomena should be included in FE models where ligament stresses are the desired metric. 相似文献
5.
Zheng-Cheng Zhong Chinghua Hung Hung-Ming Lin Ying-Hui Wang Chang-Hung Huang 《Computer methods in biomechanics and biomedical engineering》2013,16(9):943-953
In a finite element (FE) analysis of the lumbar spine, different preload application methods that are used in biomechanical studies may yield diverging results. To investigate how the biomechanical behaviour of a spinal implant is affected by the method of applying the preload, hybrid-controlled FE analysis was used to evaluate the biomechanical behaviour of the lumbar spine under different preload application methods. The FE models of anterior lumbar interbody fusion (ALIF) and artificial disc replacement (ADR) were tested under three different loading conditions: a 150 N pressure preload (PP) and 150 and 400 N follower loads (FLs). This study analysed the resulting range of motion (ROM), facet contact force (FCF), inlay contact pressure (ICP) and stress distribution of adjacent discs. The FE results indicated that the ROM of both surgical constructs was related to the preload application method and magnitude; differences in the ROM were within 7% for the ALIF model and 32% for the ADR model. Following the application of the FL and after increasing the FL magnitude, the FCF of the ADR model gradually increased, reaching 45% at the implanted level in torsion. The maximum ICP gradually decreased by 34.1% in torsion and 28.4% in lateral bending. This study concluded that the preload magnitude and application method affect the biomechanical behaviour of the lumbar spine. For the ADR, remarkable alteration was observed while increasing the FL magnitude, particularly in the ROM, FCF and ICP. However, for the ALIF, PP and FL methods had no remarkable alteration in terms of ROM and adjacent disc stress. 相似文献
6.
Francisco Sahli Jorge Cuellar Alfonso Pérez Aaron J. Fields Mauricio Campos 《Computer methods in biomechanics and biomedical engineering》2013,16(8):890-899
Spinal metastatic disease could lead to catastrophic consequences for the patient. However, the structural parameters that explain the weakening of vertebrae affected by tumours are not fully understood. In this study, we developed a specimen-specific finite element model to predict the strength of the porcine vertebra with simulated tumours and used it to find the structural parameters determining the strength. We validated our model with mechanical testing and then we analysed the compressive strength of intact vertebrae and seven defects with different size and shape. The results showed that the minimum bone mineral mass of the cross section and areal defect fraction were the best predictors of the normalized strength. We also found that areal parameters appeared to be better predictors than the volumetric ones. In conclusion, reduction in bone strength for vertebrae weakened by metastatic tumours is mostly associated with decrease in the mechanical properties of the cross section. 相似文献
7.
Arin M. Ellingson Miranda N. Shaw Hugo Giambini Kai-Nan An 《Computer methods in biomechanics and biomedical engineering》2016,19(9):1009-1018
Understanding spinal kinematics is essential for distinguishing between pathological conditions of spine disorders, which ultimately lead to low back pain. It is of high importance to understand how changes in mechanical properties affect the response of the lumbar spine, specifically in an effort to differentiate those associated with disc degeneration from ligamentous changes, allowing for more precise treatment strategies. To do this, the goals of this study were twofold: (1) develop and validate a finite element (FE) model of the lumbar spine and (2) systematically alter the properties of the intervertebral disc and ligaments to define respective roles in functional mechanics. A three-dimensional non-linear FE model of the lumbar spine (L3-sacrum) was developed and validated for pure moment bending. Disc degeneration and sequential ligament failure were modelled. Intersegmental range of motion (ROM) and bending stiffness were measured. The prediction of the FE model to moment loading in all three planes of bending showed very good agreement, where global and intersegmental ROM and bending stiffness of the model fell within one standard deviation of the in vitro results. Degeneration decreased ROM for all directions. Stiffness increased for all directions except axial rotation, where it initially increased then decreased for moderate and severe degeneration, respectively. Incremental ligament failure produced increased ROM and decreased stiffness. This effect was much more pronounced for all directions except lateral bending, which is minimally impacted by ligaments. These results indicate that lateral bending may be more apt to detect the subtle changes associated with degeneration, without being masked by associated changes of surrounding stabilizing structures. 相似文献
8.
S. Kallhovd S. T. Wall 《Computer methods in biomechanics and biomedical engineering》2019,22(6):664-675
Cardiac stress (load) and strain (stretch) are widely studied indicators of cardiac function and outcome, but are difficult or impossible to directly measure in relation to the cardiac microstructure. An alternative approach is to estimate these states using computer methods and image-based measurements, but this still requires knowledge of the tissue material properties and the unloaded state, both of which are difficult to determine. In this work, we tested the sensitivity of these two interdependent unknowns (reference geometry and material parameters) on stress and strain calculations in cardiac tissue. Our study used a finite element model of the human ventricle, with a hyperelastic passive material model, and was driven by a cell model mediated active contraction. We evaluated 21 different published parameter sets for the five parameters of the passive material model, and for each set we optimised the corresponding unloaded geometry and contractility parameter to model a single pressure-volume loop. The resulting mechanics were compared, and calculated systolic stresses were largely insensitive to the chosen parameter set when an unloading algorithm was used. Meanwhile, material strain calculations varied substantially depending on the choice of material parameters. These results indicate that determining the correct material and unloaded configuration may be highly important to understand strain driven processes, but less so for calculating stress estimates. 相似文献
9.
Sean M. Finley Darrel S. Brodke Nicholas T. Spina Christine A. DeDen 《Computer methods in biomechanics and biomedical engineering》2018,21(6):444-452
Finite element analysis has proven to be a viable method for assessing many structure-function relationships in the human lumbar spine. Several validated models of the spine have been published, but they typically rely on commercial packages and are difficult to share between labs. The goal of this study is to present the development of the first open-access models of the human lumbar spine in FEBio. This modeling framework currently targets three deficient areas in the field of lumbar spine modeling: 1) open-access models, 2) accessibility for multiple meshing schemes, and 3) options to include advanced hyperelastic and biphasic constitutive models. 相似文献
10.
Mengchen Xu Amy L. Lerner Paul D. Funkenbusch Ashutosh Richhariya 《Computer methods in biomechanics and biomedical engineering》2018,21(3):287-296
The optical performance of the human cornea under intraocular pressure (IOP) is the result of complex material properties and their interactions. The measurement of the numerous material parameters that define this material behavior may be key in the refinement of patient-specific models. The goal of this study was to investigate the relative contribution of these parameters to the biomechanical and optical responses of human cornea predicted by a widely accepted anisotropic hyperelastic finite element model, with regional variations in the alignment of fibers. Design of experiments methods were used to quantify the relative importance of material properties including matrix stiffness, fiber stiffness, fiber nonlinearity and fiber dispersion under physiological IOP. Our sensitivity results showed that corneal apical displacement was influenced nearly evenly by matrix stiffness, fiber stiffness and nonlinearity. However, the variations in corneal optical aberrations (refractive power and spherical aberration) were primarily dependent on the value of the matrix stiffness. The optical aberrations predicted by variations in this material parameter were sufficiently large to predict clinically important changes in retinal image quality. Therefore, well-characterized individual variations in matrix stiffness could be critical in cornea modeling in order to reliably predict optical behavior under different IOPs or after corneal surgery. 相似文献
11.
Previous studies have compared the effects of different interbody fusion approaches on biomechanical responses of the lumbar spine to static loadings. However, very few have dealt with the whole body vibration (WBV) condition that is typically present in vehicles. This study was designed to determine the biomechanical differences among anterior, posterior and transforaminal lumbar interbody fusion (ALIF, PLIF and TLIF) under vertical WBV. A previously developed and validated finite element (FE) model of the intact L1–sacrum human lumbar spine was modified to simulate ALIF, PLIF and TLIF with bilateral pedicle screw fixation at L4–L5. Comparative studies on dynamic responses to the axial cyclic loading in these developed models were conducted. The results showed that at the fused L4–L5 level, dynamic responses of the von-Mises stress in L4 inferior and L5 superior endplates for the ALIF, PLIF and TLIF models were increased compared with the intact model. The endplate stresses in the TLIF model were lower than in the ALIF and PLIF models, but the TLIF generated greater stresses in the screws and rods compared with the ALIF and PLIF. At other levels, a decrease in dynamic responses of the disc bulge, annulus stress and intradiscal pressure was observed in all the fusion models compared with the intact one, but there was no obvious difference in these dynamic responses among the ALIF, PLIF and TLIF models. These findings might be useful in understanding vibration characteristics of the whole lumbar spine after different types of fusion surgery. 相似文献
12.
Masni-Azian Masao Tanaka 《Computer methods in biomechanics and biomedical engineering》2017,20(10):1066-1076
In the biomechanics field, material parameters calibration is significant for finite element (FE) model to ensure a legit estimation of biomechanical response. Determining an appropriate combination of calibration factors is challenging as each constitutive component responds differently. This study proposes a statistical factorial analysis approach using L16(45) orthogonal array to evaluate material nonlinearity and applicable calibration factor of the intervertebral disc FE model in pure moment. The calibrated model exhibits improved agreement to the experimental findings for all directions. Appropriate combination of calibration parameter reduces the estimation gap to the experimental findings, ensuring agreeable biomechanical responses. 相似文献
13.
Zhenjun Zhang Guy R. Fogel Zhenhua Liao Yitao Sun 《Computer methods in biomechanics and biomedical engineering》2018,21(3):247-254
Inappropriate lordotic angle of lumbar fusion cage could be associated with cage damage or subsidence. The biomechanical influence of cage lordotic angle on lumbar spine has not been fully investigated. Four surgical finite element models were constructed by inserting cages with various lordotic angles at L3-L4 disc space. The four motion modes were simulated. The range of motion (ROM) decreased with increased lordotic angle of cage in flexion, extension, and rotation, whereas it was not substantially changed in bending. The maximum stress in cage decreased with increased lordotic angle of cage in all motion modes. The maximum stress in endplate at surgical level increased with increased lordotic angle of cage in flexion and rotation, whereas it was not substantially changed in extension and bending. The facet joint force (FJF) was much smaller than that for the intact conditions in extension, bending, and rotation, while it was not substantially changed in flexion. In conclusion, the ROM, stresses in the cage and endplate at surgical level are sensitive to the lordotic angle of cage. The increased cage lordotic angle may provide better stability and reduce the risk of cage damage, whereas it may increase the risk of subsidence in flexion and rotation. 相似文献
14.
Ugur M. Ayturk 《Computer methods in biomechanics and biomedical engineering》2013,16(8):695-705
The primary objective of this study was to generate a finite element model of the human lumbar spine (L1–L5), verify mesh convergence for each tissue constituent and perform an extensive validation using both kinematic/kinetic and stress/strain data. Mesh refinement was accomplished via convergence of strain energy density (SED) predictions for each spinal tissue. The converged model was validated based on range of motion, intradiscal pressure, facet force transmission, anterolateral cortical bone strain and anterior longitudinal ligament deformation predictions. Changes in mesh resolution had the biggest impact on SED predictions under axial rotation loading. Nonlinearity of the moment-rotation curves was accurately simulated and the model predictions on the aforementioned parameters were in good agreement with experimental data. The validated and converged model will be utilised to study the effects of degeneration on the lumbar spine biomechanics, as well as to investigate the mechanical underpinning of the contemporary treatment strategies. 相似文献
15.
Trung Dung Nguyen Adekunle Oloyede 《Computer methods in biomechanics and biomedical engineering》2016,19(2):126-136
The aim of this paper is to use a poroviscohyperelastic (PVHE) model, which is developed based on the porohyperelastic (PHE) model to explore the mechanical deformation properties of single chondrocytes. Both creep and relaxation responses are investigated by using finite element analysis models of micropipette aspiration and atomic force microscopy experiments, respectively. The newly developed PVHE model is compared thoroughly with the standard neo-Hookean solid and PHE models. It has been found that the PVHE can accurately capture both creep and stress relaxation behaviors of chondrocytes better than other two models. Hence, the PVHE is a promising model to investigate mechanical properties of single chondrocytes. 相似文献
16.
Juying Huang Huagang Yan Fengzeng Jian Xingwen Wang 《Computer methods in biomechanics and biomedical engineering》2013,16(14):1516-1524
Nucleus replacement was deemed to have therapeutic potential for patients with intervertebral disc herniation. However, whether a patient would benefit from nucleus replacement is technically unclear. This study aimed to investigate the influence of nucleus pulposus (NP) removal on the biomechanical behavior of a lumbar motion segment and to further explore a computational method of biomechanical characteristics of NP removal, which can evaluate the mechanical stability of pulposus replacement. We, respectively, reconstructed three types of models for a mildly herniated disc and three types of models for a severely herniated disc based on a L4–L5 segment finite element model with computed tomography image data from a healthy adult. First, the NP was removed from the herniated disc models, and the biomechanical behavior of NP removal was simulated. Second, the NP cavities were filled with an experimental material (Poisson's ratio = 0.3; elastic modulus = 3 MPa), and the biomechanical behavior of pulposus replacement was simulated. The simulations were carried out under the five loadings of axial compression, flexion, lateral bending, extension, and axial rotation. The changes of the four biomechanical characteristics, i.e. the rotation degree, the maximum stress in the annulus fibrosus (AF), joint facet contact forces, and the maximum disc deformation, were computed for all models. Experimental results showed that the rotation range, the maximum AF stress, and joint facet contact forces increased, and the maximum disc deformation decreased after NP removal, while they changed in the opposite way after the nucleus cavities were filled with the experimental material. 相似文献
17.
18.
Cheng-Chan Lo Kai-Jow Tsai Shih-Hao Chen Zheng-Cheng Zhong 《Computer methods in biomechanics and biomedical engineering》2013,16(11):969-978
The Coflex device may provide stability to the surgical segment in extension but does not restore stability in other motion. Recently, a modified version called the Coflex rivet has been developed. The effects of Coflex and Coflex rivet implantation on the adjacent segments are still not clear; therefore, the purpose of this study was to investigate the biomechanical differences between Coflex and Coflex rivet implantation by using finite element analyses. The results show that the Coflex implantation can provide stability in extension, lateral bending, and axial rotation at the surgical segment, and it had no influence at adjacent segments except for extension. The Coflex rivet implantation can provide stability in all motions and reduce disc annulus stress at the surgical segment. Therefore, the higher range of motion and stress induced by the Coflex rivet at both adjacent discs may result in adjacent segment degeneration in flexion and extension. 相似文献
19.
B. Kathirgamanathan P. Silva J. Fernandez 《Computer methods in biomechanics and biomedical engineering》2019,22(1):47-54
Obesity causes increased loading on the foot which can damage the soft tissue and bone ultimately leading to foot problems. Experimental and computational methods were used to analyse the chain of biomechanical changes in the lower limb due to obesity. The experimental study shows some changes in foot posture and gait where obese subjects were more likely to have pronated feet, smaller joint angles in the sagittal and frontal planes, smaller cadence, and smaller stride length. Anatomically correct finite element models generated on obese subjects showed increased and altered internal and plantar stress. Altered foot posture was identified as a key indicator of increased internal stress indicating the importance of foot posture correction. 相似文献