相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
2.
This work presents experiments and modelling aimed at characterising the passive mechanical behaviour of the human thoracic descending aorta. To this end, uniaxial tension and pressurisation tests on healthy samples corresponding to newborn, young and adult arteries are performed. Then, the tensile measurements are used to calibrate the material parameters of the Holzapfel constitutive model. This model is found to adequately adjust the material behaviour in a wide deformation range; in particular, it captures the progressive stiffness increase and the anisotropy due to the stretching of the collagen fibres. Finally, the assessment of these material parameters in the modelling of the pressurisation test is addressed. The implication of this study is the possibility to predict the mechanical response of the human thoracic descending aorta under generalised loading states like those that can occur in physiological conditions and/or in medical device applications.  相似文献   

3.
In this work we examined the determination of soft tissue parameters via tissue aspiration experiments and inverse finite element characterisation. An aspiration tube was put against the target tissue. The deformation of the tissue inside the tube caused by weak suction was tracked with a video based system. A strain energy function was employed to model the elastic behaviour of soft tissue and viscoelasticity was accounted for by means of a quasi-linear viscoelastic formulation. Friction between the aspiration tube and the aspirated tissue was included in the model. Based on the assumed material model, an optimal set of material parameters was found, in order to best fit the experimental data obtained from ex-vivo experiments on pig kidney cortex. The inverse method resulted in robust determination of the unknown material parameters.  相似文献   

4.
The characterization of the bileaflet mechanical heart valves (BMHVs) hinge microflow fields is a crucial step in heart valve engineering. Earlier in vitro studies of BMHV hinge flow at the aorta position in idealized straight pipes have shown that the aortic sinus shapes and sizes may have a direct impact on hinge microflow fields. In this paper, we used a numerical study to look at how different aortic sinus shapes, the downstream aortic arch geometry, and the location of the hinge recess can influence the flow fields in the hinge regions. Two geometric models for sinus were investigated: a simplified axisymmetric sinus and an idealized three-sinus aortic root model, with two different downstream geometries: a straight pipe and a simplified curved aortic arch. The flow fields of a 29-mm St Jude Medical BMHV with its four hinges were investigated. The simulations were performed throughout the entire cardiac cycle. At peak systole, recirculating flows were observed in curved downsteam aortic arch unlike in straight downstream pipe. Highly complex three-dimensional leakage flow through the hinge gap was observed in the simulation results during early diastole with the highest velocity at 4.7 m/s, whose intensity decreased toward late diastole. Also, elevated wall shear stresses were observed in the ventricular regions of the hinge recess with the highest recorded at 1.65 kPa. Different flow patterns were observed between the hinge regions in straight pipe and curved aortic arch models. We compared the four hinge regions at peak systole in an aortic arch downstream model and found that each individual hinge did not vary much in terms of the leakage flow rate through the valves.  相似文献   

5.
To prevent traumas to abdominal organs, the selection of efficient safety devices should be based on a detailed knowledge of injury mechanisms and related injury criteria. In this sense, finite element (FE) simulation coupled with experiment could be a valuable tool to provide a better understanding of the behaviour of internal organs under crash conditions. This work proposes a methodology based on inverse analysis which combines exploration process optimisation and robustness study to obtain mechanical behaviour of the complex structure of the liver through FE simulation. The liver characterisation was based on Mooney-Rivlin hyperelastic behaviour law considering whole liver structure under uniform quasi-static compression. With the global method used, the model fits experimental data. The variability induced by modelling parameters is quantified within a reasonable time.  相似文献   

6.
To prevent traumas to abdominal organs, the selection of efficient safety devices should be based on a detailed knowledge of injury mechanisms and related injury criteria. In this sense, finite element (FE) simulation coupled with experiment could be a valuable tool to provide a better understanding of the behaviour of internal organs under crash conditions. This work proposes a methodology based on inverse analysis which combines exploration process optimisation and robustness study to obtain mechanical behaviour of the complex structure of the liver through FE simulation. The liver characterisation was based on Mooney–Rivlin hyperelastic behaviour law considering whole liver structure under uniform quasi-static compression. With the global method used, the model fits experimental data. The variability induced by modelling parameters is quantified within a reasonable time.  相似文献   

7.
The possibility of curling hair is attributed to the fact that the mechanical properties of hair fibres depend on time, temperature and humidity. In this study the dependence of the viscoelastic behaviour of human hair fibres on humidity is characterised in a bending deformation. An experimental set-up was used to perform bending relaxation measurements at different humidities. The relaxation data were fitted using a so-called "stretched exponential equation". The humidity dependence was incorporated by applying time-humidity superposition. Also, the influence of humidity on the initial E-modulus was found. The influence of humidity on the behaviour of human hair fibres could be modelled by using a general characterisation of the behaviour of human hair fibres.The general characterisation is used to predict the recovery in a human hair fibre after curling. The predicted recovery appeared to agree reasonably well with experimentally determined values.  相似文献   

8.
This work presents experiments, modelling and numerical simulation aimed at describing the mechanical response of human ascending aortas in the ring opening test. The objective is to quantify, from the opening angles measured in the test, the residual stress distribution along the artery wall and, afterwards, how this stress pattern changes when the artery is subjected to standard physiological pressures. The cases studied correspond to four groups including both healthy and pathological arteries. The tissues are characterized via tensile test measurements that enable to derive the material parameters of two constitutive models adopted in the present analysis. Overall, the numerical results obtained for all groups were found to be a useful data that allow to estimate the residual stress and their influence on the vessels under normal and hypertension physiological conditions.  相似文献   

9.
While common in the general population, the developmental origins of “normal” anatomic variants of the aortic arch remain unknown. Aortic arch development begins with the establishment of the second heart field (SHF) that contributes to the pharyngeal arch arteries (PAAs). The PAAs remodel during subsequent development to form the mature aortic arch and arch vessels. Retinoic acid signaling involving the biologically active metabolite of vitamin A, plays a key role in multiple steps of this process. Recent work from our laboratory indicates that the E3 ubiquitin ligase Hectd1 is required for full activation of retinoic acid signaling during cardiac development. Furthermore, our study suggested that mild alterations in retinoic acid signaling combined with reduced gene dosage of Hectd1, results in a benign aortic arch variant where the transverse aortic arch is shortened between the brachiocephalic and left common carotid arteries. These abnormalities are preceded by hypoplasia of the fourth PAA. To further explore this interaction, we investigate whether reduced maternal dietary vitamin A intake can similarly influence aortic arch development. Our findings indicate that the incidence of hypoplastic fourth PAAs, as well as the incidence of shortened transverse arch are increased with reduced maternal vitamin A intake during pregnancy. These studies provide new insights as to the developmental origins of these benign aortic arch variants.  相似文献   

10.
Background. Currently, mechanical support is the most promising alternative to cardiac transplantation. Ventricular assist devices (VADs) were originally used to provide mechanical circulatory support in patients awaiting planned heart transplantation (‘bridge-to-transplantation’ therapy). The success of short-term bridge devices led to clinical trials evaluating the clinical suitability of long-term support (‘destination’ therapy) with left ventricular assist devices (LVADs). The first larger scale, randomised trial that tested long-term support with an LVAD reported a 44% reduction in the risk of stroke or death in patients with an LVAD. In spite of the success of LVADs as bridge-to-transplantation and long-term support, patients managed by these devices are still at risk of several adverse events. The most devastating complication is caused by embolisation of thrombi formed within the LVAD or inside the heart into the brain. Prevention of thrombi formation is attempted through anticoagulation management and by improving LVADs design; however, there is still significant occurrence of thromboembolic events in patients. Investigators have reported that the incidence of thromboembolic cerebral events ranges from 14% to 47% over a period of 6–12 months.

Methods and approach. An alternative method to reduce the incidence of cerebral embolisation is proposed by the co-authors, and the hypothesis is that it is possible to minimise the number of thrombi flowing into the carotid and vertebral arteries by an optimal placement of the LVAD outflow conduit, with or without the addition of aortic bypass connecting the ascending aorta and the innominate artery (IA), or left carotid artery. This paper presents the computational fluid dynamics (CFD) analysis of the aortic arch haemodynamics using a representative geometry of the human aortic arch with or without an alternative aortic bypass. In order to study the trajectory of the thrombi within the aortic arch bed, the CFD code, Fluent 6.3, is utilised to resolve the flow field and to solve the Lagrangian particle tracking of thrombi released randomly at the inlet of the LVAD cannula.

Results. Results are presented for simulations of thrombi in the range of 2–5 mm. The percentage of individual diameter as well as aggregate diameter thrombi flowing to the carotid and vertebral arteries as a function of LVAD conduit placement and aortic bypass implantation is reported. The influence of the LVAD conduit implantation and bypass reveals a nearly 50% variation in predicted cerebral embolism rates.

Conclusions. The adjustment of the location of the anastomosis of the LVAD outflow cannula as well as its angle of incidence plays a significant role in the level of thromboembolisms. By proper adjustment in this CFD study of a synthetic model of an aortic arch bed, we found that nearly a 50% reduction in cerebral embolism could be achieved for a configuration consisting of a shallow angle of implantation over a baseline normal incidence of the LVAD cannula. Within the limitations of our model, we have established that the LVAD implantation geometry is an important factor and should be taken into consideration when implanting an LVAD. It is possible that other parameters such as distance of the LVAD outflow cannula to the root of the IA could affect the thrombi embolisation probabilities. However, the results of this study suggest that the risk of stroke may be significantly reduced by as much as 50% by tailoring the VAD implantation by a simple surgical manoeuvre. The results of this line of research may ultimately lead to techniques that can be used to estimate the optimal LVAD configuration in a patient-specific manner by pre-operative imaging.  相似文献   

11.
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10–28 mmHg) whereas the influence of corneal thickness was studied by inducing a uniform variation (300–600 microns). A Computer Fluid Dynamics (CFD) air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non-contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine the membrane and bending corneal behavior.  相似文献   

12.
Calcification is a marked pathological component in carotid artery plaque. Studies have suggested that calcification may induce regions of high stress concentrations therefore increasing the potential for rupture. However, the mechanical behaviour of the plaque under the influence of calcification is not fully understood. A method of accurately characterising the calcification coupled with the associated mechanical plaque properties is needed to better understand the impact of calcification on the mechanical behaviour of the plaque during minimally invasive treatments. This study proposes a comparison of biochemical and structural characterisation methods of the calcification in carotid plaque specimens to identify plaque mechanical behaviour.Biochemical analysis, by Fourier Transform Infrared (FTIR) spectroscopy, was used to identify the key components, including calcification, in each plaque sample. However, FTIR has a finite penetration depth which may limit the accuracy of the calcification measurement. Therefore, this FTIR analysis was coupled with the identification of the calcification inclusions located internally in the plaque specimen using micro x-ray computed tomography (μX-CT) which measures the calcification volume fraction (CVF) to total tissue content. The tissue characterisation processes were then applied to the mechanical material plaque properties acquired from experimental circumferential loading of human carotid plaque specimen for comparison of the methods.FTIR characterised the degree of plaque progression by identifying the functional groups associated with lipid, collagen and calcification in each specimen. This identified a negative relationship between stiffness and 'lipid to collagen' and 'calcification to collagen' ratios. However, μX-CT results suggest that CVF measurements relate to overall mechanical stiffness, while peak circumferential strength values may be dependent on specific calcification geometries. This study demonstrates the need to fully characterise the calcification structure of the plaque tissue and that a combination of FTIR and μX-CT provides the necessary information to fully understand the mechanical behaviour of the plaque tissue.  相似文献   

13.
Bone strength is determined by the mechanical properties of bone material, and the size and shape of the whole bone, i.e., its architecture. The mandible of vertebrates has been traditionally regarded as a beam oriented in relation to main masticatory loads, i.e., the longer dimension of its cross‐section being parallel to the load. Rodents follow this pattern but, in addition, their mandible possesses an intriguing arch‐like shape that is apparent when seen in the lateral view. Little attention was given to the structural capacity of this trait. The advantage of an arch is that it can withstand a greater load than a horizontal beam. The objective of this study was to model the rodent mandible like an arch to evaluate its structural strength. The bending moment in an arch‐like mandible was 15–25% lower with respect to a beam‐like mandible. Further, bending varies with mandible “slenderness” and incisor procumbency, a functionally relevant rodent trait. In the rodent Ctenomys talarum (Caviomorpha; Ctenomyidae), bone stress was substantially reduced when the mandible was modeled as an arch‐like structure as compared with a beam‐like structure, and safety factors were 15–34% higher. The shape of rodents' mandible might confer a functional advantage to high and repeatedly applied loads resulting from a unique feeding mode: gnawing. J. Morphol. 277:879–887, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

14.
Multilayer structure of the artery can have significant effects on the resulting mechanical behaviour of the artery wall. Separation of the artery into individual layers is sometimes performed to identify the layer-specific parameters of constitutive model proposed by Holzapfel, Gasser and Ogden (HGO model). Inspired by this single-layer model, a double-layer model was formulated and used for identification of material parameters from homogenised stress-strain data (of non-separated artery wall). The paper demonstrates that the layer-specific parameters of the double-layer constitutive model can be identified without the need of artery separation. The resulting double-layer model can credibly describe the homogenised stress-strain behaviour of the real artery wall including large-strain stiffening effects attributed to multilayer nature of the artery.  相似文献   

15.
16.
This work was concerned with the numerical simulation of the behaviour of aortic valves whose material can be modelled as non-linear elastic anisotropic. Linear elastic models for the valve leaflets with parameters used in previous studies were compared with hyperelastic models, incorporating leaflet anisotropy with pronounced stiffness in the circumferential direction through a transverse isotropic model. The parameters for the hyperelastic models were obtained from fits to results of orthogonal uniaxial tensile tests on porcine aortic valve leaflets. The computational results indicated the significant impact of transverse isotropy and hyperelastic effects on leaflet mechanics; in particular, increased coaptation with peak values of stress and strain in the elastic limit. The alignment of maximum principal stresses in all models follows approximately the coarse collagen fibre distribution found in aortic valve leaflets. The non-linear elastic leaflets also demonstrated more evenly distributed stress and strain which appears relevant to long-term scaffold stability and mechanotransduction.  相似文献   

17.
Anomalies of the aortic arch have long been of anatomicoclinical interest. Recent studies on gene-targeted mice have identified the candidate genes that are involved in the patterning and remodeling of the pharyngeal arch arteries. In this review, we discuss our present knowledge with regard to the signaling molecules that regulate specific aspects of arch artery development. We focus first on Hoxa3, because it plays a critical role in the regulation of the differentiation of the third pharyngeal arch. Hoxa3 is expressed by the neural crest cells that originate from the rhombomeres, viz., (r)5, r6, and r7, and populate the third pharyngeal arch; it is also expressed in the third pharyngeal pouch. In Hoxa3 homozygous null mutant mice, the third arch artery degenerates bilaterally at embryonic day 11.5, resulting in the malformation of the carotid artery system. Complex combinatorial signals among the neural crest cells, pharyngeal mesoderm, ectoderm, and pouch endoderm are required for the proper development of the arch arterial system. Therefore, we highlight the numerous signaling pathways and individual genes expressed by the ectomesenchymal neural crest cells and also by the other epithelial and mesodermal cells of the pharynx. Defects in these genes result in malformations of the arch artery derivatives. This review should deepen our understanding of congenital human syndromes with abnormal patterns of pharyngeal arch arteries.  相似文献   

18.
Characterizing compressive transient large deformation properties of biological tissue is becoming increasingly important in impact biomechanics and rehabilitation engineering, which includes devices interfacing with the human body and virtual surgical guidance simulation. Individual mechanical in vivo behaviour, specifically of human gluteal adipose and passive skeletal muscle tissue compressed with finite strain, has, however, been sparsely characterised. Employing a combined experimental and numerical approach, a method is presented to investigate the time-dependent properties of in vivo gluteal adipose and passive skeletal muscle tissue. Specifically, displacement-controlled ramp-and-hold indentation relaxation tests were performed and documented with magnetic resonance imaging. A time domain quasi-linear viscoelasticity (QLV) formulation with Prony series valid for finite strains was used in conjunction with a hyperelastic model formulation for soft tissue constitutive model parameter identification and calibration of the relaxation test data. A finite element model of the indentation region was employed. Strong non-linear elastic but linear viscoelastic tissue material behaviour at finite strains was apparent for both adipose and passive skeletal muscle mechanical properties with orthogonal skin and transversal muscle fibre loading. Using a force-equilibrium assumption, the employed material model was well suited to fit the experimental data and derive viscoelastic model parameters by inverse finite element parameter estimation. An individual characterisation of in vivo gluteal adipose and muscle tissue could thus be established. Initial shear moduli were calculated from the long-term parameters for human gluteal skin/fat: G(∞,S/F)=1850 Pa and for cross-fibre gluteal muscle tissue: G(∞,M)=881 Pa. Instantaneous shear moduli were found at the employed ramp speed: G(0,S/F)=1920 Pa and G(0,M)=1032 Pa.  相似文献   

19.
We have studied the mechanical behaviour of avian long bones as whole structures, by calculating mechanical parameters such as maximum load, stiffness, bending strength and flexural Young's modulus; bones were always tested in three-point bending. Furthermore composition in several chemical elements and amino acids related to collagen content was also analysed. Correlations were established between body mass, mechanical parameters and chemical contents. Both bending strength and Young's modulus were negatively correlated to body mass. Significant correlations were found between nitrogen content and both strength and Young's modulus, with negative slopes in both cases. Magnesium and phosphorus appear to be the most important inorganic elements to the understanding of the mechanical behaviour of avian long bones.  相似文献   

20.
Mechanical behaviour modelling of balloon-expandable stents   总被引:9,自引:0,他引:9  
Endoprostheses are small struts placed by intravascular way to restore the vascular lumen and flow conditions. The purpose of this work is to provide models for evaluation and characterisation of some mechanical properties of a balloon-expandable stent by using the finite element method. Here we present the results for a metallic tubular peripheral prosthesis: the P308 Palmaz stent. We focus on the mechanisms linked to the structure expansion and its long-term behaviour. Several models are constructed in order to determine the stent shape after dilation and to assess the stress and strain fields in its wall due to this transformation. They inform us about the shortening percentage on expansion, degrees of radial and longitudinal recoil, and weaknesses of the structure. Various methods, differing in their levels of complexity, are then attempted to exhibit the predominant factors responsible for the crushing of a stent under external pressure. Moreover, the sensitivity of this critical pressure to geometric imperfections is studied. Lastly, since this kind of material is implanted for a lifetime, we test the stent with regard to fatigue life. Beyond safety considerations, this type of characterisation provides mechanical properties that are often difficult to obtain by experiments. If it was available for various stents, such information could be used to choose the appropriate prosthesis for specific applications. Moreover, confronted with observations from practitioners, they might lead to a better understanding of the failure or success of a particular design and to work on the product optimisation.  相似文献   