首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Direct matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of human serum yielded ion signals from only a fraction of the total number of peptides and proteins expected to be in the sample. We increased the number of peptide and protein ion signals observed in the MALDI-TOF mass spectra analysis of human serum by using a prefractionation protocol based on liquid phase isoelectric focusing electrophoresis. This pre-fractionation technique facilitated the MALDI-TOF MS detection of as many as 262 different peptide and protein ion signals from human serum. The results obtained from three replicate fractionation experiments on the same serum sample indicated that 148 different peptide and protein ion signals were reproducibly detected using our isoelectric focusing and MALDI-TOF MS protocol.  相似文献   

2.
The influence of the matrix solution, sample form and deposition technique on the quality MALDI-TOF mass spectra was examined and assessed with the aim to improve MALDI-TOF MS performance for the identification of microorganisms and to enable automatic spectra acquisition. It was observed that the use of matrix compounds ferulic and sinapinic acid may result in improved mass spectral features, in terms of signal resolution and S/N ratio, as compared to alpha-cyano-4-hydroxycinnamic acid, which was, on the other hand, found to be the only matrix compound that enabled fully automatic mass spectra acquisition. The robustness of the whole sample preparation procedure was then assessed on a set of 25 strains of four Acinetobacter species. Results showed reproducible detection of subtle mass spectral differences between strains belonging to the same species, although they do not confirm the possibility of reliable strain typing.  相似文献   

3.
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) has been recently used to identify disease markers by directly profiling and quantifying the peptide/proteins in biological samples under different physiological or experimental conditions. The information of reproducibility of such quantitative profiling method has not been available. It is important to evaluate and reduce error from technical variation. In this study, an unbiased signal acquisition strategy was used to evaluate the effects of three sample-matrix spotting methods and two matrix chemicals, α-cyano-4-hydroxycinnamic acid (CHCA) and sinapinic acid, on the reproducibility of the peptide/protein signal intensities. The sandwich spotting method using 0.1% nitrocellulose coating film and CHCA gave the best quantitative results for the standard peptides and proteins with mass<66.5 kDa. The normalized signal intensities of the standard peptides and proteins were directly proportional to their concentrations with intra-assay (within-day) coefficient of variations (CVs) ranging from 6.5% to 17%. When analyzing serum peptides <6000 m/z, the interassay (between-days) CVs of all the evaluated peptide peaks were <15%. These data indicate that with the right MS analysis conditions, MALDI-TOF MS appears to be a feasible tool for directly profiling and quantifying the peptide/ proteins in biological samples.  相似文献   

4.
We describe a method for assessing the quality of mass spectra and improving reliability of relative ratio estimations from (18)O-water labeling experiments acquired from low resolution mass spectrometers. The mass profiles of heavy and light peptide pairs are often affected by artifacts, including coeluting contaminant species, noise signal, instrumental fluctuations in measuring ion position and abundance levels. Such artifacts distort the profiles, leading to erroneous ratio estimations, thus reducing the reliability of ratio estimations in high throughput quantification experiments. We used support vector machines (SVMs) to filter out mass spectra that deviated significantly from expected theoretical isotope distributions. We built an SVM classifier with a decision function that assigns a score to every mass profile based on such spectral features as mass accuracy, signal-to-noise ratio, and differences between experimental and theoretical isotopic distributions. The classifier was trained using a data set obtained from samples of mouse renal cortex. We then tested it on protein samples (bovine serum albumin) mixed in five different ratios of labeled and unlabeled species. We demonstrated that filtering the data using our SVM classifier results in as much as a 9-fold reduction in the coefficient of variance of peptide ratios, thus significantly improving the reliability of ratio estimations.  相似文献   

5.
This paper presents computational methods to analyze MALDI-TOF mass spectrometry data for quantitative comparison of peptides and glycans in serum. The methods are applied to identify candidate biomarkers in serum samples of 203 participants from Egypt; 73 hepatocellular carcinoma (HCC) cases, 52 patients with chronic liver disease (CLD) consisting of cirrhosis and fibrosis cases, and 78 population controls. Two complementary sample preparation methods were applied prior to generating mass spectra: (1) low molecular weight (LMW) enrichment of each serum sample was carried out for MALDI-TOF quantification of peptides, and (2) glycans were enzymatically released from proteins in each serum sample and permethylated for MALDI-TOF quantification of glycans. A peak selection algorithm was applied to identify the most useful peptide and glycan peaks for accurate detection of HCC cases from high-risk population of patients with CLD. In addition to global peaks selected by the whole population based approach, where identically labeled patients are treated as a single group, subgroup-specific peaks were identified by searching for peaks that are differentially abundant in a subgroup of patients only. The peak selection process was preceded by peak screening, where we eliminated peaks that have significant association with covariates such as age, gender, and viral infection based on the peptide and glycan spectra from population controls. The performance of the selected peptide and glycan peaks was evaluated in terms of their ability in detecting HCC cases from patients with CLD in a blinded validation set and through the cross-validation method. Finally, we investigated the possibility of using both peptides and glycans in a panel to enhance the diagnostic capability of these candidate markers. Further evaluation is needed to examine the potential clinical utility of the candidate peptide and glycan markers identified in this study.  相似文献   

6.
The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.  相似文献   

7.
The occurrence of harmful algal blooms (HABs) or red tides is an important and expanding threat to human health, fishery resources, and the tourism industries. Toxic species post an additional treat of intoxication when consumed either in seafood or directly swallowed. Rapid and accurate identification of the HAB species is critical for minimizing or controlling the damage. We report the use of protein/peptide mass fingerprint profiles obtained with matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) for the identification of dinoflagellates, common causative agents of HABs. The method is simple, fast and reproducible. The peptide mass fingerprint spectral patterns are unique for different dinoflagellate species and are easily distinguishable by visual inspection. In addition to the whole mass spectra, several specific biomarkers were identified from the mass spectra of different species. These biomarker ions and the mass spectral patterns form an unambiguous basis for species discrimination.  相似文献   

8.
Matrix assisted laser desorption/ionization time-of-flight (MALDI-TOF) coupled with stable isotope standards (SIS) has been used to quantify native peptides. This peptide quantification by MALDI-TOF approach has difficulties quantifying samples containing peptides with ion currents in overlapping spectra. In these overlapping spectra the currents sum together, which modify the peak heights and make normal SIS estimation problematic. An approach using Gaussian mixtures based on known physical constants to model the isotopic cluster of a known compound is proposed here. The characteristics of this approach are examined for single and overlapping compounds. The approach is compared to two commonly used SIS quantification methods for single compound, namely Peak Intensity method and Riemann sum area under the curve (AUC) method. For studying the characteristics of the Gaussian mixture method, Angiotensin II, Angiotensin-2-10, and Angiotenisn-1-9 and their associated SIS peptides were used. The findings suggest, Gaussian mixture method has similar characteristics as the two methods compared for estimating the quantity of isolated isotopic clusters for single compounds. All three methods were tested using MALDI-TOF mass spectra collected for peptides of the renin-angiotensin system. The Gaussian mixture method accurately estimated the native to labeled ratio of several isolated angiotensin peptides (5.2% error in ratio estimation) with similar estimation errors to those calculated using peak intensity and Riemann sum AUC methods (5.9% and 7.7%, respectively). For overlapping angiotensin peptides, (where the other two methods are not applicable) the estimation error of the Gaussian mixture was 6.8%, which is within the acceptable range. In summary, for single compounds the Gaussian mixture method is equivalent or marginally superior compared to the existing methods of peptide quantification and is capable of quantifying overlapping (convolved) peptides within the acceptable margin of error.  相似文献   

9.
Analysis of the human serum proteome   总被引:1,自引:0,他引:1  
Changes in serum proteins that signal histopathological states, such as cancer, are useful diagnostic and prognostic biomarkers. Unfortunately, the large dynamic concentration range of proteins in serum makes it a challenging proteome to effectively characterize. Typically, methods to deplete highly abundant proteins to decrease this dynamic protein concentration range are employed, yet such depletion results in removal of important low abundant proteins. A multi-dimensional peptide separation strategy utilizing conventional separation techniques combined with tandem mass spectrometry (MS/MS) was employed for a proteome analysis of human serum. Serum proteins were digested with trypsin and resolved into 20 fractions by ampholyte-free liquid phase isoelectric focusing. These 20 peptide fractions were further fractionated by strong cation-exchange chromatography, each of which was analyzed by microcapillary reversed-phase liquid chromatography coupled online with MS/MS analysis. This investigation resulted in the identification of 1444 unique proteins in serum. Proteins from all functional classes, cellular localization, and abundance levels were identified. This study illustrates that a majority of lower abundance proteins identified in serum are present as secreted or shed species by cells as a result of signalling, necrosis, apoptosis, and hemolysis. These findings show that the protein content of serum is quite reflective of the overall profile of the human organism and a conventional multidimensional fractionation strategy combined with MS/MS is entirely capable of characterizing a significant fraction of the serum proteome. We have constructed a publicly available human serum proteomic database (http://bpp.nci.nih.gov) to provide a reference resource to facilitate future investigations of the vast archive of pathophysiological content in serum. These authors contributed equally to this work.  相似文献   

10.
Many abnormalities detected in the thorax by routine conventional imaging studies are benign, yet all require further evaluation because of the concern for cancer. To address this deficiency and develop a serum biomarker for lung cancer, we designed a matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) based platform to display the proteins present in the serum of patients with or without lung cancer, and then challenged the scientific community to analyze these data with the aim of determining specific ion signal differences among the resulting spectra. The most statistically significant ion peak identified by the various analysis algorithms that differentiated the serum of patients with lung cancer from the serum of individuals without lung cancer was found at m/z 11,702. We identified the protein responsible for this ion peak as serum amyloid A (SAA; M(r) = 11,682.7) by partial purification followed by in-gel digestion and peptide mapping. By enzyme-linked immunosorbent assay, we showed SAA to be present at 286 ng/mL in the serum of cancer patients vs. 34.1 ng/mL in the serum of individuals without cancer. These data suggest that the combination of MALDI-TOF MS and computer analysis can be a powerful tool in the search for serum biomarkers of lung cancer and other diseases.  相似文献   

11.
12.
Discovery of biomarker patterns using proteomic techniques requires examination of large numbers of patient and control samples, followed by data mining of the molecular read-outs (e.g., mass spectra). Adequate signal processing and statistical analysis are critical for successful extraction of markers from these data sets. The protocol, specifically designed for use in conjunction with MALDI-TOF-MS-based serum peptide profiling, is a data analysis pipeline, starting with transfer of raw spectra that are interpreted using signal processing algorithms to define suitable features (i.e., peptides). We describe an algorithm for minimal entropy-based peak alignment across samples. Peak lists obtained in this way, and containing all samples, all peptide features and their normalized MS-ion intensities, can be evaluated, and results validated, using common statistical methods. We recommend visual inspection of the spectra to confirm all results, and have written freely available software for viewing and color-coding of spectral overlays.  相似文献   

13.
Purified native Tromp1 was subjected to mass spectrometric analysis in order to determine conclusively whether this protein possesses a cleaved or uncleaved signal peptide. The molecular masses of Tromp1, three Treponema pallidum lipoproteins, and a bovine serum albumin (BSA) control were determined by matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry. The molecular masses of all of the T. pallidum lipoproteins and BSA were within 0.7% of their respective calculated masses. The molecular mass of Tromp1 was 31,510 Da, which is consistent with a signal-less form of Tromp1, given a calculated mass of unprocessed Tromp1 of 33, 571 Da, a difference of 2,061 Da (a 6.5% difference). Purified native Tromp1 was also subjected to MALDI-TOF analysis in comparison to recombinant Tromp1 following cyanogen bromide cleavage, which further confirmed the identity of Tromp1 and showed that native Tromp1 was not degraded at the carboxy terminus. These studies confirm that Tromp1 is processed and does not contain an uncleaved signal peptide as previously reported.  相似文献   

14.
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is routinely used for bacterial identification. It would be highly beneficial to also be able to use the technology as a fast way to detect clinically relevant clones of bacterial species. However, studies to this aim have often had limited success. The methods used for data acquisition, processing and data interpretation are highly diverse amongst studies on MALDI-TOF MS sub-species typing. In addition to this, feasibility may depend on the bacterial species and strains investigated, making it difficult to determine what methods may or may not work. In our paper, we have reviewed recent research on MALDI-TOF MS typing of bacterial strains. Although we found a lot of variation amongst the methods used, there were approaches shared by multiple research groups. Multiple spectra of the same isolate were often combined before further analysis for strain distinction. Many groups used a protein extraction step to increase resolution in their MALDI-TOF MS results. Peaks at a high mass range were often excluded for data interpretation. Three groups have found ways to determine feasibility of MALDI-TOF MS typing for their set of strains at an early stage of their project.  相似文献   

15.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an emerging technique for the rapid and high-throughput identification of microorganisms. There remains a dearth of studies in which a large number of pathogenic microorganisms from a particular country or region are utilized for systematic analyses. In this study, peptide mass reference spectra (PMRS) were constructed and evaluated from numerous human pathogens (a total of 1019 strains from 94 species), including enteric (46 species), respiratory (21 species), zoonotic (17 species), and nosocomial pathogens (10 species), using a MALDI-TOF MS Biotyper system (MBS). The PMRS for 380 strains of 52 species were new contributions to the original reference database (ORD). Compared with the ORD, the new reference database (NRD) allowed for 28.2% (from 71.5% to 99.7%) and 42.3% (from 51.3% to 93.6%) improvements in identification at the genus and species levels, respectively. Misidentification rates were 91.7% and 57.1% lower with the NRD than with the ORD for genus and species identification, respectively. Eight genera and 25 species were misidentified. For genera and species that are challenging to accurately identify, identification results must be manually determined and adjusted in accordance with the database parameters. Through augmentation, the MBS demonstrated a high identification accuracy and specificity for human pathogenic microorganisms. This study sought to provide theoretical guidance for using PMRS databases in various fields, such as clinical diagnosis and treatment, disease control, quality assurance, and food safety inspection.  相似文献   

16.
ABSTRACT: BACKGROUND: In this study mass spectrometry was used for evaluating extracted leptospiral protein samples and results were compared with molecular typing methods. For this, an extraction protocol for Leptospira spp. was independently established in two separate laboratories. Reference spectra were created with 28 leptospiral strains, including pathogenic, non-pathogenic and intermediate strains. This set of spectra was then evaluated on the basis of measurements with well-defined, cultured leptospiral strains and with 16 field isolates of veterinary or human origin. To verify discriminating peaks for the applied pathogenic strains, statistical analysis of the protein spectra was performed using the software tool ClinProTools. In addition, a dendrogram of the reference spectra was compared with phylogenetic trees of the 16S rRNA gene sequences and multi locus sequence typing (MLST) analysis. RESULTS: Defined and reproducible protein spectra using MALDI-TOF MS were obtained for all leptospiral strains. Evaluation of the newly-built reference spectra database allowed reproducible identification at the species level for the defined leptospiral strains and the field isolates. Statistical analysis of three pathogenic genomospecies revealed peak differences at the species level and for certain serovars analyzed in this study. Specific peak patterns were reproducibly detected for the serovars Tarassovi, Saxkoebing, Pomona, Copenhageni, Australis, Icterohaemorrhagiae and Grippotyphosa. Analysis of the dendrograms of the MLST data, the 16S rRNA sequencing, and the MALDI-TOF MS reference spectra showed comparable clustering. CONCLUSIONS: MALDI-TOF MS analysis is a fast and reliable method for species identification, although Leptospira organisms need to be produced in a time-consuming culture process. All leptospiral strains were identified, at least at the species level, using our described extraction protocol. Statistical analysis of the three genomospecies L. borgpetersenii, L. interrogans and L. kirschneri revealed distinctive, reproducible differentiating peaks for seven leptospiral strains which represent seven serovars. Results obtained by MALDI-TOF MS were confirmed by MLST and 16S rRNA gene sequencing.  相似文献   

17.
At present, there is much variability between MALDI-TOF MS methodology for the characterization of bacteria through differences in e.g., sample preparation methods, matrix solutions, organic solvents, acquisition methods and data analysis methods. After evaluation of the existing methods, a standard protocol was developed to generate MALDI-TOF mass spectra obtained from a collection of reference strains belonging to the genera Leuconostoc, Fructobacillus and Lactococcus. Bacterial cells were harvested after 24 h of growth at 28 °C on the media MRS or TSA. Mass spectra were generated, using the CHCA matrix combined with a 50:48:2 acetonitrile:water:trifluoroacetic acid matrix solution, and analyzed by the cell smear method and the cell extract method. After a data preprocessing step, the resulting high quality data set was used for PCA, distance calculation and multi-dimensional scaling. Using these analyses, species-specific information in the MALDI-TOF mass spectra could be demonstrated. As a next step, the spectra, as well as the binary character set derived from these spectra, were successfully used for species identification within the genera Leuconostoc, Fructobacillus, and Lactococcus. Using MALDI-TOF MS identification libraries for Leuconostoc and Fructobacillus strains, 84% of the MALDI-TOF mass spectra were correctly identified at the species level. Similarly, the same analysis strategy within the genus Lactococcus resulted in 94% correct identifications, taking species and subspecies levels into consideration. Finally, two machine learning techniques were evaluated as alternative species identification tools. The two techniques, support vector machines and random forests, resulted in accuracies between 94% and 98% for the identification of Leuconostoc and Fructobacillus species, respectively.  相似文献   

18.
One of the important challenges for MALDI imaging mass spectrometry (MALDI-IMS) is the unambiguous identification of measured analytes. One way to do this is to match tryptic peptide MALDI-IMS m/z values with LC-MS/MS identified m/z values. Matching using current MALDI-TOF/TOF MS instruments is difficult due to the variability of in situ time-of-flight (TOF) m/z measurements. This variability is currently addressed using external calibration, which limits achievable mass accuracy for MALDI-IMS and makes it difficult to match these data to downstream LC-MS/MS results. To overcome this challenge, the work presented here details a method for internally calibrating data sets generated from tryptic peptide MALDI-IMS on formalin-fixed paraffin-embedded sections of ovarian cancer. By calibrating all spectra to internal peak features the m/z error for matches made between MALDI-IMS m/z values and LC-MS/MS identified peptide m/z values was significantly reduced. This improvement was confirmed by follow up matching of LC-MS/MS spectra to in situ MS/MS spectra from the same m/z peak features. The sum of the data presented here indicates that internal calibrants should be a standard component of tryptic peptide MALDI-IMS experiments.  相似文献   

19.

Background and Objectives

Prostate cancer (PCa) is one of the most common cancers and leading cause of cancer-related deaths in men. Mass screening has been carried out since the 1990s using prostate-specific antigen (PSA) levels in the serum as a PCa biomarker. However, although PSA is an excellent organ-specific marker, it is not a cancer-specific marker. Therefore, the aim of this study was to discover new biomarkers for the diagnosis of PCa.

Materials and Methods

We focused on urine samples voided following prostate massage (digital rectal examination [DRE]) and conducted a peptidomic analysis of these samples using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MSn). Urinary biomaterials were concentrated and desalted using CM-Sepharose prior to the following analyses being performed by MALDI-TOF/MSn: 1) differential analyses of mass spectra; 2) determination of amino acid sequences; and 3) quantitative analyses using a stable isotope-labeled internal standard.

Results

Multivariate analysis of the MALDI-TOF/MS mass spectra of urinary extracts revealed a 2331 Da peptide in urine samples following DRE. This peptide was identified as a C-terminal PSA fragment composed of 19 amino acid residues. Moreover, quantitative analysis of the relationship between isotope-labeled synthetic and intact peptides using MALDI-TOF/MS revealed that this peptide may be a new pathognomonic biomarker candidate that can differentiate PCa patients from non-cancer subjects.

Conclusion

The results of the present study indicate that the 2331 Da peptide fragment of PSA may become a new pathognomonic biomarker for the diagnosis of PCa. A further large-scale investigation is currently underway to assess the possibility of using this peptide in the early detection of PCa.  相似文献   

20.
Although peptide mass fingerprinting is currently the method of choice to identify proteins, the number of proteins available in databases is increasing constantly, and hence, the advantage of having sequence data on a selected peptide, in order to increase the effectiveness of database searching, is more crucial. Until recently, the ability to identify proteins based on the peptide sequence was essentially limited to the use of electrospray ionization tandem mass spectrometry (MS) methods. The recent development of new instruments with matrix-assisted laser desorption/ionization (MALDI) sources and true tandem mass spectrometry (MS/MS) capabilities creates the capacity to obtain high quality tandem mass spectra of peptides. In this work, using the new high resolution tandem time of flight MALDI-(TOF/TOF) mass spectrometer from Applied Biosystems, examples of successful identification and characterization of bovine heart proteins (SWISS-PROT entries: P02192, Q9XSC6, P13620) separated by two-dimensional electrophoresis and blotted onto polyvinylidene difluoride membrane are described. Tryptic protein digests were analyzed by MALDI-TOF to identify peptide masses afterward used for MS/MS. Subsequent high energy MALDI-TOF/TOF collision-induced dissociation spectra were recorded on selected ions. All data, both MS and MS/MS, were recorded on the same instrument. Tandem mass spectra were submitted to database searching using MS-Tag or were manually de novo sequenced. An interesting modification of a tryptophan residue, a "double oxidation", came to light during these analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号