首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Careful selection of patients and skillful fitting result in a high rate of success with corneal contact lenses-over 96 per cent in 339 patients treated in the present series. The lenses were especially valuable in anisometropia in children (11 cases). Children can be taught to care for contact lenses and insert and remove them for themselves.  相似文献   

2.
Careful selection of patients and skillful fitting result in a high rate of success with corneal contact lenses—over 96 per cent in 339 patients treated in the present series. The lenses were especially valuable in anisometropia in children (11 cases). Children can be taught to care for contact lenses and insert and remove them for themselves.  相似文献   

3.
Pseudomonas aeruginosa causes a variety of diseases in humans including lung and ocular infections. Infections of the cornea are usually associated with wearing contact lenses and can result in loss of vision. This study aimed to determine the effect of carbon or nitrogen limitation on the adhesion to contact lenses of a strain of Ps. aeruginosa isolated from contact lens-related corneal inflammation. Cells were grown in a continuous culture apparatus in varying levels of glucose or ammonia to effect nutrient limitation. Adhesion to contact lenses was measured as total counts and viable counts. The cell surface hydrophobicity and charge were measured using adhesion to surface-modified Sepharose. Changes in lipopolysaccharide were determined using 1D SDS-PAGE and changes in cell-surface proteins were measured using 2D gel electrophoresis. The more the cultures were nitrogen limited, the greater the increase in adhesion to unworn hydrogel contact lenses 0.3 x 10(3) - 2.2 x 10(3) cells/mm2 on Etafilon A lenses. Cells that were carbon limited showed a greater increase in adhesion to contact lenses when the lenses had been coated in artificial tears. It appeared that lipopolysaccharide may have been involved in the constitutive adhesion to unworn lenses that occurred during C-limitation, whereas changes in the outer membrane proteins contributed to the increased adhesion under nitrogen limitation, or the change in adhesion that occurred to carbon-limited cells using contact lenses coated in artificial tears. Nine cell-surface proteins appeared during nitrogen limitation with kDa/pI of 75/4.8, 4.9, 5.0; 62/5.6; 89/6.5; 38/6.4; 28/1.5; 18/6.4; 12/4.5. Any or all of these may have been involved in the increased adhesion and further experiments are underway to examine this possibility.  相似文献   

4.
This study was designed to use multiple reaction monitoring (MRM) for accurate quantification of contact lens protein deposits. Worn lenses used with a multipurpose disinfecting solution were collected after wear. Individual contact lenses were extracted and then digested with trypsin. MRM in conjunction with stable-isotope-labeled peptide standards was used for protein quantification. The results show that lysozyme was the major protein detected from both lens types. The amount of protein extracted from contact lenses was affected by the lens material. Except for keratin-1 (0.83?±?0.61 vs 0.77?±?0.20, p?=?0.81) or proline rich protein-4 (0.11?±?0.04 vs 0.15?±?0.12, p?=?0.97), the amounts of lysozyme, lactoferrin, or lipocalin-1 extracted from balafilcon A lenses (12.9?±?9.01, 0.84?±?0.50 or 2.06?±?1.6, respectively) were significantly higher than that extracted from senofilcon A lenses (0.88?±?0.13, 0.50?±?0.10 or 0.27?±?0.23, respectively) (p?相似文献   

5.
Non-invasive measurement of biomechanical properties of corneas may provide important information for ocular disease management and therapeutic procedures. An ultrasonic non-destructive evaluation method with a wave propagation model was developed to determine corneal biomechanical properties in vivo. In this study, we tested the feasibility of the approach in differentiating the mechanical properties of soft contact lenses as corneal phantoms. Three material types of soft contact lenses (six samples in each group) were measured using a broadband ultrasound transducer. The ultrasonic reflections from the contact lenses were recorded by a 500MHz/8-bit digitizer, and displayed and processed by a PC. A reference signal was recorded to compute the normalized power spectra using Fast Fourier Transformation. An inverse algorithm based on least-squares minimization was used to reconstruct three parameters of the contact lenses: density, thickness, and elastic constants lambda+2micro. The thickness of each sample was verified using an electronic thickness gauge, and the averaged density for each type of lenses was verified using Archimedes' principle and manufacturer's report. Our results demonstrated that the ultrasonic system was able to differentiate the elastic properties of the three types of the soft contact lenses with statistical significance (P-value<0.001). The reconstructed thicknesses and densities agreed well with the independent measurements. Our studies on corneal phantoms indicated that the ultrasonic system was sensitive and accurate in measuring the material properties of cornea-like structures. It is important to optimize the system for in vivo measurements.  相似文献   

6.
The capacity of 59 isolates of Serratia marcescens, obtained from urinary tract infections, wounds, and contact lenses or their paraphernalia, to agglutinate erythrocytes from different animal species was tested. Three main patterns were found: mannose-sensitive agglutination of guinea-pig, fowl or horse erythrocyte; mannose-resistant agglutination of chicken or pigeon erythrocytes alone or in combination with mannose-sensitive agglutination; and no agglutination. Hemagglutination capacity was associated with isolates from urinary tract infection, but not with isolates associated with contact lenses. Adherence to human urinary tract epithelium did not correlate with the hemagglutination patterns nor with the origin of the isolates. Some strains of different hemagglutination pattern were selected for the study of hydrophobicity and adherence to contact lens polymers. Hydrophobicity, as determined by degree of partition in hexadecane and water (BATH-values), correlated neither with degree of adherence to contact lens polymers nor with the hemagglutination pattern. For a representative strain there was an excellent correlation (r2 = 0.98) between adherence and the water content (hydrophobicity) of the lens polymers. These results suggest that, as with tissues, other factors interact with hydrophobicity in causing adherence to plastics.  相似文献   

7.
Binocular gaze was measured accurately under natural conditions with the Maryland Revolving Field Monitor to determine how visual-clarity affects gaze-accuracy. The gaze of 3 unrestrained, seated subjects (2 presbyopes and 1 myope) was recorded as they tapped 4 LEDs with a long, narrow rod cemented to a thimble worn on their index fingers. They wore positive contact lenses, permitting very clear vision only nearby, within 35 cm. This task was hard. It took more than 7 seconds to complete. Gaze-accuracy varied inversely with target-distance. Gaze was less accurate when targets were nearby, and seen clearly, than when targets were farther away and harder to see. This result was not anticipated. It implies that gaze is accurate in order to see clearly and not because targets can be seen clearly.  相似文献   

8.
Specific anti-Acanthamoeba IgA antibodies have been detected in the serum and tears of patients and healthy individuals. However, the role of human secretory IgA antibodies in inhibiting the adherence of Acanthamoeba had not been previously investigated. Therefore, the purpose of this study was to purify secretory IgA from human colostrum and analyze its effect on the adherence of Acanthamoeba trophozoites to contact lenses and Madin-Darby canine kidney (MDCK) cells. IgA antibodies to Acanthamoeba polyphaga in colostrum of healthy women as well as in saliva and serum of healthy subjects were analyzed by ELISA and Western blot analysis. In serum, saliva, and colostrum, we detected IgA antibodies that recognized several antigens of A. polyphaga. In addition, colostrum and IgA antibodies purified from it inhibited adherence of A. polyphaga trophozoites to contact lenses and MDCK cells. These results suggest that IgA antibodies may participate in the resistance to the amoebic infection, probably by inhibiting the adherence of the trophozoites to contact lenses and corneal epithelial cells.  相似文献   

9.
M. Easterbrook 《CMAJ》1978,118(3):298-5
As more Canadians are taking up squash the incidence of eye injuries is increasing dramatically. Over 2-1/2 years, 23 cases from one urban practice were examined. Almost half of the group required inhospital treatment. Five patients sustained a permanent decrease in vision; these cases involved three corneal scars, one cataract and one macular cyst. Patients wearing glasses or hard contact lenses appear to be more susceptible to serious eye injury. Experience does not appear to reduce the likelihood of eye injuries; the patients in this study had played squash for 5.6 years on the average. Consequently the medical profession must take the lead by encouraging squash players to use protective equipment now available to reduce the incidence of these injuries that pose so much personal hazard.  相似文献   

10.
This study was designed to use multiple reaction monitoring (MRM) for accurate quantification of contact lens protein deposits. Worn lenses used with a multipurpose disinfecting solution were collected after wear. Individual contact lenses were extracted and then digested with trypsin. MRM in conjunction with stable-isotope-labeled peptide standards was used for protein quantification. The results show that lysozyme was the major protein detected from both lens types. The amount of protein extracted from contact lenses was affected by the lens material. Except for keratin-1 (0.83 ± 0.61 vs 0.77 ± 0.20, p = 0.81) or proline rich protein-4 (0.11 ± 0.04 vs 0.15 ± 0.12, p = 0.97), the amounts of lysozyme, lactoferrin, or lipocalin-1 extracted from balafilcon A lenses (12.9 ± 9.01, 0.84 ± 0.50 or 2.06 ± 1.6, respectively) were significantly higher than that extracted from senofilcon A lenses (0.88 ± 0.13, 0.50 ± 0.10 or 0.27 ± 0.23, respectively) (p < 0.05). The amount of protein extracted from contact lenses was dependent on both the individual wearer and the contact lens material. This may have implications for the development of clinical responses during lens wear for different people and with different types of contact lenses. The use of MRM-MS is a powerful analytical tool for the quantification of specific proteins from single contact lenses after wear.  相似文献   

11.
Unworn soft and rigid gas-permeable contact lenses were inoculated with an Acanthamoeba keratitis strain to study the protozoon's ability to adhere. Furthermore, the efficacy of the rinsing in saline on acanthamoeba removal was evaluated, as well as the amebicidal activity of five commercial cleaning/disinfecting products: hydrogen peroxide, chlorhexidine, polyaminopropyl biguanide-poloxamine, thimerosal-polyquaternium, and thimerosal-chlorhexidine. Microscopic count of cells showed that Acanthamoeba trophozoites and cysts adhered to all types of contact lenses. A significantly greater adherence of trophozoites than cysts was recorded. The rinsing in saline using a flow-method was significantly more effective than the immersion-method, particularly in removing trophozoites from rigid gas-permeable lenses. The cleaning/disinfecting solutions tested were ineffective in removing or in affecting the viability of all Acanthamoeba trophozoites or cysts in the 17 hours allotted for the experiment. The need for a better care in mechanical and physical hygiene procedures is stressed.  相似文献   

12.

Purpose

To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs).

Methods

One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL), with -5.0 diopters (D), -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated.

Results

The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time.

Conclusions

Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.  相似文献   

13.
Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the tear film protein lysozyme. PureVision balafilcon A and AirOptix lotrafilcon B lenses were soaked for five days in either phosphate buffered saline (PBS), borate buffered saline (BBS), or Sensitive Eyes Plus Saline Solution (Sensitive Eyes), either pure or in the presence of lysozyme. Treated contact lenses were then contacted to a live monolayer of corneal epithelial cells for two hours, after which the contact lens was sheared laterally. The apparent cell monolayer relaxation modulus was then used to quantify the extent of cell adhesion to the contact lens surface. For both lens types, lysozyme increased corneal cell adhesion to the contact lens, with the apparent cell monolayer relaxation modulus increasing up to an order of magnitude in the presence of protein. The magnitude of this increase depended on the identity of the soaking solution: lenses soaked in borate-buffered solutions (BBS, Sensitive Eyes) exhibited a much greater increase in cell attachment upon protein addition than those soaked in PBS. Significantly, all measurements were conducted while subjecting the cells to moderate surface pressures and shear rates, similar to those experienced by corneal cells in vivo.  相似文献   

14.
The growth of six strains of yeast was analyzed in vitro in order to assess their capacity for colonizing (adhesion and invasion) hydrophilic contact lenses. Lenses with different water content were cultured in two culture media for 3, 7, 14, and 21 days. Only strain 93150 of Candida albicans could adhere to and invade the polymers. Specifically, fungal growth was observed in cultures with Sabourauds broth. The degree of yeast colonization of contact lenses was significantly related to the species, the strain, and the culture medium in which the yeast and lenses were cultured. The results here obtained were compared with those reported for the filamentous fungus Aspergillus niger 2700. For both microorganisms, the strain and the medium in which the lenses and microorganism were cultured influenced the colonization, but the percentage of colonized lenses, the degree of colonization, and the density and size of the internalized colonies were always noticeably lower for C. albicans 93150. Colonization by A. niger 2700 was also related to the type of material of the lenses and the incubation period. For both microorganisms, when the strain is right and the growth and development are correct, colonization of hydrophilic contact lenses occurs.  相似文献   

15.
With the aim of developing a new cholesterol esterase for eliminating lipids on used contact lenses, microorganisms were screened for the enzyme activity. A Pseudomonas aeruginosa isolated from soil was found to produce a desirable enzyme. The enzyme had an isoelectric point of 3.2, and molecular mass of 58 kDa. The optimal temperature was around 53 degrees C at pH 7.0, and the optimal pH was from 5.5 to 9.5. The enzyme was stable between pH 5 and 10 for 19 h at 25 degrees C, and retained its activity up to 53 degrees C on 30 min of incubation at pH 7.0. The rates of hydrolysis of cholesteryl esters of different fatty acids were in the following order: linoleate > oleate > stearate > palmitate > caprylate > myristate > laurate, caprate > caproate > butyrate, acetate. Addition of (tauro)cholate to a final concentration of 100 mM markedly promoted the hydrolysis of triglycerides of short-, medium-, and long-chain fatty acids. When used with taurocholate, the enzyme acted as an effective cleaner for contact lenses stained with lipids consisting of cholesteryl oleate, tripalmitin, and stearyl stearate.  相似文献   

16.
S. marcescens 8100 andP. aeruginosa 15442 were used to study bacterial adhesion to hydrogel contact lenses which had not been worn. Bacterial removal from unworn lens materials was assessed with a calibrated vortex device modified with a digital rpm readout and fitted with a test tube attachment (MVD). The MVD, which relies on a whirlpool-like force to remove the bacteria, showed that bacteria adhered to the same degree to etafilcon A, vifilcon A and polymacon lenses under standardized conditions. Tracking the isoenzyme patterns of these bacterial species over time showed instability ofS. marcescens upon repeated passage. This instability was not evident withP. aeruginosa. Bacterial adhesion ofP. aeruginosa 15442, to human worn and unworn etafilcon A materials was determined with a Modified Robbins Device. The MRD was closed off at both ends stopping medium and bacterial movement after 1 h of fluid flow over the lens surface. The results show that immediately following this 1-h period more bacteria adhere to unworn contact lenses than to worn lenses. However, bacterial counts were equivalent on worn and unworn lenses following 5 h of static incubation.  相似文献   

17.
Objective: a study was conducted at the University of Houston College of Optometry to test the efficacy of two multi-purpose and one two-step patient care systems in the disinfection and storage of diagnostic soft contact lenses. Study design: the solutions investigated were OPTI-ONE™, COMPLETE®, and Quick CARE™, which contain polyquad/citrate, trischem, and isopropyl alcohol respectively. Solutions from 60 vials containing recently used diagnostic soft lenses were tested for initial bacterial growth and the organisms identified. The lenses were then cleaned and disinfected according to the manufacturer's instructions. The solution from each vial was then tested for bacterial growth at the manufacturer's minimum recommended length of time for disinfection and subsequently at weekly intervals for 4 weeks. Results: growth was significantly greater with OPTI-ONE™ than with COMPLETE® or Quick CARE™. Serratia marcescens was the organism most frequently found. Conclusion: COMPLETE® and Quick CARE™ appear to be efficient and efficacious systems for in-office disinfection of diagnostic soft lenses.  相似文献   

18.
The role of sight in the dominance hierarchy of groups of eight pigs was studied by the induction of temporary blindness using opaque contact lenses or hoods which covered the face. The effect of blindness was examined in three social situations: (i) the simultaneous introduction of eight previously unacquainted, blinded pigs; (ii) groups of pigs with a known social order were blinded and (iii) a single pig within a group of known social order was blinded. The contact lenses had a minimal effect on the hierarchy formation whilst both the lenses and the hoods had no effect on the established groups. The hoods prevented hierarchy formation amongst the unacquainted pigs. It is suggested that sight alone is not necessary for hierarchy maintenance and that the hoods stopped the formation of a hierarchy by an effect other than the deprivation of sight, e.g. by covering pheromone producing areas.  相似文献   

19.
Allan Guan  Zhenyu Li 《Biofouling》2013,29(9-10):689-697
Block co-polymer surfactants have been used for cleaning hydrogel medical devices that contact the body (eg contact lenses) because of their biocompatibility. This work examined the relationship between concentration and detergency of two non-ionic polymeric surfactants (Pluronic F127 and Triton X-100) for cleaning protein soil, with anionic surfactants (sodium dodecyl sulfate and sodium laureth sulfate) as positive controls. Surface plasmon resonance was used to quantify removal of simulated tear soil from self-assembled monolayer surfaces, and a microplate format was used to study the removal of fluorescently labeled soil proteins from contact lenses. While detergency increased as a function of concentration for anionic surfactants, it decreased with concentration for the two polymeric surfactants. The fact that the protein detergency of some non-ionic polymeric surfactants did not increase with concentration above the critical micelle concentration could have implications for optimizing the tradeoff between detergency and biocompatibility.  相似文献   

20.
Summary An alkaline protease, previously isolated from a symbiotic bacterium found in the gland of Deshayes of marine shipworm, was evaluated as a cleansing additive. The protease nearly doubled the cleaning power of a standard phosphate detergent at temperatures up to 50°C as determined by fabric swatch assays. The enzyme was, however, ineffective at 70°C. In both fresh and seawater, it was also an efficient presoak. The cleaning power of a non-phosphate detergent was significantly improved by added protease, independent of the pH range 10 to 12. The enzyme degraded lysozyme, the major protein contaminant of contact lenses, more extensively than subtilisin and was effective in solutions containing hydrogen peroxide, often employed to sterilize lenses. The protease was unusually stable in sodium perborate, as well as hydrogen peroxide, and retained good activity in the presence of sodium hypochloride.  相似文献   