首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
J C Bearden 《Gene》1979,6(3):221-234
A new theoretical model for the migration of high-molecular-weight, double-stranded DNA on agarose gels is presented. This leads to the prediction that under certain conditions of electrophoresis, a linear relationship will exist between the molecular weight of a DNA molecule, raised to the (-2/3) power, and its electrophoretic mobility. Agarose gel electrophoresis of the fragments of bacteriophage lambda DNA produced by several restriction endonucleases confirms this relationship, and establishes some of the limits on its linearity. For this work, a polyacrylamide slab gel apparatus was modified for use with agarose gels. This apparatus has several advantages over others commercially available for agarose gel electrophoresis, including the abilities to run a larger number of samples at one time, to use lower-concentration gels, and to maintain better temperature stability across the width of the gel. The validation of the relationship developed here between molecular weight and electrophoretic mobility should make this a useful method for determining the molecular weights of DNA fragments.  相似文献   

2.
An extensive series of experiments has been performed to study the mobility of DNA fragments ranging in size from 2.0 to 48.5 kilobose pairs. By varying the agarose concentration in the gels and the electric field strength, three DNA electrophoresis regimes were clearly identified: the Ogston regime (small DNA fragments in large pores of agarose), the reptation regime without DNA chain stretching (small pores of agarose and weak electric fields), and the reptation regime with DNA chain stretching (small pores of agarose, strong electric fields, and large DNA fragments). Here we report on the experimental identification of these regimes and on the conditions governing the transition between each of them. The onset of reptation and of stretching of DNA chains in gel electrophoresis are described quantitatively for the first time, and a phase diagram for the dynamics of DNA during electrophoresis is presented.  相似文献   

3.
Zhang JH  Wang F  Wang TY 《Gene》2011,487(1):72-74
In the paper, we describe a unique effective electrophoresis buffer for DNA agarose electrophoresis, called SuperBuffer. Using this buffer, electrophoresis could be performed within 10 min at voltages as high as 25 V/cm. In addition, DNA fragments of different lengths could be isolated clearly even at lower agarose gel concentrations and the DNA recovery efficiency was higher than that of the TAE/TBE running buffers. The SuperBuffer still retained its electrophoretic effect even after several uses.  相似文献   

4.
The electrophoretic mobilities of DNA polymer fragments in an agarose gel have been measured from a photograph of the gel by different methods and converted to lengths by the reciprocal method. The method of measurement can introduce large errors in the length estimates. The use of a digital microdensitometer to obtain optical density profiles of gel tracks with subsequent computer processing to find peak positions was found to give the most accurate DNA lengths.  相似文献   

5.
BACKGROUND: A flow cytometric measurement (FCM) technique has been developed to size DNA fragments. Individual fragments of a restriction digest of genomic DNA, stained with an intercalating dye, are passed through an ultrasensitive cytometer. The measured fluorescence intensity from each fragment is proportional to the fragment length. METHODS: The isolation of bacterial genomic DNA and digestion by restriction enzymes were performed inside an agarose plug. Rare cutting enzymes were employed to produce a manageable number of DNA fragments. Electroelution was used to move the DNA fragments from the agarose plug into a solution containing polyamines to protect the DNA from shear-induced breakage. The DNA was stained with the bisintercalating dye thiazole orange homodimer and introduced into our ultrasensitive flow cytometer. A histogram of the fluorescence intensities (fingerprint) was constructed. RESULTS: Gram-positive Bacillus globigii and gram-negative bacteria Escherichia coli and Erwinia herbicola were distinguished by the fingerprint pattern of restriction fragments of their genomic DNA. DNA sizes determined by FCM are in good agreement with pulsed-field gel electrophoresis (PFGE) analysis. Flow cytometry requires only picogram quantities of purified DNA and takes less than 10 min for data collection and analysis. When the total sample preparation time is included, the analysis times for PFGE and FCM are similar ( approximately 3 days). CONCLUSIONS: FCM is an attractive technique for the identification of bacterial species. It is more sensitive and potentially much faster than PFGE.  相似文献   

6.
T Woolf  E Lai  M Kronenberg    L Hood 《Nucleic acids research》1988,16(9):3863-3875
A new two-dimensional gel electrophoresis technique has been developed for the mapping of multigene families. Resolution in the first dimension is based on the generation of large size DNA fragments by infrequently-cutting restriction enzymes, and separation of these fragments by field inversion gel (FIG) electrophoresis. A second restriction enzyme digestion is then carried out with the separated DNA fragments in the agarose gel. Standard gel electrophoresis in the second dimension allows one to estimate the number of hybridizing genes contained in each large DNA fragment. We have also developed a novel method to increase the separation, resolution and hybridization signal in the second dimension by condensing the bands from the first dimension into spots. As an example, we have applied these techniques to determine the organization of the murine T-cell receptor gamma locus. The murine gamma gene family was found to be contained on two DNA fragments encompassing 195 kilobases of DNA. The two-dimensional gel electrophoresis method is particularly useful in the analysis of the organization of multigenic families where single copy probes are not readily available, and should extend the potential usefulness of field inversion gel electrophoresis in gene mapping.  相似文献   

7.
The effects of DNA concentration, buffer composition, added "carrier" DNA, and chemical modification of agarose on the electrophoretic separation of DNA restriction fragments in agarose gels were tested. Electrophoretic zones of migrating DNA were found to broaden by trailing as sample load was decreased, and this effect was found to be more pronounced for species of higher molecular weight. As DNA sample load was increased, DNA fragments were found to move faster in the direction of electrophoresis (front forward). Sharp, well-resolved electrophoretic zones were obtained at very low DNA loads only when a high-salt, high-pH, high-EDTA buffer was employed or when "carrier DNA" having a broad and uniform molecular weight distribution was included in the sample. Moreover, DNA in high concentration was found to displace DNA in low concentration from a given gel region. Unmodified agaroses were found to differ only slightly in their effectiveness in retarding DNA fragments at a given agarose concentration. However, hydroxyethylated agarose was much more effective in retarding DNA, at a given gel concentration, than the unmodified agaroses tested. These results show that it is useful to consider the agarose gel matrix as possessing the properties of both a molecular sieve and a chromatographic adsorbent when designing electrophoretic separation techniques for DNA. A model for these separations which includes the effects of DNA-agarose interaction and molecular sieving is discussed.  相似文献   

8.
A rapid and inexpensive method for the electroelution of DNA fragments from agarose gels is described. DNA fragments were separated by agarose gel electrophoresis and visualized by staining with ethidium bromide. Selected DNA fragments were placed into electroeluter tubes capped with dialysis membrane and electroeluted into a small volume of buffer using a conventional horizontal gel electrophoresis apparatus. The method successfully eluted and concentrated DNA fragments with molecular weights ranging from 2.7 to 13.9 MDa in 3 h.  相似文献   

9.
A method for horizontal polyacrylamide slab gel electrophoresis   总被引:1,自引:0,他引:1  
G R Bellomy  M T Record 《BioTechniques》1989,7(1):16, 19-16, 21
We present a simplified method of preparation of polyacrylamide gels which is totally analogous to the procedure now widely used to pour and run horizontal agarose gels. The acrylamide is poured into an open air gel mold consisting of a glass plate with a masking tape border and a comb. It is subsequently run in a submarine horizontal electrophoresis apparatus. The electrophoretic mobility and resolution of DNA fragments obtained in such gels are identical to results obtained with gels poured and run in the vertical configuration. Numerous advantages of horizontal polyacrylamide gel electrophoresis are discussed.  相似文献   

10.
A flow cytometry-based, ultrasensitive fluorescence detection technique is used to size individual DNA fragments up to 167 kb in length. Application of this technology to the sizing of P1 artificial chromosomes (PACs) in both linear and supercoiled forms is described. It is demonstrated that this method is well suited to characterizing PAC/BAC clones and will be very useful for the analysis of large insert libraries. Fluorescence bursts are recorded as individual, dye stained DNA fragments pass through a low power, focused, continuous laser beam. The magnitudes of the fluorescence bursts are linearly proportional to the lengths of the DNA fragments. The histograms of the burst sizes are generated in <3 min with <1 pg of DNA. Results on linear fragments are consistent with those obtained by pulsed-field gel electrophoresis. In comparison with pulsed-field gel electrophoresis, sizing of large DNA fragments by this approach is more accurate, much faster, requires much less DNA, and is independent of the DNA conformation.  相似文献   

11.
The orientation of DNA fragments in the agarose gels   总被引:1,自引:0,他引:1  
A microscopic method of measuring the orientation of nucleic acids in the agarose gels is described. A nucleic acid undergoing electrophoresis is stained with the dye ethidium bromide and is viewed under high magnification with a polarization microscope. A high-numerical-aperture microscope objective is used to illuminate and to collect the fluorescence signal, and therefore the orientation of the minute quantities of nucleic-acid can be measured: in a typical experiment we can detect the orientation of one-tenth of a picogram (10(13)g) of DNA. Polarization properties of the fluorescent light emitted by the separate bands corresponding to different molecular weights of the DNA are examined. A linear dichroism equation relates the measured fluorescence to the mean orientation of the absorption dipole of the ethidium bromide (and therefore DNA) and to the extent to which it is disorganized. As an example, we measured the orientation of phi X174 DNA RF/HaeIII fragments undergoing electrophoresis in a field of 10 V/cm. Ethidium bromide bound to the fragments with an angle of the absorption dipole largely perpendicular to the direction of the electrophoretic current. The dichroism declined as the molecular weight of the fragments decreased which is interpreted as an increase in the degree of disorder for shorter DNA.  相似文献   

12.
The rapid alkaline transfer of high molecular weight DNA from agarose gels to nylon membranes has greatly decreased the time required for setup of Southern transfers. This technique has been used to resolve genomic DNA greater than 1000 base pairs by conventional electrophoresis on 1% agarose gels followed by alkaline transfer to nylon membrane. Now we report that this rapid alkaline method can be used for the transfer of low molecular weight DNA fragments (10 to 1000 base pairs) from NuSieve GTG agarose gels to nylon membrane.  相似文献   

13.
Denatured bacteriophage T5 DNA contains a large number of single-stranded DNA fragments which have been separated by agarose gel electrophoresis and classified as “major” or “minor” species on the basis of their relative abundances (Hayward & Smith, 1972). For further study of these fragments we have centrifuged denatured T5 DNA in CsCl density-gradients in the presence of poly(G). Gel electrophoretic analysis of fractions from these gradients shows that the 37.0 and 13.9 million major fragments of T5+ DNA and the 35.3 and 17.2 million of T5st(O) DNA are found in the high buoyant density regions. The other fragments vary in the extent of their interactions with poly(G) and a minor fragment, which has anomalous electrophoretic properties, exhibits the strongest poly(G) interaction.  相似文献   

14.
The electrophoretic separation of DNA molecules is usually performed in thin slabs of agarose or polyacrylamide gel. However, DNA separations can be achieved more rapidly and efficiently within a microbore fused silica capillary filled with an uncrosslinked polymer solution. An early assumption was that the mechanism of DNA separation in polymer solution(SINGLEBOND)capillary electrophoresis (PS(SINGLEBOND)CE) is the same as that postulated to occur in slab gel electrophoresis, i.e., that entangled polymer chains form a network of "pores" through which the DNA migrates. However, we have demonstrated that large DNA restriction fragments (2.0(SINGLEBOND)23.1 kbp) can be separated by CE in extremely dilute polymer solutions, which contain as little as 6 parts per million [0.0006% (w/w)] of uncrosslinked hydroxyethyl cellulose (HEC) polymers. In such extremely dilute HEC solutions, far below the measured polymer entanglement threshold concentration, pore-based models of DNA electrophoresis do not apply. We propose a transient entanglement coupling mechanism for the electrophoretic separation of DNA in uncrosslinked polymer solutions, which is based on physical polymer/DNA interactions. (c) 1996 John Wiley & Sons, Inc.  相似文献   

15.
The understanding, on a molecular level, of the mechanisms responsible for the improved separation in DNA gel electrophoresis when using modulated electric fields requires detailed information about conformational distribution and dynamics in the DNA/gel system. The orientational order due to electrophoretic migration ("electrophoretic orientation") is an interesting piece of information in this context that can be obtained through linear dichroism spectroscopy [M. Jonsson, B. Akerman, and B. Nordén, (1988) Biopolymers 27, 381-414]. The technique permits measurement of the orientation factor S of DNA (S = 1 corresponds to perfect orientation) within an electrophoretic zone in the gel during the electrophoresis. It is reported that the degree of orientation of T2 DNA [170 kilo base pairs (kpb)] is considerable (S = 0.17 in 1% agarose at 10 V/cm) compared to relatively modest orientations of short fragments found earlier (for 23-kbp DNA, S = 0.03 in 1% agarose at 10 V/cm), showing that large DNA coils are substantially deformed during the migration. Growth and relaxation dynamics of the orientational order of the T2 DNA are also reported, as functions of gel concentration (0.3-2%), electric field strength (0-40 V/cm), and pulse characteristics. The rise profile of the DNA orientation, when applying a constant field, is a nonmonotonic function that displays a pronounced overshoot, followed by a minor undershoot, before it reaches steady-state orientation (after 12 s in 1% agarose, 9 V/cm). The orientational relaxation in absence of field shows a multiexponential decay in a time region of some 10 s, when most of the DNA anisotropy has disappeared. A surprising phenomenon is a memory over minutes of the DNA/gel system to previous pulses: with two consecutive rectangular pulses (of the same polarity), the orientational overshoot and undershoot as a response to the second pulse are significantly reduced compared to the first pulse. The time required to recover 90% of their amplitudes is typically 1200 s (1% agarose, 9 V/cm), which may be compared to the time required to relax 90% of the DNA orientation, which is only 6 s. The major part of the over- and undershoot recovery is thus a reorganization of a system in which DNA is already randomly oriented. The different response amplitudes and relaxation times, including the amplitude and recovery time of the overshoot, of the orientational order of DNA in the electrophoretic gel have been studied as functions of gel concentration and field strength. The results are discussed against relevant theories of polymer dynamics.  相似文献   

16.
Direct agar gel electrophoresis of incubated rat liver nuclei revealed that most of the chromatin is rapidly converted to stable, large fragments, showing identical electrophoretic mobility. Short and long term incubation gave the same results. The analysis of deproteinized DNA under nondenaturing as well as denaturing conditions showed, however, a correlation between the DNA size pattern and the time of incubation. Our data on the persistance of large and uniform in size chromatin fragments despite the presence of cleaved DNA in them may indicate naturally footprinted regions of chromatin, implying most probably some strong ordered interaction of chromatin constituents. It seems that some substantial unknown features of higher order structure of chromatin are preserved in rat liver nuclei isolated and digested under the experimental conditions used.  相似文献   

17.
G W Slater  C Turmel  M Lalande  J Noolandi 《Biopolymers》1989,28(10):1793-1799
We study the effect of electric field intensity and agarose gel concentration on the anomalous electrophoretic mobility recently predicted by the biased reptation model and experimentally observed for linear DNA fragments electrophoresed in continuous electric fields. We show that high fields and low agarose concentrations eliminate the physical mechanism responsible for anomalous DNA mobility and band inversion, in good agreement with theory, thus restoring the monotonic mobility-size relationship necessary for unambiguous interpretation of the results of DNA gel electrophoresis.  相似文献   

18.
Agarose gel electrophoresis is the most effective way of separating DNA fragments of varying sizes ranging from 100 bp to 25 kb1. Agarose is isolated from the seaweed genera Gelidium and Gracilaria, and consists of repeated agarobiose (L- and D-galactose) subunits2. During gelation, agarose polymers associate non-covalently and form a network of bundles whose pore sizes determine a gel''s molecular sieving properties. The use of agarose gel electrophoresis revolutionized the separation of DNA. Prior to the adoption of agarose gels, DNA was primarily separated using sucrose density gradient centrifugation, which only provided an approximation of size. To separate DNA using agarose gel electrophoresis, the DNA is loaded into pre-cast wells in the gel and a current applied. The phosphate backbone of the DNA (and RNA) molecule is negatively charged, therefore when placed in an electric field, DNA fragments will migrate to the positively charged anode. Because DNA has a uniform mass/charge ratio, DNA molecules are separated by size within an agarose gel in a pattern such that the distance traveled is inversely proportional to the log of its molecular weight3. The leading model for DNA movement through an agarose gel is "biased reptation", whereby the leading edge moves forward and pulls the rest of the molecule along4. The rate of migration of a DNA molecule through a gel is determined by the following: 1) size of DNA molecule; 2) agarose concentration; 3) DNA conformation5; 4) voltage applied, 5) presence of ethidium bromide, 6) type of agarose and 7) electrophoresis buffer. After separation, the DNA molecules can be visualized under uv light after staining with an appropriate dye. By following this protocol, students should be able to: 1. Understand the mechanism by which DNA fragments are separated within a gel matrix 2. Understand how conformation of the DNA molecule will determine its mobility through a gel matrix 3. Identify an agarose solution of appropriate concentration for their needs 4. Prepare an agarose gel for electrophoresis of DNA samples 5. Set up the gel electrophoresis apparatus and power supply 6. Select an appropriate voltage for the separation of DNA fragments 7. Understand the mechanism by which ethidium bromide allows for the visualization of DNA bands 8. Determine the sizes of separated DNA fragments    相似文献   

19.
Unexpected loss of genomic DNA from agarose gel plugs   总被引:3,自引:0,他引:3  
R B Fritz  P R Musich 《BioTechniques》1990,9(5):542, 544, 546-542, 544, 550
Intact chromosomal DNAs are routinely prepared by embedding cells in agarose plugs before lysis. The large sizes of the genomic DNAs cause their retention while other macromolecules diffuse into and out of the gel matrix during lysis, washing and restriction cleavage incubations. However, in an analysis of agarose-embedded chromosomal DNAs cleaved with restriction enzymes, fragments larger than 30 kilobases were found to have eluted from the gel plugs. Since loss of fragments from gel plugs may affect qualitative and quantitative interpretations of electrophoretic patterns, an analysis of the diffusion of DNA segments from agarose plugs was performed. The two variables monitored were the time dependence and the DNA fragment size dependence of the diffusion process. The results indicate that small fragments (less than or equal to 2 kilobases) are quickly lost from 1% agarose gel plugs; moreover, significant amounts of large DNA segments (i.e., the 48.5-kilobase lambda phage chromosome) are also lost. In addition to urging caution in the analysis of restriction cleavage data, these observations suggest that intact small organelle genomes and extrachromosomal DNAs also may be lost from genomic DNAs prepared in agarose gel plugs.  相似文献   

20.
Previous electrophoretic separations of megabase (Mb) sized DNA have been achieved in pulsed electric fields, using agarose gel as a matrix. The present study demonstrates separations of Mb sized DNA due to a retardation of migration in proportion to the concentration of uncrosslinked polyacrylamide of 5 x 10(6) molecular weight, using a constant electric field. Potentially, the method should be applicable to large DNA in general, greatly reducing the instrumental complexity of such separations and rendering them compatible with capillary electrophoresis apparatus.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号