首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the simultaneous quantitation of cerivastatin (acid) and its biotransformation products, cerivastatin lactone, M-1 (acid), M-1 lactone, M-23 (acid), M-23 lactone, M-24 (acid) and M-24 lactone, in human serum by high-performance liquid chromatography (LC) with positive ion electrospray tandem mass spectrometry (MS–MS) was developed and validated. The method involves extraction of cerivastatin and its biotransformation products from acidified human serum (0.5 ml) using methyl tert.-butyl ether. The standard curve ranges in human serum were from 0.0100 to 10.0 ng/ml for cerivastatin and cerivastatin lactone, 0.0500 to 10.0 ng/ml for M-1 (acid) and M-1 lactone, 0.100 to 10.0 ng/ml for M-23 (acid) and M-23 lactone, and 0.500 to 10.0 ng/ml for M-24 (acid) and M-24 lactone. The lactone compounds in human serum at room temperature underwent considerable conversion to the corresponding acid compounds after only 4 h. Lowering the serum pH with a pH 5.0 buffer stabilized the lactone compounds for up to 24 h at room temperature. The degree of lactonization of the acid compounds was ≤3.5% and the degree of hydrolysis of the lactone compounds was ≤6.0% during the entire assay procedure. All the eight analytes eluted within 2.0 min and the total run time was only 3.5 min.  相似文献   

2.
An improved gas chromatographic method, involving the use of a wide-bore capillary column, for the determination of trimethadione and its only demethylated metabolite, dimethadione, in human serum is described. The results indicate that both substances and the internal standard (maleinimide) were well separated with no tailing peak. The detection limit was 10 ng/ml for trimethadione and 50 ng/ml for dimethadione. This improved method is reliable in terms of sensitivity, selectivity and reproducibility for the simultaneous determination of both compounds in human serum.  相似文献   

3.
This paper describes an assay for the determination of glyphosate (GLYP), glyphosate metabolites [(aminomethyl) phosphonic acid] (AMPA), and glufosinate (GLUF) in human serum. After protein precipitation using acetonitrile and solid-phase extraction, serum samples were derivatized and analyzed by gas chromatography-mass spectrometry (GC-MS). The assay was linear over a concentration range of 3-100.0 microg/ml for GLYP, AMPA, and GLUF. The overall recoveries for the three compounds were >73%. The intra- and inter-day variations were <15%. Precision and accuracy were 6.4-10.6% and 88.2-103.7%, respectively. The validated method was applied to quantify the GLYP and AMPA content in the serum of a GLYP-poisoned patient. In conclusion, the method was successfully applied for the determination of GLYP and its metabolite AMPA in serum obtained from patient of GLYP-poisoning.  相似文献   

4.
An accurate, sensitive, reproducible, and selective liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for determination of aripiprazole and its main metabolite, OPC-14857, in human plasma was developed and validated. Chromatographic separation was achieved isocratically on a C18 reversed-phase column within 7.5 min. The calibration curve, ranging from 0.1 to 100 ng/ml, was fitted to a 1/y2-weighted linear regression model. The assay showed no significant interference. Lower limit of quantitation (LLOQ) for both analytes was 0.1 ng/ml using 0.4 ml of plasma. Intra- and inter-assay precision and accuracy values for aripiprazole and OPC-14857 were within regulatory limits.  相似文献   

5.
An analytical method for simultaneous determination of benazepril and its active metabolite, benazeprilat, in human plasma by high-performance liquid chromatography/electrospray-mass spectrometry was developed and validated. Rutaecarpine was selected as the internal standard. The separation was achieved on a C(18) column with acetonitrile and aqueous solution (0.1% formic acid) as mobile phase with a gradient mode. The quantification of target compounds was using a selective ionization recording at m/z 425.5 for benazepril, m/z 397.5 for benzeprilat and m/z 288.3 for rutaecarpine. The correlation coefficients of the calibration curves were better than 0.992 (n = 6), in the range of 6.67-666.67 ng/ml for benazepril and benazeprilat. The inter- and intra-day accuracy, precision, linear range had been investigated in detail. The method can be used to assess the bioavailability and pharmacokinetics of the drug.  相似文献   

6.
An analytical method for simultaneous determination of erythromycin propionate and its active metabolite, erythromycin base, in human plasma by high-performance liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS) was developed and validated. Roxithromycin was selected as the internal standard. The samples were directly injected after simple deproteinized procedure only. The separation was achieved on a Johnson Spherigel analytical column packed with 5 microm C18 silica, employing acetonitrile -0.1% formic acid aqueous solution (50:50) as mobile phase. The quantification of target compounds was obtained by using a selected ion monitoring (SIM) at m/z 790.7 for erythromycin propionate, m/z 734.7 for erythromycin base and m/z 837.8 for roxithromycin. The correlation coefficients of the calibration curves were better than 0.997 (n=6), in the ranges from 2 ng/ml to 1 microg/ml, and from 1 to 10 microg/ml for erythromycin propionate and base. The method can provide the necessary sensitivity, precision and accuracy to allow the simultaneous determination of both compounds in a patient's plasma following a single administration of erythromycin stinoprate capsule (500 mg erythromycin base equivalent).  相似文献   

7.
A sensitive and selective method is described for the determination of artemether and its active dihydroartemisinin metabolite in human plasma using artemisinin as internal standard. The method consists of a liquid-liquid extraction with subsequent evaporation of the supernatant to dryness followed by the analysis of the reconstituted sample by liquid chromatography-mass spectrometry (LC-MS) in single ion monitoring mode using atmospheric pressure chemical ionization (APCI) as an interface. Chromatography was performed on a C(18) reversed-phase column using acetonitrile-glacial acetic acid 0.1% (66:34) as a mobile phase. The method was fully validated over a concentration range of 5-200 ng/ml using 0.5 ml of human plasma per assay. Stability assessment was also included. The method was applied to the quantification of artemether and its metabolite in human plasma of healthy volunteers participating in pharmacokinetic drug-drug interaction studies.  相似文献   

8.
Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast-one run could be performed within less than 10 min (CE-UV method) and 2.5 min (CE-LIF method), respectively. Both assays were fully validated and applied to urine samples from a human volunteer. The results of the application of the CE-LIF method to human urine samples are presented in this publication.  相似文献   

9.
A sensitive, rapid and selective liquid chromatography-positive electrospray ionization tandem mass spectrometry (LC-(ESI+)-MS-MS) method has been developed and validated for the simultaneous quantification of beclomethasone dipropionate (BDP) and its active metabolite, beclomethasone 17-monopropionate (17-BMP) in rat plasma and different tissues using fluticasone propionate (FP) as the internal standard. The method was validated over a linear range from 0.05 to 5 ng/ml for both analytes. A solid-phase extraction procedure was used for plasma samples and a liquid-liquid extraction procedure for tissues samples (lung, liver and kidney). The between-day and within-day coefficients of variation for all compounds were 相似文献   

10.
Quantitative analysis of therapeutic compounds and their metabolites in biological matrix (such as plasma, serum or urine) nowadays requires sensitive and selective methods to allow the determination of concentrations in the ng/ml range. A new on-line LC–MS–MS method using atmospheric pressure chemical ionisation (APCI) as interface for the simultaneous determination of nifedipine (NIF) and its metabolite in human plasma, dehydronifedipine (DNIF) has been developed. The compounds were extracted from plasma using solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with phenyl modified silica was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol and water. The liquid chromatographic (LC) separation of NIF and DNIF was achieved on a RP-18 stationary phase (4 μm). The mobile phase consisted of methanol–50 mM ammonium acetate solution (50:50, v/v). The LC was then coupled to tandem mass spectrometry with an APCI interface in the positive ion mode.

The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 95±2% and 95±4% for NIF and DNIF, respectively. The method was found to be linear in the 0.5–100 ng/ml concentration range for the two analytes (r2=0.999 for both NIF and DNIF). The mean R.S.D. values for repeatability and intermediate precision were 2.9 and 3.0% for NIF and 2.2–4.7% for the metabolite.The method developed was successfully used to investigate the plasma concentration of NIF and DNIF in the pharmacokinetic studies.  相似文献   


11.
A high throughput bioanalytical method based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS), has been developed for the estimation of perindopril and its metabolite perindoprilat, an angiotensin-converting enzyme inhibitor in human plasma. Ramipril was used as internal standard (IS). The extraction of perindopril, perindoprilat and ramipril from the plasma involved treatment with phosphoric acid followed by solid phase extraction (SPE) using hydrophilic lipophilic balance HLB cartridge. The SPE eluate without drying were analyzed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the negative ion and selective reaction monitoring (SRM) acquisition mode to quantify perindopril and perindoprilat in human plasma. The total chromatographic run time was 1.5 min with retention time for perindopril, perindoprilat and ramipril at 0.33, 0.35 and 0.30 min. The developed method was validated in human plasma matrix, with a sensitivity of 0.5 ng/ml (CV, 7.67%) for perindopril and 0.3 ng/ml (CV, 4.94%) for perindoprilat. This method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect especially because the pattern of elution of all the analytes appears as flow injection elution. Sample preparation by this method yielded extremely clean extracts with very good and consistent mean recoveries; 78.29% for perindopril, 76.32% for perindoprilat and 77.72% for IS. The response of the LC-MS/MS method for perindopril and perindoprilat was linear over the range 0.5-350.0 ng/ml for perindopril and 0.3-40 ng/ml for perindoprilat with correlation coefficient, r>/=0.9998 and 0.9996, respectively. The method was successfully applied for bioequivalence studies in human subjects samples with 4 mg immediate release (IR) formulations.  相似文献   

12.
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI/MS) method for simultaneous stereoselective analysis of venlafaxine (VEN) and its major metabolite O-desmethylvenlafaxine (ODV) enantiomers in human plasma has been developed and validated. Chiral chromatography is performed on the CHRIOBIOTIC V (5 microm, 250 mm x 4.6 mm) column with mobile phase constituted of 30 mmol/l ammonium acetate-methanol (15:85, pH 6.0) at a flow rate of 1.0 ml/min and a postcolumn splitting ratio of 3:1. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and detected using the selected ion recording (SIR) mode. Calibration curves obtained from spiked plasma were linear in the range of 5.0-400 ng/ml for S-(+)-VEN and R-(-)-VEN, 4.0-280 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively, with linear correlation coefficient all above 0.999. The average extraction recoveries for all the four analytes were above 76%. The methodology recoveries were higher than 92%. The limit of detection were 1.0 ng/ml for S-(+)-VEN and R-(-)-VEN, 1.5 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively. The intra- and inter-day variation coefficients were less than 9%.  相似文献   

13.
A fast and robust liquid chromatography-mass spectrometry (LC-MS-MS) method has been developed for simultaneous quantitation of the angiotensin-converting enzyme (ACE) inhibitor, ramipril and its metabolite ramiprilat in human plasma. The method involves a solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables a detection limit at sub-nanogram levels. The proposed method has been validated with a linear range of 0.5-250 ng/ml for both ramipril and ramiprilat. The overall recoveries for ramipril and ramiprilat were 88.7 and 101.8%, respectively.  相似文献   

14.
A rapid, sensitive, and highly selective liquid chromatography-tandem mass spectrometry method was developed and validated for simultaneous determination of enalapril and its major active metabolite enalaprilat in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax Extend-C(18) column, and detected by tandem mass spectrometry with a Turbo IonSpray ionization interface. The method has a lower limit of quantification (LLOQ) of 0.1 ng/ml for both enalapril and enalaprilat. The chromatographic run time was approximately 3.5 min. The standard calibration curves for both enalapril and enalaprilat were linear in the concentration ranges of 0.10-100.0 ng/ml in human plasma. The intra- and inter-run precisions, expressed as the relative standard deviation (R.S.D.), were less than 7.7 and 7.8%, determined from QC samples for enalapril and enalaprilat, and accuracy was within +/-3.9 and +/-2.7% in terms of relative error, respectively. The method was successfully applied for the evaluation of the pharmacokinetics of enalapril and enalaprilat in 20 volunteers after an oral dose of 10 mg enalapril maleate.  相似文献   

15.
Since the first entry of risperidone on to the market in the early 1990s, investigation of the pharmacokinetic behaviour of the compound for which the availability of a bioanalytical method was a condition sine qua non, has received considerable attention. Most of the published methods, however, did not reach the level of sensitivity and selectivity which can be obtained today since the evolution of liquid chromatography-tandem mass spectrometry (LC-MS-MS) towards a routine technique in the bioanalytical laboratory. Therefore, we developed and validated a new LC-MS-MS method for the determination of risperidone and its active metabolite 9-hydroxyrisperidone in human plasma. This paper describes in detail the bioanalytical procedure and summarizes the validation results obtained. In addition, it focuses on the pitfalls one might encounter when developing similar assays. Despite the particular physicochemical characteristics of risperidone and 9-hydroxyrisperidone, the LC-MS-MS method enabled the quantification of both compounds down to 0.1 ng/ml. The method uses a sample preparation step by solid-phase extraction at pH 6 using a mixed-mode phase. In a short chromatographic run, separation of 9-hydroxyrisperidone from the minor metabolite 7-hydroxyrisperidone is achieved. Detection takes place by (turbo)ionspray tandem mass spectrometry in the positive ion mode. The validated concentration range is from 0.100 to 250 ng/ml, using 500 microliter of sample, with accuracy (bias) and precision (coefficient of variation) being below 15%. Although new developments in equipment will allow us to further improve and speed up the method, the assay reported can be used as a routine method to support a wide range of pharmacokinetic studies.  相似文献   

16.
Aripiprazole is a novel antipsychotic drug for the treatment of schizophrenia and schizoaffective disorders. In this study, a new method using gas chromatography-mass spectrometry (GC-MS) was developed and validated for the detection of aripiprazole and its main metabolite, dehydroaripiprazole, in plasma. Blood samples from seven psychiatric patients treated with aripiprazole (10-20 mg/day) underwent a solid-phase extraction (SPE) and N-methyl-N-trimethylsilytrifluoroacetamide (MSTFA) derivatization. The characteristic ions of mass spectra for aripiprazole and dehydroaripiprazole were m/z 306, 292, 218 and 304, 290, 218, respectively. Extraction recoveries from this method were 75.4% (n=5) for aripiprazole and 102.3% (n=5) for dehydroaripiprazole. The calibration curves of aripiprazole and dehydroaripiprazole were linear from 16 to 500 ng/ml (r(2)=0.999) and 8 to 250 ng/ml (r(2)=0.999), respectively. The respective limits of quantification (LOQs) for aripiprazole and dehydroaripiprazole evaluated in 0.5 ml of serum were 14.4 ng/ml and 6.9 ng/ml. Intra-assay and interassay precision and accuracy were within acceptable ranges. In this study, we also found that the mean trough concentrations in plasma at steady-state were 128.9 microg/l for aripiprazole and 30.1 microg/l for dehydroaripiprazole.  相似文献   

17.
A rapid and specific HPLC method has been developed and validated for simultaneous determination of clobazam, the anticonvulsant agent, and its major metabolite in human plasma. The sample preparation was a liquid-liquid extraction with tuloene yielding almost near 100% recoveries of two compounds. Chromatographic separation was achieved with a Chromolith Performance RP-18e 100 mm x 4.6mm column, using a mixture of a phosphate buffer (pH 3.5; 10mM)-acetonitrile (70:30, v/v), in isocratic mode at 2 ml/min at a detection wave-length of 228 nm. The calibration curves were linear (r(2)>0.998) in the concentration range of 5-450 ng ml(-1). The lower limit of quantification was 5 ng ml(-1) for two compounds studied. The within- and between-day precisions in the measurement of QC samples at four tested concentrations were in the range of 0.89-9.1% and 2.1-10.1% R.S.D., respectively. The developed procedure was applied to assess the pharmacokinetics of clobazam and its major metabolite following administration of a single 10mg oral dose of clobazam to healthy volunteers.  相似文献   

18.
We describe a liquid chromatography-electrospray ionisation tandem mass spectrometry method for the qualitative and quantitative determination of the secoiridoid oleuropein and its bioactive metabolite hydroxytyrosol in rat plasma and urine. Samples were prepared by liquid-liquid extraction using ethyl acetate with a recovery for both compounds of about 100% in plasma and about 60% in urine. The chromatographic separation was performed with a RP-ODS column using a water-acetonitrile linear gradient. The calibration curve was linear for both biophenols over the range 2.5-1000 ng/ml (LOD 1.25 ng/ml) for plasma and 5-1000 ng/ml (LOD 2.5 ng/ml) for urine. Plasma concentrations of oleuropein and hydroxytyrosol were measured after oral administration of a single dose (100 mg/kg) of oleuropein. Analysis of treated rat plasma showed the presence of unmodified oleuropein, reaching a peak value of 200 ng/ml within 2 h, with a small amount of hydroxytyrosol, whereas in urine, both compounds were mainly found as glucuronides.  相似文献   

19.
A liquid chromatography-tandem mass spectrometry method was developed for the analysis of sildenafil (SIL) and its metabolite desmethylsildenafil (DMS) in human plasma. Samples were accurately transferred to 96-well plates using a liquid handler (Multiprobe II). Solid-phase extraction was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using a C8 and cation-exchange mixed-mode sorbent. The extract was injected onto a silica column with an aqueous-organic mobile phase, a combination that was novel for improving the method sensitivity. The low limit of quantitation was 1.0 ng/ml for both SIL and DMS. The method was validated to meet the criteria of current industrial guidance for quantitative bioanalytical methods.  相似文献   

20.
A simple, sensitive and specific HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the simultaneous quantification of tiloronoxim and its major active metabolite, tilorone, in human urine. The analytes, together with metoprolol, which was employed as an internal standard (IS), were extracted with a mixture solvent of chloroform/ethyl ether (1/2, v/v). The chromatographic separation was performed on a narrow-bore reversed phase HPLC column with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). The API 3,000 mass spectrometer was equipped with a TurboIonSpray interface and was operated on positive-ion, multiple reaction-monitoring (MRM) mode. The mass transitions monitored were m/z 426.3-->100.0, m/z 411.3-->100.0 and m/z 268.3-->116.1 for tiloronoxim, tilorone and the IS, respectively. The assay exhibited a linear dynamic range of 1-100 ng/ml for both tiloronoxim and tilorone based on the analysis of 0.2 ml aliquots of urine. The lower limit of quantification was 1 ng/ml for both compounds. Acceptable precision and accuracies were obtained for concentrations over the standard curve ranges. Run time of 8 min for each injection made it possible to analyze a high throughput of urine samples. The assay has been successfully used to analyze human urine samples from healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏