首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A tryptic digest generated from Xenopus laevis fertilized embryos was fractionated by RPLC. One set of 30 fractions was analyzed by 100‐min CZE‐ESI‐MS/MS separations (50 h total instrument time), and a second set of 15 fractions was analyzed by 3‐h UPLC‐ESI‐MS/MS separations (45 h total instrument time). CZE‐MS/MS produced 70% as many protein IDs (4134 versus 5787) and 60% as many peptide IDs (22 535 versus 36 848) as UPLC‐MS/MS with similar instrument time (50 h versus 45 h) but with 50 times smaller total consumed sample amount (1.5 μg versus 75 μg). Surprisingly, CZE generated peaks that were 25% more intense than UPLC for peptides that were identified by both techniques, despite the 50‐fold lower loading amount; this high sensitivity reflects the efficient ionization produced by the electrokinetically pumped nanospray interface used in CZE. This report is the first comparison of CZE‐MS/MS and UPLC‐MS/MS for large‐scale eukaryotic proteomic analysis. The numbers of protein and peptide identifications produced by CZE‐ESI‐MS/MS approach those produced by UPLC‐MS/MS, but with nearly two orders of magnitude lower sample amounts.  相似文献   

3.
The use of nLC-ESI-MS/MS in shotgun proteomics experiments and GeLC-MS/MS analysis is well accepted and routinely available in most proteomics laboratories. However, the same cannot be said for nLC-MALDI MS/MS, which has yet to experience such widespread acceptance, despite the fact that the MALDI technology offers several critical advantages over ESI. As an illustration, in an analysis of moderately complex sample of E. coli proteins, the use MALDI in addition to ESI in GeLC-MS/MS resulted in a 16% average increase in protein identifications, while with more complex samples the number of additional protein identifications increased by an average of 45%. The size of the unique peptides identified by MALDI was, on average, 25% larger than the unique peptides identified by ESI, and they were found to be slightly more hydrophilic. The insensitivity of MALDI to the presence of ionization suppression agents was shown to be a significant advantage, suggesting it be used as a complement to ESI when ion suppression is a possibility. Furthermore, the higher resolution of the TOF/TOF instrument improved the sensitivity, accuracy, and precision of the data over that obtained using only ESI-based iTRAQ experiments using a linear ion trap. Nevertheless, accurate data can be generated with either instrument. These results demonstrate that coupling nanoLC with both ESI and MALDI ionization interfaces improves proteome coverage, reduces the deleterious effects of ionization suppression agents, and improves quantitation, particularly in complex samples.  相似文献   

4.
Biniossek ML  Schilling O 《Proteomics》2012,12(9):1303-1309
Peptide sequences lacking basic residues (arginine, lysine, or histidine, referred to as "base-less") are of particular importance in proteomic experiments targeting protein C-termini or employing nontryptic proteases such as GluC or chymotrypsin. We demonstrate enhanced identification of base-less peptides by focused analysis of singly charged precursors in liquid chromatography (LC) electrospray ionization (ESI) tandem mass spectrometry (MS/MS). Singly charged precursors are often excluded from fragmentation and sequence analysis in LC-MS/MS. We generated different pools of base-less and base-containing peptides by tryptic and nontryptic digestion of bacterial proteomes. Focused LC-MS/MS analysis of singly charged precursor ions yielded predominantly base-less peptide identifications. Similar numbers of base-less peptides were identified by LC-MS/M Sanalysis targeting multiply charged precursors. There was little redundancy between the base-less sequences derived by both MS/MS schemes. In the present experimental outcome, additional LC-MS/MS analysis of singly charged precursors substantially increased the identification rate of base-less sequences derived from multiply charged precursors. In conclusion, LC-MS/MS based identification of base-less peptides is substantially enhanced by additional focused analysis of singly charged precursors.  相似文献   

5.
Modern nano‐HPLC systems are capable of extremely precise control of solvent gradients, allowing high‐resolution separation of peptides. Most proteomics laboratories use a simple linear analytical gradient for nano‐LC‐MS/MS experiments, though recent evidence indicates that optimized non‐linear gradients result in increased peptide and protein identifications from cell lysates. In concurrent work, we examined non‐linear gradients for the analysis of samples fractionated at the peptide level, where the distribution of peptide retention times often varies by fraction. We hypothesized that greater coverage of these samples could be achieved using per‐fraction optimized gradients. We demonstrate that the optimized gradients improve the distribution of peptides throughout the analysis. Using previous generation MS instrumentation, a considerable gain in peptide and protein identifications can be realized. With current MS platforms that have faster electronics and achieve shorter duty cycle, the improvement in identifications is smaller. Our gradient optimization method has been implemented in a simple graphical tool (GOAT) that is MS‐vendor independent, does not require peptide ID input, and is freely available for non‐commercial use at http://proteomics.swmed.edu/goat/  相似文献   

6.
The Mascot score (M-score) is one of the conventional validity measures in data base identification of peptides and proteins by MS/MS data. Although tremendously useful, M-score has a number of limitations. For the same MS/MS data, M-score may change if the protein data base is expanded. A low M-value may not necessarily mean poor match but rather poor MS/MS quality. In addition M-score does not fully utilize the advantage of combined use of complementary fragmentation techniques collisionally activated dissociation (CAD) and electron capture dissociation (ECD). To address these issues, a new data base-independent scoring method (S-score) was designed that is based on the maximum length of the peptide sequence tag provided by the combined CAD and ECD data. The quality of MS/MS spectra assessed by S-score allows poor data (39% of all MS/MS spectra) to be filtered out before the data base search, speeding up the data analysis and eliminating a major source of false positive identifications. Spectra with below threshold M-scores (poor matches) but high S-scores are validated. Spectra with zero M-score (no data base match) but high S-score are classified as belonging to modified sequences. As an extension of S-score, an extremely reliable sequence tag was developed based on complementary fragments simultaneously appearing in CAD and ECD spectra. Comparison of this tag with the data base-derived sequence gives the most reliable peptide identification validation to date. The combined use of M- and S-scoring provides positive sequence identification from >25% of all MS/MS data, a 40% improvement over traditional M-scoring performed on the same Fourier transform MS instrumentation. The number of proteins reliably identified from Escherichia coli cell lysate hereby increased by 29% compared with the traditional M-score approach. Finally S-scoring provides a quantitative measure of the quality of fragmentation techniques such as the minimum abundance of the precursor ion, the MS/MS of which gives the threshold S-score value of 2.  相似文献   

7.
iTRAQ reagents allow the simultaneous multiplex identification and quantification of a large number of proteins. Success depends on effective peptide fragmentation in order to generate both peptide sequence ions (higher mass region, 150–2200 m/z) and reporter ions (low mass region, 113–121 m/z) for protein identification and relative quantification, respectively. After collision‐induced dissociation, the key requirements to achieve a good balance between the high and low m/z ions are effective ion transmission and detection across the MS/MS mass range, since the ion transmission of the higher m/z range competes with that of the low m/z range. This study describes an analytical strategy for the implementation of iTRAQ on maXis UHR‐Qq‐ToF instruments, and discusses the impact of adjusting the MS/MS ion transmission parameters on the quality of the overall data sets. A technical discussion highlights a number of maXis‐specific parameters, their impact of quantification and identification, and their cross‐interactions.  相似文献   

8.
High‐resolution MS/MS spectra of peptides can be deisotoped to identify monoisotopic masses of peptide fragments. The use of such masses should improve protein identification rates. However, deisotoping is not universally used and its benefits have not been fully explored. Here, MS2‐Deisotoper, a tool for use prior to database search, is used to identify monoisotopic peaks in centroided MS/MS spectra. MS2‐Deisotoper works by comparing the mass and relative intensity of each peptide fragment peak to every other peak of greater mass, and by applying a set of rules concerning mass and intensity differences. After comprehensive parameter optimization, it is shown that MS2‐Deisotoper can improve the number of peptide spectrum matches (PSMs) identified by up to 8.2% and proteins by up to 2.8%. It is effective with SILAC and non‐SILAC MS/MS data. The identification of unique peptide sequences is also improved, increasing the number of human proteoforms by 3.7%. Detailed investigation of results shows that deisotoping increases Mascot ion scores, improves FDR estimation for PSMs, and leads to greater protein sequence coverage. At a peptide level, it is found that the efficacy of deisotoping is affected by peptide mass and charge. MS2‐Deisotoper can be used via a user interface or as a command‐line tool.  相似文献   

9.
The peptide‐based quantitation accuracy and precision of LC‐ESI (QSTAR Elite) and LC‐MALDI (4800 MALDI TOF/TOF) were compared by analyzing identical Escherichia coli tryptic digests containing iTRAQ‐labeled peptides of defined abundances (1:1, 2.5:1, 5:1, and 10:1). Only 51.4% of QSTAR spectra were used for quantitation by ProteinPilot Software versus 66.7% of LC‐MALDI spectra. The average protein sequence coverages for LC‐ESI and LC‐MALDI were 24.0 and 18.2% (14.9 and 8.4 peptides per protein), respectively. The iTRAQ‐based expression ratios determined by ProteinPilot from the 57 467 ESI‐MS/MS and 26 085 MALDI‐MS/MS spectra were analyzed for measurement accuracy and reproducibility. When the relative abundances of peptides within a sample were increased from 1:1 to 10:1, the mean ratios calculated on both instruments differed by only 0.7–6.7% between platforms. In the 10:1 experiment, up to 64.7% of iTRAQ ratios from LC‐ESI MS/MS spectra failed S/N thresholds and were excluded from quantitation, while only 0.1% of the equivalent LC‐MALDI iTRAQ ratios were rejected. Re‐analysis of an archived LC‐MALDI sample set stored for 5 months generated 3715 MS/MS spectra for quantitation, compared with 3845 acquired originally, and the average ratios differed by only 3.1%. Overall, MS/MS‐based peptide quantitation performance of offline LC‐MALDI was comparable with on‐line LC‐ESI, which required threefold less time. However, offline LC‐MALDI allows the re‐analysis of archived HPLC‐separated samples.  相似文献   

10.
Cocoa seed storage proteins play an important role in flavour development as aroma precursors are formed from their degradation during fermentation. Major proteins in the beans of Theobroma cacao are the storage proteins belonging to the vicilin and albumin classes. Although both these classes of proteins have been extensively characterized, there is still limited information on the expression and abundance of other proteins present in cocoa beans. This work is the first attempt to characterize the whole cocoa bean proteome by nano‐UHPLC‐ESI MS/MS analysis using tryptic digests of cocoa bean protein extracts. The results of this analysis show that >1000 proteins could be identified using a species‐specific Theobroma cacao database. The majority of the identified proteins were involved with metabolism and energy. Additionally, a significant number of the identified proteins were linked to protein synthesis and processing. Several proteins were also involved with plant response to stress conditions and defence. Albumin and vicilin storage proteins showed the highest intensity values among all detected proteins, although only seven entries were identified as storage proteins. A comparison of MS/MS data searches carried out against larger non‐specific databases confirmed that using a species‐specific database can increase the number of identified proteins, and at the same time reduce the number of false positives. The results of this work will be useful in developing tools that can allow the comparison of the proteomic profile of cocoa beans from different genotypes and geographic origins. Data are available via ProteomeXchange with identifier PXD005586.  相似文献   

11.
12.
A thorough understanding of the fragmentation processes in MS/MS can be a powerful tool in assessing the resulting peptide and protein identifications. We here present the freely available, open‐source FragmentationAnalyzer tool ( http://fragmentation‐analyzer.googlecode.com ) that makes it straightforward to analyze large MS/MS data sets for specific types of identified peptides, using a common set of peptide properties. This enables the detection of fragmentation pattern nuances related to specific instruments or due to the presence of post‐translational modifications.  相似文献   

13.
Use of the 4‐pyridylmethyl ester group for side‐chain protection of glutamic acid residues in solid‐phase peptide synthesis enables switching of the charge state of a peptide from negative to positive, thus making detection by positive ion mode ESI‐MS possible. The pyridylmethyl ester moiety is readily removed from peptides in high yield by hydrogenation. Combining the 4‐pyridylmethyl ester protecting group with benzyl ester protection reduces the number of the former needed to produce a net positive charge and allows for purification by RP HPLC. This protecting group is useful in the synthesis of highly acidic peptide sequences, which are often beset by problems with purification by standard RP HPLC and characterization by ESI‐MS. Copyright © 2014 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

14.
Candidate protein biomarker discovery by full automatic integration of Orbitrap full MS1 spectral peptide profiling and X!Tandem MS2 peptide sequencing is investigated by analyzing mass spectra from brain tumor samples using Peptrix. Potential protein candidate biomarkers found for angiogenesis are compared with those previously reported in the literature and obtained from previous Fourier transform ion cyclotron resonance (FT-ICR) peptide profiling. Lower mass accuracy of peptide masses measured by Orbitrap compared to those measured by FT-ICR is compensated by the larger number of detected masses separated by liquid chromatography (LC), which can be directly linked to protein identifications. The number of peptide sequences divided by the number of unique sequences is 9248/6911  1.3. Peptide sequences appear 1.3 times redundant per up-regulated protein on average in the peptide profile matrix, and do not seem always up-regulated due to tailing in LC retention time (40%), modifications (40%) and mass determination errors (20%). Significantly up-regulated proteins found by integration of X!Tandem are described in the literature as tumor markers and some are linked to angiogenesis. New potential biomarkers are found, but need to be validated independently. Eventually more proteins could be found by actively involving MS2 sequence information in the creation of the MS1 peptide profile matrix.  相似文献   

15.
For data‐independent acquisition by means of sequential window acquisition of all theoretical fragment ion spectra (SWATH), a reference library of data‐dependent acquisition (DDA) runs is typically used to correlate the quantitative data from the fragment ion spectra with peptide identifications. The quality and coverage of such a reference library is therefore essential when processing SWATH data. In general, library sizes can be increased by reducing the impact of DDA precursor selection with replicate runs or fractionation. However, these strategies can affect the match between the library and SWATH measurement, and thus larger library sizes do not necessarily correspond to improved SWATH quantification. Here, three fractionation strategies to increase local library size were compared to standard library building using replicate DDA injection: protein SDS‐PAGE fractionation, peptide high‐pH RP‐HPLC fractionation and MS‐acquisition gas phase fractionation. The impact of these libraries on SWATH performance was evaluated in terms of the number of extracted peptides and proteins, the match quality of the peptides and the extraction reproducibility of the transitions. These analyses were conducted using the hydrophilic proteome of differentiating human embryonic stem cells. Our results show that SWATH quantitative results and interpretations are affected by choice of fractionation technique. Data are available via ProteomeXchange with identifier PXD006190.  相似文献   

16.
Kalli A  Hess S 《Proteomics》2012,12(1):21-31
The success of a shotgun proteomic experiment relies heavily on the performance and optimization of both the LC and the MS systems. Despite this, little consideration has, so far, been given to the importance of evaluating and optimizing the MS instrument settings during data‐dependent acquisition mode. Moreover, during data‐dependent acquisition, the users have to decide and choose among various MS parameters and settings, making a successful analysis even more challenging. We have systematically investigated and evaluated the effect of enabling and disabling the preview mode for FTMS scan, the number of microscans per MS/MS scan, the number of MS/MS events, the maximum ion injection time for MS/MS, and the automatic gain control target value for MS and MS/MS events on protein and peptide identification rates on an LTQ‐Orbitrap using the Saccharomyces cerevisiae proteome. Our investigations aimed to assess the significance of each MS parameter to improve proteome analysis and coverage. We observed that higher identification rates were obtained at lower ion injection times i.e. 50–150 ms, by performing one microscan and 12–15 MS/MS events. In terms of ion population, optimal automatic gain control target values were at 5×105–1×106 ions for MS and 3×103–1×104 ions for MS/MS. The preview mode scan had a minimal effect on identification rates. Using optimized MS settings, we identified 1038 (±2.3%) protein groups with a minimum of two peptide identifications and an estimated false discovery rate of ~1% at both peptide and protein level in a 160‐min LC‐MS/MS analysis.  相似文献   

17.
美洲大蠊主要变应原蛋白的质谱鉴定与分析   总被引:3,自引:1,他引:2  
为了建立美洲大蠊Periplaneta americana变应原蛋白的质谱鉴定方法,我们将美洲大蠊粗浸液通过DEAE-52离子交换层析、Sephacryl S-200凝胶过滤层析等分离步骤得到纯化的74 kD蛋白,对纯化前后的该74 kD蛋白分别进行SDS-PAGE及凝胶内胰酶酶切,再经液相色谱-电喷雾-串联质谱(HPLC-ESI-MS/MS)在线联机分析,所得质谱数据进入网站(http://www.matrixscience.com)进行Mascot检索比对。通过对两者质谱鉴定结果的比较来评估美洲大蠊天然主要变应原蛋白的纯化效果。结果表明,纯化蛋白经HPLC-ESI-MS/MS鉴定是美洲大蠊主要变应原蛋白;离子交换层析等纯化步骤可以去除同一分子量的杂蛋白(如卵黄原蛋白),从而获得较好的鉴定结果。我们首次成功地运用质谱建立起变应原蛋白的新鉴定方法。  相似文献   

18.
We introduce the computer tool “Know Your Samples” (KYSS) for assessment and visualisation of large scale proteomics datasets, obtained by mass spectrometry (MS) experiments. KYSS facilitates the evaluation of sample preparation protocols, LC peptide separation, and MS and MS/MS performance by monitoring the number of missed cleavages, precursor ion charge states, number of protein identifications and peptide mass error in experiments. KYSS generates several different protein profiles based on protein abundances, and allows for comparative analysis of multiple experiments. KYSS was adapted for blood plasma proteomics and provides concentrations of identified plasma proteins. We demonstrate the utility of the KYSS tool for MS based proteome analysis of blood plasma and for assessment of hydrogel particles for depletion of abundant proteins in plasma. The KYSS software is open source and is freely available at http://kyssproject.github.io/.  相似文献   

19.
Many biologically relevant glycoproteins need to be separated on 1D‐ or 2D‐gels prior to analysis and are available in picomole amounts. Therefore, it is important to have optimized methods to unravel the glycome that combine in‐gel digestions with MALDI‐TOF‐MS. In this technical report, we investigated how the detection of in‐gel released N‐glycans could be improved by MALDI‐TOF‐MS. First, an AnchorChip target was tested and compared to ground steel target using several reference oligosaccharides. The highest signals were obtained with an AnchorChip target and D‐arabinosazone as the matrix; a LOD of 1.3 to 10 fmol was attained. Then, the effect of octyl‐β‐glucopyranoside, a nonionic detergent, was studied during in‐gel peptide‐N4‐(acetyl‐ß‐glucosaminyl) asparagine amidase F digestion of standard glycoproteins and during glycan extraction. Octyl‐β‐glucopyranoside increased the intensity and the amount of detected neutral as well as acidic N‐glycans. A LOD of under 7 pmol glycoprotein could be achieved.  相似文献   

20.
Mass spectrometers equipped with matrix‐assisted laser desorption/ionization (MALDI‐MS) require frequent multipoint calibration to obtain good mass accuracy over a wide mass range and across large numbers of samples. In this study, we introduce a new synthetic peptide mass calibration standard termed PAS‐cal tailored for MALDI‐MS based bottom‐up proteomics. This standard consists of 30 peptides between 8 and 37 amino acids long and each constructed to contain repetitive sequences of Pro, Ala and Ser as well as one C‐terminal arginine residue. MALDI spectra thus cover a mass range between 750 and 3200 m/z in MS mode and between 100 and 3200 m/z in MS/MS mode. Our results show that multipoint calibration of MS spectra using PAS‐cal peptides compares well to current commercial reagents for protein identification by PMF. Calibration of tandem mass spectra from LC‐MALDI experiments using the longest peptide, PAS‐cal37, resulted in smaller fragment ion mass errors, more matching fragment ions and more protein and peptide identifications compared to commercial standards, making the PAS‐cal standard generically useful for bottom‐up proteomics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号