首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到3条相似文献,搜索用时 0 毫秒
1.
A simple, sensitive, and low-cost immunosensor was designed for the detection of digoxin through core–shell gold coated magnetic nanoparticles (Fe3O4-Au-NPs) as an electrochemical label. Having had such a large potential for a variety of applications, Fe3O4-Au-NPs have attracted a considerable attention and are actively investigated recently. Digoxin is a cardiac glycoside which, at high level, can indicate an increased risk of toxicity. This new competitive electrochemical immunosensor was developed based on antigen–antibody reaction employing antigen (Ag) labeled Fe3O4-Au-NPs and PVA modified screen-printed carbon electrode surface in order to detect the serum digoxin. The structures of Fe3O4-Au-NPs were studied by transmission electron microscopy, X-ray diffraction and Fourier transformed infrared spectroscopy. Cyclic voltammetry and differential pulse voltammetry (DPV) were employed to determine the physicochemical and electrochemical properties of immunosensor. DPV was employed for quantitative detection of digoxin in biological samples. The developed immunosensor was capable to detect digoxin in the range from 0.5 to 5 ng mL?1, with a detection limit as low as 0.05 ng mL?1. The proposed method represented acceptable reproducibility, stability, and reliability for the rapid detection of digoxin in serum samples.  相似文献   

2.
An extensive survey of radioimmunoassay calibration data for prednisolone, prednisone and digoxin indicated that the common practice of preparing calibration curves with individual subject's pre-dose plasma or serum, and using this to estimate unknown concentrations for the same subject, is not supported by statistical considerations. Preparation of calibration plots from pooled data is better because this introduces less bias in estimated concentrations. Such a method also saves a great deal of time, since it is not necessary to repeat the calibration procedure each time “unknowns” are being assayed. The data suggest that there is no optimum calibration plot for all radioimmunoassays. Rather, each antibody-drug combination should be investigated thoroughly to determine the best calibration plot for the particular combination. We found that the best calibration plots are; the logistic-logarithmic plot for prednisolone; nonlinear least squares fit to a polyexponential equation for prednisone; and a weighted least squares regression of normalized % bound versus concentration for digoxin. The error in the radioimmunoassay is usually concentration-dependent, and, in certain regions of the standard curve, is larger than the literature indicates, since, frequently, the error has been gauged from % bound values, but should be gauged from inversely-estimated concentrations.  相似文献   

3.
An original method based upon high-performance liquid chromatography coupled to ionspray mass spectrometry (HPLC–ISP-MS) has been developed for the identification and quantification in plasma of several cardiac glycosides, namely digoxin, digitoxin, lanatoside C and acetyldigitoxin. After single-step liquid–liquid extraction by chloroform–2-propanol (95:5, v/v) at pH 9.5 using oleandrin as an internal standard, solutes are separated on a 4 μm NovaPak C18 (Waters) column (150×2.0 mm, I.D.), using a gradient of acetonitrile–2 mM NH4COOH, pH 3 buffer (flow-rate 200 μl/min, post-column split 1:3). Detection is done by a Perkin-Elmer Sciex API-100 mass analyzer equipped with an ISP interface. In most instances the major ion observed is not [M+H]+ as expected, but [M+NH4]+. The mean retention times (min) are: lanatoside C, 5.74; digoxin, 6.00; digitoxin, 8.08, oleandrin, 8.30, acetyldigitoxin, 8.66 and 9.01 (isomers α and β, respectively). The lower limits of detection in single ion monitoring mode range from 0.15 ng/ml (α- and β-acetyldigitoxin) to 0.60 ng/ml (lanatoside C), making the method less sensitive than radioimmunoassay, whereas it is much more specific.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号