首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
This study applied the integrated cell culture/polymerase chain reaction methodology (ICC/PCR) for rapid and specific detection of both cytopathogenic and noncytopathogenic viruses. Results of this study showed that the use of direct RT-PCR or conventional cell culture alone may yield erroneous results with the analysis of environmental samples. The purpose of this study was to compare cultural, molecular, and combined assays for the most effective method of virus detection in variable environmental samples. Using ICC/PCR, stock enterovirus inocula of > or =10 PFU were PCR positive in at least 4/5 replicate flasks after only 5 h of incubation in cell culture, and in all flasks after > or =10 h. An inoculum of one PFU was detected by PCR after 20 h of cell culture incubation while for concentrations of virus below one PFU, 25 h of incubation was sufficient. Similarly, hepatitis A virus (HAV) inocula of 100 MPN/flask, produced indeterminate CPE in cell culture, but were clearly detected by ICC/PCR following 48 h of incubation. Lower levels of HAV, 1 and 10 MPN, were detected by ICC/PCR after 96 to 72 h of incubation, respectively. Cell culture lysates from 11 environmental sample concentrates of sewage, marine water, and surface drinking water sources, were positive for enteroviruses by ICC/PCR compared to 3 positive by direct RT-PCR alone. Results from ICC/PCR eventually agreed with cell culture but required < or =48 h of incubation, compared to as long as 3 weeks for CPE following incubation with BGM and FRhK cells.  相似文献   

4.
5.
This study focused on ultrafiltration as a technique for simultaneously concentrating and recovering viruses, bacteria and parasites in 100-L drinking water samples. A chemical dispersant, sodium polyphosphate, and Tween 80 were used to increase microbial recovery efficiencies. Secondary concentration was performed to reduce sample volumes to 3-5 mL for analysis using tissue culture, microscopy, and real-time PCR and RT-PCR. At seeding levels of 100-1000 (CFU, PFU, oocysts, or particles), a "high-flux" ultrafiltration procedure was found to achieve mean recoveries of 51-94% of simultaneously seeded MS2 bacteriophage, echovirus 1, Salmonella enterica subsp. enterica serovar Typhimurium, Bacillus atrophaeus subsp. globigii endospores, Cryptosporidium parvum oocysts, and 4.5-mum microspheres. When 4-7% of the final sample concentrate volume was assayed using real-time PCR and RT-PCR, overall method sensitivities were <100 C. parvum oocysts, <240 PFU echovirus 1, <100 CFU Salmonella and approximately 160 CFU B. atrophaeus spores in 100-L drinking water samples. The "high-flux" ultrafiltration procedure required approximately 2 h, including time required for backflushing. Secondary concentration procedures required an additional 1-3 h, while nucleic acid extraction and real-time PCR procedures required an additional 2-2.5 h. Thus, this study demonstrated that efficient recovery and sensitive detection of diverse microbes in 100-L drinking water samples could be achieved within 5-8 h using ultrafiltration, rapid secondary processing techniques, and real-time PCR.  相似文献   

6.
As part of our studies on the ecology of human enteric viruses, an improved method for detection of rotaviruses in water was developed, and their presence in Galveston Bay was monitored. Samples (378 liters) of estuarine water adjusted to pH 3.5 and a final AlCl3 molarity of 0.001 were filtered through 25-cm pleated cartridge-type filters (Filterite Corp., Timonium, Md.) of 3.0- and 0.45-micron porosity. Adsorbed virus was eluted with 1 liter of 10% tryptose phosphate broth, pH 9.5. Primary eluates were reconcentrated to a final volume of 10 to 20 ml by a simple and rapid magnetic iron oxide adsorption and elution procedure. Two percent casein at pH 8.5 effectively eluted rotavirus from iron oxide. A total of 21 of 72 samples of water, suspended solids, fluffy sediments, and compact sediments collected in different seasons in Galveston Bay yielded rotaviruses. Recovery of rotaviruses varied from 119 to 1,000 PFU/378 liters of water, 1,200 PFU/1,000 g of compact sediment, 800 to 3,800 PFU/378 liters of fluffy sediment, and 1,800 to 4,980 PFU from suspended solids derived from 378 liters of water based on immunofluorescent foci counts on cover slip cultures of fetal monkey kidney cells.  相似文献   

7.
As part of our studies on the ecology of human enteric viruses, an improved method for detection of rotaviruses in water was developed, and their presence in Galveston Bay was monitored. Samples (378 liters) of estuarine water adjusted to pH 3.5 and a final AlCl3 molarity of 0.001 were filtered through 25-cm pleated cartridge-type filters (Filterite Corp., Timonium, Md.) of 3.0- and 0.45-micron porosity. Adsorbed virus was eluted with 1 liter of 10% tryptose phosphate broth, pH 9.5. Primary eluates were reconcentrated to a final volume of 10 to 20 ml by a simple and rapid magnetic iron oxide adsorption and elution procedure. Two percent casein at pH 8.5 effectively eluted rotavirus from iron oxide. A total of 21 of 72 samples of water, suspended solids, fluffy sediments, and compact sediments collected in different seasons in Galveston Bay yielded rotaviruses. Recovery of rotaviruses varied from 119 to 1,000 PFU/378 liters of water, 1,200 PFU/1,000 g of compact sediment, 800 to 3,800 PFU/378 liters of fluffy sediment, and 1,800 to 4,980 PFU from suspended solids derived from 378 liters of water based on immunofluorescent foci counts on cover slip cultures of fetal monkey kidney cells.  相似文献   

8.
The effect of dewatering on the inactivation rates of enteric viruses in sludge was determined. For this study, water was evaporated from seeded raw sludge at 21 degrees C, and the loss of viral plaque-forming units was measured. Initial results with poliovirus showed that recoverable infectivity gradually decreased with the loss of water until the solids content reached about 65%. When the solids content was increased from 65 to 83%, a further, more dramatic decrease in virus titer of greater than three orders of magnitude was observed. This loss of infectivity was due to irreversible inactivation of poliovirus because viral particles were found to have released their RNA molecules which were extensively degraded. Viral inactivation in these experiments may have been at least partially caused by the evaporation process itself because similar effects on poliovirus particles were observed in distilled water after only partial loss of water by evaporation. Coxsackievirus and reovirus were also found to be inactivated in sludge under comparable conditions, which suggests that dewatering by evaporation may be a feasible method of inactivating all enteric viruses in sludge.  相似文献   

9.
The effect of dewatering on the inactivation rates of enteric viruses in sludge was determined. For this study, water was evaporated from seeded raw sludge at 21 degrees C, and the loss of viral plaque-forming units was measured. Initial results with poliovirus showed that recoverable infectivity gradually decreased with the loss of water until the solids content reached about 65%. When the solids content was increased from 65 to 83%, a further, more dramatic decrease in virus titer of greater than three orders of magnitude was observed. This loss of infectivity was due to irreversible inactivation of poliovirus because viral particles were found to have released their RNA molecules which were extensively degraded. Viral inactivation in these experiments may have been at least partially caused by the evaporation process itself because similar effects on poliovirus particles were observed in distilled water after only partial loss of water by evaporation. Coxsackievirus and reovirus were also found to be inactivated in sludge under comparable conditions, which suggests that dewatering by evaporation may be a feasible method of inactivating all enteric viruses in sludge.  相似文献   

10.
A method was developed for the selective enumeration of F male-specific bacteriophages in samples of environmental waters. The host strain for the phages, Escherichia coli HS(pFamp)R, has three antibiotic resistance markers, ampicillin on the Famp plasmid, which codes for pilus production, and streptomycin and nalidixic acid on the chromosome. The strain is resistant to coliphages T2 to T7 and phi X174. More than 95% of the phages from environmental samples which plaqued on the host strain were F male specific. The host bacterium had a higher plaquing efficiency than E. coli K-12 Hfr for F-specific phages in stock suspensions and sewage effluents. The F male-specific phage levels in prechlorinated, secondary-treated sewage effluents generally were about 10(3) to 10(4) PFU/100 ml. The levels in the influents to the sewage treatment plants and in septic tank contents were about 10(5) PFU/100 ml. RNA-containing phages composed about 90% of the total F-specific phage population in sewage effluents.  相似文献   

11.
12.
A method was developed for the selective enumeration of F male-specific bacteriophages in samples of environmental waters. The host strain for the phages, Escherichia coli HS(pFamp)R, has three antibiotic resistance markers, ampicillin on the Famp plasmid, which codes for pilus production, and streptomycin and nalidixic acid on the chromosome. The strain is resistant to coliphages T2 to T7 and phi X174. More than 95% of the phages from environmental samples which plaqued on the host strain were F male specific. The host bacterium had a higher plaquing efficiency than E. coli K-12 Hfr for F-specific phages in stock suspensions and sewage effluents. The F male-specific phage levels in prechlorinated, secondary-treated sewage effluents generally were about 10(3) to 10(4) PFU/100 ml. The levels in the influents to the sewage treatment plants and in septic tank contents were about 10(5) PFU/100 ml. RNA-containing phages composed about 90% of the total F-specific phage population in sewage effluents.  相似文献   

13.
Laboratory strains of enteroviruses, as well as viruses isolated from raw wastewater, were found to exhibit enhanced infectivity in vitro when BGM cell monolayers were pretreated with the cationic polymer polyethyleneimine (PEI). Viruses were assayed by the cytopathic effect technique and as PFU under methylcellulose and agar overlays with monolayers treated with 0 to 5.0 x 10(-3)% (wt/vol) PEI in phosphate-buffered saline supplemented with 2% fetal bovine serum. Poliovirus type 1 cytopathic effect occurred at an enhanced rate in cells treated with 5.0 x 10(-3)% PEI compared with untreated cells. PEI-treated cells were found to adsorb viruses much more effectively than untreated cells did. When the methylcellulose overlay procedure was used, rates of infectivity were enhanced as follows: poliovirus type 1, 5.5-fold; echovirus type 1, 1.2-fold; echovirus type 5, 5.2-fold; and coxsackievirus type B5, 4.9-fold. Viruses concentrated from raw wastewater showed a 3.8-fold increase in titer when quantitated by the most-probable-number method and a 3.3-fold increase when quantitated as PFU under an agar overlay.  相似文献   

14.
Laboratory strains of enteroviruses, as well as viruses isolated from raw wastewater, were found to exhibit enhanced infectivity in vitro when BGM cell monolayers were pretreated with the cationic polymer polyethyleneimine (PEI). Viruses were assayed by the cytopathic effect technique and as PFU under methylcellulose and agar overlays with monolayers treated with 0 to 5.0 x 10(-3)% (wt/vol) PEI in phosphate-buffered saline supplemented with 2% fetal bovine serum. Poliovirus type 1 cytopathic effect occurred at an enhanced rate in cells treated with 5.0 x 10(-3)% PEI compared with untreated cells. PEI-treated cells were found to adsorb viruses much more effectively than untreated cells did. When the methylcellulose overlay procedure was used, rates of infectivity were enhanced as follows: poliovirus type 1, 5.5-fold; echovirus type 1, 1.2-fold; echovirus type 5, 5.2-fold; and coxsackievirus type B5, 4.9-fold. Viruses concentrated from raw wastewater showed a 3.8-fold increase in titer when quantitated by the most-probable-number method and a 3.3-fold increase when quantitated as PFU under an agar overlay.  相似文献   

15.
An isolant of duck plague herpesvirus from the Lake Andes Refuge outbreak was seeded in raw and filter-decontaminated water from two locations on the refuge, held at 4 C, and assayed for infectivity intermittently over a period of 2 mo. From an initial level of about 10(5) PFU per ml, infectivity in the filtered samples uniformly dropped to about 10(4) PFU per ml. Infectivity in the raw samples declined much more rapidly; infectious virus remaining at the end of 2 mo (ca. 10(1) PFU per ml) was only about 0.01% of that originally seeded.  相似文献   

16.

Background

In a globalized word, prevention of infectious diseases is a major challenge. Rapid detection of viable virus particles in water and other environmental samples is essential to public health risk assessment, homeland security and environmental protection. Current virus detection methods, especially assessing viral infectivity, are complex and time-consuming, making point-of-care detection a challenge. Faster, more sensitive, highly specific methods are needed to quantify potentially hazardous viral pathogens and to determine if suspected materials contain viable viral particles. Fourier transform infrared (FTIR) spectroscopy combined with cellular-based sensing, may offer a precise way to detect specific viruses. This approach utilizes infrared light to monitor changes in molecular components of cells by tracking changes in absorbance patterns produced following virus infection. In this work poliovirus (PV1) was used to evaluate the utility of FTIR spectroscopy with cell culture for rapid detection of infective virus particles.

Results

Buffalo green monkey kidney (BGMK) cells infected with different virus titers were studied at 1 - 12 hours post-infection (h.p.i.). A partial least squares (PLS) regression method was used to analyze and model cellular responses to different infection titers and times post-infection. The model performs best at 8 h.p.i., resulting in an estimated root mean square error of cross validation (RMSECV) of 17 plaque forming units (PFU)/ml when using low titers of infection of 10 and 100 PFU/ml. Higher titers, from 103 to 106 PFU/ml, could also be reliably detected.

Conclusions

This approach to poliovirus detection and quantification using FTIR spectroscopy and cell culture could potentially be extended to compare biochemical cell responses to infection with different viruses. This virus detection method could feasibly be adapted to an automated scheme for use in areas such as water safety monitoring and medical diagnostics.  相似文献   

17.
18.
Pathogenic bacteria and enteric viruses can be introduced into the environment via human waste discharge. Methods for rapid detection and quantification of human viruses and fecal indicator bacteria in water are urgently needed to prevent human exposure to pathogens through drinking and recreational waters. Here we describe the development of two real-time PCR methods to detect and quantify human adenoviruses and enterococci in environmental waters. For real-time quantification of enterococci, a set of primers and a probe targeting the 23S rRNA gene were used. The standard curve generated using Enterococcus faecalis genomic DNA was linear over a 7-log-dilution series. Serial dilutions of E. faecalis suspensions resulted in a lower limit of detection (LLD) of 5 CFU/reaction. To develop real-time PCR for adenoviruses, degenerate primers and a Taqman probe targeting a 163-bp region of the adenovirus hexon gene were designed to specifically amplify 14 different serotypes of human adenoviruses, including enteric adenovirus serotype 40 and 41. The standard curve generated was linear over a 5-log-dilution series, and the LLD was 100 PFU/reaction using serial dilutions of purified adenoviral particles of serotype 40. Both methods were optimized to be applicable to environmental samples. The real-time PCR methods showed a greater sensitivity in detection of adenoviruses in sewage samples than the viral plaque assay and in detection of enterococci in coastal waters than the bacterial culture method. However, enterococcus real-time PCR overestimated the number of bacteria in chlorinated sewage in comparison with the bacterial culture method. Overall, the ability via real-time PCR to detect enterococci and adenoviruses rapidly and quantitatively in the various environmental samples represents a considerable advancement and a great potential for environmental applications.  相似文献   

19.
For virus recovery from sewage, a mixture of talc and Celite was tested as a possible inexpensive substitute for polyelectrolyte 60 (PE 60). After adjustment of pH to 6 and the addition of 45-60 plaque forming units (PFU)/ml of poliovirus type I (Sabin) to the sewage sample under test, 100 ml of it was passed through either a PE 60 (400 mg) or a talc (300 mg)-Celite (100 mg) layer; the layer-adsorbed virus was eluted with 10 ml of 10% fetal calf serum (FCS) in saline (pH 7.2). In these experiments, PE 60 layers recovered 73-80% (mean 76%) of the input virus. In comparison, virus recoveries with the talc-Celite layers were 65-70% (mean 68%). Passage of 5 litres of raw sewage (containing 50 to 1.26 X 10(5) PFU/100 ml of the poliovirus) through the talc (15 g)-Celite (5 g) layers and virus elution with 50 ml of 10% FCS in saline gave virus recoveries of 33-63% (mean 49%). Except for pH adjustment and prefiltration through two layers of gauze to remove large solids, no other sample pretreatment was found to be necessary. Application of this technique to recovery of indigenous viruses from field samples of raw sewage and effluents has been highly satisfactory.  相似文献   

20.
Interactions and survival of enteric viruses in soil materials   总被引:1,自引:0,他引:1  
There were marked differences in the abilities of eight different soil materials to remove and retain viruses from settled sewage, but for each soil material the behavior of two different viruses, poliovirus type 1 and reovirus type 3, was often similar. Virus adsorption to soil materials was rapid, the majority occurring within 15 min. Clayey materials efficiently adsorbed both viruses from wastewater over a range of pH and total dissolved solids levels. Sands and organic soil materials were comparatively poor adsorbents, but in some cases their ability to adsorb viruses increased at low pH and with the addition of total dissolved solids or divalent cations. Viruses in suspensions of soil material in settled sewage survived for considerable time periods, despite microbial activity. In some cases virus survival was prolonged in suspensions of soil materials compared to soil-free controls. Although sandy and organic soil materials were poor virus adsorbents when suspended in wastewater, they gave >/=95% virus removal from intermittently applied wastewater as unsaturated, 10-cm-deep columns. However, considerable quantities of the retained viruses were washed from the columns by simulated rainfall. Under the same conditions, clayey soil material removed >/=99.9995% of the viruses from applied wastewater, and none were washed from the columns by simulated rainfall.  相似文献   