首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
[背景]曝气生物滤池(Biological Aerated Filter,BAF)对有机物和氨氮的处理效果较好,但除磷效果不佳.[目的]提高BAF系统的除磷效能.[方法]在缺氧/好氧滤柱后设置了部分采用石灰石滤料的滤柱(未添加石灰石滤料的系统作为对照组),对比分析了使用石灰石滤柱出水回流BAF系统的处理效能,通过最大或...  相似文献   

2.
Han S  Yue Q  Yue M  Gao B  Zhao Y  Cheng W 《Bioresource technology》2009,100(3):1149-1155
Novel media-sludge-fly ash ceramic particles (SFCP) employed in an upflow lab-scale A/O BAF were investigated for synthetic wastewater treatment. The influences of hydraulic retention time (HRT), air-liquid ratio (A/L) and recirculation on the removals of chemical oxygen demand (CODcr), ammonia (NH(4)(+)-N) and total nitrogen (TN) were discussed. The optimum operation conditions were obtained as HRT of 2.0 h, A/L of 15:1 and 200% recirculation. Under the optimal conditions, 90% CODcr, more than 98% NH(3)-N and approximately 70% TN were removed. The average consumed volumetric loading rates for CODcr, NH(4)(+)-N and TN with 200% recirculation were 4.06, 0.36 and 0.29 kg(m(3)d)(-1), respectively. The CODcr and TN removal mainly occurred in the anoxic zone, while nitrification was completed at the height of 70 cm from the inlet of the bottom due to a suitable column layout of biological aerated filter (BAF). The characteristics of wastewater and backwashing affected TN removal to a large degree. In addition, the features of media (SFCP) and synthetic wastewater contributed to a strong buffer capacity in the BAF system so that the effluent pH at different media height fluctuated slightly and was insensitive to recirculation.  相似文献   

3.
A study was performed to assess the feasibility of anaerobic treatment of slaughterhouse wastewaters in a UASB (Upflow Anaerobic Sludge Blanket) reactor and in an AF (Anaerobic Filter). Among the different streams generated, the slaughter line showed the highest organic content with an average COD of 8000 mg/l, of which 70% was proteins. The suspended solids content represented between 15 and 30% of the COD. Both reactors had a working volume of 21. They were operated at 37°C. The UASB reactor was run at OLR (Organic Loading Rates) of 1–6.5 kg COD/m3/day. The COD removal was 90% for OLR up to 5 kg COD/m3/day and 60% for an OLR of 6.5 kg COD/m3/day. For similar organic loading rates, the AF showed lower removal efficiencies and lower percentages of methanization. At higher OLR sludge, flotation occurred and consequently the active biomass was washed out from the filter. The results indicated that anaerobic treatment systems are applicable to slaughterhouse wastewaters and that the UASB reactor shows a better performance, giving higher COD removal efficiencies than the AF.  相似文献   

4.
This study describes the feasibility of anaerobic treatment of synthetic coal wastewater using four identical 13.5L (effective volume) bench scale hybrid up flow anaerobic sludge blanket (HUASB) reactors (R1, R2, R3 and R4) under mesophilic (27+/-5 degrees C) conditions. Synthetic coal wastewater with an average chemical oxygen demand (COD) of 2240 mg/L and phenolics concentration of 752 mg/L was used as substrate. Effluent recirculation was employed at four different effluent to feed recirculation ratios (R/F) of 0.5, 1.0, 1.5 and 2.0 for 100 days to study the effect of recirculation on the performance of the reactors. Phenolics and COD removal was found to improve with increase in effluent recirculation. An effluent to feed recycle ratio of 1.0 resulted in maximum removal of phenolics and COD. Phenolics and COD removal improved from 88% and 92% to 95% each, respectively. The concentration of volatile fatty acids in the effluent was lower than the influent when effluent to feed recirculation was employed. Effect of shock loading on the reactors revealed that phenolics shock load up to 2.5 times increase in the normal input phenolics concentration in the form of continuous shock load for 4days did not affect the reactors performance irreversibly.  相似文献   

5.
The main purpose of this study was to evaluate the performance of a UASB reactor treating diluted black liquor from a Kraft pulp mill, which simulates an unbleached Kraft plant wastewater, under different operational conditions, including partial recycling of the effluent. The reactor's performance was evaluated from the standpoint of COD, pH, volatile acid concentration, alkalinity, concentration of methane in the biogas, and microbiological examinations of the sludge. Without recirculation the reduction of the HRT from 36 to 30h did not significantly affect the average COD removal efficiency. The parameter displaying the greatest variation was the average concentration of effluent volatile acids, which increased by 16%. With recirculation the reduction of the HRT from 30 to 24h increased the average COD removal efficiency from 75% to 78%. In this case, the average effluent alkalinity also showed an increase. The use of partial recirculation of the effluent did not improve significantly the COD removal under the operational conditions tested in this work, but it was possible to operate the reactor with lower hydraulic retention time without disintegration of the granules.  相似文献   

6.
A laboratory study has been conducted to obtained preliminary process information of a suspended growth Predenitrification (SGPDN)system. System performance was evaluated, in terms of chemical oxygen demand (COD) removal, NH(3)-N removal, system biomass yield and inventory, and effluent qualities, at different solids retention times (SRTs) and recycle ratios. Chemical oxygen demand removal in an SGPDN system occurs mainly in the anoxic reactor, which accounts for 94% of total COD removal. The overall COD removal rate is independent of recycle ratio (ranging from 2-5) used in this study; however, effluent COD increase with increasing recycle ratio. The observed anoxic and aerobic COD removal rates decrease with increasing SRT. The NH(3)-N removal in an SGPDN system is induced by two mechanisms: assimilatory NH(3)-N requirement for biomass production in the anoxic reactor and nitrification in the aerobic reactor. The observed anoxic NH(3)-N removal rate relates directly to the anoxic COD removal rate and agrees fairly well with the assimilatory NH(3)-N requirement theoretically predicted. The overall NH(3)-N removal rate is independent of SRTs and recycle ratios used in this study. Biomass yield in an SGPDN system occurs mainly in the anoxic reactor. However, uniform distribution of biomass throughout the entire system is obtained because of the high recycle rate used. The observed biomass yield (Y(O)) decreases with increasing STR. Tertiary treatment efficiency can be achieved in an SGPDN system. More than 90% reduction in feed COD., feed NH(3)-N, and NO(2) + NO(3)-N is obtained at all SRTs and recycle ratios used in this study. Higher MLVSS loading rates can be applied to a final clarifier without impairing its separation efficiency because of the excellent settleability of the Predenitrification activated sludge.  相似文献   

7.
A laboratory scale rotating biological contactor (RBC) predenitrification system incorporating anoxic and aerobic units was evaluated for the treatment of settled high-strength municipal wastewater. The system was operated under four recycle ratios (1, 2, 3 and 4) and loading rates of 38-182 gCOD/m(2)d and 0.22-14 gOxid-N/m(2)d on the anoxic unit and 3.4-18 gCOD/m(2)d and 0.24-1.8 gNH(4)-N/m(2)d on the aerobic. The average removal efficiency in terms of chemical oxygen demand (COD), biochemical oxygen demand (BOD(5)), total suspended solids (TSS) and total nitrogen (Total-N) was 82%, 86%, 63% and 54%; settling of the RBC effluent increased COD and TSS removal to 94% and 97%. An increase in hydraulic loading resulting from higher recirculation, had limited negative effect on organic removal but improved nitrogen removal, and in terms of Total-N removal efficiency increased up to a ratio of 3 and then decreased.  相似文献   

8.
A study of anaerobic digestion of piggery wastewater was carried out in a laboratory-scale sludge bed reactor as a secondary treatment. The effect of organic volumetric loading rates (BV) in the range of 1.0-8.1 g TCOD/ld on the process performance was evaluated. The best results were obtained at BV equal to or lower than 4 g TCOD/ld. At higher BV values, the removal efficiency of the process decreased suddenly. A linear relationship was found between the effluent SCOD and the TVFA/alkalinity ratio (P). A relationship was found among the different operational variables (BV , removal efficiency, effluent soluble COD, soluble COD removal rate (R), retention factor (phi), specific microbial growth rate (mu), methane production rate per volume of reactor and per volume of waste treated--QM and qM, respectively) and the corresponding regression equations were obtained. An increase of BV determined a decrease of removal efficiency, phi and qM and an increase of effluent soluble COD, mu, R and QM. The value of the maximum specific microbial growth rate (muM) determined through the equation that correlated BV and mu was found to be 0.19 d(-1). This value was of the same magnitude as those reported in other works of anaerobic digestion of piggery waste.  相似文献   

9.
Wastewater from the pre-treatment of coffee pulp for mushroom cultivation was treated in an anaerobic filter reactor at laboratory scale. The digester was fed semicontinuously with 300 to 500 ml of fresh medium per day. Organic loading rates (OLR) applied ranged widely during the study, from 0.48 to 62.93 g chemical oxygen demand (COD)/1 d. Treating wastewater from the pasteurization of pulp, the highest strength studied, a COD removal efficiency of up to 87% was attained at a high OLR of 42.868 g COD/I d; while a high biogas production rate (BPR) of 2.89 I/I d was also achieved. However, the average organic matter removal efficiency was 53% at an OLR of 23.921 g COD/1 d, which indicates that process efficiency should be improved to achieve a good quality effluent. BPR averaged 1.72 1/1 d, which shows that with technical-scale reactors, high biogas production could be obtained for further use in the pasteurizing process itself (energy recycling).  相似文献   

10.
The removal of nitrate from rinse wastewater generated in the stainless steel manufacturing process by denitrification in a sequential batch reactor (SBR) was studied. Two different inocula from wastewater treatment plants were tested. The use of an inoculum previously acclimated to high nitrate concentrations led to complete denitrification in 6h (denitrification rate: 22.8mg NO(3)(-)-N/gVSSh), using methanol as carbon source for a COD/N ratio of 4 and for a content of calcium in the wastewater of 150mg/L. Higher calcium concentrations led to a decrease in the biomass growth rate and in the denitrification rate. The optimum COD/N ratio was found to be 3.4, achieving 98% nitrate removal in 7h at a maximum rate of 30.4mg NO(3)(-)-N/gVSSh and very low residual COD in the effluent.  相似文献   

11.
Two lab-scale anaerobic hybrid reactors (AHR) were operated to investigate the effect of recirculated biogas on the development of biomass on supporting media during the start-up. The reactor comprised of two distinct zones; sludge bed on the bottom and packed bed using nylon fiber as the media on the upper half of the reactor. Both reactors were continuously fed with cassava starch wastewater. The organic loading rate (OLR) was increased from 0.3 to 5.5 g COD/L/day by gradually decreasing the hydraulic retention time (HRT) from 37 to 3.5 days in two months. The biogas at 2.6 L/L/day was recirculated merely in the first month of the operation in order to allow the attached biomass to grow according to the organic matters present in the reactor at the final stage of the start up. Chemical oxygen demand (COD) removal efficiency of over 80% was achieved throughout the study. The result demonstrated a better COD removal efficiency for the reactor with biogas recirculation, especially at low HRTs. The amounts of biomass accumulated on the media in both reactors were slightly different with 11.9 gVSS found on the one with biogas recirculation compared to 9.8 gVSS on the other. In addition, 16.3% increase of the sludge bed was achieved with biogas recirculation as opposed to 9% in the control one. The attached biomass activity test indicated a greater amount and more favorable ratio of the methanogenic bacterial group on the media with the recirculation correlating well to a relatively higher methane content in biogas. As a result, the recirculation of biogas has a potential of improving the characteristics of the AHR especially in terms of biomass accumulation.  相似文献   

12.
Influence of recirculation on the performance of anaerobic sequencing batch biofilm reactor (AnSBBR) was studied in the process of treating hypersaline (total dissolved inorganic solids (TDIS) approximately 26 g/l) and low biodegradable (BOD/COD approximately 0.3) composite chemical wastewater. Significant enhancement in the substrate removal efficiency and biogas yield was observed after introducing the recirculation to the system. Maximum efficiency (COD removal efficiency - 51%; SDR - 3.14 kg COD/cum-day) was observed at recirculation to feed (R/F) ratio of 2 (OLR - 6.15 kg C OD/cum-day; HLR - 2.30 cum (liquid)/cum day; UFV(A) - 0.023 m/h). Subsequent increase of R/F to 3 (OLR - 6.15 kg COD/cum-day; HLR - 3.07cum (liquid)/cum-day; UFV(A) - 0.035 m/h) resulted in reduction in COD removal efficiency (32%; SDR - 1.97 kg COD/cum-day). The enhanced performance of the system due to the introduction of recirculation was attributed to the improvement in the mass transfer between the substrate present in the bulk liquid and the attached biofilm. The hydrodynamic behavior due to recirculation mode of operation reduced the concentration gradient (substrate inhibition) of substrate and reaction by-products (VFA) resulting in mixed flow conditions.  相似文献   

13.
Rhizopus microsporus was grown in an attached growth system using corn wet-milling effluent as a growth medium. This strain was chosen due to its ability to effectively degrade organic matter in corn wet-milling effluent and for its properties to produce significant levels of protein, chitin and chitosan. Fungal growth and organic removal efficiency were examined under both aseptic and non-aseptic conditions with and without nutrient supplementation. Plastic composite support (PCS) tubes, composed of 50% (w/w) polypropylene (PP) and 50% (w/w) agricultural products were used as support media. Significantly higher organic removal measured as chemical oxygen demand (COD) and biomass yield were observed in the bioreactor with PCS tubes than in two control bioreactors; that is with PP tubes alone and suspended growth (without support media). This confirmed that the PCS support medium with agricultural components enhanced fungal growth and organic removal. The results showed that supplementation of nutrients (e.g., mineral salts) under aseptic conditions enhanced the COD removal from 50% to 55% and observed biomass yield from 0.11 to 0.16 g (dry-weight)/g COD(removed) (i.e., from 0.10 to 0.14 g volatile solids (VS)/g COD(removed) approximately). Non-aseptic operation without nutrient supplementation resulted in an observed biomass yield of 0.32 g volatile suspended solids (VSS)/g COD(removed) with no significant improvement in COD removal ( approximately 53%); whereas with nutrient supplementation, the observed biomass yield increased to 0.56 g VSS/g COD(removed) and COD removal improved to 85%. The fungal system was able to degrade the organic matter with concomitant production of high-value fungal biomass. This is the first study that examined the conversion of corn milling waste stream into high value fungal protein.  相似文献   

14.
A kinetic model for the anaerobic filter (AF) that takes into account the mass fractions of sulfate-reducing bacteria (SRB) (f(SRB)) and methanogenic bacteria (MB) (f(MB)) and an inhibiting effect of H(2)S on bacterial groups is proposed. When the acetate-fed AFs were maintained at the low organic loading rate of 2.5kg COD/m(3)d, variations of the influent COD/SO(4)(2-) ratio (0.5-3.0) does not materially affect the acetate removal efficiency (all varying between 98.1% and 99.7%). With an increase in influent COD/SO(4)(2-) ratio, both the biofilm thickness and the specific substrate utilization rate decreased slightly but f(SRB) decreased markedly. The estimated results of f(SRB) and f(MB) showed that SRB out-competed MB for bacterial growth if the influent COD/SO(4)(2-) ratio was maintained at less than 1.3, whereas MB out-competed SRB for bacterial growth if the influent COD/SO(4)(2-) ratio was maintained at greater than 2.0. The specific substrate utilization rate of SRB (0.19-0.24mg acetate/mg VSSd) was lower than that of MB (0.31-0.59mg acetate/mg VSSd). The estimated kinetic parameters disclosed that the affinity of acetate to MB was higher and unionized H(2)S imposed a greater inhibiting effect on MB. The model simulation results (acetate and sulfate removal) agreed well with the experimental results.  相似文献   

15.
Fu Z  Zhang Y  Wang X 《Bioresource technology》2011,102(4):3748-3753
In this study, the performance of the anoxic filter bed and biological wriggle bed-ozone biological aerated filter (AFB-BWB-O3-BAF) process treating real textile dyeing wastewater was investigated. After more than 2 month process operation, the average effluent COD concentration of the AFB, BWB, O3-BAF were 704.8 mg/L, 294.6 mg/L and 128.8 mg/L, with HRT being 8.1-7.7 h, 9.2 h and 5.45 h, respectively. Results showed that the effluent COD concentration of the AFB decreased with new carriers added and the average removal COD efficiency was 20.2%. During operation conditions, HRT of the BWB and O3-BAF was increased, resulting in a decrease in the effluent COD concentration. However, on increasing the HRT, the COD reduction capability expressed by the unit carrier COD removal loading of the BWB reactor increased, while that of the O3-BAF reactor decreased. This study is a beneficial attempt to utilize the AFB-BWB-O3-BAF combine process for textile wastewater treatment.  相似文献   

16.
煤渣-草炭基质垂直流人工湿地系统对城市污水的净化效果   总被引:41,自引:3,他引:38  
垂直流人工湿地系统不但具有较高的水力负荷率(54—64cm.^-1),而且对有机物和N、P都具有较高的去除效果.其对化粪池出水中的COD、BOD5、NIA4^+-N和总P的去除率分别为76%--87%,88%--92%,75%--85%和77%--91%.处理出水中COD、BOD5、NH4^+-N和总P的平均浓度分别小于60、20、25和2.0mg.L^-1.植物种植试验结果表明,种植风车草可提高氨氮、总N和总P的去除率,分别为2%--3%、4%--6%、10%--14%.  相似文献   

17.
Wu S  Yue Q  Qi Y  Gao B  Han S  Yue M 《Bioresource technology》2011,102(3):2296-2300
Novel media-ultra-lightweight sludge ceramics (ULSC) employed in an upflow lab-scale biological aerobic filter (BAF) were investigated for pharmaceutical advanced wastewater treatment. The influences of the volume ratio of pharmaceutical wastewater to domestic wastewater (PW/DW), hydraulic retention time (HRT) and air-liquid ratio (A/L) on chemical oxygen demand (CODCr) and ammonium (NH(4)(+)-N) of the effluent were investigated. When PW/DW of 4:1, HRT of 6 h, and A/L of 5:1 were applied, the mean effluent concentration of NH(4)(+)-N was 6.2 mg L(-1), and the maximum CODCr concentration in the effluent was 96 mg L(-1). Both NH(4)(+)-N and CODCr did not exceed the limits of the national discharge standards (NH(4)(+)-N ≤ 15 mg L(-1), CODCr ≤ 100 mg L(-1)). In addition, the BAF system showed a strong capacity of further removal from NH(4)(+)-N of the effluent.  相似文献   

18.
A laboratory-scale hybrid-denitrification filter (HDF) was designed by combining a plant material digester and a denitrification filter into a single unit for the removal of nitrate and phosphorus from glasshouse hydroponic wastewater. The carbon to nitrate (C:N) ratio for efficient operation of the HDF was calculated to be 1.93:1 and the COD/BOD5 ratio was 1.2:1. When the HDF was continuously operated with the plant material replaced every 2 days and 100% internal recirculation of the effluent, a high level of nitrate removal (320–5 mg N/L, >95% removal) combined with a low effluent sBOD5 concentration (<5 mg/L) was consistently achieved. Moreover, phosphate concentrations in the effluent were maintained below 7.5 mg P/L (>81% reduction). This study demonstrates the potential to combine a digester and a denitrification filter in a single unit to efficiently remove nitrate and phosphate from hydroponic wastewater in a single unit.  相似文献   

19.
Biodegradation of linear alkylbenzene sulfonate (LAS) was shown in an upflow anaerobic sludge blanket reactor under thermophilic conditions. The reactor was inoculated with granular biomass and fed with a synthetic medium and 3 micromol/L of a mixture of LAS with alkylchain length of 10 to 13 carbon atoms. The reactor was operated with a hydraulic retention time of 12 h with effluent recirculation in an effluent to influent ratio of 5 to 1. A sterile reactor operated in parallel revealed that sorption to sludge particles initially accounted for a major LAS removal. After 8 days of reactor operation, the removal of LAS in the reactor inoculated with active granular biomass exceeded the removal in the sterile reactor inoculated with sterile granular biomass. The effect of sorption ceased after 185 to 555 h depending on the LAS homologs. 40% of the LAS was biodegraded, and the removal rate was 0.5 x 10(-6) mol/h/mL granular biomass. Acidified effluent from the reactor was subjected to dichloromethane extraction followed by gas chromatography/mass spectrometry. Benzenesulfonic acid and benzaldehyde were detected in the reactor effluent from the reactor with active granular biomass but not in the sterile and unamended reactor effluent. Benzenesulfonic acid and benzaldehyde are the first identified degradation products in the anaerobic degradation of LAS.  相似文献   

20.
Tuna condensate was a better substrate than shrimp-blanching water or effluent from a frozen-seafood plant for growing Rhodocyclus gelatinosus under anaerobic conditions in the light. One strain out of four examined, R7, gave the highest biomass (4.0 g/l), cell yield (0.32 g cell/g COD), and COD removal (78%) in 1:10 (v/v) diluted tuna condensate. Shrimp-blanching water added to the tuna condensate further increased growth rate, biomass and COD removal. Optimal growth was at pH 7.0 and 3000 Lux light intensity. Acetate, pyruvate, glucose, glutamate, propionate or malate added to the tuna condensate did not increase cell yield, carotenoid or bacteriochlorophyll content or biomass protein. A maximum cell mass of 5.6 g/l (containing 50% protein) and 86% COD removal were obtained after 5 days' incubation under optimal conditions.  相似文献   