首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We studied the effects of left lower lobe (LLL) alveolar hypoxia on pulmonary gas exchange in anesthetized dogs using the multiple inert gas elimination technique (MIGET). The left upper lobe was removed, and a bronchial divider was placed. The right lung (RL) was continuously ventilated with 100% O2, and the LLL was ventilated with either 100% O2 (hyperoxia) or a hypoxic gas mixture (hypoxia). Whole lung and individual LLL and RL ventilation-perfusion (VA/Q) distributions were determined. LLL hypoxia reduced LLL blood flow and increased the perfusion-related indexes of VA/Q heterogeneity, such as the log standard deviation of the perfusion distribution (log SDQ), the retention component of the arterial-alveolar difference area [R(a-A)D], and the retention dispersion index (DISPR*) of the LLL. LLL hypoxia increased blood flow to the RL and reduced the VA/Q heterogeneity of the RL, indicated by significant reductions in log SDQ, R(a-A)D, and DISPR*. In contrast, LLL hypoxia had little effect on gas exchange of the lung when evaluated as a whole. We conclude that flow diversion induced by regional alveolar hypoxia preserves matching of ventilation to perfusion in the whole lung by increasing gas exchange heterogeneity of the hypoxic region and reducing heterogeneity in the normoxic lung.  相似文献   

2.
We studied the independent influence of changes in perfusion on pulmonary gas exchange in the left lower lobe (LLL) of anesthetized dogs. Blood flow to the LLL (QLLL) was raised 50% (increased QLLL) or reduced 50% (decreased QLLL) from baseline by partial occlusion of the right or left pulmonary artery, respectively. Minute ventilation and alveolar PCO2 of the LLL remained constant throughout the study. We determined ventilation-perfusion distributions of the LLL using the multiple inert gas elimination technique. Increased QLLL impaired LLL pulmonary gas exchange. All dispersion indexes and all arterial-alveolar difference areas increased (P less than 0.01). Decreased QLLL increased the log standard deviation of the perfusion distribution (P less than 0.05) and reduced the log standard deviation of the ventilation distribution (P less than 0.01) but did not affect the dispersion indexes or alveolar-arterial difference areas. We conclude that ventilation-perfusion heterogeneity is increased by independent changes in perfusion from normal baseline blood flow, even when ventilation and alveolar gas composition remain constant.  相似文献   

3.
We studied the effects of regional hypoxic pulmonary vasoconstriction (HPV) on lobar flow diversion in the presence of hydrostatic pulmonary edema. Ten anesthetized dogs with the left lower lobe (LLL) suspended in a net for continuous weighing were ventilated with a bronchial divider so the LLL could be ventilated with either 100% O2 or a hypoxic gas mixture (90% N2-5% CO2-5% O2). A balloon was inflated in the left atrium until hydrostatic pulmonary edema occurred, as evidenced by a continuous increase in LLL weight. Left lower lobe flow (QLLL) was measured by electromagnetic flow meter and cardiac output (QT) by thermal dilution. At a left atrial pressure of 30 +/- 5 mmHg, ventilation of the LLL with the hypoxic gas mixture caused QLLL/QT to decrease from 17 +/- 4 to 11 +/- 3% (P less than 0.05), pulmonary arterial pressure to increase from 35 +/- 5 to 37 +/- 6 mmHg (P less than 0.05), and no significant change in rate of LLL weight gain. Gravimetric confirmation of our results was provided by experiments in four animals where the LLL was ventilated with an hypoxic gas mixture for 2 h while the right lung was ventilated with 100% O2. In these animals there was no difference in bloodless lung water between the LLL and right lower lobe. We conclude that in the presence of left atrial pressures high enough to cause hydrostatic pulmonary edema, HPV causes significant flow diversion from an hypoxic lobe but the decrease in flow does not affect edema formation.  相似文献   

4.
High-resolution measurements of pulmonary perfusion reveal substantial spatial heterogeneity that is fractally distributed. This observation led to the hypothesis that the vascular tree is the principal determinant of regional blood flow. Recent studies using aerosol deposition show similar ventilation heterogeneity that is closely correlated with perfusion. We hypothesize that ventilation has fractal characteristics similar to blood flow. We measured regional ventilation and perfusion with aerosolized and injected fluorescent microspheres in six anesthetized, mechanically ventilated pigs in both prone and supine postures. Adjacent regions were clustered into progressively larger groups. Coefficients of variation were calculated for each cluster size to determine fractal dimensions. At the smallest size lung piece, local ventilation and perfusion are highly correlated, with no significant difference between ventilation and perfusion heterogeneity. On average, the fractal dimension of ventilation is 1.16 in the prone posture and 1. 09 in the supine posture. Ventilation has fractal properties similar to perfusion. Efficient gas exchange is preserved, despite ventilation and perfusion heterogeneity, through close correlation. One potential explanation is the similar geometry of bronchial and vascular structures.  相似文献   

5.
Although recent high-resolution studies demonstrate the importance of nongravitational determinants for both pulmonary blood flow and ventilation distributions, posture has a clear impact on whole lung gas exchange. Deterioration in arterial oxygenation with repositioning from prone to supine posture is caused by increased heterogeneity in the distribution of ventilation-to-perfusion ratios. This can result from increased heterogeneity in regional blood flow distribution, increased heterogeneity in regional ventilation distribution, decreased correlation between regional blood flow and ventilation, or some combination of the above (Wilson TA and Beck KC, J Appl Physiol 72: 2298-2304, 1992). We hypothesize that, although repositioning from prone to supine has relatively small effects on overall blood flow and ventilation distributions, regional changes are poorly correlated, resulting in regional ventilation-perfusion mismatch and reduction in alveolar oxygen tension. We report ventilation and perfusion distributions in seven anesthetized, mechanically ventilated pigs measured with aerosolized and injected microspheres. Total contributions of pulmonary structure and posture on ventilation and perfusion heterogeneities were quantified by using analysis of variance. Regional gradients of posture-mediated change in ventilation, perfusion, and calculated alveolar oxygen tension were examined in the caudocranial and ventrodorsal directions. We found that pulmonary structure was responsible for 74.0 +/- 4.7% of total ventilation heterogeneity and 63.3 +/- 4.2% of total blood flow heterogeneity. Posture-mediated redistribution was primarily oriented along the caudocranial axis for ventilation and along the ventrodorsal axis for blood flow. These mismatched changes reduced alveolar oxygen tension primarily in the dorsocaudal lung region.  相似文献   

6.
Endotoxin increases ventilation-to-perfusion ratio (VA/Q) heterogeneity in the lung, but the precise changes in alveolar ventilation (VA) and perfusion that lead to VA/Q heterogeneity are unknown. The purpose of this study was to determine how endotoxin affects the distributions of ventilation and perfusion and the impact of these changes on VA/Q heterogeneity. Seven anesthetized, mechanically ventilated juvenile pigs were given E. coli endotoxin intravenously, and regional ventilation and perfusion were measured simultaneously by using aerosolized and injected fluorescent microspheres. Endotoxemia significantly decreased the correlation between regional ventilation and perfusion, increased perfusion heterogeneity, and redistributed perfusion between lung regions. In contrast, ventilation heterogeneity did not change, and redistribution of ventilation was modest. The decrease in correlation between regional ventilation and perfusion was responsible for significantly more VA/Q heterogeneity than were changes in ventilation or perfusion heterogeneity. We conclude that VA/Q heterogeneity increases during endotoxemia primarily as a result of the decrease in correlation between regional ventilation and perfusion, which is in turn determined primarily by changes in perfusion.  相似文献   

7.

Background

Allergic non-asthmatic (ANA) adults experience upper airway symptoms of allergic disease such as rhinorrhea, congestion and sneezing without symptoms of asthma. The aim of this study was to utilize PET-CT functional imaging to determine whether allergen challenge elicits a pulmonary response in ANA subjects or whether their allergic disease is truly isolated to the upper airways.

Methods

In 6 ANA subjects, bronchoalveolar lavages (BAL) were performed at baseline and 24h after instillation of an allergen and a diluent in separate lung lobes. After instillation (10h), functional imaging was performed to quantify and compare regional perfusion, ventilation, fractional gas content (Fgas), and glucose uptake rate (Ki) between the baseline, diluent and allergen lobes. BAL cell counts were also compared.

Results

In ANA subjects, compared to the baseline and diluent lobes, perfusion and ventilation were significantly lower in the allergen lobe (median [inter-quartile range], baseline vs. diluent vs. allergen: Mean-normalized perfusion; 0.87 [0.85–0.97] vs. 0.90 [0.86–0.98] vs. 0.59 [0.55–0.67]; p<0.05. Mean-normalized ventilation 0.89 [0.88–0.98] vs. 0.95 [0.89–1.02] vs. 0.63 [0.52–0.67], p<0.05). In contrast, no significant differences were found in Fgas between baseline, diluent and allergen lobes or in Ki. Total cell counts, eosinophil and neutrophil cell counts (cells/ml BAL) were significantly greater in the allergen lobe compared to the baseline lobe (all P<0.05).

Conclusions

Despite having no clinical symptoms of a lower airway allergic response (cough and wheeze) allergic non-asthmatic subjects have a pulmonary response to allergen exposure which manifests as reduced ventilation and perfusion.  相似文献   

8.
The influence of blood flow through the pulmonary circulation on the time course of recovery of the lung periphery from challenge with three bronchoconstrictive agents was studied in dogs. The rate of perfusion of the left lower lobe was varied between 0 and 300 ml/min. A fiber-optic bronchoscope (OD = 5.5 mm) was wedged in a small airway in the same lobe, and resistance to airflow through the collateral system was continuously monitored. The lung was challenged with histamine aerosol for 1 min, or with intravenous boluses of histamine, acetylcholine, or methacholine. The time constant (tau) of recovery from each of the challenges was measured under the various pulmonary blood flow conditions. The mean tau of the recoveries from histamine was inversely related to the rate of blood flow. However, pulmonary blood flow had no effect on recovery from challenge with acetylcholine or methacholine, two agents metabolized by cholinesterase in lung tissue. From this study we conclude that recovery of the lung periphery from histamine is perfusion dependent, whereas recovery from acetylcholine or methacholine is perfusion independent. This suggests that the rate of blood flow through the pulmonary circulation could play an important role in recovery of the peripheral airways from certain mediators of bronchoconstriction.  相似文献   

9.
To explore mechanisms of hypoxemia after acutepulmonary embolism, we measured regional pulmonary blood flow andalveolar ventilation before and after embolization with 780-µm beadsin five anesthetized, mechanically ventilated pigs. Regionalventilation and perfusion were determined in~2.0-cm3 lung volumes by using1-µm-diameter aerosolized and 15-µm-diameter injected fluorescentmicrospheres. Hypoxemia after embolization resulted from increasedperfusion to regions with low ventilation-to-perfusion ratios.Embolization caused an increase in perfusion heterogeneity and a fallin the correlation between ventilation and perfusion. Correlationbetween regional ventilation pre- and postembolization was greater thancorrelation between regional perfusion pre- and postembolization. Themajority of regional ventilation-to-perfusion ratio heterogeneity wasattributable to changes in regional perfusion. Regional perfusionredistribution without compensatory changes in regional ventilation isresponsible for hypoxemia after pulmonary vascular embolization in pigs.

  相似文献   

10.
The multiple inert gas elimination technique (MIGET) was applied to blood-free perfused isolated rabbit lungs. Commonly accepted criteria for reliability of the method were found to be fulfilled in this model. Ventilation-perfusion (VA/Q) distributions in isolated control lungs corresponded to those repeatedly detected under physiological conditions. In particular, a narrow unimodal dispersion of perfusate flow was observed: perfusion of low-VA/Q areas ranged below 1% and shunt flow approximately 2-3%; perfusion of high-VA/Q regions was not detected. Gas flow was characterized by narrow dispersion in the midrange-VA/Q areas. Application of a low level of PEEP (1 cmH2O) reduced shunt flow to less than 1%, and low-VA/Q areas were no longer noted. By using this PEEP-level, stable gas exchange conditions were maintained for greater than 5 h of extracorporeal perfusion. Graded embolization with small air bubbles caused a typical rightward shift (to higher VA/Q ratios) of mean ventilation, associated with the appearance of high-VA/Q regions and an increase in dead space ventilation. Mean perfusion was shifted leftward, and shunt flow was approximately doubled. Whole lung lavage with saline for washout of surfactant evoked a progressive manifold increase in shunt flow, accompanied by a moderate rise of perfusate flow to low-VA/Q areas. We conclude that the MIGET can be applied to isolated blood-free perfused rabbit lungs for assessment of gas exchange and that typical patterns of VA/Q mismatch are reproduced in this model.  相似文献   

11.
The relationship between regional variabilities in airflow (ventilation) and blood flow (perfusion) is a critical determinant of gas exchange efficiency in the lungs. Hypoxic pulmonary vasoconstriction is understood to be the primary active regulator of ventilation-perfusion matching, where upstream arterioles constrict to direct blood flow away from areas that have low oxygen supply. However, it is not understood how the integrated action of hypoxic pulmonary vasoconstriction affects oxygen transport at the system level. In this study we develop, and make functional predictions with a multi-scale multi-physics model of ventilation-perfusion matching governed by the mechanism of hypoxic pulmonary vasoconstriction. Our model consists of (a) morphometrically realistic 2D pulmonary vascular networks to the level of large arterioles and venules; (b) a tileable lumped-parameter model of vascular fluid and wall mechanics that accounts for the influence of alveolar pressure; (c) oxygen transport accounting for oxygen bound to hemoglobin and dissolved in plasma; and (d) a novel empirical model of hypoxic pulmonary vasoconstriction. Our model simulations predict that under the artificial test condition of a uniform ventilation distribution (1) hypoxic pulmonary vasoconstriction matches perfusion to ventilation; (2) hypoxic pulmonary vasoconstriction homogenizes regional alveolar-capillary oxygen flux; and (3) hypoxic pulmonary vasoconstriction increases whole-lobe oxygen uptake by improving ventilation-perfusion matching.  相似文献   

12.
Using positron emission tomography (PET) and intravenously injected (13)N(2), we assessed the topographical distribution of pulmonary perfusion (Q) and ventilation (V) in six healthy, spontaneously breathing subjects in the supine and prone position. In this technique, the intrapulmonary distribution of (13)N(2), measured during a short apnea, is proportional to regional Q. After resumption of breathing, regional specific alveolar V (sVA, ventilation per unit of alveolar gas volume) can be calculated from the tracer washout rate. The PET scanner imaged 15 contiguous, 6-mm-thick, slices of lung. Vertical gradients of Q and sVA were computed by linear regression, and spatial heterogeneity was assessed from the squared coefficient of variation (CV(2)). Both CV and CV were corrected for the estimated contribution of random imaging noise. We found that 1) both Q and V had vertical gradients favoring dependent lung regions, 2) vertical gradients were similar in the supine and prone position and explained, on average, 24% of Q heterogeneity and 8% of V heterogeneity, 3) CV was similar in the supine and prone position, and 4) CV was lower in the prone position. We conclude that, in recumbent, spontaneously breathing humans, 1) vertical gradients favoring dependent lung regions explain a significant fraction of heterogeneity, especially of Q, and 2) although Q does not seem to be systematically more homogeneous in the prone position, differences in individual behaviors may make the prone position advantageous, in terms of V-to-Q matching, in selected subjects.  相似文献   

13.
In 12 anesthetized paralyzed dogs, pulmonary gas exchange and intrapulmonary inspired gas distribution were compared between continuous-flow ventilation (CFV) and conventional mechanical ventilation (CMV). Nine dogs were studied while they were lying supine, and three dogs were studied while they were lying prone. A single-lumen catheter for tracheal insufflation and a double-lumen catheter for bilateral endobronchial insufflation [inspired O2 fraction = 0.4; inspired minute ventilation = 1.7 +/- 0.3 (SD) 1.kg-1.min-1] were evaluated. Intrapulmonary gas distribution was assessed from regional 133Xe clearances. In dogs lying supine, CO2 elimination was more efficient with endobronchial insufflation than with tracheal insufflation, but the alveolar-arterial O2 partial pressure difference was larger during CFV than during CMV, regardless of the type of insufflation. By contrast, endobronchial insufflation maintained both arterial PCO2 and alveolar-arterial O2 partial pressure difference at significantly lower levels in dogs lying prone than in dogs lying supine. In dogs lying supine, the dependent lung was preferentially ventilated during CMV but not during CFV. In dogs lying prone, gas distribution was uniform with both modes of ventilation. The alveolar-arterial O2 partial pressure difference during CFV in dogs lying supine was negatively correlated with the reduced ventilation of the dependent lung, which suggests that increased ventilation-perfusion mismatching was responsible for the increase in alveolar-arterial O2 partial pressure difference. The more efficient oxygenation during CFV in dogs lying prone suggests a more efficient matching of ventilation to perfusion, presumably because the distribution of blood flow is also nearly uniform.  相似文献   

14.
摘要 目的:探讨抑郁症患者的脑CT灌注成像特征与认知功能的相关性。方法:选取我院2020年1月到2023年1月收治的90例抑郁症患者作为研究对象,将其分为观察组,另选取同期来我院体检的90名健康志愿者作为对照组。收集所有受检者脑CT灌注成像检查数据,分析抑郁症患者的脑CT灌注成像特征,并建立受试者工作特征(ROC)曲线分析脑CT灌注成像对抑郁症的诊断效能。随后对观察组和对照组受检者均进行认知功能评估,其中包括连线检测(TMT)、视觉再生测验(VRT)、言语流畅性测验(VF)、数字广度测验(DST)以及数字符号测验(SDMT),并分析脑CT灌注成像与抑郁症认知功能的相关性。结果:观察组与对照组受检者rCBV、rCBF、MTT、TIP、右枕叶、左枕叶、右颞叶、左颞叶、右顶叶、左顶叶CT值对比无明显差异(P>0.05),观察组与对照组受检者右额叶、左额叶CT值对比差异显著,观察组明显低于对照组(P<0.05);90例抑郁症患者经过汉密尔顿抑郁量表(HAMD)评估后分数均>20分,确定存在抑郁症状,脑CT灌注成像与HAMD评分诊断抑郁症的准确性、灵敏度、特异性、阳性预测值和阴性预测值对比无明显差异(P>0.05),脑CT灌注成像的曲线下面积为83.89,最佳诊断着色界限值为82.53%,HAMD评分的曲线下面积为84.26,最佳诊断着色界限值为87.57%;观察组与对照组受检者连线提笔数、连线错误数、视觉再生检测结果对比无明显差异(P>0.05),观察组与对照组受检者连线、言语流畅性、数字广度、数字符号检测结果对比差异显著(P<0.05);Spearman相关分析结果表明:连线提笔数、连线错误数、视觉再生与脑CT灌注参数均无明显相关性(P>0.05),连线、言语流畅性、数字广度、数字符号与rCBV、rCBF、MTT、TIP、右枕叶、左枕叶、右颞叶、左颞叶、右顶叶、左顶叶CT值无明显相关性(P>0.05),连线与右额叶、左额叶CT值呈负相关(P<0.05),言语流畅性、数字广度、数字符号与右额叶、左额叶CT值呈正相关(P<0.05)。结论:抑郁症患者的脑CT灌注成像与健康群体呈现差异,其中右额叶、左额叶差异情况最为显著,提示抑郁症患者可能存在大脑额叶功能改变,另外,抑郁症患者的大脑额叶功能与认知功能变化具有明显相关性。  相似文献   

15.
Several studies have reported an extensive regional heterogeneity in myocardial blood flow. The reported coefficients of variation for regional myocardial perfusion range from about 0.2 to 0.4 in normotensive animals. The spatial distribution of myocardial perfusion during haemorrhagic hypotension seems not to have been assessed. The goal of the present study was to determine the regional heterogeneity in myocardial blood flow within the rabbit left ventricle during normal conditions and after haemorrhagic hypotension. Radioactive microspheres were infused into the left ventricle in barbiturate anaesthetized rabbits over either 30 or 120 sec. The haemorrhagic hypotension was induced by bleeding, so that mean arterial blood pressure was reduced to about 50% of control. The left ventricles were divided into samples of about 0.025 g each. Regional heterogeneity in the blood flow was expressed as the coefficient of variation corrected for the Poisson distribution of microspheres (CVc). The CVc was 0.37 +/- 0.09 (mean +/- SD) during control and 0.41 +/- 0.11 after bleeding, the CVc obtained after bleeding being somewhat higher than during control (P < 0.05). We obtained a high correlation coefficient (tau about 0.68) between regional perfusion values at control and after bleeding which indicates a stable perfusion pattern within the myocardium. We conclude that the regional distribution of coronary blood flow within the left ventricle is markedly heterogenous during control condition and that this pattern is not changed during haemorrhagic hypotension.  相似文献   

16.
This study was performed to elucidate catecholamine release in the pulmonary circulation of isolated lungs due to the sympathetic nerve stimulation and to assess the experimental conditions which can modify the release, i.e., stimulus intensity, ventilation state of the lung and flow rate of perfusion. In artificially ventilated lungs, electrical stimulation of stellate ganglions evoked large noradrenaline efflux from the lung, but adrenaline efflux was below the detection limit, and dopamine was not detected in any case. In the unventilated preparations, the lung parenchyma were not bleached and the arterial pressure was significantly higher than in ventilated preparations. Noradrenaline efflux from the unventilated group was significantly lower than that from the ventilated preparations. The effect of the perfusion flow rate was investigated under pressure-operated ventilation. The pulmonary arterial pressure (Pa) was not varied at 5-10 ml min-1, but it was increased significantly at 20 ml min-1. Noradrenaline efflux was also increased significantly at 20 ml min-1. These results indicate that noradrenaline was the catecholamine exclusively released from pulmonary vasculature due to the sympathetic nerve stimulation, and that both ventilation and the perfusion flow rate could affect the release. The concomitant increase in arterial pressure indicates that noradrenaline efflux would be affected by the alteration in resistive small arteries. Circulatory change in these arteries is supposed to be one of the factors that modify noradrenaline release from the lungs. The analysis of noradrenaline should be a useful method to evaluate the sympathetic effect on the pulmonary vasculature.  相似文献   

17.
Although several factors are known to influence nonuniformity of ventilation, including lung mechanical properties (regional structure and compliance), external factors (chest wall, pleural pressure, heart), and ventilatory parameters (tidal and preinspiratory volume, flow rate), their relative contributions are poorly understood. We studied five excised, unperfused, canine right-middle lobes under varied levels of tidal volume (VT), thus eliminating many factors affecting heterogeneity. Multiple-breath washouts of N(2) were analyzed for anatomic dead space volume (VD(anat)), nonuniformity of N(2) washout, and nonuniformity between joined acinar regions vs. that occurring between larger joined regions. Approximately 80% of ventilation heterogeneity was found among joined acinar regions at resting levels of VT, but increasing VT reduced intra-acinar heterogeneity to about 25% of that found at resting levels. Increasing VT had essentially no effect on VD(anat) and heterogeneity among larger joined regions. The results indicate that the magnitude of VT is a major influence on the dominant intra-acinar component of ventilation heterogeneity and that VT effects on VD(anat) are likely due to perfusion and/or influences normally external to the lobar structure.  相似文献   

18.
To study the influence of blood flow on postpneumonectomy lung growth, we banded the left caudal lobe pulmonary artery of eight ferrets in such a way that blood flow to the caudal lobe did not increase when the right lung was excised 1 wk later. The fraction of the cardiac output received by the right lung before pneumonectomy was therefore directed entirely to the left cranial lobe. Three weeks after pneumonectomy the weight, volume, and protein and DNA contents of the two lobes of the left lung were measured and compared with those of five unoperated animals and eight animals after right pneumonectomy alone. Although its perfusion did not increase after pneumonectomy, the left caudal lobe of banded animals participated in compensatory growth, increasing in weight and protein and DNA contents. Although the cranial lobe of banded animals received 25% more of the cardiac output than the same lobe in pneumonectomized animals, cranial lobe volume and protein and DNA contents in the two groups were similar. Caudal lobes were smaller in banded than in simple pneumonectomized animals and tended to contain less protein, whereas the cranial lobes tended to be heavier. We conclude that increased pulmonary perfusion is not necessary for compensatory lung growth in adult ferrets, but it may modify this response.  相似文献   

19.
Previous studies in anesthetized humans positioned in the left lateral decubitus (LLD) posture have shown that unilateral positive end-expiratory pressure (PEEP) to the dependent lung produce a more even ventilation distribution and improves gas exchange. Unilateral PEEP to the dependent lung may offer special advantages during LLD surgery by reducing the alveolar-to-arterial oxygen pressure difference {(A-a)PO2 or venous admixture} in patients with thoracic trauma or unilateral lung injury. We measured the effects of unilateral PEEP on regional distribution of blood flow (Q) and ventilation (V(A)) using fluorescent microspheres in pentobarbital anesthetized and air ventilation dogs in left lateral decubitus posture with synchronous lung inflation. Tidal volume to left and right lung is maintained constant to permit the effect on gas exchange to be examined. The addition of unilateral PEEP to the left lung increased its FRC with no change in left-right blood flow distribution or venous admixture. The overall lung V(A)/Q distribution remained relatively constant with increasing unilateral PEEP. Bilateral PEEP disproportionately increased FRC in the right lung but again produced no significant changes in venous admixture or V(A)/Q distribution. We conclude that the reduced dependent lung blood flow observed without PEEP occurs secondary to a reduction in lung volume. When tidal volume is maintained, unilateral PEEP increases dependent lung volume with little effect of perfusion distribution maintaining gas exchange.  相似文献   

20.
Functional values of LogSD of the ventilation distribution (σ(V)) have been reported previously, but functional values of LogSD of the perfusion distribution (σ(q)) and the coefficient of correlation between ventilation and perfusion (ρ) have not been measured in humans. Here, we report values for σ(V), σ(q), and ρ obtained from wash-in data for three gases, helium and two soluble gases, acetylene and dimethyl ether. Normal subjects inspired gas containing the test gases, and the concentrations of the gases at end-expiration during the first 10 breaths were measured with the subjects at rest and at increasing levels of exercise. The regional distribution of ventilation and perfusion was described by a bivariate log-normal distribution with parameters σ(V), σ(q), and ρ, and these parameters were evaluated by matching the values of expired gas concentrations calculated for this distribution to the measured values. Values of cardiac output and LogSD ventilation/perfusion (Va/Q) were obtained. At rest, σ(q) is high (1.08 ± 0.12). With the onset of ventilation, σ(q) decreases to 0.85 ± 0.09 but remains higher than σ(V) (0.43 ± 0.09) at all exercise levels. Rho increases to 0.87 ± 0.07, and the value of LogSD Va/Q for light and moderate exercise is primarily the result of the difference between the magnitudes of σ(q) and σ(V). With known values for the parameters, the bivariate distribution describes the comprehensive distribution of ventilation and perfusion that underlies the distribution of the Va/Q ratio.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号