首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 803 毫秒
1.
Surface electromyography (EMG) can assess muscle recruitment patterns during cycling, but has limited applicability to studies of deep muscle recruitment and electrically stimulated contractions. We determined whether muscle recruitment timing could be inferred from MRI-measured transverse relaxation time constant (T(2)) changes and a cycle ergometer modified to vary power as a function of pedal angle. Six subjects performed 6 min of single-leg cycling under two conditions (E0°-230° and E90°-230°), which increased the power from 0°-230° and 90-230° of the pedal cycle, respectively. The difference condition produced a virtual power output from 0-180° (V0°-180°). Recruitment was assessed by integrating EMG over the pedal cycle (IEMG) and as the (post-pre) exercise T(2) change (ΔT(2)). For E0°-230°, the mean IEMG for vastus medialis and lateralis (VM/VL; 49.3 ± 3.9 mV·s; mean ± SE) was greater (P < 0.05) than that for E90°-230° (17.9 ± 1.9 mV·s); the corresponding ΔT(2) values were 8.7 ± 1.0 and 1.4 ± 0.5 ms (P < 0.05). For E0°-230° and E90°-230°, the IEMG values for biceps femoris/long head (BF(L)) were 37.7 ± 5.4 and 27.1 ± 5.6 mV·s (P > 0.05); the corresponding ΔT(2) values were 0.9 ± 0.9 and 1.5 ± 0.9 ms (P > 0.05). MRI data indicated activation of the semitendinosus and BF/short head for E0°-230° and E90°-230°. For V0°-180°, ΔT(2) was 7.2 ± 0.9 ms for VM/VL and -0.6 ± 0.6 ms for BF(L); IEMG was 31.5 ± 3.7 mV·s for VM/VL and 10.6 ± 7.0 mV·s for BF(L). MRI and EMG data indicate VM/VL activity from 0 to 180° and selected hamstring activity from 90 to 230°. Combining ΔT(2) measurements with variable loading allows the spatial and temporal patterns of recruitment during cycling to be inferred from MRI data.  相似文献   

2.
The acromial tracker is used to measure scapular rotations during dynamic movements. The method has low accuracy in high elevations and is sensitive to its attachment location on the acromion. The aim of this study was to investigate the effect of the attachment position and shoulder orientation during calibration on the tracker accuracy. The tracker was attached to one of three positions: near the anterior edge of the acromion process, just above the acromial angle and the meeting point between the acromion and the scapular spine. The scapula locator was used to track the scapula during bilateral abduction simultaneously. The locator was used to calibrate the tracker at: no abduction, 30°, 60°, 90° and 120° humerothoracic abduction. ANOVA tests compared RMS errors for different attachment positions and calibration angles. The results showed that attaching the device at the meeting point between the acromion and the scapular spine gave the smallest errors and it was best to calibrate the device at 60° for elevations ≤90°, at 120° for elevations >90° and at 90°or 120° for the full range of abduction. The accuracy of the tracker is significantly improved if attached appropriately and calibrated for the range of movement being measured.  相似文献   

3.
The accuracy of estimating the relative pose between knee replacement components, in terms of clinical motion, is important in the study of knee joint kinematics. The objective of this study was to determine the accuracy of the single-plane fluoroscopy method in calculating the relative pose between the femoral component and the tibial component, along knee motion axes, while the components were in motion relative to one another. The kinematics of total knee replacement components were determined in vitro using two simultaneous methods: single-plane fluoroscopic shape matching and an optoelectronic motion tracking system. The largest mean differences in relative pose between the two methods for any testing condition were 2.1°, 0.3°, and 1.1° in extension, abduction, and internal rotation respectively, and 1.3, 0.9, and 1.9 mm in anterior, distal, and lateral translations, respectively. For the optimized position of the components during dynamic trials, the limits of agreement, between which 95% of differences can be expected to fall, were -2.9 to 4.5° in flexion, -0.9 to 1.5° in abduction, -2.4 to 2.1° in external rotation, -2.0 to 3.9 mm in anterior-posterior translation, -2.2 to 0.4mm in distal-proximal translation and -7.2 to 8.6mm in medial-lateral translation. These mean accuracy values and limits of agreement can be used to determine whether the shape-matching approach using single-plane fluoroscopic images is sufficiently accurate for an intended motion tracking application.  相似文献   

4.
Erythronium japonicum (Liliaceae) (Japanese name, katakuri) is indigenous to Japan and adjacent Far East regions. We examined their embryo elongation, germination, and seedling emergence in relationship to the temperature. In incubators, seeds did not germinate at 20°/10° (light 12 h/dark 12 h alternating temperature), 20°, 15°, 5°, or 0°C with a 12-h light photoperiod for 200 d. They germinated at 15°/5° or 10°C, starting on day 135. If seeds were kept at 20° or at 25°/15°C before being exposed to 5°C, the seeds germinated, but if kept at 25° or 30°C they did not. Embryos at 25°/15°C grew to half the seed length without germinating; at 0° or 5°C, embryos elongated little. Embryos grew and seeds germinated when kept at 25°/15°C for 90 d and then at 5°C. In the field, seeds are dispersed in mid-June in Hokkaido and in Honshu, mid-May to mid-June. Seeds do not germinate immediately after dispersal because the embryo is underdeveloped. Embryos elongated at medium temperatures in autumn after summer heat, and germination ends in November at 8°/0°C. After germination, seedling emergence was delayed, and most seedlings were observed in early April around the snowmelt when soil cover was 2-3 mm.  相似文献   

5.
核磁共振仪获取的FID信号采用APSL(自动相位校正算法)进行相位矫正算法时,当相角偏差为45°、135°.225°和315°,计算的相角误差很大。提出了一种改进的APSL方法,通过人为地将原始谱峰相角改变±45°,并在不同的相角偏差下计算相位角,然后对三个角度下的结果进行分析以得到误差最小的相位角。  相似文献   

6.
7.
Conclusions about normal and pathologic shoulder motion are frequently made from studies using skin surface markers, yet accuracy of such sensors representing humeral motion is not well known. Nineteen subjects were investigated with flock of birds electromagnetic sensors attached to transcortical pins placed into the scapula and humerus, and a thermoplastic cuff secured on the arm. Subjects completed two repetitions of raising and lowering the arm in the sagittal, scapular and coronal planes, as well as shoulder internal and external rotation with the elbow at the side and abducted to 90°. Humeral motion was recorded simultaneously from surface and bone fixed sensors. The average magnitude of error was calculated for the surface and bone fixed measurements throughout the range of motion. ANOVA tested for differences across angles of elevation, raising and lowering, and differences in body mass index. For all five motions tested, the plane of elevation rotation average absolute error ranged from 0-2°, while the humeral elevation rotation average error ranged from 0-4°. The axial rotation average absolute error was much greater, ranging from 5° during elevation motions to approaching 30° at maximum excursion of internal/external rotation motions. Average absolute error was greater in subjects with body mass index greater than 25. Surface sensors are an accurate way of measuring humeral elevation rotations and plane of elevation rotations. Conversely, there is a large amount of average error for axial rotations when using a humeral cuff to measure glenohumeral internal/external rotation as the primary motion.  相似文献   

8.
The purpose of this study was to investigate the hemodynamic effect of variations in the angulations of the left coronary artery, based on simulated and realistic coronary artery models. Twelve models consisting of four realistic and eight simulated coronary artery geometries were generated with the inclusion of left main stem, left anterior descending and left circumflex branches. The simulated models included various coronary artery angulations, namely, 15°, 30°, 45°, 60°, 75°, 90°, 105° and 120°. The realistic coronary angulations were based on selected patient's data with angles ranging from narrow angles of 58° and 73° to wide angles of 110° and 120°. Computational fluid dynamics analysis was performed to simulate realistic physiological conditions that reflect the in vivo cardiac hemodynamics. The wall shear stress, wall shear stress gradient, velocity flow patterns and wall pressure were measured in simulated and realistic models during the cardiac cycle. Our results showed that a disturbed flow pattern was observed in models with wider angulations, and wall pressure was found to reduce when the flow changed from the left main stem to the bifurcated regions, based on simulated and realistic models. A low wall shear stress gradient was demonstrated at left bifurcations with wide angles. There is a direct correlation between coronary angulations and subsequent hemodynamic changes, based on realistic and simulated models. Further studies based on patients with different severities of coronary artery disease are required to verify our results.  相似文献   

9.
The purpose of this study was to analyze the hydrodynamic characteristics of a realistic model of an elite swimmer hand/forearm using three-dimensional computational fluid dynamics techniques. A three-dimensional domain was designed to simulate the fluid flow around a swimmer hand and forearm model in different orientations (0°, 45°, and 90° for the three axes Ox, Oy and Oz). The hand/forearm model was obtained through computerized tomography scans. Steady-state analyses were performed using the commercial code Fluent. The drag coefficient presented higher values than the lift coefficient for all model orientations. The drag coefficient of the hand/forearm model increased with the angle of attack, with the maximum value of the force coefficient corresponding to an angle of attack of 90°. The drag coefficient obtained the highest value at an orientation of the hand plane in which the model was directly perpendicular to the direction of the flow. An important contribution of the lift coefficient was observed at an angle of attack of 45°, which could have an important role in the overall propulsive force production of the hand and forearm in swimming phases, when the angle of attack is near 45°.  相似文献   

10.
The research to be reported examines the concept of efficiency, defined as the relation of metabolic energy expended to mechanical work done. The development of movement coordination was investigated in the context of the hypothesis that an increase in coordination would be accompanied by a parallel reduction in overall energy expenditure, relative to the increase in energy expenditure demanded by improvements in work output. The task involved learning to make cyclical, slalom-like, ski movements on a ski apparatus. Development of coordination was indexed by changes in the timing of forcing while on-line measurements of oxygen consumption were used as indices of energy expenditure. Six female volunteers served as subjects in nine training sessions. The change in the coordination pattern, between the subject and the apparatus, as indexed by the development of the phase lag, was paralleled by an improvement in efficiency. It was concluded that learning the skill used in this study involves a search by the system for perception-action couplings (phase relations in the present study) that require minimal energy expenditure. Received: 22 September 1998 / Accepted in revised form: 20 April 1999  相似文献   

11.
Recent studies show that minor and major centroidal axes (CA) of long bone cross sections provide valuable predictions of prevailing loading patterns in age and treatment matched cohorts of animals. Furthermore, using CA, we recently showed that the degree of mineralization and area of woven bone laid down in the first two weeks after creation of a critical sized bone defect relate inversely and correlate significantly to loading patterns. Here, we aim to determine how closely independent measures of the spatial distribution of bone apposition determined using the major and minor CA as reference points correlate to those using anatomically defined axes as reference points. In histological sections from the previous study, we found no statistically significant difference between the anatomical and centroidal axes with respect to the centroid location or axis rotation, but there is a significant albeit small difference in the average distance between centroids. Outcome measures calculated in areas of bone defined by 15°, 30°, 45°, 60°, or 90° sectors when using the CA differ less than 5% from those calculated using anatomical axes as reference points. Hence, the major and minor CA provide objective reference points for comparison of mechanobiological outcome measures between animals in matched cohorts. Calculation of major and minor CA is automated, which reduces the potential for observer bias. A major advantage of using the major and minor CA as reference points is that it allows for direct relation of outcome measures to loading patterns in age and treatment matched cohorts, ultimately providing a tool to test mechanobiological hypotheses on histological cross sections of bone.  相似文献   

12.
Neurophysiological studies in monkeys show that activity of neurons in primary cortex (M1), pre-motor cortex (PMC), and cerebellum varies systematically with the direction of reaching movements. These neurons exhibit preferred direction tuning, where the level of neural activity is highest when movements are made in the preferred direction (PD), and gets progressively lower as movements are made at increasing degrees of offset from the PD. Using a functional magnetic resonance imaging adaptation (fMRI-A) paradigm, we show that PD coding does exist in regions of the human motor system that are homologous to those observed in non-human primates. Consistent with predictions of the PD model, we show adaptation (i.e., a lower level) of the blood oxygen level dependent (BOLD) time-course signal in M1, PMC, SMA, and cerebellum when consecutive wrist movements were made in the same direction (0° offset) relative to movements offset by 90° or 180°. The BOLD signal in dorsolateral prefrontal cortex adapted equally in all movement offset conditions, mitigating against the possibility that the present results are the consequence of differential task complexity or attention to action in each movement offset condition.  相似文献   

13.
We report a theoretical study of second-harmonic generation (SHG) from the collagen fibrils which have a tilt angle Φ between their axes with the plane of the polarization angle α of the linearly polarized focused light. The effects of Φ as well as α on SHG emission have been investigated. Our results show that the total strength of SHG electrical field (E(2ω)) and power (P(2ω)) reach their maximal values as Φ locates at a certain angle, here it is around 27° under all demonstrated α. When Φ < 27°, E(2ω) and P(2ω) gradually increase to their maximal value, while when Φ > 27°, they quickly drops. Specially, E(2ω) and P(2ω) are almost undetectable when Φ ≥ 45°. Also, Φ influences the distribution pattern of E(2ω), P(2ω) and their parallel (E(2ω,p), P(2ω,p)) and perpendicular (E(2ω,s), P(2ω,s)) components, such as the number of emission lobes and shape. α has unevenly impact on E(2ω) and P(2ω), the far deviation of α from x axis induce much great decrease of E(2ω) and P(2ω). α = 45° has special influence on the distribution pattern of E(2ω,s), E(2ω), P(2ω,s) as well as P(2ω) compared to those of α = 0° and 90°.  相似文献   

14.
15.
The effect of low proprioceptive, tactile, and support afferentation on visual-manual tracking was determined using a five-day horizontal dry immersion, which provided support deprivation, as well as minimization of muscle activity and proprioceptive afferentation, simulating the physiological effects of microgravity. Hand-eye motor coordination was studied in the 13 subjects participating in the experiment with five-day dry immersion who tracked the jumpy and smooth movements of a point visual stimulus (linear and pendulum-like; horizontal and vertical; circular, clockwise and counterclockwise). Ocular movements were recorded using binocular electrooculography; and manual motions were recorded using a joystick with a biological visual feedback, when one of the two stimuli on the screen showed the current joystick tilt. Computerized stimulation was provided using virtual reality goggles. The following parameters were evaluated: the latent and total reaction time; the amplitudes and velocities of the eye and hand movements; and the coefficients of effectiveness (amplitude ratio) and the gain (velocity ratio). The examinations were performed before immersion, after 3 h of immersion, on days 3 and 5 of immersion, during the first hours after the termination of immersion, and three days after the immersion (in all subjects); and on days 5–7 after the immersion (in four subjects). It was shown that support deprivation and minimization of proprioceptive afferentation affected ocular tracking to a larger extent than the accuracy of manual movements following the visual stimulus. It was found that, in all subjects, manual tracking, which did not significantly change during the test sessions, was more accurate than visual tracking; in contrast, the accuracy of visual tracking changed noticeably both in the course of dry immersion and after its termination.  相似文献   

16.
Spatial interactions between consecutive movements are often attributed to inhibition of return (IOR), a phenomenon in which responses to previously signalled locations are slower than responses to unsignalled locations. In two experiments using peripheral target signals offset by 0°, 90°, or 180°, we show that consecutive saccadic (Experiment 1) and reaching (Experiment 3) responses exhibit a monotonic pattern of reaction times consistent with the currently established spatial distribution of IOR. In contrast, in two experiments with central target signals (i.e., arrowheads pointing at target locations), we find a non-monotonic pattern of reaction times for saccades (Experiment 2) and reaching movements (Experiment 4). The difference in the patterns of results observed demonstrates different behavioral effects that depend on signal type. The pattern of results observed for central stimuli are consistent with a model in which neural adaptation is occurring within motor networks encoding movement direction in a distributed manner.  相似文献   

17.
 Various stability features of bimanual rhythmic coordination, including phase transitions, have been modeled successfully by means of a one-dimensional equation of motion for relative phase obeying a gradient dynamics, the Haken-Kelso-Bunz model. The present study aimed at assessing pattern stability for stationary performance and estimating the model parameters (a, b, and Q) for the stochastic extension of this model. Estimates of a and b allowed for reconstruction of the potential defining the gradient dynamics. Two coordination patterns between the forearms (in-phase, anti-phase) were performed at seven different frequencies. Model parameters were estimated on the basis of an exponential decay parameter describing the relaxation behavior of continuous relative phase following a mechanical perturbation. Variability of relative phase and relaxation time provided measures of pattern stability. Although the predicted inverse relation between pattern stability and movement frequency was observed for the lower tempo conditions, it was absent for the higher tempos, reflecting the influence of task constraints. No statistically significant differences in stability were observed between the two coordination modes, indicating the influence of intention. The reconstructed potential reflected the observed stability features, underscoring the adequacy of the parameter estimations. The relaxation process could not be captured adequately by means of a simple exponential decay function but required an additional oscillatory term. In accordance with previous assumptions, noise strength Q did not vary as a function of movement frequency. However, systematic differences in Q were observed between the two coordination modes. The advantages and (potential) pitfalls of using stationary performance of single patterns to examine the stability features of a bistable potential were discussed. Received: 12 July 1999 / Accepted in revised form: 14 April 2000  相似文献   

18.
For more than 20 years, coordination dynamics have provided research on human movement science with new views about the nonlinear relationships between behavioral and neural dynamics. A number of studies across various experimental settings including bimanual, postural or interpersonal coordination, and also coordination between movements of a limb and an external event in the environment revealed the self-organized nature of human coordination. Here we review an extensive body of literature - in the human movement science and the neuroscience fields - that has investigated the coordination dynamics of brain and behavior when individuals are involved in two rhythmic coordination patterns: synchronization (on-the-beat movements) and syncopation (in-between beats movements). When the frequency of movement approaches 2 Hz, the syncopation mode is destabilized and synchronization is spontaneously adopted. The abrupt change between the two patterns illustrates a phenomenon known as non-equilibrium phase transition. Phase transitions offer a novel entry point into the investigation of pattern formation (and dissolution) at both the behavioral and the cerebral levels as they illustrate the loss of stability of the system. Brain imaging methods (MEG, EEG and fMRI) were used to reveal the neural signatures of (in)stability underlying the differences between behavioral coordination patterns, and pointed at the role of self-organization and metastability principles in brain functioning. Relationships between behavioral and brain dynamics can therefore be investigated within a unified empirical and theoretical framework.  相似文献   

19.
The most recent non-invasive methods for the recording of scapular motion are based on an acromion marker (AM) set and a single calibration (SC) of the scapula in a resting position. However, this method fails to accurately measure scapular kinematics above 90° of arm elevation, due to soft tissue artifacts of the skin and muscles covering the acromion. The aim of this study was to evaluate the accuracy, and inter-trial and inter-session repeatability of a double calibration method (DC) in comparison with SC. The SC and DC data were measured with an optoelectronic system during arm flexion and abduction at different angles of elevation (0-180°). They were compared with palpation of the scapula using a scapula locator. DC data was not significantly different from palpation for 5/6 axes of rotation tested (Y, X, and Z in abduction and flexion), where as SC showed significant differences for 5/6 axes. The root mean square errors ranged from 2.96° to 4.48° for DC and from 6° to 9.19° for SC. The inter-trial repeatability was good to excellent for SC and DC. The inter-session repeatability was moderate to excellent for SC and moderate to good for DC. Coupling AM and DC is an easy-to-use method, which yields accurate and reliable measurements of scapular kinematics for the complete range of arm motion. It can be applied to the measurement of shoulder motion in many fields (sports, orthopaedics, and rehabilitation), especially when large ranges of arm motion are required.  相似文献   

20.
Voltage-gated K(+) channels composed of Kv7.2 and Kv7.3 are the predominant contributors to the M-current, which plays a key role in controlling neuronal activity. Various lines of evidence have indicated that Kv7.2 and Kv7.3 form a heteromeric channel. However, the subunit stoichiometry and arrangement within this putative heteromer are so far unknown. Here, we have addressed this question using atomic force microscopy imaging of complexes between isolated Kv7.2/Kv7.3 channels and antibodies to epitope tags on the two subunits, Myc on Kv7.2 and HA on Kv7.3. Initially, tsA 201 cells were transiently transfected with equal amounts of cDNA for the two subunits. The heteromer was isolated through binding of either tag to immunoaffinity beads and then decorated with antibodies to the other tag. In both cases, the distribution of angles between pairs of bound antibodies had two peaks, at around 90° and around 180°, and in both cases the 90° peak was about double the size of the 180° peak. These results indicate that the Kv7.2/Kv7.3 heteromer generated by cells expressing approximately equal amounts of the two subunits assembles as a tetramer with a predominantly 2:2 subunit stoichiometry and with a random subunit arrangement. When the DNA ratio for the two subunits was varied, copurification experiments indicated that the subunit stoichiometry was variable and not fixed at 2:2. Hence, there are no constraints on either the subunit stoichiometry or the subunit arrangement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号