首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, uniform and stable multi-walled carbon nanotubes (MWCT) and chemically reduced graphene (GR) composite electrode interface was fabricated by using layer-by-layer assembly method. The performances of these GR-MWCT assembled electrode interfaces were studied by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). It was demonstrated that the assembled composite film significantly improved the interfacial electron transfer rate compared with that of GR or MWCT modified electrode. Based on the GR-MWCT assembled interface, a sandwich-type electrochemical immunosensor was constructed using human IgG as a model target. In this assay, human IgG was fixed as the target antigen, the HRP-conjugated IgG as the probing antibody and hydroquinone as the electron mediator. The detection limit of the immunosensor was 0.2 ng mL(-1) (signal-to-noise ratio of 3). A good linear relationship between the current signals and the concentrations of Human IgG was achieved from 1 ng mL(-1) to 500 ng mL(-1). Moreover, this electrochemical immunosensor exhibited excellent selectivity, stability and reproducibility, and can be used to accurately detect IgG concentration in human serum samples. The results suggest that the electrochemical immunosensor based on GR-MWCT assembled composite will be promising in the point-of-care diagnostics application of clinical screening of multiple diseases.  相似文献   

2.
An electrochemical impedimetric immunosensor was developed for ultrasensitive determination of insulin-like growth factor-1 (IGF-1) based on immobilization of a specific monoclonal antibody on gold nanoparticles (GNPs) modified gold electrode. Self-assembly of colloidal gold nanoparticles on the gold electrode was conducted through the thiol groups of 1,6-hexanedithiol (HDT) monolayer as a cross linker. The redox reactions of [Fe(CN)(6)](4-)/[Fe(CN)(6)](3-) on the electrode surface was probed for studying the immobilization and determination processes, using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The interaction of antigen with grafted antibody recognition layer was carried out by soaking the modified electrode into antigen solution at 37°C for 3 h. The immunosensor showed linearity over 1.0-180.0 pg mL(-1) and the limit of detection was 0.15 pg mL(-1). The association constant between IGF-1 and immobilized antibody was calculated to be 9.17×10(11) M(-1). The proposed method is a useful tool for screening picogram amounts of IGF-1 in clinical laboratory as a diagnostic test.  相似文献   

3.
The development of immunosensors with high sensitivity and specificity in detecting the pathogenic or physiologically relevant molecules in the body, offers a powerful opportunity in early diagnosis and treatment of diseases. In this study, we developed a new competitive immunosensor with employing antibody (Ab) labeled AuNP (Ab-AuNP) and PVA modified screen-printed carbon electrode (SPCE) surface to detect the urine albumin. Field emission scanning electron microscopy (FE-SEM) of modified electrode showed a suitable and stable attachment between HSA antigen- mAb and AuNP. Cyclic voltammetric (CV) method demonstrated that modification process was well performed. Electrochemical measurements including differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were employed for quantitative antigen detection. The electrochemical measurements performed with other proteins mixed with samples demonstrated a high specificity and selectivity for this biosensor in detecting the HSA. In optimal conditions, the immunosensor could detect HSA in a high linear range (from 2.5 to 200 μg/mL) with a low detection limit of 25 ng/mL. This new strategy could be improved and applied to detect the other antigen.  相似文献   

4.
Wei Q  Zhao Y  Xu C  Wu D  Cai Y  He J  Li H  Du B  Yang M 《Biosensors & bioelectronics》2011,26(8):3714-3718
Nanoporous gold (NPG) film modified electrode for the construction of novel label-free electrochemical immunosensor for ultrasensitive detection of cancer biomarker prostate specific antigen (PSA) is described. Due to its high conductivity, large surface area, and good biocompatibility, NPG film modified electrode was used for the adsorption of anti-PSA antibody (Ab). The sensing signal is based on the monitoring of the electrode's current response towards K(3)Fe(CN)(6), which is extremely sensitive to the formation of immunocomplex within the nanoporous film. Under optimum conditions, the amperometric signal decreases linearly with PSA concentration (0.05-26 ng/mL), resulting in a low limit of detection (3 pg/mL). We demonstrated the application of the novel immunosensor for the detection of PSA in real sample with satisfactory results.  相似文献   

5.
In this paper, a novel electrochemical immunosensor for the determination of casein based on gold nanoparticles and poly(L-Arginine)/multi-walled carbon nanotubes (P-L-Arg/MWCNTs) composite film was proposed. The P-L-Arg/MWCNTs composite film was used to modify glassy carbon electrode (GCE) to fabricate P-L-Arg/MWCNTs/GCE through electropolymerization of L-Arginine on MWCNTs/GCE. Gold nanoparticles were adsorbed on the modified electrode to immobilize the casein antibody and to construct the immunosensor. The stepwise assembly process of the immunosensor was characterized by cyclic voltammetry and differential pulse voltammetry. Results demonstrated that the peak currents of [Fe(CN)(6)](3-/4-) redox pair decreased due to the formation of antibody-antigen complex on the modified electrode. The optimization of the adsorption time of gold nanoparticles, the pH of supporting electrolyte and the incubation time were investigated in details. Under optimal conditions, the peak currents obtained by DPV decreased linearly with the increasing casein concentrations in the range from 1 × 10(-7) to 1 × 10(-5) g mL(-1) with a linear coefficiency of 0.993. This electrochemical immunoassay has a low detection limit of 5 × 10(-8) g mL(-1) and was successfully applied to the determination of casein in cheese samples.  相似文献   

6.
A novel amperometric immunosensor for the detection of the p24 antigen (p24Ag) from HIV-1 was constructed using gold nanoparticles (GNP), multi-walled carbon nanotubes (MWCNTs), and an acetone-extracted propolis film (AEP). First, amino-functionalized MWCNTs (MWCNTNH?) were prepared and dispersed in an HAuCl? solution to synthesize GNPs in situ. Next, the GNP/CNT/AEP nanocomposite was prepared by mixing an AEP solution and the GNP/CNT powder. The nanocomposite was dripped onto a gold electrode (GE), and then p24 antibody (anti-p24 Ab) was immobilized on the resulting modified gold electrode to construct the immunosensor. The assembly process was characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The factors that were likely to influence the performance of the proposed immunosensor were studied in detail. Under optimal conditions, the proposed immunosensor exhibited good electrochemical sensitivity to the presence of p24 in a concentration range of 0.01 to 60.00 ng/mL, with a relatively low detection limit of 0.0064 ng/mL (S/N = 3). Moreover, the proposed immunosensor showed a rapid (≤ 18 s) and highly sensitive amperometric response (0.018 and 1.940 μA/ng/mL) to p24 with acceptable stability and reproducibility.  相似文献   

7.
A novel strategy for the fabrication of sensitive immunosensor to detect alpha-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml(-1) with a detection limit of 0.6 ng ml(-1). The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

8.
This paper describes a novel enzymatic amplification strategy for ultrasensitive electrochemical immunosensing. This approach utilizes glucose oxidase for the enzymatic deposition of gold nanoparticles onto an indium tin oxide (ITO) electrode surface using a novel gold developer solution consisting of 20 mM of glucose, 20 mM of NaSCN, 0.5 M of p-benzoquinone (PBQ) and 1 mM of AuCl(4)(-) dissolved in 0.1 M of pH 7.5 phosphate buffer solution. The amount of gold deposited was quantified electrochemically by monitoring the reduction of gold oxide in an aqueous solution of 0.5 M of H(2)SO(4), which was correlated to the amount of antigens in the solution. The effectiveness of this strategy was demonstrated experimentally through the construction of an immunosensor for the detection of mouse IgG using a sandwich immunoassay in a linear dynamic range of 5 pg/ml to 50 ng/ml. A good mean apparent recovery in the range of 88-102% was obtained over the entire linear dynamic range of the sensor response in the serum samples. This suggested that the immunosensor would be useful for the testing of proteins in real clinical samples.  相似文献   

9.
The long-term stability of sensing interfaces is an important issue in biosensor fabrication. A novel stable gold nanoparticle (AuNP)-modified glassy carbon (GC) electrode interface (GC-Ph-AuNP)-based biosensor for detecting carcinoembryonic antigen (CEA) was developed. GC electrodes were modified with 1,4-phenylenediamine to form a stable layer, and then AuNPs were bound onto the GC electrodes through CAu bonds. Anti-CEA was directly adsorbed on AuNPs fixed on the GC electrode. The linear range of the immunosensor was from 10 fg to 100 ng mL(-1) with a detection limit of 3 fg mL(-1) (S/N=3). The current of the immunosensor was increased by 4% after one month. The GC-Ph-AuNP immunosensor showed high sensitivity, a wide linear range, low detection limit, and good selectivity and stability. The immobilization method of the immunosensor could be widely applied to construct other immunosensors.  相似文献   

10.
This paper describes the combination of electrochemical immunosensor using gold nanoparticles (GNPs)/carbon nanotubes (CNTs) hybrids platform with horseradish peroxidase (HRP)-functionalized gold nanoparticle label for the sensitive detection of human IgG (HIgG) as a model protein. The GNPs/CNTs nanohybrids covered on the glass carbon electrode (GCE) constructed an effective antibody immobilization matrix and made the immobilized biomolecules hold high stability and bioactivity. Enhanced sensitivity was obtained by using bioconjugates featuring HRP labels and secondary antibodies (Ab2) linked to GNPs at high HRP/Ab2 molar ratio. The approach provided a linear response range between 0.125 and 80 ng/mL with a detection limit of 40 pg/mL. The immunosensor showed good precision, acceptable stability and reproducibility and could be used for the detection of HIgG in real samples, which provided a potential alternative tool for the detection of protein in clinical laboratory.  相似文献   

11.
A new amperometric immunosensor for the determination of carcinoembryonic antigen (CEA) was constructed. First, the uniform nanomultilayer film was fabricated via layer-by-layer (LBL) assembly of positively charged carbon nanotubes wrapped by poly(diallyldimethylammonium chloride) and negatively charged poly(sodium-p-styrene-sulfonate), which could provide a high accessible surface area and a biocompatible microenvironment. Subsequently, gold nanoclusters were electrodeposited on the electrode to immobilize anti-CEA. The fabricated process and electrochemical behaviors of the immunosensor were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor could detect CEA in two linear ranges from 0.1 to 2.0 ng mL−1 and from 2.0 to 160.0 ng mL−1, with a detection limit of 0.06 ng mL−1.  相似文献   

12.
Two generic, fast, sensitive and novel electrochemical immunosensors have been developed. Initially, a layer of plasma-polymerized Nafion film (PPF) was deposited on the platinum electrode surface, then positively charged tris(2,2'-bipyridyl)cobalt(III) (Co(bpy)(3)(3+)) and negatively charged gold nanoparticles were assembled on the PPF-modified Pt electrode by layer-by-layer technique. Finally, hepatitis B surface antibody (HBsAb) was electrostatically adsorbed on the gold nanoparticles surface. Electrochemical behavior of the {Au/Co(bpy)(3)(3+)}(n) multilayer film-modified electrodes was studied. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS) were adopted to monitor the regular growth of the multilayer films. The performance and factors influencing the performance of the resulting immunosensors were studied in detail. The multilayer film-modified immunosensor was used for hepatitis B surface antigen (HBsAg) determination via the amperometric and potentiometric immunosensor systems, and both systems provided the same linear ranges from 0.05 to 4.5 microg/mL with different detection limits for the amperometric system 0.005 microg/mL and for the potentiometric system 0.015 microg/mL. The immunosensors were used to analyse HBsAg in human serum samples. Analytical results of clinical samples show that the developed immunoassay is comparable with the enzyme-linked immunosorbent assays (ELISAs) method, implying a promising alternative approach for detecting HBsAg in the clinical diagnosis. In addition, the multilayer films also showed better stability for 1 month at least.  相似文献   

13.
A simple and sensitive label-free electrochemical immunoassay electrode for detection of carcinoembryonic antigen (CEA) has been developed. CEA antibody (CEAAb) was covalently attached on glutathione (GSH) monolayer-modified gold nanoparticle (AuNP) and the resulting CEAAb-AuNP bioconjugates were immobilized on Au electrode by electro-copolymerization with o-aminophenol (OAP). Electrochemical impedance spectroscopy and cyclic voltammetry studies demonstrate that the formation of CEA antibody-antigen complexes increases the electron transfer resistance of [Fe(CN)(6)](3-/4-) redox pair at the poly-OAP/CEAAb-AuNP/Au electrode. The use of CEA antibody-AuNP bioconjugates and poly-OAP film could enhance the sensitivity and anti-nonspecific binding of the resulting immunoassay electrode. The preliminary application of poly-OAP/CEAAb-AuNP/Au electrode for detection of CEA was also evaluated.  相似文献   

14.
In this work, the direct electrochemical determination of poly-histidine tagged proteins using immunosensor based on anti-His (C-term) antibody immobilized on gold electrodes modified with 1,6-hexanedithiol, gold colloid particles or gold nanorods is described. The recombinant histidine-tagged silk proteinase inhibitor protein (rSPI2-His(6)) expressed in Pichia system selected as antigen for this immonosensor. An electrochemical impedance spectroscopy was used as label free detection technique for immune conjugation. The gold nanorods modified electrode layer showed better analytical response than gold nano particles. The linear calibration range was observed between 10pg/ml and 1ng/ml with limit of detection 5pg/ml (S/N=3). Up to four successive assay cycles with retentive sensitivity were achieved for the immunosensors regenerated with 0.2M glycine-HCl buffer, pH 2.8. The performance of this immnosensor were compared with immuoblotting techniques.  相似文献   

15.
Multilayer immobilization of antibody and redox polymer molecules on a gold electrode was achieved, as a strategy for the potential development of an amperometric immunosensor. The step-by-step assembly of antibiotin IgG on Os(bpy)(2)ClPyCH(2)NH poly(allylamine) redox polymer (PAH-Os) adsorbed on thiolated gold electrodes was proved by quartz crystal microbalance (QCM) and atomic force microscopy (AFM) experiments, confirming the electrochemical evidence. The increase of redox charge during the layer-by-layer deposition demonstrated that charge propagation within the layers is feasible. The multilayer structure proved to be effective for the molecular recognition of horseradish peroxidase-biotin conjugate (HRP-biotin), as confirmed by the QCM measurements and the electrocatalytic reduction current obtained upon H(2)O(2) addition. The catalytic current resulting from PAH-Os mediation was shown to increase with the number of assembled layers. Furthermore, the inventory of IgG molecules on the supramolecular self-assembled structure and the specific and non-specific binding of HRP-biotin conjugate were confirmed by the QCM transient studies, giving information on the kinetics of IgG deposition and HRP-biotin conjugate binding to the IgG.  相似文献   

16.
Bioaffinity sensors need to be rapid, specific, and highly sensitive. To realize these features, electrodes that can elicit high electrochemical performance are necessary. In this study, we developed nanorod array electrode and performed cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) experiments to study the interfacial properties of the nanorod array electrode with Fe(CN)(6)(3-/4-) as the redox molecules. Results showed that both the CV and EIS measurements captured very well the resistive and capacitive changes due to the adsorption of functionalizing molecules and the coupling between avidin and biotin. The EIS measurements were more sensitive in discriminating small changes caused by the surface adsorption of various molecules. The use of avidin-functionalized gold nanorod modified electrodes had led to much increased detection sensitivity along with a detection-limit as low as 1 ng/mL of biotin.  相似文献   

17.
A novel reagentless immunosensor was fabricated by immobilization of redox mediator 3,3',5,5'-tetramethylbenzidine (TMB) on the Nafion (Nf) film modified glassy carbon electrode. Gold nanoparticles were assembled onto the TMB/Nafion film modified electrode to provide active sites for the immobilization of antibody molecules. The antibody (anti-MIgG), in the present study, was fixed on the electrode for the rapid detection of antigen molecules (MIgG as a model analyte). The results showed that the immunosensor based on the immobilized TMB redox mediator exhibited good electrochemical response. A good linear relationship between peak current and the concentration of the MIgG was obtained in the concentration range from 4 to 120ng/mL. The detection limit was estimated to be 1ng/ml. Under the optimized conditions, the immunosensor exhibits good sensitivity, reproducibility and stability.  相似文献   

18.
We used colloidal Au to enhance the amount of antibody immobilized on a gold electrode and ultimately monitored the interaction of antigen-antibody by impedance measurement. Self-assembly of 6 nm (diameter) colloidal Au onto the self-assembled monolayers (SAMs) of 4-aminothiophenol modified gold electrode resulted in an easier attachment of antibody. The redox reactions of [Fe(CN)6](4-)/[Fe(CN)6](3-) on the gold surface were blocked due to the procedures of self-assembly of 4-aminothiophenol and antibody immobilization, which were investigated by cyclic voltammetry and impedance spectroscopy. The interaction of antigen with grafted antibody recognition layers was carried out by soaking the modified electrode into a phosphate buffer at pH 7.4 with various concentrations of antigen at 37 degrees C for 30 min. The antibody recognition layers and their interactions with various concentrations of antigen could be detected by measurements of the impedance change. The results show that this method has good correlation for detection of Hepatitis B virus surface antigen in the range of 0.5-200 microg/l and a detection limit of about 50 ng/l.  相似文献   

19.
A sensitive amperometric immunosensor for carcinoembryonic antigen (CEA) was prepared. Firstly, a porous nano-structure gold (NG) film was formed on glassy carbon electrode (GCE) by electrochemical reduction of HAuCl4 solution, then nano-Au/Chit composite was immobilized onto the electrode because of its excellent membrane-forming ability, and finally the anti-CEA was adsorbed onto the surface of the bilayer gold nanoparticles to construct an anti-CEA/nano-Au/Chit/NG/GCE immunosensor. The characteristics of the modified electrode at different stages of modification were studied by cyclic voltammetry (CV). The gold colloid, chitosan and nano-Au/Chit were characterized by transmission electron microscopy and UV–vis spectroscopy. In addition, the performances of the immunosensor were studied in detail. The resulting immunosensor offers a high-sensitivity (1310 nA/ng/ml) for the detection of CEA and has good correlation for detection of CEA in the range of 0.2 to 120.0 ng/ml with a detection limit of 0.06 ng/ml estimated at a signal-to-noise ratio of 3. The proposed method can detect the CEA through one-step immunoassay and would be valuable for clinical immunoassay.  相似文献   

20.
Wang S  Wu Z  Qu F  Zhang S  Shen G  Yu R 《Biosensors & bioelectronics》2008,24(4):1026-1032
In this paper, we report a kind of ordered 3D Au nano-prickle clusters by directly electrodeposited on glassy carbon electrode utilizing the spatial obstruction/direction of the polycarbonate membrane. The proposed 3D nanoclusters are applied to fabricate a sandwich-type electrochemical immunosensor with human IgG as a model analyte. The electrodeposited Au nanoclusters build direct electrical contact and immobilization interface for protein molecules, which do not need post-modification and positioning. Scanning electron microscopy, cyclic voltammetry and alternating current impedance spectroscopy were used to investigate the properties of the modified interface. The deposited Au nanoclusters are stable with good biocompatibility, large specific surface area and high electron exchange capability. Under the optimized experimental conditions, a wide linear range from 1.0 to 10000.0 ng/mL was reached with a detection limit of 0.5 ng/mL. The calibration curve fits a second-order polynomial equation very well (R(2)=0.9914). The developed immunosensor based on Au nano-prickle clusters possesses advantages such as simple fabrication, fast response, low detection limit, wide linear range, easy regeneration, excellent reproducibility and long stability. To our knowledge, the Au nanostructure of special ordered 3D nano-prickle clusters is new for electrochemical immunosensor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号