1.
A miniaturized glucose biosensor in which glucose oxidase (GOD) and poly(p-phenylenediamine) (poly-PPD) were coimmobilized at the surface of a platinum microdisk electrode was developed and used successfully for amperometric determination of glucose. The performance of sensors prepared at different monomer concentrations and polymerization potentials with different media was investigated in detail. It was found that similarly to poly(o-phenylenediamine) (poly-OPD), (poly-PPD) noticeably eliminated the electrochemical interference of ascorbic acid, uric acid, and l-cysteine. The amperometric response of glucose with the biosensor under optimal conditions exhibited a linear relationship in the range of 5.0 x 10(-5) to 3.0 x 10(-3) M with correlation coefficient 0.9995. According to the Michaelis-Menten equation, the apparent Michaelis constant for glucose and the maximum steady-state current density of the poly-PPD/GOD-modified microelectrode were 3.94 mM and 607.5 microA cm(-2), respectively. The current density of the sensor responding to glucose in the linear range can reach 160 microA cm(-2) mM(-1), which is far greater than that obtained using poly-OPD and poly(phenol) film. In addition, the stability of the sensor was examined over a 2-month period.  相似文献   

2.
A multifunctional bio-sensing chip was designed based on the electrochemiluminescent (ECL) detection of enzymatically produced hydrogen peroxide. Six different oxidases specific for choline, glucose, glutamate, lactate, lysine and urate were non-covalently immobilised on imidodiacetic acid chelating beads (glucose oxidase only) or on diethylaminoethyl (DEAE) anion exchanger beads, and spotted on the surface of a glassy carbon foil (25 mm(2) square), entrapped in PVA-SbQ photopolymer. The chip measurement was achieved by applying during 3 min a +850 mV potential between the glassy carbon electrode and a platinum pseudo-reference, while capturing a numeric image of the multifunctional bio-sensing chip with a CCD camera. The use of luminol supporting beads (DEAE-Sepharose) included in the sensing layer was shown to enable the achievement of spatially well defined signals, and to solve the hydrogen peroxide parasite signal which appeared between contiguous spots using luminol free in solution. The detection limits of the different biosensor were found to be 1 microM for glutamate, lysine and uric acid, 20 microM for glucose and 2 microM for choline and lactate. The detection ranges were 1-25 microM (uric acid), 1 microM-0.5 mM (glutamate and lysine), 20 microM-2 mM (glucose) and 2 microM-0.2 mM (choline and lactate). The ECL chip was used for the detection of glucose, lactate and uric acid in human serum matrix. Good correlations between measured and expected values were found without the need of internal calibration of the sample, demonstrating the potentiality of the ECL multifunctional bio-sensing chip.  相似文献   

3.
Detection of the common electrochemical interferents, ascorbic acid and hydrogen peroxide, using a SIRE (Sensors based on Injection of the Recognition Element) technology based biosensor in reverse mode operation is reported. The differential measuring principle employed in the SIRE biosensor during operation in reverse mode is such that the sample is measured first in the presence of enzyme (yielding matrix signal only), and then measured again in the absence of enzyme (yielding signal from matrix+analyte). Subtraction of the signal obtained in the presence of enzyme from the signal obtained in the absence of enzyme gives a specific signal for the analyte only and correlates directly to its concentration in solution. The linear range for the determination of ascorbic acid and hydrogen peroxide was 0-3 mM and 0-2 mM, respectively, with an enzyme concentration of 25 U ascorbate oxidase/ml and 1000 U catalase/ml. The reproducibility was 5% for ascorbic acid (R.S.D. n=15) and 10% for hydrogen peroxide (R.S.D. n=18). The cost per measurement was 0.28 USD for ascorbic acid analysis and 0.0008 USD for hydrogen peroxide analysis. The degradation of ascorbic acid in cereal was followed in real-time, as was the stabilization of low pH on the degradation process.  相似文献   

4.
Summary A biosensor system for continuous on-line monitoring of hydrogen peroxide concentration was developed employing catalase and a poly(vinyl alcohol)/poly(tetra fluoro ethylene) bilayer membrane system, Catalase was entrapped between poly(vinyl alcohol) membrane layer and poly(tetra fluoro ethylene) membrane layer outside of the galvanic type DO probe. Since poly(vinyl alcohol) membrane has non-porous, hydrophilic characteristics, the difference in hydrogen peroxide concentration between inside and outside of the membrane was therefore approximately 100 times. The developed hydrogen peroxide sensor has a wide linear range of hydrogen peroxide sensing more than 140 mM and favourable dynamic response characteristics. The sensor showed also good operational stability, rapid response time, and long life time.  相似文献   

5.
An uric acid biosensor fabricated from a uricase-immobilized eggshell membrane and an oxygen electrode was presented. The detection schemes involve the enzymatic reactions of the uricase leading to the depletion of dissolved oxygen level upon exposure to uric acid solution. The decrease in oxygen level was monitored and related to the uric acid concentration. The scanning electron micrographs show the microstructure of the eggshell membrane within which the uricase is successfully immobilized. The effects of enzyme loading, pH, temperature, and phosphate buffer concentration on the response of the biosensor were investigated in detail. The uric acid biosensor has a linear response range of 4.0-640 microM with a detection limit of 2.0 microM (S/N=3). The response time was less than 100 s. The biosensor exhibited good repeatable response to a 0.10mM uric acid solution with a relative standard deviation of 3.1% (n=7). The reproducibility of fabrication of the biosensors using four different membranes was good with a R.S.D. of 3.2%. The biosensor showed extremely good stability with a shelf-life of at least 3 months. Some common potential interferents in samples such as glucose, urea, ascorbic acid, lactic acid, glycine, DL-alpha-alanine, DL-cysteine, KCl, NaCl, CaCl2, MgSO4, and NH4Cl showed no interferences on the response of the uric acid biosensor. The biosensor was successfully applied to determine the uric acid level in some human serum and urine samples, and the results agreed well with those obtained by a commercial colorimetric assay kit.  相似文献   

6.
A novel hydrogen peroxide biosensor was fabricated by using a DNA-Cu(II) complex as a novel electrocatalyst for the reduction of hydrogen peroxide (H2O2). A polyion complex (PIC) membrane composed of DNA and poly(allylamine) (PAA) functioned as a support matrix for immobilization of electrocatalytic element-copper ion. The circular dichroism (CD) spectrum of the DNA-Cu(II)/PAA membrane in wet state showed that the DNA exists in B-like form within the membrane. Electrochemical measurements of the DNA-Cu(II)/PAA membrane-modified glassy carbon (GC) electrode revealed that the copper ion embedded in the DNA/PAA layer exhibits good electrochemical behaviors, and the electrochemical rate constant between the immobilized copper ion and the GC electrode surface was estimated to be 26.4 s(-1). The resulting DNA-Cu(II)/PAA/GC electrode showed an excellent electrocatalytic activity for the H2O2 reduction. The sensitivity of the sensor for the determination of H2O2 was affected by the amount of each component, such as copper ion, DNA and PAA in the DNA-Cu(II)/PAA membrane. Effects of applied potential, pH, temperature, ionic strength and buffer concentrations upon the response currents of the sensor were also investigated for an optimum analytical performance. Even in the presence of dissolved oxygen, the sensor exhibited highly sensitive and rapid (response time, less than 5 s) response to H2O2. The steady-state cathodic current responses of the sensor obtained at -0.2 V versus Ag/AgCl in air-saturated 50 mM phosphate buffer (pH 5.0) increased linearly up to 135 microM with the detection limit of 50 nM. Interference by ascorbic acid and uric acid due to the reduction of Cu(II) was effectively cancelled by further modification of outermost layer of polyion complex film. In addition, the sensor exhibited good reproducibility and stability.  相似文献   

7.
A cobalt(II)hexacyanoferrate-based biosensor has been prepared simply by codeposition of an enzyme, together with the electrochemical formation of a cobalt (II)hexacyanoferrate compound electrochemically. The compound can be generated at a constant potential of -0.05 V (vs. Ag/AgCl). This compound possesses the catalytic property of reducing hydrogen peroxide to water at the operating potential of 0.0 V vs. Ag/AgCl. The mixed-valence compound-based biosensor possesses an unique interference-independent feature, which is important for biomedical application; this feature is attributed to the low overvoltage characteristic of cobalt (II)hexacyanoferrate. The electrochemical glucose biosensor responds to a series of glucose injections with linearity up to 5 mM (with correlation coefficient R = 0.9999) and the sensitivity of the linear portion is 733 nA/(cm2 x mM). The detection limit is 2 x 10(-6)M (S/N = 3). Both the potential-dependent electron transfer rate constant and the apparent Michaelis-Menten constant were studied in rotating disk experiments. The apparent Michaelis-Menten constant, Km' calculated from the slope of the "Lineweaver-Burke" type reciprocal plot is 28 mM. A fast-response characteristic is observed in the rotating disk experiment and the 95% response time is 14.5 sec. No response was observed from the addition of either 2 x 10(-4)M galactose, acetaminophen, ascorbic acid, uric acid, cysteine, tyrosine, dopamine, or 1,4-dihydroxyquinone in the absence and/or in the presence of 5 x 10(-4)M glucose.  相似文献   

8.
We report for the first time the development of a sensitive and selective glucose biosensor based on the self-assembling of multiwall carbon nanotubes (MWCNTs) dispersed in polyhistidine (Polyhis) and glucose oxidase (GOx) on glassy carbon electrodes (GCE). The supramolecular architecture was characterized by SEM, FT-IR and electrochemical techniques. The optimum multistructure was obtained with five (MWCNT-Polyhis/GOx) bilayers and one layer of Nafion as anti-interferent barrier. The sensitivity at 0.700V was (1.94±0.03) mAM(-1) (r=0.9991), with a linear range between 0.25 and 5.00mM, a detection limit of 2.2μM and a quantification limit of 6.7μM with minimum interference from lactose (1.5%), maltose (5.7%), galactose (1.2%), ascorbic acid (1.0%), and uric acid (3.3%). The biocatalytic layer demonstrated to be highly reproducible since the R.S.D. for 10 successive amperometric calibrations using the same surface was 3.6%. The sensitivity of the biosensor after 15 day storage at 4°C remained at 90% of its original value. The combination of the excellent dispersing properties and polycationic nature of polyhistidine, the stability of the MWCNT-Polyhis dispersion, the electrocatalytic properties of MWCNTs, the biocatalytic specificity of GOx, and the permselective properties of Nafion have allowed building up a sensitive, selective, robust, reproducible and stable glucose amperometric biosensor for the quantification of glucose in milk samples.  相似文献   

9.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a copper dispersed sol-gel derived ceramic-graphite composite. The copper in the biocomposite offers excellent electrocatalytic activity towards the reduction (at -0.2 V) as well as oxidation (at +0.45 V) of hydrogen peroxide liberated in the enzymatic reaction enabling sensitive and selective determination of glucose. A linear response to glucose in the concentration range between 2.7 x 10(-5) to 4.0 x 10(-3) M with a correlation coefficient of 0.9987 and 4.0 x 10(-5) to 5.6 x 10(-3) M with a correlation coefficient of 0.9989 were observed with the electrocatalytic reduction and oxidation, respectively. Ascorbic acid and uric acid did not interfere with the glucose measurement during catalytic reduction at -0.2 V, a Nafion membrane was used to eliminate these interferences during the electrocatalytic oxidation at +0.45 V. The combination of copper catalysis and the promising feature of sol-gel biocomposite favor the sensitive and selective determination of glucose with improved analytical capabilities.  相似文献   

10.
In this paper, a novel amperometric glucose biosensor was constructed by alternative self-assembly of positively charged poly(diallydimethylammonium chloride) (PDDA) and negatively charged glucose oxidase (GOx) onto a 3D Nafion network via electrostatic adsorption. The amount of Nafion in the electrode and the number of the (PDDA/GOx)n multilayers were optimized to develop a sensitive and selective glucose biosensor. Under optimal conditions, the glucose biosensor with (PDDA/GOx)5 multilayers exhibited remarkable electrocatalytic activity, capable of detecting glucose with enhanced sensitivity of 9.55 μA/mM cm2 and a commendably low detection limit of 20 μM (S/N = 3). A linear response range of 0.05–7 mM (a linear correlation coefficient of 0.9984, n = 20) was achieved. In addition, the glucose biosensor demonstrated superior selectivity towards glucose over some interferents, such as ascorbic acid (AA) and uric acid (UA), at an optimized detection potential of 0.6 V versus Ag/AgCl reference.  相似文献   

11.
Yin B  Yuan R  Chai Y  Chen S  Cao S  Xu Y  Fu P 《Biotechnology letters》2008,30(2):317-322
A glucose biosensor based on layer-by-layer (LBL) self-assembling of chitosan and glucose oxidase (GOD) on a Prussian blue film was developed. First, Prussian blue was deposited on a cleaned gold electrode then chitosan and GOD were assembled alternately to construct a multilayer film. The resulting amperometric glucose biosensor exhibited a fast response time (within 10 s) and a linear calibration range from 6 μM to 1.6 mM with a detection limit of 3.1 μM glucose (s/n = 3). With the low operating potential, the biosensor showed little interference to the possible interferents, including ascorbic acid, acetaminophen and uric acid, indicating an excellent selectivity.  相似文献   

12.
Electrospinning was used to prepare the nanofibrous membrane (NFM) of the composite comprising poly(vinylidene fluoride) and poly(aminophenylboronic acid) (PVdF/PAPBA-NFM). The PVdF/PAPBA-NFM displayed an excellent linear response to the detection of glucose for the concentration range of 1 to 15mM with a response time of less than 6s. Further experiments on amperometric sensing of glucose were performed in the presence of interferents such as uric acid, ascorbic acid, acetaminophen, fructose, mannose, etc. using PVdF/PAPBA-NFM. The interferents did not give significant overlapping current signal during the determination of glucose. Also, PVdF/PAPBA-NFM possesses better reproducibility toward glucose detection and storage stability.  相似文献   

13.
We have constructed and tested in vitro a potentially implantable, needle-type amperometric enzyme electrode which is suitable for continuous monitoring of glucose concentrations in diabetic patients. The major requirements of stability during operation and ease of manufacture have been met with a sensor design which involves a simple dip-coating procedure for applying to a platinum base electrode an inner membrane of glucose oxidase immobilised in polyhydroxyethyl methacrylate (pHEMA), and an outer membrane composed of a pHEMA/polyurethane mixture. Sensors were operated at 700 mV for detection of hydrogen peroxide. Calibration curves for the sensor were linear to at least 20 mM glucose and were unaffected by a reduction in PO2 from 20 to 5 kPa. During continuous operation in 5 mM buffered glucose solutions in vitro, sensors suffered no significant loss of response over periods of up to 60 h. Such electrodes are, therefore, useful for development as in vivo glucose sensors.  相似文献   

14.
A sensitive, selective and stable amperometric glucose biosensor employing novel PtPd bimetallic nanoparticles decorated on multi-walled carbon nanotubes (PtPd-MWCNTs) was investigated. PtPd-MWCNTs were prepared by a modified Watanabe method, and characterized by XRD and TEM. The biosensor was constructed by immobilizing the PtPd-MWCNTs catalysts in a Nafion film on a glassy carbon electrode. An inner Na?on film coating was used to eliminate common interferents such as uric acid, ascorbic acid and fructose. Finally, a highly porous surface with an orderly three-dimensional network enzyme layer (CS-GA-GOx) was fabricated by electrodeposition. The resulting biosensor exhibited a good response to glucose with a wide linear range (0.062-14.07 mM) and a low detection limit 0.031 mM. The biosensor also showed a short response time (within 5 s), and a high sensitivity (112 μA mM(-1)cm(-2)). The Michaelis-Menten constant (K(m)) was determined as 3.3 mM. In addition, the biosensor exhibited high reproducibility, good storage stability and satisfactory anti-interference ability. The applicability of the biosensor to actual serum sample analysis was also evaluated.  相似文献   

15.
A glucose amperometric biosensor based on the immobilization of glucose oxidase (GOx) in microparticles prepared by polymerization of the ionic liquid 1-vinyl-3-ethyl-imidazolium bromide (ViEtIm+Br) using the concentrated emulsion polymerization method has been developed. The polymerization of the emulsion dispersed phase, in which the enzyme was dissolved together with the ionic liquid monomer, provides poly(ViEtIm+Br) microparticles with entrapped GOx. An anion-exchange reaction was carried out for synthesizing new microparticles of poly(ViEtIm+(CF3SO2)2N) and poly(ViEtIm+BF4). The enzyme immobilization method was optimized for biosensor applications and the following optimal values were determined: pH 4.0 for the synthesis medium, 1.23 M monomer concentration and 3.2% (w/w) cross-linking content. The performance of the biosensor as a function of some analytical parameters such as pH and temperature of the measuring medium, and enzymatic load of the microparticles was also investigated. The effect of the substances which are present in serum samples such as uric and ascorbic acid was eliminated by using a thin Nafion layer covering the electrode surface. The biosensor thus prepared can be employed in aqueous and in non-aqueous media with satisfactory results for glucose determination in human serum samples. The useful lifetime of this biosensor was 150 days.  相似文献   

16.
A split-stream flow-injection analysis system is described for simultaneous determination of glucose and L-glutamine in serum-free hybridoma bioprocesses media. Amperometric measurement of glucose is based on anodic oxidation of hydrogen peroxide produced by immobilized glucose oxidase within a triple layer membrane of an integrated flow-through glucose-selective biosensor. Determination of L-glutamine is based on quantitating ammonium ions produced in a flow-through enzymes reactor containing immobilized glutaminase enzyme, and subsequent downstream potentiometric detection of these ions by a nonacting-based ion-selective polymer membrane electrode. Endogenous potassium and ammonium ion interference in the L-glutamine determination are eliminated by using a novel in-line tubular cation-exchange membrane unit to exchange these interferent species for cations undetectable by the membrane electrode. The first generation split-steam flow-injections system can assay 12 samples/h using direct injections of 50 muL of media samples, with linear responses to glucose in the range of 0.03 to 30mM, and log-linear response to L-glutamine from 0.1 to 10 mM. (c) 1993 Wiley & Sons, Inc.  相似文献   

17.
An enzyme-free amperometric method was established for glucose detection using a nanoporous gold film (NPGF) electrode prepared by a rapid one-step anodic potential step method within 5 min. The prepared NPGF had an extremely high roughness and was characterized by scanning electron microscopy (SEM) and cyclic voltammetry. Electrochemical responses of the as-prepared NPGF to glucose in 0.1M phosphate buffer solution (PBS, pH 7.4) with or without Cl(-) were discussed. In amperometric studies carried out at -0.15 V in the absence of Cl(-), the NPGF electrode exhibited a high sensitivity of 232 μA mM(-1)cm(-2) and gave a linear range from 1mM up to 14 mM with a detection limit of 53.2 μM (with a signal-to-noise ratio of 3). In addition, the oxidation of ascorbic acid (AA) and uric acid (UA) can be completely eliminated at such a low applied potential. On the other hand, the quantification of glucose in 0.1M PBS (pH 7.4) containing 0.1M NaCl offered an extended linear range from 10 μM to 11 mM with a sensitivity of 66.0 μA mM(-1)cm(-2) and a low detection limit of 8.7 μM (signal-to-noise ratio of 3) at a detection potential of 0.2V.  相似文献   

18.
A novel third-generation biosensor for hydrogen peroxide (H2O2) was developed by self-assembling gold nanoparticles to hollow porous thiol-functionalized poly(divinylbenzene-co-acrylic acid) (DVB-co-AA) nanospheres. At first, a cleaned gold electrode was immersed in hollow porous thiol-functionalized poly(DVB-co-AA) nanosphere latex to assemble the nanospheres, then gold nanoparticles were chemisorbed onto the thiol groups of the nanospheres. Finally, horseradish peroxidase (HRP) was immobilized on the surface of the gold nanoparticles. The immobilized horseradish peroxidase exhibited direct electrochemical behavior toward the reduction of hydrogen peroxide. The resulting biosensor showed a wide linear range of 1.0 microM-8.0mM and a detection limit of 0.5 microM estimated at a signal-to-noise ratio of 3. Moreover, the studied biosensor exhibited high sensitivity, good reproducibility, and long-term stability.  相似文献   

19.
Present study concerns modulating the electron transfer properties of gold nanoparticles through amino acid induced coupling among them. In addition to conductivity, the amino functionalization of the nanoparticles results in enhanced activity and operational stability of the biosensor fabricated using the same. Nanoparticles synthesized using amino acid as reducing agent (average diameter-20 nm), incorporate the natural coupling property of amino acids and are seen to align in a chain-like arrangement. The coupling of the individual nanoparticles to form chain like structure was confirmed by both absorption spectroscopy as well as transmission electron microscopy. The glucose biosensor developed by adsorption of glucose oxidase (GOx) enzyme onto these coupled gold nanoparticles showed enhanced efficiency as compared to the one with glucose oxidase immobilized onto gold nanoparticles synthesized using the conventional method (trisodium citrate as reducing agent). The fabricated biosensor demonstrated a wide linear concentration range from 1 μM-5mM and a high sensitivity of 47.2 μA mM(-1) cm(-2). Also, an enhanced selectivity to glucose was observed with negligible interference in the physiological range, from easily oxidizable biospecies, e.g. uric acid and ascorbic acid. Furthermore, the electrochemical biosensor has excellent long term stability- retaining greater than 85% of the biosensor activity up to 60 days.  相似文献   

20.
An absorption-based surface plasmon resonance (SPR(Abs)) biosensor probe has been developed for simple and reproducible measurements of hydrogen peroxide using a modified Trinder's reagent (a chromogenic reagent). The reagent enabled the determination of the hydrogen peroxide concentration by the development of deep color dyes (lambda(max)=630nm) through the oxidative coupling reaction with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethylaniline sodium salt monohydrate (MAOS; C(13)H(20)NNaO(4)S.H(2)O) and 4-aminoantipyrine (4-AA) in the presence of hydrogen peroxide and horseradish peroxidase (HRP). In the present study, urea as an adduct of hydrogen peroxide for color development could be omitted from the measurement solution. The measurement solution containing 5mM hydrogen peroxide was deeply colored at a high absorbance value calculated as 46.7cm(-1) and was directly applied to the SPR(Abs) biosensing without dilution. The measurement was simply performed by dropping the measurement solution onto the surface of the SPR sensor probe, and the SPR(Abs) biosensor response to hydrogen peroxide was obtained as a reflectivity change in the SPR spectrum. After investigation of the pH profiles in the SPR(Abs) biosensor probe, a linear calibration curve was obtained between 1.0 and 50mM hydrogen peroxide (r=0.991, six points, average of relative standard deviation; 0.152%, n=3) with a detection limit of 0.5mM. To examine the applicability of this SPR(Abs) biosensor probe, 20mM glucose detection using glucose oxidase was also confirmed without influence of the refractive index in the measurement solution. Thus, the SPR(Abs) biosensor probe employing the modified Trinder's reagent demonstrated applicability to other analyte biosensing tools.  相似文献   