首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 18 毫秒
1.
A simple and sensitive flow injection chemiluminescence (FI‐CL) method was developed for the determination of naphazoline hydrochloride (NPZ). The method is based on the enhancing effect of NPZ on the weak CL signal from the reaction of KIO4 with H2O2. Experimental parameters that affected the CL signal, including the pH of the KIO4 solution, concentrations of KIO4, H2O2 and disodium‐EDTA and flow rate were optimized. Under the optimum conditions, the increment of CL intensity was linearly proportional to the concentration of NPZ in the range 5.0 × 10?6 to 70 × 10?6 mol/L. The detection limit was 1.0 × 10?6 mol/L and the relative standard deviation for 50 × 10?6 mol/L NPZ solution was 2.8% (n = 11). In addition, a high throughput of 120 samples/h was achieved. The utility of this method was demonstrated by determining NPZ in pharmaceuticals. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive and simple flow‐injection chemiluminescence (FI‐CL) method, which was based on the CL intensity generated from the redoxreaction of potassium permanganate (KMnO4)–formaldehyde in vitriol (H2SO4) medium, has been developed, validated and applied for the determination of naphazoline hydrochloride and oxymetazoline hydrochloride. Besides oxidants and sensitizers, the effect of the concentration of H2SO4, KMnO4 and formaldehyde was investigated. Under the optimum conditions, the linear range was 1.0 × 10?2–7.0 mg/L for naphazoline hydrochloride and 5.0 × 10?2–10.0 mg/L for oxymetazoline hydrochloride. During seven repeated inter‐day and intra‐day precision tests of 0.1, 1.0 and 10.0 mg/L samples, the relative standard deviations all corresponded to reference values. The detection limit was 8.69 × 10?3 mg/L for naphazoline hydrochloride and 3.47 × 10?2 mg/L for oxymetazoline hydrochloride (signal‐to‐noise ratio ≤3). This method has been successfully implemented for the determination of naphazoline hydrochloride and oxymetazoline hydrochloride in pharmaceuticals. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A simple and sensitive flow‐injection chemiluminescence (CL) method has been developed for the determination of gentamicin sulfate. The method is based on the inhibitory effect of gentamicin on the CL emission accompanying oxidation of luminol by H2O2 in an alkaline medium in the presence of Cu(II) as a catalyst. Inhibition was caused by the formation of a strong complex between analyte and the catalyst. Experimental variables, including the concentrations of luminol (µmol/L), H2O2 (mol/L), Cu(II) (mol/L) and NaOH (mol/L), were optimized using a central composite design. Under optimum conditions, the plot of CL intensity versus gentamicin concentration was found to have two linear ranges. One range was at low concentrations from 1.0 to 10.0 mg/L and the other was from 10.0 to 30.0 mg/L. Precision was calculated by analyzing samples containing 5.0 mg/L gentamicin (n = 11) and the relative standard deviation (RSD) was 1.7%. Also, a high injection throughput of 120 samples/h was achieved. This method was successfully applied to the determination of gentamicin sulfate in pharmaceutical formulations and water samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
Flow injection (FI) methods are reported to determine retinol and α‐tocopherol based on its enhancement affect of lucigenin chemiluminescence (CL) in alkaline medium. Surfactants including Brij‐35, Triton X‐100, cetyltrimethyl ammonium bromide (CTAB) and sodium dodecyl sulfate have been reported for the first time to enhance lucigenin CL intensity in the presence of retinol and α‐tocopherol. With Brij‐35, the CL intensity was enhanced by 67% for retinol and 58% for α‐tocopherol. CTAB was found to enhance the CL intensity by 16% for retinol whereas for α‐tocopherol, the CL intensity was quenched up to 95%. Retinol could be determined specifically in the presence of α‐tocopherol using CTAB. The calibration graphs were found to be linear up to 1.43 mg/L (R2 = 0.9985, n = 8) with a detection limit (3s) of 1.43 × 10?3 mg/L for retinol and 2.15 mg/L (R2 = 0.9989; n = 8) with a detection limit (3s) of 4.31 × 10?4 mg/L for α‐tocopherol. An injection throughput of 120/h, and relative standard deviations of 0.9–2.8% (n = 4) were achieved in the concentration range studied. The influence of common ions, excipients in pharmaceutical formulations and related organic compounds on the determination of retinol and α‐tocopherol individually was studied. The proposed methods were applied to determine retinol and α‐tocopherol in pharmaceutical formulations and human blood serum. The results did not differ significantly from the CL method and HPLC reference method at 95% confidence level. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A flow injection (FI) method is reported for the determination of l‐ cysteine, based on its enhancement on chemiluminescence (CL) emission of luminol oxidized by sodium persulphate in alkaline solution. The calibration graph was linear over the range 1.0 × 10–9–5.0 × 10–7 mol/L (r2 = 0.9992), with relative standard deviations (RSDs) in the range 1.1–2.3% (n = 4). The limit of detection (3σ blank) was 5.0 × 10–10 mol/L with a sample throughput of 120/h. The method was applied to pharmaceuticals and the results obtained were in reasonable agreement with the amount labelled. The proposed method was also applied to cysteine in synthetic amino acid mixtures. Calibration graphs of N‐acetylcysteine and glutathione over the range 1.0–50 × 10–8 and 0.5–7.5 × 10–7 mol/L were also established (r2 = 0.998 and 0.9986) with RSDs in the range 1.0–2.0% (n = 4), and the limits of detection (3σ blank) were 5.0 × 10–9 and 1.0 × 10–8 mol/L, respectively. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

6.
A simple and sensitive spectrofluorimetric method was developed for the determination of Ribavirin in pharmaceutical formulations. The proposed method was based on the fluorescence spectral behaviour of Ribavirin in a sodium dodecyl sulfate (SDS) micellar system. In an aqueous acetate buffer solution of pH 4.0, the fluorescence intensity of Ribavirin was significantly enhanced by about 217% in the presence of SDS. Fluorescence intensity was measured at 396 nm after excitation at 270 nm for Ribavirin. The fluorescence‐concentration plot was rectilinear over the range of 0.01‐3.0 µg/mL for Ribavirin with a lower detection limit of 5.02 x 10‐3 µg/mL. The method was successfully applied to the analysis of the drug in its commercial capsules. Results were in good agreement with those obtained with the official method. The application of the proposed method was extended to stability studies of Ribavirin after exposure to different forced degradation conditions such as acidic, alkaline, photo and oxidative conditions according to ICH guidelines. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
A highly sensitive and simple spectrofluorimetric method was developed for the determination of loratadine (LRT) and desloratadine (DSL) in their pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behaviour of LRT and DSL in a sodium dodecyl sulphate (SDS) micellar system. In aqueous solution of acetate buffer of pH 4.5, the fluorescence intensities of both LRT and DSL were greatly enhanced (240%) in the presence of SDS. The fluorescence intensity was measured at 438 nm after excitation at 290 nm for both drugs. The fluorescence–concentration plots were rectilinear over the range 0.05–2.0 µg/mL for both LRT and DSL, with lower detection limits of 5.13 × 10?3 and 6.35 × 10?3 µg/mL for LRT and DSL, respectively. The method was successfully applied to the analysis of the two drugs in their commercial tablets, capsules and syrups, and the results were in good agreement with those obtained with the official or comparison methods. The proposed method is specific for the determination of LRT in the presence of other co‐formulated drugs, such as pseudoephedrine. The application of the proposed method was extended to stability studies of LRT and DSL after exposure to different forced degradation conditions, such as acidic, alkaline and oxidative conditions, according to ICH guidelines. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
Two simple, rapid and sensitive methods, namely, fourth‐derivative synchronous spectrofluorimetry (method I) and HPLC with fluorescence detection (method II) were developed for the simultaneous analysis of a binary mixture of itopride HCl (ITP) and domperidone (DOM) without prior separation. The first method was based on measuring the fourth derivative of the synchronous fluorescence spectra of the two drugs at Δλ = 40 nm in methanol. The different experimental parameters affecting the synchronous fluorescence of the studied drugs were carefully optimized. Chromatographic separation was performed in < 6.0 min using a RP C18 column (250 mm × 4.6 mm i.d., 5 µm particle size) with fluorescence detection at 344 nm after excitation at 285 nm. A mobile phase composed of a mixture of 0.02 M phosphate buffer with acetonitrile in a ratio of 55 : 45, pH 4.5, was used at a flow rate of 1 mL/min. Linearity ranges were found to be 0.1–2 µg/mL for ITP in both methods, whereas those for DOM were found to be 0.08–2 and 0.05–1.5 µg/mL in methods I and II, respectively. The proposed methods were successfully applied for the determination of the studied drugs in synthetic mixtures and laboratory‐prepared tablets. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
A flow‐injection (FI) method is reported for the determination of Mn(II), maneb and mancozeb fungicides based on the catalytic effect of Mn(II) on the oxidation of lucigenin and dissolved oxygen in a basic solution. The Tween‐20 surfactant has been reported for first time to enhance lucigenin chemiluminescence (CL) intensity in the presence of Mn(II) (53%) and maneb and mancozeb (89%). The calibration graphs were linear in the concentration range of 0.001–1.5 mg L–1 (R2 = 0.9982 (n = 11) with a limit of detection (S/N = 3) of 0.1 µg L–1 for Mn(II) and 0.01–3.0 mg L–1 [R2 = 0.9989 and R2 = 0.9992 (n = 6)] with a limit of detection (S/N =3) of 1.0 µg L–1 for maneb and mancozeb respectively. Injection throughputs of 90 and 120 h–1 for Mn(II) and maneb and mancozeb respectively, and relative standard deviations of 1.0–3.4% were obtained in the concentration range studied. The experimental variables, e.g., reagents concentrations, flow rates, sample volume, and photomultiplier tube voltage, were optimized and potential interferences were investigated. The analysis of Mn(II) in river water reference materials (SLRS‐4 and SLRS‐5) showed good agreement with the certified values incorporating an on‐line 8‐hydroxyquinoline chelating column in the manifold for removing interfering metal ions. Recoveries for maneb and mancozeb were in the range of 92 ± 5 to 104 ± 3% and 91 ± 2 to 100 ± 4% (n = 3) respectively. The effect of 30 other pesticides (fungicides, herbicides and insecticides) was also examined in the lucigenin–Tween‐20 CL system. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
The chemiluminescence (CL) behaviour of the luminol–potassium periodate system enhanced by CdTe quantum dots capped with thioglycolic acid (TGA–CdTe QDs) was studied using kinetic experiments, CL spectra, UV–vis absorption spectra and fluorescence spectra. The production of oxygen‐containing reactant intermediates (O2?? and OH?) in the present CL system was verified by CL. The possible CL mechanism was discussed in detail. Furthermore, theophylline (THP) was determined based on its enhancement of the CL intensity of the CdTe QDs–luminol–potassium periodate system coupled with a flow‐injection technique. Under these optimized conditions, the linear range was found to be from 1.0 × 10?8 to 1.0 × 10?5 g/mL with a detection limit of 2.8 × 10?9 g/mL (3σ). The recoveries for the determination of THP in tablets were from 98.2 to 99.6%.  相似文献   

11.
Taking advantage of the compelling properties of d ‐penicillamine (d ‐PA) combined with copper, a method for the sensitive and selective determination of d ‐PA was established using copper nanocluster (Cu NC)‐based fluorescence enhancement. d ‐PA molecules containing a thiol compound showed a strong tendency to combine with the surface of Cu NCs, causing the re‐dispersion of nanoclusters and therefore fluorescence intensity was enhanced. Fluorescence enhancement efficiency of Cu NCs induced by d ‐PA was linear, with the d ‐PA concentration varying from 0.6–30 μg ml?1 (R2 = 0.9952) and with a detection limit of 0.54 μg ml?1. d ‐PA content in human urine samples was detected with recoveries of 104.8–112.99%. Fluorescence‐enhanced determination of d ‐PA using Cu NCs was established for the first time and this rapid, easy and sensitive method should attract much attention for this application.  相似文献   

12.
In this paper, a simple and highly sensitive spectrofluorimetric method was developed and validated for the determination of entacapone (ETC). The proposed method is based on forming a highly fluorescent product through the reduction of ETC with Zn/HCl. The produced fluorophore exhibits strong fluorescence at λem 345 nm after excitation at λex 240 nm. The use of fluorescence enhancers such as Tween‐80 and carboxy methyl cellulose (CMC) greatly enhanced the fluorescence of the produced fluorophore by 150% and 200%, respectively. Calibration curves showed good linear regression (r2 > 0.9998) within test ranges of 0.05–2.0 and 0.02–1.80 μg mL?1 with lower detection limits of 1.27 × 10?2 and 4.8 × 10?3 μg mL?1 and lower quantification limits of 4.21 × 10?2 and 1.61 × 10?2 μg mL?1 upon using Tween‐80 and or CMC, respectively. The method was successfully applied to the analysis of ETC in its pharmaceutical formulations (either alone or in presence of other co‐formulated drugs). The results were in good agreement with those obtained using the official method. The methods were further extended to determine the drug in human plasma samples, and to study the pharmacokinetics of ETC. The paper is the first report on the spectrofluorimetric determination of entacapone.  相似文献   

13.
A novel, quick, simple and highly sensitive spectrofluorimetric method was developed and validated for the determination of sitagliptin (SG) in its pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behavior of sitagliptin in an SDS micellar system. In an aqueous solution of phosphate buffer pH 4.0, the fluorescence intensity of SG in the presence of SDS was greatly enhanced, by 200%, i.e. twofold enhancement. The fluorescence intensity of SG was measured at 300 nm after excitation at 270 nm. The method showed good linearity in the range 0.03–10.0 µg/mL with a good correlation coefficient (r = 0.9998). The limits of detection and quantitation values were 5.31 and 16.1 ng/mL, respectively. The proposed method was successfully applied to the analysis of SG in its single and co‐formulated commercial tablets; the results were in good agreement with those obtained using a reference method. Application of the proposed method was extended to stability studies of SG after exposure to different forced degradation conditions according to the ICH guidelines, such as acidic, alkaline, thermal, photo‐ and oxidative stress. The chemical structure of certain potential degradation products (DPs) were investigated using LC‐MS. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A two‐channel flow‐injection (FI) method is reported for the determination of iodide and iodine by its enhancement effect on the Ru(bpy)33+–NADH chemiluminescence (CL) system. The limit of detection (3 s of blank) was 1.0 × 10–9 mol/L iodide/iodine, with a sample throughput of 60/h. The calibration graphs over the range 1.0–50 × 10–8 mol/L gave correlation coefficients of 0.9994 and 0.999 (n = 5) with relative standard deviations (RSD; n = 4) of 1.0–2.5%, respectively. The effects of interfering cations, anions and some organic compounds were also studied. The method was applied to iodized salts and pharmaceutical samples and the results obtained were in good agreement with the value quoted. The CL method developed was compared with spectrophotometric method. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of lacidipine (LCP) in tablets. The proposed method is based on the investigation of the fluorescence spectral behavior of LCP in both sodium dodecyl sulphate (SDS) and the tween‐80 micellar system. In aqueous solutions of acetate buffer (pH 4.5), the fluorescence intensities of LCP were greatly enhanced (ca. 2.4 and 4.3 folds) in the presence of either SDS or tween‐80, respectively. The fluorescence intensity was measured at 444 nm after excitation at 277 nm using either SDS or tween‐80 as a surfactant. The fluorescence–concentration plots were rectilinear over the ranges of 50.0–500.0 ng/ml and 5.0–200.0 ng/ml with lower detection limits of 5.11 and 2.06 ng/ml and lower quantification limits of 17 and 6.87 ng/ml using SDS and tween‐80, respectively. The method was successfully applied to the analysis of LCP in commercial tablets and the results were in good agreement with those obtained with the comparison method. Furthermore, content uniformity testing of pharmaceutical tablets was also conducted. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A rapid and sensitive flow‐injection chemiluminescence (FI–CL) method is described for the determination of diazepam based on its reaction with N‐bromosuccinimide (NBS) in alkaline medium in the presence of dichlorofluorescein (DCF) as an effective energy‐transfer agent. Under optimum conditions, the proposed method allowed the measurement of diazepam over the range of 2.0 × 10?6 to 2.0 × 10?4 mol/L with a detection limit of 5.0 × 10?7 mol/L. The relative standard deviation for 11 parallel measurements of 2.0 × 10?5 mol/L diazepam was 2.1%. The method was applied satisfactorily for the determination of diazepam in pharmaceutical preparations, and the results agree well with those obtained by spectrophotometry. The use of the proposed system for the determination of diazepam in urine and plasma samples was also tested. The possible mechanism of the chemiluminescence reaction is discussed briefly. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
By taking advantage of microflow injection chemiluminescence analysis, we developed a distinctive microfluidic bioassay method based on G‐Quadruplex DNAzyme‐enhanced chemiluminescence for the determination of K+ in human serum. AGRO100, the G‐rich oligonucleotide with high hemin binding affinity was primarily selected as a K+ recognition element. In the presence of K+, AGRO100 folded into G‐quadruplex and bound hemin to form DNAzyme, which catalyzed the oxidation of luminol by H2O2 to produce chemiluminescence. The intensity of chemiluminescence increased with the K+ concentration. In the study, the DNAzyme showed both long‐term stability and high catalytic activity; other common cations at their physiological concentration did not cause notable interference. With only 6.7 × 10?13 mol of AGRO100 consumption per sample, a linear response of K+ ranged from 1 to 300 µmol/L, the concentration detection limit 0.69 µmol/L (S/N = 3) and the absolute detection limit 1.38 × 10?12 mol were obtained. The precision of 10 replicate measurements of 60 µmol/L K+ was found to be 1.72% (relative standard deviation). The accuracy of the method was demonstrated by analyzing real human serum samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A remarkable method for the highly sensitive detection of phenylalanine and tryptophan based on a chemiluminescence (CL) assay was reported. It was found that fluorescent copper nanoclusters capped with cysteine (Cys‐CuNCs) strongly enhance the weak CL signal resulting from the reaction between luminol and H2O2. Of the amino acids tested, phenylalanine and tryptophan could enhance the above CL system sensitively. Under optimum conditions, this method was satisfactorily described by a linear calibration curve over a range of 1.0 × 10?6 to 2.7 × 10?5 M for phenylalanine and 1.0 × 10?7 to 3.0 × 10?5 M for tryptophan, respectively. The effect of various parameters such as Cys‐CuNC concentration, H2O2 concentration and pH on the intensity of the CL system were also studied. The main experimental advantage of the proposed method was its selectivity for two amino acids compared with others. To evaluate the applicability of the method to the analysis of a real biological sample it was used to determine tryptophan and phenylalanine in human serum and remarkable results were obtained.  相似文献   

19.
We report for the first time that the sensitivity of the luminol–hypochlorite chemiluminescence (CL) reaction was enhanced approximately 10 times by the addition of phloxine B. The maximum wavelength of CL emission shifted from 431 to 595 nm in the absence and presence, respectively, of phloxine B, suggesting that an efficient chemiluminescence resonance energy transfer occurred between a luminol donor and a phloxine B acceptor in the luminol–hypochlorite–phloxine B system. Based on this observation, a simple, rapid and sensitive microflow injection CL method, using a microchip with spiral channel configurations, was developed for the determination of hypochlorite. Under optimized conditions, a linear calibration curve (R2 = 0.9944) over the range 0.1–10.0 µmol/L was obtained, with a detection limit of 0.025 µmol/L (S:N = 3). The relative standard deviation (RSD) was found to be 4.2% (n = 10) for 2.5 µmol/L hypochlorite. The sample consumption was only 2 μL, with a sample throughput of 90/h. The method has been used for determining trace amounts of hypochlorite in water samples with satisfactory results. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
Chemiluminescence (CL) of the rhodamine 6‐G‐diperiodatonickelate (IV) (Rh6‐G‐Ni(IV) complex) in the presence of Brij‐35 was examined in an alkaline medium and implemented using flow‐injection analysis to analyze Mn(II) in natural waters. Brij‐35 was identified as the surfactant of choice that enhanced CL intensity by about 62% of the reaction. The calibration curves were linear in the range 1.7 × 10?3 – 0.2 (0.9990, n = 7) and 8.0 × 10?4 – 0.1 μg ml?1 (0.9990, n = 7) with limits of detection (LODs) (S:N = 3) of 5.0 × 10?4 and 2.4 × 10?4 μg ml?1 without and with using an in‐line 8‐hydroxyquinoline (8‐HQ) resin mini‐column, respectively. The sample throughput and relative standard deviation were 200 h?1 and 1.7–2.2% in the range studied respectively. Mn(II) concentrations in certified reference materials and natural water samples was successfully determined. A brief discussion about the possible CL reaction mechanism is also given. In addition, analysis of V(III), Cr(III) and Fe(II) was also performed without and with using an in‐line 8–HQ column and selective elution of each metal ion was achieved by adjusting the pH of the sample carrier stream with aqueous HCl solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号