首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Four commonly used techniques for preparation of 14C-labeled algal samples on membranes for liquid scintillation counting were compared and a simple technique for apparent net assimilation measurement from aqueous samples was introduced. All four techniques yielded similar radioactivities from the test cultures and are thus suitable for measurements of 14C algal samples. The possibly carcinogenic solvent dioxane was not necessary with PCS scintillation cocktail for dissolving radioactivity from algae on filters.  相似文献   

2.
Several variations in the scintillation mixture and the filter paper arrangements for double-vial radiorespirometry were compared. Improved efficiencies (44%) and shorter response times were found by adding wetting agents and methanolic NaOH to the scintillation mixture in the filter paper. The scintillation chemicals used did not contain dioxane and were found to be nontoxic to the test microbiota in this system. Covering the inner reaction vial with aluminum foil minimized the reduction in counting efficiency when testing colored or dense environmental samples. Mineralization rates were determined with 14C-labeled glucose, acetate, and glutamate and [14C]cellulose- and [14C]lignin-labeled lignocellulose for composting cow manure, forest soil, and arctic lake sediment microbiota. This improved method can be used in a variety of procedures involving the measurement of microbial mineralizations of organic compounds. Since no liquid scintillation cocktail is used for counting, the radioactive wastes are aqueous or can be incinerated, making disposal easy.  相似文献   

3.
A liquid scintillation counting method for simultaneous determination of three radioactive nuclides (3H, 14C, and 22Na) of biological interest was studied. By comparing the beta spectra of the three nuclides, their counting energy ranges, A, B, and C, were determined. 22NA was set high enough to avoid any spillover counts from lower-energy nuclides. Region A for 3H was set to maximize the counting efficiency. A good correlation between the counting efficiency for 22Na in region C and the counting efficiency of other nuclides in all regions was obtained. Prior to 3H and 14C dpm calculations, the 22Na counts spilled down in regions A and B were subtracted from the total counts in regions A and B. A simple linear equation was then used to compute 3H and 14C dpm. Findings show that the method presented is adaptable for highly quenched samples up to quenching indices of tSIE = 100. The method is useful for studying the biological transport coupled to Na+.  相似文献   

4.
Radiometric Method for the Detection of Coliform Organisms in Water   总被引:7,自引:7,他引:0       下载免费PDF全文
A new radiometric method for the detection of coliform bacteria in water has been described. The method is based on the release of 14CO2 from [14C]lactose by bacteria suspended in growth medium and incubated at 37 C. The evolved 14CO2 is trapped by hyamine hydroxide and counted in a liquid scintillation spectrometer. The method permits the detection of 1 to 10 organisms within 6 h of incubation. Coliform bacteria suspended in water for several days recover from starvation and may be quantitated by the proposed method. Bacteria from water samples may also be concentrated by filtration through membrane filters and detected by the radiometric assay.  相似文献   

5.
A quantitative polyacrylamide gel electrophoresis (PAGE) analysis using a multichannel radioactivity counter was designed for the evaluation of33P-labeled antisense oligonucleotide associated with polymeric drug carrier (nanoparticles). The proposed analytical method was first validated. The criteria of specificity, linearity, reliability, detection and quantification limits, and resolution power were determined. Results were compared to those obtained using liquid scintillation counting of crude samples or after solubilization of gel slices. The proposed method gave a better linearity and reliability than liquid scintillation counting of solubilized gel slices. In comparison with the liquid scintillation counting of crude samples, the method presented the advantage of being able to directly separate oligonucleotides differing by only one nucleotide in length. This method was applied for the separation of free oligonucleotides and oligonucleotides bound onto nanoparticles, allowing quantification of the amount of free and bound oligonucleotides without any further separation steps. Thus, because it is easy and rapid, the quantitative PAGE analysis using a multichannel radioactivity counter offers interesting possibilities for the characterization of oligonucleotide nanoparticles.  相似文献   

6.
A rapid procedure is described for the liquid scintillation counting of 14C-labeled hemin isolated after incubation of bone marrow with radioactively labeled glycine-2-14C. The method has been applied for studies on the biosynthesis of heme in bone marrow of several animal species.  相似文献   

7.
A new and sensitive method to measure UDP-glucuronic acid extracted from as little as 25 mg wet weight tissue has been developed. This procedure employs high-pressure liquid chromatography and liquid scintillation spectrophotometry to measure p-[14C]nitrophenylglucuronide generated enzymatically from p-[14C]nitrophenol and UDP-glucuronic acid. The reaction was catalyzed by UDP-glucuronyltransferase obtained from rat liver microsomes. The tissue levels of UDP-glucuronic acid assayed were 2 to 20 μmol/100 g wet wt, which are well below the levels detectable by the widely used spectrophotometric method.  相似文献   

8.
The present work describes an original method to follow rate of 14CO2 and total CO2 production from rhizosphere respiration after plant shoots had been pulse-labelled with 14CO2. We used a radioactivity detector equipped with a plastic cell for flow detection of beta radiation by solid scintillation counting. The radioactivity detector was coupled with an infrared gas analyser. The flow detection of 14CO2 was compared to trapping of 14CO2 in NaOH and counting by liquid scintillation. First, we demonstrated that NaOH (1 M) trapped 95% of the CO2 of a gaseous sample. Then, we determined that the counting efficiency of the radioactivity flow cell was 41% of the activity of gaseous samples as determined by trapping in NaOH (1 M) and by counting by static liquid scintillation. The sensitivity of the 14CO2- flow detection was 0.08 Bq mL−1 air and the precision was 2.9% of the activity measured compared to 0.9% for NaOH trapping method. We presented two applications which illustrate the relevance of 14CO2-flow detection to investigations using 14C to trace photoassimilates within the plant-soil system. First, we examined the kinetics of 14CO2 production when concentrated acid is added to NaH14CO3. This method is the most commonly used to label photoassimilates with 14C. Then, we monitored 14CO2 activity in rhizosphere respiration of 5-week old maize cultivated in soil and whose shoots had been pulse-labelled with 14CO2. We conclude that alkali traps should be used for a cumulative determination of 14CO2 because they are cheap and accurate. On the other hand, we demonstrated that the flow detection of 14CO2 had a finer temporal resolution and was consequently a relevant tool to study C dynamics in the rhizosphere at a short time scale. This revised version was published online in June 2006 with corrections to the Cover Date.  相似文献   

9.
A method for obtaining the true activity and counting efficiency of a 14C sample partially or completely adsorbed on the walls of a counting vial by liquid scintillation counting is presented.  相似文献   

10.
Absorption and excretion of a new tablet disintegrating agent, a crosslinked β-cyclodextrin polymer was investigated following per os administration in the rat. The polymer, which is insoluble but swells in water, was prepared from β-cyclodextrin by reacting with [2-14C]epichlorohydrin in an alkaline medium. Radioactivity of blood, urine, faeces, exhaled carbon dioxide and the gastrointestinal tract was determined by a liquid scintillation method. No radioactivity could be detected in the blood up to 24 h after the administration of the polymer. Radioactivity of urine and exhaled carbon dioxide together did not exceed 0·11% of the total administered radioactivity, 98% of which was found in the large intestine and the faeces. Therefore, it is assumed that β-cyclodextrin polymer could not be absorbed from the gastrointestinal tract.  相似文献   

11.
A new, simple, and accurate method for the sequential determination of the specific radioactivity of [1-14C]glutamic acid and [1-14C]glutamine is described. Using this method, radioactivity in H14CO3?, in [14C]glutamic acid, and in [14C]-glutamine can be readily determined on a single sample of blood plasma. Radioactivity is released as 14CO2 in a stepwise fashion, trapped in the center wells, and counted in a liquid scintillation counter. The applicability of the method is discussed.  相似文献   

12.
Scintillation flow cells provide a convenient means of monitoring column effluents for radioactively labeled compounds. The use of flow cells to monitor effluents containing 3H, 14C, and other β-emitting isotopes is well established (1) and such cells are readily available as accessories for use with liquid scintillation counters. β-Flow cells have occasionally been used to monitor γ emitters [e.g., Martin et al. (2)] but the counting efficiency is extremely low even for weak γ emitters such as 75Se, due to the limited mass of scintillant available to absorb the radiation.Spencer et al. (3) described a simple γ flow cell consisting of a coiled polyethylene tube inserted in to the well crystal of a γ counter, but no information on counting efficiency was given. Although spiral plastic γ cells have been manufactured commercially (e.g., Nuclear Enterprises Ltd., NE7021) they are not offered as a standard accessory for most common makes of γ counter and do not appear to be readily available from commercial sources.This communication describes a simple, low cost γ flow cell constructed for use in a study on selenium transport in higher plants, which involved the separation of 75Se-labeled constituents in a large number of samples of xylem sap.  相似文献   

13.
A procedure for the extraction, separation, and measurement of photosynthetically fixed 14C in up to 8 chemical fractions (CHCl), amino acids, organic acids, sugars, protein, starch, hemicellulose, and residue) from small samples (1 to 100 mg) of cottonwood (Populus deltoides Bartr.) leaf material is described. The different chemical fractions are extracted in a sequence of chemical, ion exchange, and enzymatic steps. The 14C-activity in these major fractions is then determined with liquid scintillation spectrometry. These major fractions (e.g., sugars, amino acids, organic acids) can be further separated into their individual chemical components by standard thin-layer or gas- chromatographic methods for quantitative analysis if specific activities are desired. The major advantage of the procedure is that many chemical fractions can be sequentially separated with good reproducibility from a small amount of plant material without transfer of the material from the original homogenizer or centrifuge tube.  相似文献   

14.
The counting rate of [1-14C]trichloroacetic acid (TCA) was not stable in a standard toluene/Triton X-100 liquid scintillation solution because this compound becomes partially degraded to 14CO2 and CHCl3. Both toluene and Triton were contributing factors in causing this degradation. The NCS solubilizer added to the toluene/Triton scintillation solution trapped 14CO2 and stabilized counting rates of [1-14C]TCA. When [2-14C]TCA was used, 14CHCl3 remained in the scintillation solution resulting in stable counting rates without the addition of NCS.  相似文献   

15.
A method is described for measuring the activity of glucose-6-phosphatase (EC 3.1.3.9) in rat liver. [U-14C]Glucose 6-phosphate, as substrate, is converted by the enzyme to [14C]glucose and inorganic phosphate. The addition of ZnSO4 and Ba(OH)2 at the end of the reaction precipitates phosphate and the unreacted [14C]glucose 6-phosphate, whereas [14C]glucose is not precipitated. After centrifugation, the amount of [14C]glucose formed is determined in a liquid scintillation counter.  相似文献   

16.
A simple, economical method for counting acrylamide gel slices on solid filter paper supports in a toluene-based scintillation cocktail is described. Major advantages of the system include no requirement for either dissolution of the gel or elution of the radioactive material prior to emulsion counting and the direct reutilization of scintillation cocktail and vials. Additionally, 32P-labeled RNA samples can be counted with better relative efficiencies and those labeled with 14C or 33P can be determined at equivalent efficiencies. Tritium was detected less readily, with an absolute efficiency of approximately 10%.  相似文献   

17.
A method for the liquid scintillation counting of precipitated protein from red cells in 0.1–1.0 ml of blood is described. Precipitate is incubated for 0.5 hr at 100°C with equal volumes of acetic acid, ethyl acetate, and hydrogen peroxide; an equal volume of hydrochlorie acid is then added, followed by a toluene/Triton X-100 scintillation mixture containing primary and secondary scintillators. Maximum counting efficiencies with precipitate from 0.2 ml of blood were 90% for 14C and 35% for 3H. Recovery of labeled amino acid was not less than 90%. Chemiluminescence decayed to not more than 15 cpm above background in 45 min.  相似文献   

18.
A rapid and simple method for counting radioactivity in tissue samples containing [3H]- or [14C]-cholesterol is described.Up to 500 μl of the specimen to be counted (plasma, tissue homogenate) is measured into a counting vial. The lipids of the tissue are extracted into 15 ml of a toluene-based scintillation mixture containing 37.5% ethylene glycol monomethyl ether that is added to the same vial. With the addition of 1 ml water, two phases form: the upper toluene phase containing all cholesterol together with the scintillating phosphor and the lower water phase containing most of the quenching material. Bleaching to reduce color quenching is not necessary. Chemiluminescence is negligible. The counting efficiencies are appreciably higher than those obtained in aqueous one-phase scintillation systems but lower than those obtained with pure standards in one-phase pure toluene scintillation systems.  相似文献   

19.
A method for the preparation of fecal samples for liquid scintillation counting is described which is rapid, hygienic, and inexpensive. By the use of a novel type of homogenizer, fecal samples can be homogenized while totally enclosed within a sealed, plastic bag, so reducing the possible risk of infection. The subsequent preparation of a clear solution suitable for liquid seintillation counting is performed using an “in-vial” digestion technique which enables any 14CO2 released during digestion to be trapped within the vial.  相似文献   

20.
A sensitive and rapid radiochemical micromethod is described for measuring the activity of acetyl-CoA hydrolase (EC 3.1.2.1). [1-14C]Acetyl-CoA is incubated with tissue homogenates; unhydrolyzed [1-14C]acetyl-CoA is separated from the radiolabeled product, [1-14C]acetate, by adsorption to charcoal. The soluble [1-14C]acetate is measured by liquid scintillation techniques. This procedure makes it possible to measure as little as 0.2 to 0.4 nmol acetate generated per assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号