首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A direct HPLC method was developed for the enantioseparation of pantoprazole using macrocyclic glycopeptide-based chiral stationary phases, along with various methods to determine the elution order without isolation of the individual enantiomers. In the preliminary screening, four macrocyclic glycopeptide-based chiral stationary phases containing vancomycin (Chirobiotic V), ristocetin A (Chirobiotic R), teicoplanin (Chirobiotic T), and teicoplanin-aglycone (Chirobiotic TAG) were screened in polar organic and reversed-phase mode. Best results were achieved by using Chirobiotic TAG column and a methanol-water mixture as mobile phase. Further method optimization was performed using a face-centered central composite design to achieve the highest chiral resolution. Optimized parameters, offering baseline separation (resolution = 1.91 ± 0.03) were as follows: Chirobiotic TAG stationary phase, thermostated at 10°C, mobile phase consisting of methanol/20mM ammonium acetate 60:40 v/v, and 0.6 mL/min flow rate. Enantiomer elution order was determined using HPLC hyphenated with circular dichroism (CD) spectroscopy detection. The online CD signals of the separated pantoprazole enantiomers at selected wavelengths were compared with the structurally analogous esomeprazole enantiomer. For further verification, the inline rapid, multiscan CD signals were compared with the quantum chemically calculated CD spectra. Furthermore, docking calculations were used to investigate the enantiorecognition at molecular level. The molecular docking shows that the R-enantiomer binds stronger to the chiral selector than its antipode, which is in accordance with the determined elution order on the column—S- followed by the R-isomer. Thus, combined methods, HPLC-CD and theoretical calculations, are highly efficient in predicting the elution order of enantiomers.  相似文献   

2.
A model is presented that predicts a defined relationship between chiral SubFC resolution and analysis time. This model is based upon ideal chromatographic behavior and requires column efficiency and selectivity to be independent of mobile phase modifier level and flow rate. The validity of these assumptions was found to be imperfect but acceptable for two model compounds on two commonly used chiral columns. A major implication of the model is that the maximum resolution obtainable with a particular column and mobile phase modifier may be predicted from one injection. The retention time required to obtain a desired resolution is also calculable. This information enables the practitioner to discern quickly the futility of method development efforts. Insufficient maximum resolution predicted from the first injection would require an increase in selectivity to achieve a useful separation. Selectivity may then be altered by temperature, modifier, or stationary phase. The increased column efficiency of SubFC at typical flow rates rescues separations that fail by HPLC, thus shrinking the practitioner's required library of chiral columns. This work demonstrates that SubFC also allows the practitioner to skim through that library very quickly. © 1996 Wiley-Liss, Inc.  相似文献   

3.
Wang X  Ching CB 《Chirality》2002,14(10):798-805
Nadolol, a beta-blocker used in the management of hypertension and angina pectoris, has three chiral centers and is currently marketed as an equal mixture of its four stereoisomers. Enantiomeric separation of nadolol by high-performance liquid chromatography was studied on a column packed with novel heptakis (6-azido-6-deoxy-2, 3-di-O-phenylcarbamolyted) beta-cyclodextrin bonded chiral stationary phase. The retention behavior and resolution of nadolol enantiomers were investigated and discussed with respect to the mobile phase composition and flow rate, pH, ionic strength, and temperature. The optimal separation condition was found; the mobile phase contained 80% buffer solution (1% triethylamine acetate, pH 5.5) and 20% methanol with 0.3 ml/min mobile phase flow rate at a temperature of 20 degrees C. At the optimal conditions, resolution of three stereoisomers of nadolol was obtained with a complete separation of the most active enantiomer, (RSR)-nadolol. Thermodynamic properties including enthalpy and entropy change of binding to the CSP for the enantiomeric separation were also determined.  相似文献   

4.
影响逆流色谱分离效率的动力学因素   总被引:2,自引:0,他引:2  
逆流色谱是一种无固态支撑物的液液色谱,它的色谱动力学过程有其特殊性,分析逆流色谱的动力学过程,推导适用于逆流色谱的速率方程式,结合实验,讨论影响色谱峰展宽的因素;理论推导和实验的结果都显示,管径、容量因子、质量传递系数和流动相液滴的直径和线速度是影响逆流色谱峰展宽的主要因素.  相似文献   

5.
The retention time of 22 barbituric acid derivatives was measured on a narrow-bore porous graphitized carbon (PGC) column using water-dioxane mixtures as mobile phases. The capacity factor (k), theoretical plate number (N), and asymmetry factor (AF) were calculated for each solute in each mobile phase. The relationships between chromatographic characteristics and physicochemical parameters of solutes were elucidated by stepwise regression analysis (SRA). SRA indicated that the binding of barbiturates to the PGC surface is of mixed character electrostatic and apolar interactive forces are equally involved. Sterical correspondence between the surface of the stationary phase and the solutes also exert a significant influence on the retention behavior.  相似文献   

6.
A new high‐performance liquid chromatography (HPLC) method was developed for the enantiomeric resolution of five β‐adrenergic blockers on a Chiralpak IC column (250 mm × 4.6 mm, 5.0 μm particle size) in normal phase mode. The mobile phase used was n‐hexane‐ethanol‐diethylamine in different proportions at the flow rate of 1.0 mL/min with the column temperature of 25°C using a UV detector at 230 nm. The influences of base additives and alcohol modifiers were evaluated and optimized. The maximum resolution values for bevantolol, propranolol carteolol, esmolol, and metoprolol were 4.80, 2.77, 2.09, 2.30, and 1.11, respectively. To gain a better understanding of the interaction between chiral stationary phase and analyte enantiomers, the molecular docking of chiral stationary phase with five pairs of enantiomer was carried out using AutoDock molecular docking technique. By simulation studies, the mechanism of chiral recognition was determined. According to the results, hydrogen bond interactions and π‐π interactions were the chief interactions for the chiral recognition.  相似文献   

7.
The enantioseparation of ezetimibe stereoisomers by high‐performance liquid chromatography on different chiral stationary phases, ie, 3 polysaccharide‐based chiral columns, was studied. It was observed that cellulose‐based Chiralpak IC column exhibited the best resolving ability. After the optimization of mobile phase compositions in both normal and reversed phase modes, satisfactory separation could be obtained on Chiralpak IC column, especially in normal phase mode. The use of prohibited solvents as nonstandard mobile phase gave rise to better resolution than that of standard mobile phases (n‐hexane/alcohol system). In addition, the presence of ethanol in nonstandard mobile phase has played an important role in enhancing chromatographic efficiency and resolution between ezetimibe stereoisomers. Various attempts were made to comprehensively compare the chiral recognition capabilities of immobilized versus coated polysaccharide‐based chiral columns, amylose‐based versus cellulose‐based chiral stationary phases, reversed versus normal phase modes, and standard versus nonstandard mobile phases. Moreover, possible solute‐mobile phase‐stationary phase interactions were derived to explain how stationary and mobile phases affected the separation. Then the method validation with respect to selectivity, linearity, precision, accuracy, and robustness was carried out, which was demonstrated to be suitable and accurate for the quantitative determination of (RRS)‐ezetimibe impurity in ezetimibe bulk drug.  相似文献   

8.
Because chiral liquid chromatography (LC) could become a powerful tool to estimate racemic atenolol quantity, excellent enantiomeric separation should be produced during data acquisition for satisfactory observation of atenolol concentrations throughout the racemic resolution processes. Selection of chiral LC column and analytical protocol that fulfill demands of the ultra fast LC analysis is essential. This article describes the characteristics of atenolol chromatographic separation that resulted from different resolution media and analytical protocols with the use of a Chiralcel® OD column. The chromatograms showed quite different characteristics of the separation process. The single enantiomer and racemic atenolol could be recognized by the Chiralcel® OD column in less than 20 min. Symmetrical peaks were obtained; however, several protocols produced peaks with wide bases and slanted baselines. Observations showed that efficient enantioresolution of racemic atenolol was obtained at slow mobile phase flow rate, decreased concentration of amine‐type modifier but increased alcohol content in mobile phase and highest ultraviolet detection wavelength were required. The optimal ultra fast LC protocol enables to reduce and eliminate the peaks of either the atenolol solvent or the buffers and provided the highest peak intensities of both atenolol enantiomers. Chirality 24:356–367, 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

9.
Direct enantioseparation of mandelic acid by high-performance liquid chromatography (HPLC) with a reversed phase column and a mobile phase containing a small amount of hydroxylpropyl-β-cyclodextrin (HP-β-CD) was studied as an efficient method for saving consumption of the CD additive. As a result, it was proposed that racemic mandelic acid can be analyzed with a phenyl column by using a mobile phase composed of 10 mM ammonium acetate buffer (pH 4.2) and 0.02% (w/v) HP-β-CD at a flow rate of 1.0 mL/min at 40°C after the passage of 10 mM ammonium acetate buffer (pH 4.2) containing 0.1% (w/v) HP-β-CD as a precoating mobile phase for 60 min. It is suggested that HP-β-CD is bound with a phenyl group on the surface of the stationary phase to allow a phenyl column to act as a transient chiral column, and injected mandelic acid can form the ternary complex with the adsorbed HP-β-CD. The longer retention time of D-mandelic acid than the L-isomer for HPLC can be explained from the higher stability of the HP-β-CD complex with D-mandelic acid, which was confirmed by CE experiment with HP-β-CD as a selector. The efficiency of a phenyl column compared with other stationary phases was also discussed.  相似文献   

10.
A superficially porous particle (SPP)‐based hydroxypropyl‐β‐cyclodextrin (HPBCD) chiral stationary phase (CSP) was produced and its chromatographic performance was compared to both 5 µm and 3 µm fully porous particle (FPP)‐based CSPs. The relative surface coverage of the HPBCD chiral selector on each particle was approximately equal, which resulted in equivalent enantiomeric selectivity (α) values on each phase when constant mobile phase conditions were used. Under such conditions, the SPP column resulted in greatly reduced analysis times and three times greater efficiencies compared to the FPP columns. When higher flow rates were used, efficiency gains per analysis times were five times greater for the SPP column compared to the FPP‐based columns. When the mobile phases were altered to give similar analysis times on each column, resolution values were doubled for the SPP column. Finally, the novel SPP based HPBCD column proved to be stable for 500 injections under high flow rate (4.5 mL/min) and high pressure (400 bar) conditions used for an ultrafast (~45 sec) enantiomeric separation. Chirality 27:788–794, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

11.
A novel liquid chromatographic method was developed for enantiomeric separation of lorcaserin hydrochloride on Chiralpak IA column containing chiral stationary phase immobilized with amylose tris (3.5‐dimethylphenylcarbamate) as chiral selector. Baseline separation with resolution greater than 4 was achieved using mobile phase containing mixture of n‐hexane/ethanol/methanol/diethylamine (95:2.5:2.5:0.1, v/v/v/v) at a flow rate of 1.2 mL/min. The limit of detection and limit of quantification of the S‐enantiomer were found to be 0.45 and 1.5 μg/mL, respectively; the developed method was validated as per ICH guideline. The influence of column oven temperatures studied in the range of 20°C to 50°C on separation was studied; from this, retention, separation, and resolution were investigated. The thermodynamic parameters ΔH°, ΔS°, and ΔG° were evaluated from van't Hoff plots,(Ink′ versus 1/T) and used to explain the strength of interaction between enantiomers and immobilized amylose–based chiral stationary phase  相似文献   

12.
The effect of mobile phase velocity, separation time, support pore diameter, column length, and temperature on resolution and loading capacity of a new commercially available high-performance anion-exchange support, SynChropak AX-300, has been examined. This material is a macroporous spherical silica of 10 μm particle size with a bonded polymeric amine layer. It was found that the heterogeneity of ovalbumin samples, combined with bovine serum albumin, make them useful probes in evaluation of anion-exchange supports. In the columns of 4.1 mm i.d., the highest resolutions of proteins were achieved at a flow rate of 0.25 ml/min. Up to 10 mg of protein per injection could be applied on a 4.1 × 250 mm AX-300 column with good resolution. Columns of 50 mm length had one-tenth the protein load capacity of a 250-mm column, retaining approximately 75% of the resolution.  相似文献   

13.
There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.  相似文献   

14.
The use of immobilized human serum albumin (HSA) as a stationary phase in affinity chromatography has been shown to be useful in resolving optical antipodes or to investigate interactions between drugs and protein. However, to our knowledge, no inorganic ion binding has been studied on this immobilized protein type. To do this, the human serum albumin stationary phase was assimilated to a weak cation-exchanger by working with a mobile phase pH equal to 6.5. A study of the eluent ionic strength effect on ion retention was carried out by varying the buffer concentrations and the column temperatures. The thermodynamic parameters for magnesium and calcium transfer from the mobile to the stationary phase were determined from linear van’t Hoff plots. An enthalpy–entropy compensation study revealed that the type of interaction was independent of the mobile phase composition. A simple model based on the Gouy–Chapman theory was considered in order to describe the retention behavior of the test cations with the mobile phase ionic strength. From this theoretical approach, the relative charge densities of the human serum albumin surface implied in the binding process were estimated at different column temperatures.  相似文献   

15.
Cemil Aydoğan 《Chirality》2018,30(10):1144-1149
A novel chiral porous‐layer stationary phase was developed for use in open‐tubular nano liquid chromatography. The stationary phase was prepared by an in‐situ polymerization of 3‐chloro‐2‐hydroxypropylmethacrylate (HPMA‐Cl) and ethylene dimethacrylate (EDMA). The reactive chloro groups at the surface of the porous stationary phase were reacted with β‐Cyclodextrin (β‐CD). The resulting morphology was characterized by using scanning electron microscopy (SEM) and Fourier‐transform infrared spectroscopy (FT‐IR). The chromatographic performance of the column was evaluated by hydrophilic interaction chromatography (HILIC). Amino acids were used as test solutes. The running buffer conditions for the enantioseparation were found to be 85% acetonitrile (ACN):10%MeOH: 5% H2O at 0.1% v/v trifluoro acetic acid (TFA) (flow rate: 800 nL/min). The enantioseparation provided high theoretical plate numbers up to 26 000 platesm?1. A good retention capacity within satisfactory retention times was also achieved. Real sample applicability of this column to the separation of amino acid enantiomers in fruit juice sample was demonstrated.  相似文献   

16.
The performance of protein separation using the figure-8 column configuration in centrifugal counter-current chromatography was investigated under various flow rates and revolution speeds. The separation was performed with a two-phase solvent system composed of polyethylene glycol 1000/potassium phosphate each at 12.5% (w/w) in water and with lysozyme and myoglobin as test samples. In order to improve tracing of the elution curve, a hollow fiber membrane dialyzer was inserted at the inlet of the UV detector. The results showed that the retention of stationary phase (Sf) and resolution (Rs) increased with decreased flow rate and increased revolution speed. The highest Rs of approximately 1 was obtained at a flow rate of 0.01 mL/min under a revolution speed of 1200 rpm with a 3.4 mL capacity column.  相似文献   

17.
In this study, a new Pirkle‐type chiral column stationary phase for resolution of β‐methylphenylethyl amine was described by using activated Sepharose 4B as a matrix, L ‐tyrosine as a spacer arm, and an aromatic amine derivative of L ‐glutamic acid as a ligand. The binding capacities of the stationary phase were determined at different pH values (pH = 6, 7, and 8) using buffer solutions as mobile phase, and enantiomeric excess (ee) was determined by HPLC equipped with chiral column. The ee was found to be 47%. Chirality, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

18.
R Gollamudi  Z X Feng 《Chirality》1991,3(6):480-483
alpha,alpha'-Bis[3-(N,N-diethylcarbamoyl)piperidino]-p-xylene dihydrobromide, a novel antiplatelet agent, was resolved into three isomers A, B, and C, on a chiral alpha 1-acid glycoprotein analytical column using a mobile phase of 0.025 M phosphate buffer containing 0.025 M tetrabutylammonium hydrogen sulfate, at a pH of 6.5. The effect of molarity, temperature, pH, flow rate, and organic modifiers on the enantioselectivity was examined. Based on circular dichroic spectra at 220 nm, A and C appear to be the (-)- and (+)-enantiomers, respectively, and B the meso diastereomer. Attempts at resolution using Pirkle type columns gave unsatisfactory results. It appears that both hydrophobic and polar interactions between the compound and the stationary phase are important determinants of resolution.  相似文献   

19.
Perfluorooctane sulfonate (PFOS) is one of the most frequently detected perfluoroalkyl substances in environmental and human samples. Previous studies have shown that nonracemic PFOS in biological samples can be used as a marker of PFOS exposure sources. In recent years, supercritical fluid chromatography (SFC) has emerged as a powerful method to separate chiral compounds. In this study, a method of perfluoro‐1‐methylheptane sulfonate (1 m‐PFOS) enantioseparation by SFC was established. The optimal separation was obtained using a Chiralpak QN‐AX column with CO2/2‐propanol (70/30, v/v) as the mobile phase with a flow rate of 1 mL/min, column temperature was 32°C, and BPR pressure was 1800 psi. The resolution (Rs) and retention time were 0.88 and 130 minutes, respectively. This method is more economic and greener than HPLC. Modifier pH and column temperature were determined to be significant factors of SFC chiral separation. Modifier pH is negatively correlated with the retention factors and Rs. Adsorption thermodynamics were used to explain the influence of temperature change, and it was concluded that the transfer of two enantiomers from the mobile phase to the stationary phase is enthalpy‐driven. Enantioseparation of 1 m‐PFOS by SFC follows the same rules of ion exchange as those for the chiral separation by HPLC.  相似文献   

20.
A direct chiral chromatographic reversed phase method for the determination of the enantiomers of felodipine is described. The influence of charged and uncharged modifiers as well as the effect of the mobile phase pH on the enantiomeric resolution is discussed. A high mobile phase pH and the addition of 2-propanol as organic modifier gave the highest separation factor (α = 1.3). The high mobile phase pH (pH = 7.6) is outside the recommended pH limit of silica based columns but was necessary to achieve baseline resolution of (R)- and (S)-felodipine. Improvement of column efficiency by increasing column temperature was utilized for optimization of the enantiomeric resolution (Rs = 1.7). The enantiomers of felodipine and three related compounds were separated within 15 min. The enantiomeric purity of (R)- and (S)-felodipine in injections and (R)-felodipine in bulk substance was higher than 99.5% and no racemization was observed after storage at accelerated conditions. A poor Chiral-AGP® column used for a long period was restored using a simple wash step together with repacking the top of the chromatographic column. © 1995 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号