首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Electrically active polyaniline coated magnetic (EAPM) nanoparticle-based biosensor has been developed for the detection of Bacillus anthracis endospores in contaminated food samples. The 100 nm-diameter EAPM nanoparticles are synthesized from aniline monomer (made electrically active by acid doping) coating the surface of gamma iron oxide cores. The magnetic, electrical, and structural characteristics of the synthesized EAPM nanoparticles have been studied using superconducting quantum interference device (SQUID), four-point probe, and transmission electron microscopy (TEM). Room temperature hysteresis of the synthesized nanoparticles shows a saturation magnetization value of 44.1 emu/g. The EAPM nanoparticles are biologically modified to act as an immunomagnetic concentrator of B. anthracis spores from lettuce, ground beef and whole milk samples and are directly applied to a direct-charge transfer biosensor. The detection mechanism of the biosensor depends on the capillary flow of the captured spores on the biosensor surface along with direct-charge transfer across the EAPM nanoparticles. Experimental results indicate that the biosensor is able to detect B. anthracis spores at concentrations as low as 4.2 x 10(2)spores/ml from the samples. The EAPM-based biosensor detection system is fast and reliable with a total detection time of 16 min.  相似文献   

2.
AIMS: The aim of this study is to evaluate the AGID serological test for detection of antibodies anti-Mycobacterium paratuberculosis and its possible adoption as diagnostic method in our field conditions. METHODS: Bovine serum samples from dairy herds in Rio de Janeiro State, Brazil, were screened for the presence of antibodies against Myco. paratuberculosis using three different ELISA tests. A panel of 48 randomly selected sera were evaluated by an Agarose Gel Immunodiffusion (AGID) test using Protoplasmatic Paratuberculosis Antigen (PPA). AGID results were compared to the standards--the results of the three ELISA tests, and the specificity and sensitivity were calculated. RESULTS: From 48 sera tested for AGID, 14 (29.17%) were positive and 34 (70.83%) were negative. AGID sensitivity was 57% with two false-positive reactions, and specificity was 92.5% with nine false-negative results. The positive predictive value was calculated in 85.7% for a confidence interval of 95%. SIGNIFICANCE AND IMPACT OF THE STUDY: Due to its low sensitivity and specificity rates, AGID test has shown to be unsatisfactory as a screening diagnostic method for subclinical herd infection, but it can be useful as a confirmatory test for clinical suspect animals.  相似文献   

3.
A chitosan-glutaraldehyde crosslinked uricase was immobilized onto Prussian blue nanoparticles (PBNPs) absorbed onto carboxylated multiwalled carbon nanotube (c-MWCNT) and polyaniline (PANI) layer, electrochemically deposited on the surface of Au electrode. The nanohybrid-uricase electrode was characterized by scanning electron microscopic (SEM), Fourier transform infrared spectroscopy (FTIR) and cyclic voltammetry. An amperometric uric acid biosensor was fabricated using uricase/c-MWCNT/PBNPs/Au electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode connected through a potentiostat. The biosensor showed optimum response within 4 s at pH 7.5 and 40 °C, when operated at 0.4 V vs. Ag/AgCl. The linear working range for uric acid was 0.005-0.8 mM, with a detection limit of 5 μM. The sensor was evaluated with 96% recovery of added uric acid in sera and 4.6 and 5.4% within and between batch of coefficient of variation respectively and a good correlation (r = 0.99) with standard enzymic colorimetric method. This sensor measured uric acid in real serum samples. The sensor lost only 37% of its initial activity after its 400 uses over a period of 7 months, when stored at 4 °C.  相似文献   

4.
Blood serum samples from 2,328 dogs were tested to detect antibodies against Brucella canis with the agar gel immunodiffusion (AGID) and 2-mercaptoethanol slide agglutination test (ME-SAT) using Brucella ovis as the antigen. All blood serum samples were also evaluated for antibodies against Brucella abortus and Brucella melitensis using the Rose Bengal test. Twentyfive (1.07%) of the sera evaluated were considered positive with AGID test. Only 4 (16%) of these blood serum samples were positive when evaluated with ME-SAT. The 25 AGID positive samples and 25 AGID negative serum samples were also examined by: the complement fixation test (CFT) using B. ovis hot saline extract (HSE) as the antigen, indirect enzyme linked immunosorbent assay (ELISA) and immunoblotting (IB) using B. canis and B. ovis HSE antigens. Two positive canine sera from culture positive dogs and the serum of an experimentally RM6/66 B. canis-infected rabbit were employed as positive controls and one serum from a known uninfected dog as a negative control. ELISA with B. canis antigen gave 9 (18%) positive results (6 AGID-positive and 3 AGID-negative sera). ELISA performed with B. ovis antigen detected 15 (30%) positive samples (10 AGID-positive, 5 AGID-negative and 8 B. canis ELISA positive sera). IB analysis of known positive controls sera employing B. canis antigen detected bands with molecular weights of 94-80, 64-50, 35, 32-30, 28, 23, 20-18, 15-12 kDa. The same sera tested with B. ovis antigen revealed bands of 35, 32-30, 25, 23, 20-18, 15-12 kDa. No bands were observed with the negative control serum and the 50 canine tested sera.  相似文献   

5.
《Small Ruminant Research》2010,88(1-3):92-95
Due to the absence of previous reports, the goal of this work was to detect caseous lymphadenitis (CLA) in goat flocks from Venezuela using an indirect immunoenzymatic assay (ELISA). Eighteen farms were randomly selected in Falcon State, North-Western Venezuela. Blood samples were taken from 259 goats, 65 of them with abscesses. Experimental inoculations were made to healthy kids with 0.5 mL inocula containing 4.7 × 105 of Corynebacterium pseudotuberculosis to observe the kinetics of antibody response. Immunoenzymatic assays were carried out using exotoxin of C. pseudotuberculosis as antigen. Antibody response in experimentally inoculated animals was detected 2 weeks after infection. Of 259 field goat sera, 55.98% were positive by ELISA. Of 65 goats with abscesses, 67.69% had CLA demonstrated by bacteriological methods; from these, 72.73% showed antibodies by ELISA. Of the remaining goats negative to CLA, 47.62% had antibodies by ELISA. Sensitivity was calculated in 72.73% and specificity in 67.74%. The immunoenzymatic assay applied in this research could be useful to detect CLA in naturally infected goat flocks from Venezuela.  相似文献   

6.
Heavy chain antibodies (HCAbs) of IgG2 and IgG3 subtypes were purified from the sera of Indian desert camel (Camelus dromedarius L.) by ammonium sulphate precipitation, followed by ion-exchange chromatography on DEAE-cellulose and affinity chromatography on protein A-sepharose and protein G-sepharose, and characterized by SDS-polyacrylamide gel electrophoresis, agar gel immunodiffusion (AGID), counter-immunoelectrophoresis (CIEP), immunoelectrophoresis (IEP), ELISA and immunoblotting. IgG2 and IgG3 were found to have molecular mass 46.77 kDa and 43.65 kDa, respectively by SDS-PAGE under reducing conditions. They migrated in beta-region in IEP and could be detected in CIEP, because of being more negatively charged and smaller size. Anti-camel IgG3 cross-reacted in AGID, ELISA and immunoblotting with IgGs of pig and ruminants (cattle, buffalo, sheep and goat), but not with immunoglobulins from horse, dog, guinea pigs, mice, fish, poultry and human. The present findings suggest close antigenic relationship of camels with pigs and ruminants.  相似文献   

7.
This paper reports a micro-machined piezoelectric membrane-based biosensor array for immunoassay. Goat immunoglobulin G (IgG) and HBsAg were immobilized as the probe molecules on the square piezoelectric membranes of the sensors that have dimensions of 3.5 microm x 500 microm x 500 microm. Due to the mass sensitive nature of these sensors, their resonant frequencies were depressed after the anti-goat IgG or anti-HBsAg was captured by the goat IgG or HBsAg. The resonant frequencies of the sensors were measured by an impedance analyzer. The experimental results demonstrate that the measured frequency change varies from 100 to 700 Hz, and the mass sensitivity of the device is estimated to be about 6.25 Hz/ng. A near linear relationship between the frequency change and the concentration of goat IgG was obtained, and the mass of the attached anti-goat IgG was calculated. The preliminary results discussed in this work indicate that the micro-machined piezoelectric membrane-based biosensor has a potential application as an immunosensor.  相似文献   

8.
We describe the preparation of glutaraldehyde cross-linked and functionalized cholesterol esterase nanoparticles (ChENPs) and cholesterol oxidase nanoparticles (ChOxNPs) aggregates and their co-immobilization onto Au electrode for improved amperometric determination of serum total cholesterol. Transmission electron microscope (TEM) images of ChENPs and ChOxNPs showed their spherical shape and average size of 35.40 and 56.97 nm, respectively. Scanning electron microscope (SEM) studies of Au electrode confirmed the co-immobilization of enzyme nanoparticles (ENPs). The biosensor exhibited optimal response at pH 5.5 and 40 °C within 5 s when polarized at +0.25 V versus Ag/AgCl. The working/linear range of the biosensor was 10–700 mg/dl for cholesterol. The sensor showed high sensitivity and measured total cholesterol as low as 0.1 mg/dl. The biosensor was evaluated and employed for total cholesterol determination in sera of apparently healthy and diseased persons. The analytical recovery of added cholesterol was 90%, whereas the within-batch and between-batch coefficients of variation (CVs) were less than 2% and less than 3%. There was a good correlation (r = 0.99) between serum cholesterol values as measured by the standard enzymic colorimetric method and the current method. The initial activity of ENPs/working electrode was reduced by 50% during its regular use (200 times) over a period of 60 days when stored dry at 4 °C.  相似文献   

9.
A survey was carried out to verify if an immunohistochemical method associated with agar gel immunodiffusion (AGID) will establish a firm diagnosis of caprine paratuberculosis. One hundred and thirty-six goats were tested by AGID for antibodies against Mycobacterium avium subsp. paratuberculosis at two different times: the first time 22 (19.1%) were positive and the second time 25 (18%). One seronegative goat with severe diarrhea and 5 seropositive goats, two of which showing similar clinical signs, were sacrificed and necropsied. Samples were taken from small intestine, liver, spleen, mesenteric lymph nodes for bacteriological, histological and immunohistochemical examinations. M.a. paratuberculosis was isolated from intestine samples of 4 seropositive goats and from mesenteric lymph nodes of one seropositive goat; the microorganism was not isolated from samples of one seropositive and the seronegative animals. Ziehl Neelsen staining showed acid-fast bacilli in macrophages of the 5 seropositive animals and the immunohistochemical method for M. a. paratuberculosis detected bacterial antigen in the same samples.  相似文献   

10.
Fang X  Tie J  Xie Y  Li Q  Zhao Q  Fan D 《Cancer epidemiology》2010,34(5):648-651
Background: MG7-Ag is a kind of gastric cancer-specific tumor-associated antigen and has been investigated to serve as a marker of gastric cancer for early diagnosis. Methods: Surface plasmon resonance (SPR) sensor was used for the detection of MG7-Ag in the sera of gastric cancer patients to develop an innovative, simple and rapid assay method for early diagnosis. The specific monoclonal MG7 antibodies were used as capture and detection receptors which were immobilized on the surface of SPR sensor chips for MG7-Ag identification in the human sera. The measurements include 9 cases of gastric cancer patients and 2 cases of healthy blood donors and a MKN45 cancer cell lysate solution sample for positive control. Results: The binding of MG7-Ag onto the sensor surface was observed from SPR spectra. The sera of most gastric cancer patients revealed much higher expression level of MG7-Ag than healthy human sera did in SPR measurement. Conclusion: The initial results demonstrate that the SPR biosensor has the potential for its application in the early diagnosis of gastric cancer. However, more tests need to be done to confirm the detection limitation and the criterion for cancer risk evaluation in early diagnosis.  相似文献   

11.

Wild carnivores are at the top of the trophic chain. They are predators and carrion consumers, and thus, prone to come in contact with disease agents contaminating the environment or infecting live or dead animals. We hypothesized that wild canids could be used as sentinels for the detection of regions with higher Mycobacterium avium paratuberculosis (MAP) prevalence in wild and domestic animals. To test this hypothesis, we set up an ELISA to test 262 wolf (Canis lupus) and fox (Vulpes vulpes) sera for MAP-specific antibodies and processed a subset of samples for culture (n = 61), MAP-specific PCR (15) and histopathology (14). In wolves, the optical density (OD) values in the ELISA were continuously distributed. Ten fox sera (4%) had OD readings of over twice the mean, suggesting contact with mycobacteria. However, all samples tested by PCR were negative for both IS900 and ISMAP02 sequences, and samples cultured for MAP yielded no growth. No visible paratuberculosis or tuberculosis-compatible lesions were recorded. On histopathological examination, no lesions compatible with mycobacterial diseases were observed. These results suggest that wild canids show little or no evidence of paratuberculosis and are unlikely to be useful sentinels for the detection of MAP in Southwestern Europe.

  相似文献   

12.
Procedures for IgG depletion in visceral leishmaniasis (VL) and schistosomiasis sera using Sepharose-protein G beads also deplete IgE. In this study, the presence of IgG anti-IgE autoantibodies in sera from patients with VL (n = 10), and hepatic-intestinal schistosomiasis (n = 10) and from healthy individuals (n = 10) was investigated. A sandwich ELISA using goat IgG anti-human IgE to capture serum IgE and goat anti-human IgG peroxidase conjugate to demonstrate the binding of IgG to the IgE captured was performed. VL sera had higher titers (p < 0.05) of IgG anti-IgE autoantibodies (OD = 2.01 +/- 0.43) than sera from healthy individuals (OD = 1.35 +/- 0.16) or persons infected with Schistosoma mansoni (OD = 1.34 +/- 0.18). The immunoblotting carried out with eluates from Sepharose-protein G beads used to deplete IgG from these sera and goat anti-human IgE peroxidase conjugate, showed a similar pattern of bands, predominating the 75 kDa epsilon-heavy chain and also polypeptides resulting from physiological enzymatic digestion of IgE. A frequent additional band immediately above 75 kDa was observed only in VL sera.  相似文献   

13.
Toxoplasma gondii IgG antibodies were measured in 212 goat sera, comparing the Sabin-Feldman dye-test and a three-layer sandwich enzyme-linked immunosorbent assay (ELISA). With 98 % concordance obtained between these 2 tests, the results are at the same paragon as for human sera. Accordingly, the ELISA sandwich procedure appears to be suitable for large-scale analysis of goat sera. The discordant 2 % were ELISA positive and dye-test negative. One possible explanation of the divergent titres is given using an immunized goat model.  相似文献   

14.
A comparison was made of results obtained with a Brucella agar--gel immunodiffusion (AGID) test and the standard tube-agglutination test on 612 human sera. Agreement between the tests was 97% when the titer was 1:160 or higher. Of 448 sera that showed no agglutination titer, 447 were negative with the AGID test. Results of the AGID test were also compared to those obtained with the 2-mercaptoethanol (2-ME) agglutination test on 148 sera that demonstrated a standard tube-agglutination titer of 1:20 or higher. All sera with a 2-ME-agglutination titer of 1:40 or higher were positive with the AGID test. Of 123 sera that showed no 2-ME-agglutination titer, 21 were positive with the AGID test. Two of these 21 sera were obtained from patients with bacteriologically proven brucellosis, and eight were from abattoir employees with suspected but not bacteriologically proven brucellosis.  相似文献   

15.
Background and Aims:  Infection with Helicobacter hepaticus is suggested to play a role in the pathogenesis of chronic liver disease in humans. However, reactive antigens among Helicobacter species make the development of an H. hepaticus ELISA test with high specificity difficult. A new monoclonal antibody from a hybridoma clone (HRII-51) showed high specificity to H. hepaticus without cross-reaction to other gastrointestinal bacteria.
Methods:  The molecular weight of HRII-51 immunoreactive antigen was examined by Western blot of H. hepaticus probed with the monoclonal antibody HRII-51. A HRII-51-immunoreactive antigen capture ELISA was prepared in which the specific antigen was anchored by HRII-51-immobilized ELISA plate. Accuracy of HRII-51 antigen capture ELISA was examined using sera obtained from mice inoculated with Helicobacter species. Specificity of HRII-51 antigen capture ELISA was compared to that of H. hepaticus antigen-based ELISA using human sera with absorption by H. pylori cell lysate.
Results:  HRII-51 immunoreactive antigen had a molecular weight of 15 kDa. Sensitivity and specificity of HRII-51 antigen capture ELISA were 87.0% and 97.6% in mice inoculated with Helicobacter species. In human sera, modification of the results by absorption with H. pylori lysate was smaller in HRII-51 antigen capture ELISA comparing with H. hepaticus -antigen-based ELISA.
Conclusion:  Use of the HRII-51 antigen capture ELISA would be a useful approach for the serodiagnosis of H. hepaticus infection in both experimental animals and humans.  相似文献   

16.
Streptavidin, as a dopant, has been incorporated into a polypyrrole film to bind biotinylated antibody onto the electrode surface. With four biotin binding sites, the incorporation of streptavdin, as confirmed by FTIR and impedance spectroscopy, provided a new method to amplify the response signal from antibody–antigen interaction. Biotinylated anti-goat IgG, as a probe, and goat IgG, as a target, were employed to evaluate the characteristics of the biosensor. With the amplification strategy, the detection sensitivity of the electrochemical impedance spectroscopy was significantly improved. A linear relationship between the charge transfer resistance change (ΔRt) and the concentration of goat IgG ranging from 10 pg/ml to100 ng/ml was obtained.  相似文献   

17.
During anemic episodes, goats and certain sheep replace hemoglobin A (HbA = α2β2A) with hemoglobin C (HbC = α2β2C). Rabbit serum directed against either purified sheep HbA or purified sheep HbC was prepared. Both types were used to test whether the two hemoglobins are found in the same cell during switching by an indirect fluorescent antibody assay.Unabsorbed antisheep HbA cross-reacted extensively with goat HbA but to a lesser extent with goat or sheep HbC. Similarly, unabsorbed antisheep HbC reacted with these antigens in the order: Sheep HbC > goat HbC > sheep HbA > goat HbA. Cross-absorption resulted in sera specific either for sheep and goat HbA or for sheep and goat HbC. The specificities were confirmed by indirect fluorescent antibody staining of sheep and goat erythrocytes containing either at least 99% HbA or at least 99% HbC.Smears of erythrocytes from sheep and goats in the process of switching were reacted with one of the absorbed sera then with fluorescein conjugated antirabbit immunoglobulin G. The sum of the fractions stained both by anti-HbA and by anti-HbC exceeded 100% during the switch. Most strikingly when HbA was replacing HbC, nearly all cells stained for HbC while more than half stained for HbA. Thus, the two hemoglobins are found in the same cell during switching.  相似文献   

18.
Mycobacterium avium paratuberculosis (Map) is a pathogen which causes a chronic progressive granulomatous enteritis known as paratuberculosis or Johne’s disease and it primarily affects wild and domestic ruminants. The aim of this research was to examine a flock which consisted of 294 goats and was located in Garfagnana district (Tuscany, Italy) performing ELISA tests, culture and IS900 PCR assay; direct diagnostic methods were carried out not only on bulk tank milk and cheese samples but also on individual milk and tissue specimens collected from nine subjects positive to ELISA tests. Out of 294 animals, 20 goats (6.8%) were positive to ELISA surveys. Bulk tank milk samples were negative to culture and to PCR assay carried out on the DNA extracted directly from them, while, with respect to cheese, Map was detected by culture in 2/12 (16.66%) cheeses ripened for 3–7 days, and by PCR in 2/12 (16.66%) cheeses ripened for 3–7 days and in 3/12 (25%) cheeses ripened for 45 days. Regarding individual milk samples, Map was detected by culture in 2/9 (22.22%) specimens and by PCR in 5/9 (55.55%) samples. Furthermore, Map was isolated from the intestine in 9/9 (100%) animals, from the mesenteric lymph nodes in 8/9 (88.88%) subjects, from the liver in 4/9 (44.44%) goats, from the spleen in 5/9 (55.55%) animals, while Map DNA was found in all the tissue samples analyzed.The results demonstrated the presence of paratuberculosis in a goat flock located in Garfagnana district (Tuscany, Italy).  相似文献   

19.
We demonstrate a label-free peptide-coated carbon nanotube-based immunosensor for the direct assay of human serum. A rheumatoid arthritis (RA)-specific (cyclic citrulline-containing) peptide, was immobilized to functionalized single-walled carbon nanotubes deposited on a quartz crystal microbalance (QCM) sensing crystal. Serum from RA patients was used to probe these nanotube-based sensors, and antibody binding was detected by QCM sensing. Specific antibody binding was also determined by comparing the assay of two serum control groups (normal and diseased sera), and the native unmodified peptide. The sensitivity of the nanotube-based sensor (detection in the femtomol range) was higher than that of the established ELISA and recently described microarray assay systems, detecting 34.4 and 37.5% more RA patients with anti-citrullinated peptide antibodies than those found by ELISA and microarray, respectively. There was also an 18.4 and 19.6% greater chance of a negative test being a true indicator of a person not having RA than by either ELISA or microarray, respectively. The performance of our label-free biosensor enables its application in the direct assay of sera in research and diagnostics.  相似文献   

20.
Between 2 August and 22 September 2000, 37 hunter-killed tule elk (Cervus elaphus nannodes) were evaluated at the Grizzly Island Wildlife Area, California, USA, for evidence of paratuberculosis. Elk were examined post-mortem, and tissue and fecal samples were submitted for radiometric mycobacterial culture. Acid-fast isolates were identified by a multiplex polymerase chain reaction (PCR) that discriminates among members of the Mycobacterium avium complex (MAC). Histopathologic evaluations were completed, and animals were tested for antibodies using a Johne's enzyme-linked immunosorbent assay (ELISA) and agar gel immunodiffusion. In addition, 104 fecal samples from tule elk remaining in the herd were collected from the ground and submitted for radiometric mycobacterial culture. No gross lesions were detected in any of the hunter-killed animals. Mycobacterium avium subsp. paratuberculosis (MAP) was cultured once from ileocecal tissue of one adult elk and was determined to be a strain (A18) found commonly in infected cattle. One or more isolates of Mycobacterium avium subsp. avium (MAA) were isolated from tissues of five additional adult elk. Gastrointestinal tract and lymph node tissues from 17 of the 37 elk (46%) examined had histopathologic lesions commonly seen with mycobacterial infection; however, acid-fast bacteria were not observed. All MAC infections were detected from adult elk (P = 0.023). In adult elk, a statistically significant association was found between MAA infection and ELISA sample-to-positive ratio (S/P) > or = 0.25 (P=0.021); four of five MAA culture-positive elk tested positive by ELISA. Sensitivity and specificity of ELISA S/P > or = 0.25 for detection of MAA in adult elk were 50% and 93%, respectively. No significant associations were found between MAC infection and sex or histopathologic lesions. Bacteriologic culture confirmed infection with MAP and MAA in this asymptomatic tule elk herd. The Johne's ELISA was useful in signaling mycobacterial infection on a population basis but could not discriminate between MAA and MAP antibodies. The multiplex PCR was useful in discriminating among the closely related species belonging to MAC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号