首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The semi-automatic bioanalytical assays for olpadronate [(3-dimethylamino-1-hydroxypropylidene)bisphosphonate] involves a protein precipitation with trichloroacetic acid and a double co-precipitation with calcium phosphate for serum samples and a triple calcium co-precipitation for urine samples. These manual procedures are followed by an automated solid-phase extraction on a cation-exchange phase. The procedure is continued either directly, at high olpadronate levels in urine, or after off-line evaporation under nitrogen and reconstitution in water on the same robotic workstation. The continued automatic procedure comprehends derivatization with (9-fluorenylmethyl)chloroformate, ion-pair liquid–liquid extraction and ion-pair HPLC with fluorescence detection at 274/307 nm. The intra- and inter-day precisions for urine and serum samples are typically in the 5–8% range for different olpadronate concentrations [levels near the lower limit of quantification (LLQ) excluded]. The LLQ is 5 ng/ml olpadronate for a 2.5-ml urine sample and 10 ng/ml for a 1-ml serum sample, respectively.  相似文献   

2.
GTI-2040 is a 20-mer phosphorothioate oligonucleotide complementary to the mRNA of the R2 subunit of ribonucleotide reductase (RNR). It is under clinical development as an anti-cancer agent. A reverse phase high-performance liquid chromatograph (HPLC) method was established for the quantitative analysis of GTI-2040 in human plasma. Plasma samples were prepared with an initial solid-phase extraction (SPE) followed by a liquid-liquid extraction step. HPLC analysis was performed with a gradient system on a Waters XTerraMS C18 column. The mobile phase consisted of acetonitrile-tetrabutyl ammonium hydrogen sulfate (TBAS) buffer (pH 9.0, 20 mM) at a flow rate of 1.0 ml/min, and the detector was set at a wavelength of 260 nm. A cationic pairing reagent, tetrabutyl ammonium hydrogen sulfate was added during plasma sample clean-up with solid-phase extraction, resulting in significant improvement in extraction recovery. In addition, TBAS addition to the mobile phase improved the peak symmetry of GTI-2040. This method was successfully used in the analysis of GTI-2040 in clinical plasma samples.  相似文献   

3.
A reversed-phase high-performance liquid chromatographic (HPLC) using ultraviolet (UV) absorbance detection method for simultaneous determination of clofibrate (I) and its major metabolite clofibric acid (II) in human plasma has been developed to support a clinical study. I, II and internal standard (I.S., III) are isolated from human plasma by 96-well solid-phase extraction (SPE) C(18)z.ccirf;AR plate and quantified by direct injection of the SPE eluent onto the HPLC with UV detection wavelength at 230 nm. Two chromatographic methods, isocratic and step gradient, have been validated from 1.0 to 100.0 microg/ml and successfully applied to plasma sample analysis for a clinical study. The lower limit of quantitation (LLOQ) is 1.0 microg/ml for both I and II when 500 microl plasma sample is processed. Sample collection and preparation is conducted at 5 degrees C to minimize the hydrolysis of I to II in human plasma.  相似文献   

4.
A sensitive HPLC method has been developed for the assay of imatinib in human plasma, by off-line solid-phase extraction followed by HPLC coupled with UV-Diode Array Detection. Plasma (750 microl), with clozapine added as internal standard, is diluted 3 + 1 with water and subjected to a solid-phase extraction on a C18 cartridge. After matrix components elimination with 2000 microl of water (in two aliquots of 1000 microl), imatinib is eluted with 3 x 500 microl MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 180 microl 50% methanol. A 50 microl volume is injected onto a Nucleosil 100-5 microm C18 AB column. Imatinib is analyzed using a gradient elution program with solvent mixture constituted of methanol and water containing both 0.05% ammonium acetate. Imatinib is detected by UV at 261 nm. The calibration curves are linear between 0.1 and 10 microg/ml. The limit of quantification and detection are 0.05 and 0.01 microg/ml, respectively. The mean absolute recovery of imatinib is 96%. The method is precise with mean inter-day CVs within 1.1-2.4%, and accurate (range of inter-day deviations -0.6 to +0.7%). The method has been validated and is currently being applied in a clinical study assessing the imatinib plasma concentration variability in a population of chronic myeloid leukemia- and gastro-intestinal stromal tumor-patients.  相似文献   

5.
In this study, a method for partly automated sample preparation and fully automated solid-phase extraction method for plasma, kidney and liver samples for various retinoids like all-trans-4-oxo-retinoic acid, 13-cis-4-oxo-retinoic acid, 13-cis-retinoic acid, 9-cis-retinoic acid, all-trans-retinoic acid, retinol and retinyl palmitate was established. Plasma, embryo-, kidney-and liver-homogenates were automatically mixed and extracted on multiple usage solid-phase (C2) extraction cartridges immediately before HPLC analysis. Automated cleaning, preconditioning and incorporation of the loaded cartridge to fully automated HPLC separation and quantification of the various retinoids in a single HPLC run was established. The recovery of the retinoids was generally between 80 and 90%. Intra-day repeatability was < 11.7%. As little as 1.2 ng/ml could be quantified in lipid-mixture standard samples. This method allows a highly automated sample preparation and a fully automated solid-phase extraction with good selectivity for the study of endogenous retinoids and retinoids after nutritional supplementations and pharmacological applications in several biological samples.  相似文献   

6.
Reliable MS-based methods have been developed for the measurement of free and esterified F2-isoprostanes. However, prior to sample analysis several steps of purification, including solid-phase extraction followed by TLC or HPLC, are usually required, making it tedious to analyze large sample numbers, e.g., for population studies. We report a quick sample purification method using anion exchange solid phase extraction (SPE), which is highly selective for acidic compounds. Urine and hydrolyzed plasma of healthy individuals were acidified before SPE extraction, washed with 4 different solvent mixtures and finally eluted with ethyl acetate. The eluted samples were first derivatized with pentafluorobenzyl bromide followed by a second derivatization with bis-(trimethylsilyl)trifluoroacetamide. F2-isoprostanes were analyzed by GC-MS-NCI. The method was highly sensitive; the limit of detection at 5:1 signal-to-noise ratio was 0.037 ng/ml and 0.007 ng/mg creatinine for plasma and urine, respectively. Anion exchange SPE extraction for F2-isoprostane showed recovery of 55-65% and high linearity for concentration 0-1.0 ng/ml for urine (CV=4.08%, r2=0.990) and 0-0.5 ng/ml for plasma (CV=4.07%, r2=0.998). Fasting for 6h significantly increased plasma F2-isoprostanes levels, which has implications for the design of intervention studies using this biomarker.  相似文献   

7.
A sensitive and rapid HPLC assay for determining tazobactam and piperacillin in fatty tissue and serum is described. While the common methods need liquid-liquid extraction before the injection in a automated column switching HPLC, the new method works by direct injection of the filtered tissue extract or diluted serum in a automated column switching HPLC without any other pre-treatment. This was performed by the use of a NH2-precolumn and enrichment/transfer at different pH-level. During the analyses, the NH2-precolumn was automatically regenerated with acetonitrile-water. The chromatogram peaks for piperacillin and tazobactam were identified by the retention time and quantified by peak area. The calibration curve was linear between 1 and 16 microg/ml. The quantification limit of tazobactam was about 1 microg/ml in fatty tissue extracts and in diluted serum (calculated for pure serum 2 microg/ml), respectively. For piperacillin it was less. The described procedure allows sample clean-up and determination of the antibiotic within 35 min. The chromatograms with this easy sample treatment had the same quantity of matrix peaks and in contrast to liquid-liquid extraction no loss of piperacillin. Because of the automatically rinsing of the NH2-precolumn during the chromatographic separation, more than 50 different biological samples could be measured with one NH2-precolumn without loss of performance.  相似文献   

8.
In this research project, a high-performance liquid chromatography (HPLC) method was developed for the determination of acyclovir (ACV) in plasma. The plasma samples, recharged with acyclovir and in presence of 5'-N-methylcarboxyamidoadenosine (MECA) as an internal standard, were purified using a solid-phase extraction technique with Waters Oasis HLB columns. The separation of the components from the extract was carried out in a LiChrospher 100 RP-18 column for further ultraviolet detection at a wavelength range of 250-260 nm. The mobile phase composition was 18% acetonitrile, sodium dodecylsulphate 5 mM and phosphate buffer at pH 2.6 with an analysis time of 13 min per sample. The average retention time for acyclovir was of 5.0 min and for the internal standard 11.2 min. The calibration curve was linear ranging between 0.05 and 1.80 microg/ml. The detection limit was 0.006 microg/ml with a quantification limit of 0.020 microg/ml. The ACV recuperation percentage for 250 microl of plasma was between 94.7 and 109.7% with a coefficient of variation not higher than 5.2%. This method was developed and validated for use in bioavailability and bioequivalence studies.  相似文献   

9.
An HPLC method for the quantification of lamivudine (3TC) in rat plasma, amniotic fluid, placental and fetal tissues has been developed, validated and applied to the study of the placental transport of this drug in the pregnant rat. Placental and fetal tissues were processed using liquid-liquid extraction enhanced by salting out the sample using a saturated solution of ammonium sulfate. Plasma and amniotic fluid samples were processed by protein precipitation using 2 M perchloric acid. Reverse phase chromatography was performed using a phenyl column (5 microm, 150 mm x 2 mm i.d.) under a flow rate of 0.2 ml/min. The mobile phase consisted of 5% methanol in 20 mM dibasic phosphate buffer (pH 6). The method was validated over the range from 0.1 to 50 microg/ml for plasma and amniotic fluid and 0.2-50 microg/ml for the placental and fetal tissues.  相似文献   

10.
A simple, sensitive and reliable HPLC ion-pairing method with fluorescence detection, was developed for penciclovir determination in plasma and aqueous humor, with a Zorbax SB-aq C18 (100 mmx2.1 mm) column. Plasma samples were treated by solid-phase extraction with Oasis MCX (30 mg) cartridges. Ganciclovir, an antiviral drug structurally related to penciclovir, was used as internal standard (I.S.). Aqueous humor samples were directly injected into the chromatographic system. Separation was performed by a gradient elution with a mobile phase consisting of a mixture of acetonitrile and phosphate buffer 50mM containing 5mM of sodium octanesulfonate, pH 2.0, at a flow rate of 0.3 ml/min. The method was validated and showed good performances in terms of linearity, sensitivity, precision and trueness. Quantification limit was obtained at 0.05 microg/ml for aqueous humor and at 0.1 microg/ml for plasma. Finally, the proposed analytical method was used to measure penciclovir in clinical samples for a pharmacokinetic study, after oral administration of famciclovir.  相似文献   

11.
A stable-isotope-dilution HPLC-tandem mass spectrometry-based method was developed for the determination of dextromethorphan in human plasma. Plasma samples were prepared for analysis by solid-phase extraction on octadecylsilane extraction cartridges. Dextromethorphan and the deuterium-labeled dextromethorphan internal standard were chromatographed on a short reversed-phase column and detected by a selected-reaction-monitoring scheme. Linear standard curves were obtained over three orders of magnitude and the limit of quantitation for dextromethorphan was 50 pg/ml, using a 1-ml plasma sample. The combination of HPLC and electrospray tandem mass spectrometry resulted in a rapid, selective and sensitive method for the analysis of dextromethorphan in plasma. The method was applied for the evaluation of the pharmacokinetic profile of dextromethorphan in human volunteers following peroral administration.  相似文献   

12.
Direct stereoselective separation on chiral stationary phase was developed for HPLC analysis of the four stereoisomers of alpha-hydroxymetoprolol in human plasma and urine. Plasma samples were prepared using solid-phase extraction columns and urine samples were prepared by liquid-liquid extraction. The stereoisomers were separated on a Chiralpak AD column at 24 degrees C with fluorescence detection and a mobile phase consisting of a mixture of hexane:ethanol:isopropanol:diethylamine (88:10.2:1.8:0.2) for plasma samples and hexane:ethanol:diethylamine (88:12:0.2) for urine samples. Calibration curves for the individual stereoisomers were linear within the concentration range of 2.0-200 ng/ml plasma or 0.125-25 microg/ml urine. The methods were validated with intra- and interday variations less than 15%. The absolute configuration of the pure stereoisomers were assigned by circular dichroism spectra. The methods were employed to determine the concentrations of alpha-hydroxymetoprolol stereoisomers in a metabolism study of multiple-dose administration of racemic metoprolol to hypertensive patients phenotyped as extensive metabolizers of debrisoquine. We observed stereo-selectivity in the alpha-hydroxymetoprolol formation favoring the new 1'R chiral center from both metoprolol enantiomers (AUC(0-24) (1'R1'S) = 3.02). The similar renal clearances (Cl(R)) of the four stereoisomers demonstrated absence of stereoselectivity in their renal excretion. (-)-(S)-metoprolol was slightly more alpha-hydroxylated than its antipode (AUC(0-24) (2S/2R) = 1.19), suggesting that this pathway is not responsible for plasma accumulation of this enantiomer in humans.  相似文献   

13.
A method was developed for the determination of the seven nitroimidazoles including metronidazole (MNZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole (TNZ), ornidazole (ONZ), secnidazole (SNZ) and the common metabolite of RNZ and hydroxydimetridazole (DMOHZ) in poultry and pork muscles by high-performance liquid chromatography (HPLC) with ultraviolet detection (UV). After extraction with ethyl acetate and evaporation, the nitroimidazoles were redissolved in ethyl acetate and purified using strong cation exchange (SCX) solid-phase extraction (SPE) column. The HPLC separation was carried through on a C(18) bonded silica column with a deionized water-methanol-acetonitrile mobile phase using a gradient elution procedure. The limit of detection of all the seven nitroimidazoles was 0.2 microg/kg. The recoveries of the seven nitroimidazoles for chicken, pork and bacon samples spiked with 1-20 microg/kg were in the range of 71.4-99.5%. The linearity is satisfactory with a correlation coefficient of >0.998 at concentrations ranging from 0.7 to 60 microg/kg. The relative standard deviations of 10 measurements for spiked chicken, pork and bacon samples at the concentration of 1 and 20 microg/kg were in the range of 6.2-13.9% and 4.0-8.7%, respectively. The intra-day precision (n=5) for nitroimidazoles residues in chicken spiked at 20 microg/kg is 6.9%, and the inter-day precision for 5 days (n=25) is 11%. The method is capable of identifying nitroimidazole residues at > or =0.7 microg/kg levels and was applied in the determination of nitroimidazole residues in meat sample.  相似文献   

14.
A sensitive and specific liquid chromatographic-tandem mass spectrometric method is described for the determination of cefaclor in human plasma. The plasma samples were treated by two sample preparation procedures, i.e. protein precipitation (PPT) and solid-phase extraction (SPE). The pretreated samples were analyzed on a C(18) HPLC column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization (ESI) was employed as the ionization source. The analyte and internal standard ampicillin (for PPT) or cefetamet (for SPE) were detected by use of selected reaction monitoring (SRM) mode. The lower limit of quantitation obtained as a result of the PPT procedure was 100 ng/ml. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 12% for cefaclor. The accuracy as determined from QC samples was within +/-3% for the analyte. The SPE procedure could provide the lower limit of quantitation of 2 ng/ml. The precision and accuracy were measured to be below 7.1% and between -3.6% and 1.1%, respectively, for all QC samples. The method was applied for the evaluation of the pharmacokinetic profiles of cefaclor sustained-release formulation.  相似文献   

15.
In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%.  相似文献   

16.
Vincristine is an anticancer agent that continues to be examined in preclinical models even though it is used in a variety of human neoplastic disorders. We developed a sensitive liquid chromatography-mass spectrometry (LC-MS) method for the determination of vincristine in plasma and in brain tissues that would support investigations on drug distribution into tissues in animal models. The procedure required only a small sample volume (10 microl) of plasma, which circumvented a limitation of most other assays that were developed for human samples. A solid-phase extraction procedure was employed that enabled the eluent to be directly injected onto a reversed-phase chromatographic HPLC system using positive electrospray ionization followed by mass spectrometric detection. The extraction recoveries of vincristine were 57 and 60% from plasma and brain tissues, respectively. The mobile phase consisted of methanol and 15 mM ammonium acetate in 0.02% formic acid (70:30) that was pumped at 0.2 ml/min to yield retention times of 1.6 and 1.8 min for vincristine and vinblastine, the internal standard, respectively. The method was validated at vincristine plasma concentrations from 0.01 to 2 microg/ml, and from 0.01 to 1 microg/g in brain tissue. The advantage of the method enabled the quantitation of vincristine in multiple plasma samples obtained from a single mouse, which permitted the accurate estimation of its pharmacokinetic properties.  相似文献   

17.
An HPLC method was developed and validated for the determination of mifepristone in human plasma. C(18) solid-phase extraction cartridges were used to extract plasma samples. Separation was by C(18) column; mobile phase, methanol-acetonitrile-water (50:25:25, v/v/v); flow rate, 0.8 ml/min; UV detection at 302 nm. The calibration curve was linear in the concentration range of 10 ng/ml to 20 microg/ml (r=0.9991). Within- and between-day variability were acceptable. The limit of detection for the assay was 6 ng/ml. Plasma samples were stable for at least 7 days in the state of plasma or residue treated at -20 degrees C. The method was simple, sensitive and accurate, and allowed to determine ng mifepristone in human plasma. It could be applied to assess the plasma level of mifepristone in women receiving low oral doses of mifepristone.  相似文献   

18.
A sensitive reversed-phase HPLC method for the analysis of olanzapine in human plasma is described. Isolation of olanzapine from plasma was accomplished by solid-phase extraction utilizing an ion-exchange/reversed-phase cartridge designed for basic drug extraction. The drug was subsequently separated by reversed-phase HPLC and monitored by electrochemical detection (ED). Electrochemical analysis was used to detect olanzapine due to its uniquely low oxidative potential. Ascorbic acid was added to prevent oxidation during extraction. The limit of quantitation for the assay was established at 0.25 ng/ml utilizing a 1-ml human plasma sample. The average inter-day accuracy was 96.6% with a average precision (%C.V.) of 3.22% over the concentration range of 0.25 to 100 ng/ml. This method was applied to human plasma samples from human clinical trials with olanzapine. The HPLC-ED method compared favorably with a negative chemical ionization GC-MS method previously utilized for analysis of olanzapine in human plasma.  相似文献   

19.
Multidimensional HPLC is a powerful tool for the analysis of samples of a high degree of complexity. This work reports the use of multidimensional HPLC by coupling a RAM column with a chiral polysaccharide column to the analysis of Pantoprazole in human plasma by direct injection. The enantiomers from the plasma samples were separated with high resolution on a tris(3,5-dimethoxyphenylcarbamate) of amylose phase after clean-up by a RAM BSA octyl column. Water was used as solvent for the first 5 min in a flow-rate of 1.0 ml/min for the elution of the plasmatic proteins and then acetonitrile-water (35:65 v/v) for the transfer and analysis of pantoprazole enantiomers, which were detected by UV at 285 nm. Analysis time was 28 min with no time spent on sample preparation. A good linear relationship was obtained in the concentration range of 0.20 to 1.5 microg/ml for each enantiomer. Inter and intra-day precision and accuracy were determined by one low (0.24 microg/ml), one medium (0.70 microg/ml) and one high (1.3 microg/ml) plasma concentration and gave a C.V. varying from 1.80 to 8.43% and accuracy from 86 to 92%. Recoveries of pantoprazole enantiomers were in the range of 93.7-101.2%. The validated method was applied to the analysis of the plasma samples obtained from ten Brazilian volunteers who received an 80 mg oral dose of racemic pantoprazole and was able to quantify the enantiomers of pantoprazole in all clinical samples analyzed.  相似文献   

20.
We improved our previous analytical method to measure phthalate metabolites in urine as biomarkers for phthalate exposure by automating the solid-phase extraction (SPE) procedure and expanding the analytical capability to quantify four additional metabolites: phthalic acid, mono-3-carboxypropyl phthalate, mono-isobutyl phthalate (miBP), and monomethyl isophthalate. The method, which involves automated SPE followed by isotope dilution-high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS), allows for the quantitative measurement of 15 phthalate metabolites in urine with detection limits in the low ng/ml range. SPE automation allowed for the unattended sequential extraction of up to 100 samples at a time, and resulted in an increased sample throughput, lower solvent use, and better reproducibility than the manual SPE. Furthermore, the modified method permitted for the first time, the separation and quantification of mono-n-butyl phthalate (mBP) and its structural isomer miBP. The method was validated on spiked pooled urine samples and on pooled urine samples from persons with no known exposure to phthalates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号